• Title/Summary/Keyword: ViewRay

Search Result 384, Processing Time 0.026 seconds

Reference line for computed tomogram of the mandible (하악골 전산화단층사진촬영시 기준선에 관한 연구)

  • You Choong-Hyun;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.153-157
    • /
    • 2002
  • Purpose : This study was performed to determine the proper reference line for taking axial computed tomograms from which the good cross-sectional views can be reformatted by multiplanar reconstruction. Methods : Three dry mandibles with implanted gutta percha cones in the extracted socket were scanned axially according to 6 reference lines of 2 mandibular positions with computed tomogram Hitachi W550. The accuracy of measurements of the lengths of implanted gutta perch a cones in the each cross-sectional view reformatted from axial computed tomogram by multiplanar reconstruction was evaluated. Results: The difference between the measurements and the real length of implant was smallest in the bucco-lingual views reformatted from the axial views scanned according to the reference line of group V-a. The smaller the angle difference between reference line and occlusal line was, the smaller the difference between the measurements in the bucco-lingual views reformatted from axial views and the real length of implant. The majority of measured widths of implants in the bucco-lingually reformatted views were larger than the actual values. Conclusions : When the mandible is inclined within the limitation of gantry angle and scanned with the reference line coincident with occlusal plane, the bucco-lingual view can be reformatted without deformation of images from the axially scanned images.

  • PDF

Video Augmentation by Image-based Rendering

  • Seo, Yong-Duek;Kim, Seung-Jin;Sang, Hong-Ki
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1998.06b
    • /
    • pp.147-153
    • /
    • 1998
  • This paper provides a method for video augmentation using image interpolation. In computer graphics or augmented reality, 3D information of a model object is necessary to generate 2D views of the model, which are then inserted into or overlayed on environmental views or real video frames. However, we do not require any three dimensional model but images of the model object at some locations to render views according to the motion of video camera which is calculated by an SFM algorithm using point matches under weak-perspective (scaled-orthographic) projection model. Thus, a linear view interpolation algorithm is applied rather than a 3D ray-tracing method to get a view of the model at different viewpoints from model views. In order to get novel views in a way that agrees with the camera motion the camera coordinate system is embedded into model coordinate system at initialization time on the basis of 3D information recovered from video images and model views, respectively. During the sequence, motion parameters from video frames are used to compute interpolation parameters, and rendered model views are overlayed on corresponding video frames. Experimental results for real video frames and model views are given. Finally, discussion on the limitations of the method and subjects for future research are provided.

  • PDF

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

Usefulness Evaluation of Merchant Auxiliary Equipment of Body Type Changing Suitable for X-ray Table Integral Type (체형변화에 적합한 X-선 검사대 일체형 Merchant 보조장비의 유용성 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2773-2779
    • /
    • 2013
  • The purpose of this study was to evaluate of the usefulness and to develop new auxiliary equipment that can bending angle of the bone of the knee various depending on the thickness of the thigh of the human. The subjects agreed for research purposes and were selected from normal person who do not have past knee-related diseases and grouped thin group A and thick group B for the thigh. We set in order to obtain images in the axial direction of the bones of the knee, $35^{\circ}$ to increase by $5^{\circ}$ angle of knee flexion, $45^{\circ}$, to $55^{\circ}$, and we performed combinations of 9 tests by incident angle X-ray per each angle, $40^{\circ}$, $50^{\circ}$ and $60^{\circ}$. As a result, we have developed an Merchant auxillary equipment of X-ray table integral type in radiographic images which was easy to use and could take images of various integral knee joint angles adjusting different body types. Using the auxiliary equipment, in the case of X-ray incident angle $50^{\circ}$ and $60^{\circ}$ with the knee flexion angle of $40^{\circ}$ in group A, and in group B, Knee flexion angle of $45^{\circ}$ and $35^{\circ}$, the X-ray incident angle at $60^{\circ}$, excellent images were derived. Future, it would be very useful in the examination of patients with a variety of body types.

