• Title/Summary/Keyword: View-height

Search Result 410, Processing Time 0.025 seconds

Analysis of the Visual Quality of Riverfront Skyline Through the Feature of Height and Spatial Arrangement of Tall Building

  • Puspitasari, Ayu Wandira;Kwon, Jongwook
    • Architectural research
    • /
    • v.21 no.4
    • /
    • pp.91-98
    • /
    • 2019
  • In modern times, numerous cities are competing to create the unique skyline adjacent to the water. Tall buildings located across the river have a great contribution to the skyline of a riverfront city and can be a precious asset for the city. Moreover, in several cities, tall buildings and their impact on the urban skyline are a matter that should be considered and regulated in urban design. Therefore, as a prominent element in a larger visual setting of the city, tall buildings should improve the visual quality of the skyline rather than diminish that quality. This research attempts to provide an objective method to analyze the visual quality of the skyline made by a group of tall buildings through their feature of heights and spatial arrangement from riverfront views. The analysis is determined by the design variables of building heights variation, heights transition, density, and spacing of a group of tall buildings. A comparative case study of tall buildings in Yeouido and Lujiazui was conducted to prove the effectiveness of the analysis. The proposed method can be used in a simple way in the quantitative approach to quantify the visual quality of the skyline. In conclusion, Yeuido's skyline is not quite interesting from the riverfront view in terms of height variation and continuity of the skyline view because they are dispersed. Conversely, Lujiazui's skyline from the riverfront vantage points has a good quality in all aspects of the feature of height and spatial arrangements of tall buildings cluster. These factors can be used for the urban designer on how proposed tall buildings within the cluster should appropriately respond to adding image on the skyline.

Classification of Men's Somatotype According to Body Shape and Size(Part II) -Classification of Side View and Compound of Front and Side View- (남성의 동체부 체형분류(제2보) -측면체형의 분류 및 정면과 측면 체형의 조합-)

  • 정재은;김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.10
    • /
    • pp.1443-1454
    • /
    • 2002
  • The purposes of this study were to classify body type of adult males into several kind of shape and to provide the characteristics of size of each group which has same shape. As the sample, subjects were 1290 males of 20 to 54 year-old. The procedure and results were follows; 1. As the result of the previous reserch, the front line of body was classified in X, H, Y and A types. 2. The principal component analysis was used to obtain the shape factor of the side line of the trunk. 9 factors in the side were extracted. As the result of the cluster analysis of factor scores, the side line of body was classified in 5 types. It was named X, A, Y and H type in the front and S, D1, d, I and D2 type in the side. 3. In order to consider the shape of body as a whole, the body shape of the front and side were compounded. The whole body shapes of adult male were very various, and 6 body shapes, XS, YS, Yd, YI, AD2 and HD1 were selected as the basic types. In each type of body, several groups were classified by size factor, height and chest girth and master size was selected considering appearance frequency.

A Case Report of Cleidocranial Dysostosis (쇄골 두개 이골증의 증례보고)

  • Lim C.Y.;Kim S.W.;Ahn H.K.;You D.S.;Park T.W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.49-52
    • /
    • 1977
  • The authors had observed a case of cleidocranial dysostosis of 42 years old unmarried woman. The observation was founded upon roentgenogram of skull P-A view, orthopantomograph, cephalometric view, chest P-A view and wrist X-ray view. The patient gave a dwarfic impression with 145㎝ body height and concaved mandibular prognastic facial feature. The palate was narrowed and extremely high arched. The eruption state of teeth were extremely poor, only four teeth were erupted, composed of upper third molar and lower three deformed teeth. The skull P-A view of roentgenogram reveals overlying metopic suture, extends from the nasion to the sagittal suture, and the suture are delayed up to date and many wormian bones are formed. On the cephalometric view the maxilla is underdeveloped and produce the false mandibular prognathism. Twenty four impacted teeth can be detected by orthopantmograph, twelve in upper jaw and twelve in lower jaw. There are many supernumerary teeth, one in upper jaw and seven in lower jaw. On the chest P-A view, the clavicles are totally aplastic, but a vestige of clavicle is visible in the right side. On the wrist roentgenogram, the epiphyseal ossification of distal phalanx, mesial phalanx and proximal phalanx is delayed.

  • PDF

Spatial View Materialization Technique by using R-Tree Reconstruction (R-tree 재구성 방법을 이용한 공간 뷰 실체화 기법)

  • Jeong, Bo-Heung;Bae, Hae-Yeong
    • The KIPS Transactions:PartD
    • /
    • v.8D no.4
    • /
    • pp.377-386
    • /
    • 2001
  • In spatial database system, spatial view is supported for efficient access method to spatial database and is managed by materialization and non-materialization technique. In non-materialization technique, repeated execution on the same query makes problems such as the bottle-neck effect of server-side and overloads on a network. In materialization technique, view maintenance technique is very difficult and maintenance cost is too high when the base table has been changed. In this paper, the SVMT (Spatial View Materialization Technique) is proposed by using R-tree re-construction. The SVMT is a technique which constructs a spatial index according to the distribution ratio of objects in spatial view. This ratio is computed by using a SVHR (Spatial View Height in R-tree) and SVOC (Spatial View Object Count). If the ratio is higher than the average, a spatial view is materialized and the R-tree index is re-used. In this case, the root node of this index is exchanged a node which has a MBR (Minimum Boundary Rectangle) value that can contains the whole region of spatial view at a minimum size. Otherwise, a spatial view is materialized and the R-tree is re-constructed. In this technique, the information of spatial view is managed by using a SVIT (Spatial View Information Table) and is stored on the record of this table. The proposed technique increases the speed of response time through fast query processing on a materialized view and eliminates additional costs occurred from repeatable query modification on the same query. With these advantages, it can greatly minimize the network overloads and the bottle-neck effect on the server.

  • PDF

Effect of noise barrier on aerodynamic performance of high-speed train in crosswind

  • Zhao, Hai;Zhai, Wanming;Chen, Zaigang
    • Wind and Structures
    • /
    • v.20 no.4
    • /
    • pp.509-525
    • /
    • 2015
  • A three-dimensional aerodynamic model and a vehicle dynamics model are established to investigate the effect of noise barrier on the dynamic performance of a high-speed train running on an embankment in crosswind in this paper. Based on the developed model, flow structures around the train with and without noise barrier are compared. Effect of the noise barrier height on the train dynamic performance is studied. Then, comparisons between the dynamic performance indexes of the train running on the windward track and on the leeward track are made. The calculated results show that the noise barrier has significant effects on the structure of the flow field around the train in crosswind and thus on the dynamic performance of the high-speed train. The dynamic performance of the train on the windward track is better than that on the leeward track. In addition, various heights of the noise barrier will have different effects on the train dynamic performance. The dynamic performance indexes keep decreasing with the increase of the noise barrier height before the height reaches a certain value, while these indexes have an inverse trend when the height is above this value. These results suggest that optimization on the noise barrier height is possible and demonstrate that the designed noise barrier height of the existing China Railway High-speed line analysed in this article is reasonable from the view point of the flow field structure and train dynamic performance although the noise barrier is always designed based on the noise-related standard.

Evaluation of available height, location, and patency of the ostium for sinus augmentation from an implant treatment planning perspective

  • Vaddi, Anusha;Villagran, Sofia;Muttanahally, Kavya Shankar;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.243-250
    • /
    • 2021
  • Purpose: The objective of this study was to evaluate the amount of height available for a maxillary sinus augmentation procedure without blocking the ostium and jeopardizing the drainage of the ostiomeatal complex using cone-beam computed tomography (CBCT) imaging. Materials and Methods: A total of 200 sinonasal complexes comprising 100 dentate and 100 edentulous scans were retrospectively assessed using CBCT. Invivo 5.0, a CBCT reconstruction program, was used for image evaluation. The coronal section demonstrating the ostiomeatal complex was selected as a reference view to perform measurements of the sinus. The measurements were done by 2 evaluators in separate sessions. Comparative analyses of measurements were performed between dentate and edentulous patients and between male and female patients. Results: The safe height to which the sinus can be elevated without compromising the integrity of the ostiomeatal complex was calculated for each sinus. In the presence of significant mucosal thickening, the height available for augmentation was calculated by subtracting the height of mucosal thickening from the sinus floor to the location of the ostium. In this study, the available height was approximately 27.05 mm for dentate and 23.40 mm for edentulous patients. The inter-operator reliability was excellent for all the parameters evaluated. Conclusion: This retrospective study with a limited number of patients from a single university-based site shows that CBCT is valuable in evaluating the location and patency of the ostium for planning sinus augmentation procedures for dental implant placement.

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

A Study on the Facial Morphologic Characteristics of Mongolian according to Sasangin : Pilot Study (몽골인의 사상체질별 안면부 특징 : 예비 연구)

  • Lee, Jun-Hee;Kim, Kyung-Su;Lee, Gab-Su;Yoo, Jung-Hee;Moon, Young-Sik;Bazargarid, Luvsannyam;Tumurbaatar, N.;Oldokh, S.;Sukhbaatar, Tubdengiin;Kim, Jong-Yoel;Lee, Si-Woo;Kim, Hyo-Jung;Hwang, Min-Woo;Koh, Byung-Hee;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.62-74
    • /
    • 2007
  • 1. Objectives This study is a pilot study to investigate the Mongolian's morphologic characteristics of face according to Sasang Constitution. 2. Methods We had collected 100 cases of Mongolian and took pictures their frontal view, lateral view of face and measured height, breaths and projected length of face with Face Features Measurement Program(FFMP) and analyzed shape differences of face according to Sasang constitution. 3. Results and Conclusions (1) In the frontal view of female, there were 11 items(total 322 items) significantly different among three constitutions, and in lateral view 13 items(total 191 items). (2) In the frontal view of male, there were 88 items(total 322 items) significantly different among three constitutions, and in lateral view 46 items(total 191 items).

  • PDF

A Study on the Shapes of Women′s Neck and Shoulder in Dressmaking I (의복설계를 위한 성인여성의 經部 및 肩部의 유형화 I)

  • 김희숙
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.668-680
    • /
    • 2000
  • The study presents the general types and individual differences of the shape of the adult women's neck and shoulder in our country. It is based on the average value, the standard deviation, the maximum value, the standard deviation, the maximum value, the minimum value and c.v. measured from the women at the age of 19 through 64. The results of this study are as follows ; 1. The factors by factor analysis are five. The first is the size factors of the neck and shoulder. The second is shape factor of neck. The third is plane view and length factor of the neck. The fourth is the side view factor of the neck and shoulder. The fifth is the shape factor of shoulder. Therefore the shape of the neck and shoulder should be examined in the shape factors as well as in the size factors as well as in the size factors for the designing body-suitable clothes. 2. The factors of the concrete objects are the solid view of neck and shoulder, the cross-sectional view of neck line, side view of neck and shoulder and length of neck. The explainable measuring items for the factors are the difference of the length between lower neck round line and the 4㎝ above neck round line, the length of neck, the angle of inclination between fore neck and back neck, the angle of inclination of the side shoulder, the difference of the height between fore neck point and back neck point, the width of shoulder, the width of chest and the width of back. 3. The concrete objects of the neck and shoulder have five types ; Type Ⅰ is average type, Type Ⅱ is thick short neck and the drooping shoulder type, Type Ⅲ I is slender long neck and lean-back shoulder type, Type Ⅳ is thick and rising shoulder type and Type Ⅴ is slender and drooping shoulder type.

  • PDF

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.