• Title/Summary/Keyword: View Axis

Search Result 352, Processing Time 0.031 seconds

Operational Vibration Experiment and Analysis of a Small Vertical-Axis Wind Turbine Considering the Effect of Tower Stiffness (타워강성 효과를 고려한 소형 수직축 풍력발전기 운전 진동실험 및 해석)

  • Choo, Heon-Ho;Sim, Jae-Park;Ryu, Gyeong-Joong;Kim, Dong-Hyun;Kim, Bong-Yung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.602-606
    • /
    • 2011
  • In this study, operational vibration experiment and analysis have been conducted for the 4-blade small vertical-axis wind turbine (VAWT) including the effect of tower elastic behavior. Computational structural dynamics analysis method is applied to obtain Campbell diagram for the VAWT with elastic tower. An open type wind-tunnel is used to change and keep the wind velocity during the ground test. Equivalent reduced elastic tower is supported to the VAWT so that the elastic stiffness effect of the tower can be reflected to the present vibration experiment. Various excitation sources with aerodynamic forces are considered and the dominant operating vibration phenomena are physically investigated in detail.

  • PDF

Study of Ultra-Small Optical Anisotropy Profile of Rubbed Polyimide Film by using Transmission Ellipsometry

  • Lyum, Kyung Hun;Yoon, Hee Kyu;Kim, Sang Jun;An, Sung Hyuck;Kim, Sang Youl
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.156-161
    • /
    • 2014
  • Anisotropy profile of a rubbed polyimide film is investigated using both a modified ultra high precision transmission ellipsometer and the analysis software previously developed to determine the optic axis distribution of discotic liquid crystals in the wide view film. The distorted sinusoidal variation of the ellipsometric constants obtained at an oblique angle of incidence indicates that the optic axis varies from $14.7^{\circ}$ to $40.6^{\circ}$ from the sample plane. The magnitude and distribution of anisotropy is expressed in terms of no, ne, and the cosine-shaped tilt angle distribution of the optic axis in a rubbed polyimide film.

ON THE STABILITY OF MEDIAL AXIS TRANSFORM

  • Choi, Sung-Woo
    • Journal of applied mathematics & informatics
    • /
    • v.23 no.1_2
    • /
    • pp.419-433
    • /
    • 2007
  • Medial axis transform (MAT) is very sensitive to noise, in the sense that, even if a shape is perturbed only slightly, the Hausdorff distance between the MATs of the original shape and the perturbed one may be large. Recently, Choi et al.(2002) showed that MAT is stable for a class of 2D domains called weakly injective, if we view this phenomenon with the one-sided Hausdorff distance, rather than with the two-sided Hausdorff distance. In this paper, we extend this result to general 2D domains with natural boundary regularity. We also present explicit bounds for this general one-sided stability of the 2D MAT.

A STUDY ON THE POSITION OF CONDYLAR HEAD ON COMPUTED TOMOGRAM (전산화 단층 촬영법을 이용한 하악과두의 위치에 관한 연구)

  • Lee Jong Bok;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.151-162
    • /
    • 1987
  • The author obtained the computed tomograms around the condylar head from 10 normal subjects and 5 patients having clicking condylar head from 10 normal subjects and 5 patients having clicking sound or limitation of mouth opening by using a Hitachi-W 500. And then. the author had the axial analysis of condyle position and sagittal analysis of that after sagittal reformation on centric occlusion and 18㎜ interincisal opening. Transcranial view and submentovertex view were taken and compared with computed tomographic view. The obtained results were as follows: 1. Median angle of long axis of condylar head was 17 degrees on centric occlusion and the angles of long axis of both condylar heads were reduced symmetrically on 18㎜ interincisal opening in normal group. however. in the patient group, the affected side of condyle heads showed greater change in the angle on 18㎜ interincisal opening. 2. In the patient group, the condyle head of affected side was located superiorly to that of normal side on centric occlusion and the discrepancy of condular positional height was increased after 18㎜ interincisal opening. 3. The distances from medial pole of condylar head to triangular fossa of temporal bone were same on both right and left side in normal group, however, in the patient group, the distance of affected side was wider than that of opposite side on centric occusion and became narrower than the opposite side on 18㎜ interincisal opening. 4. The distances of posterior joint space were same on both right and left side. The distance t lateral pole 1/3 of condyle head was similar to that on transcranial view on centric occlusion in normal group. 5. The distances of posterior joint space were narrower in patient group than in normal group. 6. Conclusively, the affected condylar head of patient showed postero-latero-superior displacement on centric occlusion and larger range of rotational movement on 18㎜ interincisal opening.

  • PDF

Design and Implementation of Frontal-View Algorithm for Smartphone Gyroscopes (스마트폰 자이로센서를 이용한 Frontal-View 변환 알고리즘 설계 및 구현)

  • Cho, Dae-Kyun;Park, Seok-Cheon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.199-206
    • /
    • 2012
  • Attempt to use as a marker of natural objects directly in the real world, but there is a way to use the accelerometer of the smartphone, to convert the Frontal-View virtual, because it asks only the pitch of the camera, from the side there is a drawback that can not be converted to images. The proposed algorithm, to obtain the rotation matrix of axis 3 pitch, roll, yaw, we set the reference point of the yaw of the target image. Then, to compensate for the rotation matrix to determine Myon'inji any floor, wall, the ceiling of the target image. Finally, to obtain the homography matrix for obtaining the Frontal-View to account for the difference between the gyro sensor coordinate system and image coordinate system, so we can get the Frontal-View from the captured images through the projection transformation was designed. Was tested to convert Frontal-View the picture was taken in an environment smartphone environment surrounding floor, walls and ceiling in order to evaluate the conversion program Frontal-View has been implemented, in this paper, design and The conversion algorithm implementation, it was confirmed that to convert a regular basis Frontal-View footage taken from multiple angles.

The Grid and Axis in Modern Architecture From Durand to Le Corbusier (현대건축에서 그리드와 축에 관한 연구 -듀랑에서부터 르 코르뷔제까지-)

  • Pai, Hyung-Min
    • Journal of architectural history
    • /
    • v.11 no.4 s.32
    • /
    • pp.99-115
    • /
    • 2002
  • Centered on Durand and Le Corbusier, this study analyses the changing status of the grid and axis in modern architecture. In the Renaissance, the taxis grid operated as a contour grid, defining the elements and space of the building as part of closed harmonized world. In his Pre'cis des lec., ons d'architecture, Durand provides the most explicit demonstration of a new modem grid in which its lines function as spatial and structural axes. In principle these axes are coordinates for the placements of a priori elements but in Beaux-Arts practice, as Durand himself acknowledged, they involve a simultaneous process in which the spatial axis sets up the basic parti and the structural axis is developed into the building's poche'. As a coordinate, Durand's grid provides a place for the 'subject' to enter the architectural process. At the same time, it is the object of the subject's gaze, the dense site of the subject's transformative actions. Though Le Corbusier is noted for his frequent attacks on the academic system, his architecture should be seen within the continuity of the classical tradition. He redefines the Beaux-Arts axis as a moving and seeing observer, and continues the discipline of the plan, the essential discipline of the Beaux-Arts system. In his dialectics, an intellectual scheme which extends to his commentators, the intention and will of the subject must come in tune with the objective material form of the building. Like Durand, Le Corbusier's axis provides the medium for the subject to enter. Unlike the Beaux-Arts system, however, Le Corbusier's mobile subject no longer has a holistic view of the building previously provided by the central axis. If there is a parti for Le Corbusier, it consists of the domino grid as a potential, but nonetheless, tangible form. In comparison with the Beaux-Arts structural grid, his gaze no longer lingers on their lines because they no longer constitute a formal process tied to the development of a thick articulated structure. Le Corbusier's grid constitutes a 'loose' form, one that breaks down the hierarchical nature of the Beaux-Arts system.

  • PDF

Analysis of Noise Effects in Data Acquisition of Multi-Axis Force/Torque Sensors

  • Kang, Chul-Goo;Kim, Yong-Chan;Park, Chol-Ho;Nam, Hyun-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1254-1258
    • /
    • 2003
  • One of the major factors that effect sensor performance is analog noise that added in a sensor signal such as voltage. In multi-axis force sensors, error sources may be classified mainly in two groups. One is structural error due to inaccuracy of sensor body. The other error source is noise signals existing in the sensed information. This paper presents a brief review about the principle of multi-axis force sensors, and then proposes a method that can reduce the effect of noise signal to sensor performance. The method is to convert analog voltage signal to digital numbers near sensor body and then to read these digital signals and conduct signal processing in the computer. By this way, we can eliminate a bad effect of electromagnetic wave emitted from computer and of 60 Hz noise emitted from AC source. The proposed method is investigated through experimental demonstration. The experimental results show that it improves S/N ratio of the sensor about 40 times in our experimental setup.

  • PDF

A RADIOGRAPHIC STUDY ON THE POSITIONAL RELATIONSHIP OF THE MANDIBLE TO THE HINGE AXIS (접번축에 대한 하악의 위치관계 및 변위에 관한 방사선학적 연구)

  • Kim Jae Duk;Kim Won Pyo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.91-98
    • /
    • 1991
  • This study was made to analyze the positional relationship of mandible to hinge axis in normal subject as the diagnostic criteria of T.M.J. dysfunction. The author has conducted the study using the Cephalometric P-A view, and dental of 53 males and 51 females. By measurement, the standard value of cranio-facial and occlusal asymmetry in normal subject obtained. The following results were obtained: 1. Although the degree of the difference between right and left width in each measured line was small, asymmetry in normal subject could be identified. 2. In male, measurement between genial tubercle and hinge axis is 127.20±6.06㎜ in left, 125.83±6.25㎜ in right, and angle between genial tubercle and hinge axis is 48.48±3.53° in left, 49.58±3.72° in right. In female, measurement is 119.32±5.81㎜ in left, 118.82±5.35㎜ in right and angle is 48.06±2.15° in left, 48.17±2.31° in left, 48.17±2.31° in right. 3. In male, difference between left and right canine cusp tip of maxilla about X-bar is 0.70±0.59㎜, and that of central pit of first molar of maxilla is 0.98±0.75㎜. In female, difference is 0.64±0.52㎜ in canine and 0.92±0.76㎜ in molar.

  • PDF

Effect of position of hexagonal opening in concrete encased steel castellated beams under flexural loading

  • Velrajkumar, G.;Muthuraj, M.P.
    • Computers and Concrete
    • /
    • v.26 no.1
    • /
    • pp.95-106
    • /
    • 2020
  • Castellated beams fabricated from standard I-sections are being used for several structural applications such as commercial and industrial buildings, multistory buildings, warehouses and portal frames in view of numerous advantages. The advantages include enhanced moment of inertia, stiffness, flexural resistance, reduction in weight of structure, by passing the used plate girders, the passage of service through the web openings etc. In the present study, experimental and numerical investigations were carried out on concrete encased steel castellated beams with hexagonal openings under flexural loading. Various positions of openings such as along the neutral axis, above the neutral axis and below the neutral axis were considered for the study. From the experimental findings, it has been observed that the load-carrying capacity of the castellated beam with web opening above neutral axis is found to be higher compared to other configurations. Nonlinear finite element analysis was performed by using general purpose finite element software ABAQUS considering the material nonlinearities. Concrete damage plasticity model was employed to model the nonlinearity of concrete and elasto-plastic model for steel. It has been observed that FE model could able to capture the behaviour of concrete encased steel castellated beams and the predicted values are in good agreement with the corresponding experimental values.

One dimensional inhomogeneous aperture modulation effects on the MTF of optical system II (일차원적 비균일 개구변조시 광학계의 최적상면 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.277-281
    • /
    • 1998
  • One dimensional inhomogeneous aperture modulation effects on the MTF of optical system was investigated. The lens under test was a doublet made in Korea. It has 10 mm effective diameter, 87.8 mm effective focal length. The ray-fans and spot diagrams were calculated and presented on the picture for on-axis and off-axis (field of view, $1^{\circ}$ and $2^{\circ}$). Aperture modulation was carried out by positioning a aperture modulator close contacter with the lens under test. We bought two modulators from Edmud Company in U.S.A. One was linear type and the other was stepped type. The MTFs were measured on the best of focus for each modulated aperture where the MTF has the highest value for 60 line/mm and were compared with one another. For on-axis, the MTFs of some modulated apertures had higher values than the MTF of unmodulated aperture in the high frequency region. In the case of off-axis, at the field of view $1^{\circ}$, the MTF values of some modulated aperture are improved prominently and some other one are disimproved. At the field of view $2^{\circ}$ most of the MTFs of modulated apertures had lower values than the MTF of unmodulated aperture except the MTFs of linear and inverse linear type aperture in the high frequency area. But the values of MTFs in high frequency region were too low for actual use.

  • PDF