KITSAT-1/2 ANALOG SUN SENSORS-IN-ORBIT RESULTS (우리별 1, 2호 아날로그 태양 감지기의 궤도상 운용결과)

  • 장현석;김병진;임광수;성단근;최순달
    • Journal of Astronomy and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.173-180
    • /
    • 1996
  • This paper briefly describes the KITSAT-1 and KITSAT-2 spacecrafts and presents the functions, calibration procedures and in-orbit results of the KITSAT-2 analog sun sensors have been flown as an experimental payload for the future mission. We have two constraints in their design: small size and very low power consumption due to the tight mass and power budget of the spacecraft. Two one-dimensional analog sun sensors are mounted on the top facet of the KITSAT-2 spaceraft. Each has $\pm$60 degrees of view angle and they cover 210 degree field of view in total as the 30 degree view angles are overlapped. Only the relative sun angle around the Z-axis (yaw-axis) and the spin rate of the spacecraft can be achieved as the one dimensional sun sensors are used and they are aligned with the Z-axis. The calibration formulae are obtained using the fifth order line fitting algorithm for each sun sensor on the ground and they are applied to the obtained in-orbit data. ASS-1 with silicon solar cells has maximum error of 1.5 degree and ASS-2 with silicon photocells manufactured at KAIST has maximum error of 0.5 degree except near 0 degree of sun ray incident anagle where random reflection of incident sun ray is maximum in orbit. The results are presented in chapter 4. The performance of each sun sensor and the possible mounting errors are stated in chapter 5.

  • PDF

One dimensional inhomogeneous aperture modulation effects on the MTF of optical system II (일차원적 비균일 개구변조시 광학계의 최적상면 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.277-281
    • /
    • 1998
  • One dimensional inhomogeneous aperture modulation effects on the MTF of optical system was investigated. The lens under test was a doublet made in Korea. It has 10 mm effective diameter, 87.8 mm effective focal length. The ray-fans and spot diagrams were calculated and presented on the picture for on-axis and off-axis (field of view, $1^{\circ}$ and $2^{\circ}$). Aperture modulation was carried out by positioning a aperture modulator close contacter with the lens under test. We bought two modulators from Edmud Company in U.S.A. One was linear type and the other was stepped type. The MTFs were measured on the best of focus for each modulated aperture where the MTF has the highest value for 60 line/mm and were compared with one another. For on-axis, the MTFs of some modulated apertures had higher values than the MTF of unmodulated aperture in the high frequency region. In the case of off-axis, at the field of view $1^{\circ}$, the MTF values of some modulated aperture are improved prominently and some other one are disimproved. At the field of view $2^{\circ}$ most of the MTFs of modulated apertures had lower values than the MTF of unmodulated aperture except the MTFs of linear and inverse linear type aperture in the high frequency area. But the values of MTFs in high frequency region were too low for actual use.

  • PDF

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

The Clinical Study of Ankle Fracture and Dislocation (족관절의 골절-탈구에 대한 임상적 고찰)

  • Kim, Ji Hoon;Song, Jae Gwang;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.182-188
    • /
    • 2013
  • Purpose: We evaluate clinical manifestations and radiologic features of ankle fracture & dislocation, as well as the usefulness of computed tomography on posterior ankle fracture & dislocation to study factors contributing to ankle fracture & dislocation. Material and Methods: Ankle dislocation was defined as the center of talar body being translated over the cortex of tibia on AP or lateral view on simple X-ray. Surgical treatments of 30 patients from January 2007 to March 2012 were categorized according to the injury mechanism, the direction of dislocation and fracture site. Joint involvement of posterior malleoalr fracture was evaluated through simple x-ray and computed tomography. We treated surgically if posterior malleolus fracture involves more than 25% of dital tibial articular surface. Thereafter, clinical outcomes were identified through radiographs and by using the AOFAS score. Results: The mean age was 42(13-78) years old, and slip down was the most common injury mechanism (13 cases). Car accident (6 cases) and fall accident (4 cases) were the next frequently found injury mechanisms. As for the types of ankle fracture, posterior fracture and dislocation (21 cases, 43.3%) was most commonly found. Out of these 21 cases, 15 cases involved trimalleolar fracture, and 19 cases were associated with posterior malleolar fracture. Danis-weber type B and C patients were 11 cases and 10 cases respectively. Articular involvement of posterior malleolar fracture turned out to be average 27.9%(5.1%~49.1%) on simple x-ray. The rate was evaluated as average 31.7%(12.6%~55.3%) on computed tomography which was conducted 15 times, and led us to more meaningful data. Conclusion: Anterolateral fracture and dislocation often accompanied open dislocation. Posterior fracture dislocation was most commonly found. Posterior malleolus was an important factor that ensures posterior stability of the ankle joint. Computed tomograph is useful to evaluate the articular involvement of posterior malleolar fracture.

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF