• 제목/요약/키워드: View Axis

검색결과 356건 처리시간 0.036초

타워강성 효과를 고려한 소형 수직축 풍력발전기 운전 진동실험 및 해석 (Operational Vibration Experiment and Analysis of a Small Vertical-Axis Wind Turbine Considering the Effect of Tower Stiffness)

  • 추헌호;심재박;류경중;김동현;김봉영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.602-606
    • /
    • 2011
  • In this study, operational vibration experiment and analysis have been conducted for the 4-blade small vertical-axis wind turbine (VAWT) including the effect of tower elastic behavior. Computational structural dynamics analysis method is applied to obtain Campbell diagram for the VAWT with elastic tower. An open type wind-tunnel is used to change and keep the wind velocity during the ground test. Equivalent reduced elastic tower is supported to the VAWT so that the elastic stiffness effect of the tower can be reflected to the present vibration experiment. Various excitation sources with aerodynamic forces are considered and the dominant operating vibration phenomena are physically investigated in detail.

  • PDF

Study of Ultra-Small Optical Anisotropy Profile of Rubbed Polyimide Film by using Transmission Ellipsometry

  • Lyum, Kyung Hun;Yoon, Hee Kyu;Kim, Sang Jun;An, Sung Hyuck;Kim, Sang Youl
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.156-161
    • /
    • 2014
  • Anisotropy profile of a rubbed polyimide film is investigated using both a modified ultra high precision transmission ellipsometer and the analysis software previously developed to determine the optic axis distribution of discotic liquid crystals in the wide view film. The distorted sinusoidal variation of the ellipsometric constants obtained at an oblique angle of incidence indicates that the optic axis varies from $14.7^{\circ}$ to $40.6^{\circ}$ from the sample plane. The magnitude and distribution of anisotropy is expressed in terms of no, ne, and the cosine-shaped tilt angle distribution of the optic axis in a rubbed polyimide film.

ON THE STABILITY OF MEDIAL AXIS TRANSFORM

  • Choi, Sung-Woo
    • Journal of applied mathematics & informatics
    • /
    • 제23권1_2호
    • /
    • pp.419-433
    • /
    • 2007
  • Medial axis transform (MAT) is very sensitive to noise, in the sense that, even if a shape is perturbed only slightly, the Hausdorff distance between the MATs of the original shape and the perturbed one may be large. Recently, Choi et al.(2002) showed that MAT is stable for a class of 2D domains called weakly injective, if we view this phenomenon with the one-sided Hausdorff distance, rather than with the two-sided Hausdorff distance. In this paper, we extend this result to general 2D domains with natural boundary regularity. We also present explicit bounds for this general one-sided stability of the 2D MAT.

전산화 단층 촬영법을 이용한 하악과두의 위치에 관한 연구 (A STUDY ON THE POSITION OF CONDYLAR HEAD ON COMPUTED TOMOGRAM)

  • 이종복;김재덕
    • 치과방사선
    • /
    • 제17권1호
    • /
    • pp.151-162
    • /
    • 1987
  • The author obtained the computed tomograms around the condylar head from 10 normal subjects and 5 patients having clicking condylar head from 10 normal subjects and 5 patients having clicking sound or limitation of mouth opening by using a Hitachi-W 500. And then. the author had the axial analysis of condyle position and sagittal analysis of that after sagittal reformation on centric occlusion and 18㎜ interincisal opening. Transcranial view and submentovertex view were taken and compared with computed tomographic view. The obtained results were as follows: 1. Median angle of long axis of condylar head was 17 degrees on centric occlusion and the angles of long axis of both condylar heads were reduced symmetrically on 18㎜ interincisal opening in normal group. however. in the patient group, the affected side of condyle heads showed greater change in the angle on 18㎜ interincisal opening. 2. In the patient group, the condyle head of affected side was located superiorly to that of normal side on centric occlusion and the discrepancy of condular positional height was increased after 18㎜ interincisal opening. 3. The distances from medial pole of condylar head to triangular fossa of temporal bone were same on both right and left side in normal group, however, in the patient group, the distance of affected side was wider than that of opposite side on centric occusion and became narrower than the opposite side on 18㎜ interincisal opening. 4. The distances of posterior joint space were same on both right and left side. The distance t lateral pole 1/3 of condyle head was similar to that on transcranial view on centric occlusion in normal group. 5. The distances of posterior joint space were narrower in patient group than in normal group. 6. Conclusively, the affected condylar head of patient showed postero-latero-superior displacement on centric occlusion and larger range of rotational movement on 18㎜ interincisal opening.

  • PDF

스마트폰 자이로센서를 이용한 Frontal-View 변환 알고리즘 설계 및 구현 (Design and Implementation of Frontal-View Algorithm for Smartphone Gyroscopes)

  • 조대균;박석천
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.199-206
    • /
    • 2012
  • 본 논문에서는 스마트폰의 자이로센서를 이용하여 다양한 각도에서 촬영한 현실세계의 객체를 증강현실을 위한 자연 마커로 사용할 수 있도록 가상의 Frontal-View로 변환할 수 있는 알고리즘을 설계하고 구현하였다. 제안한 알고리즘은 pitch, roll, yaw 3축에 대한 회전행렬을 획득하여 대상 이미지에 대한 yaw의 기준점을 설정하였다. 그 후 대상 이미지가 바닥, 벽면, 천장 중 어느 면인지 판단하여 그에 대한 회전 행렬을 보정하였다. 마지막으로 자이로 센서 좌표계와 영상 좌표계 사이의 차이를 고려해 Frontal-View를 얻기 위한 호모그래피 행렬을 획득하여 투영변환을 통해 촬영 영상으로부터 Frontal-View를 획득할 수 있도록 설계하였다. 구현된 Frontal-View 변환 프로그램을 평가하기 위해 바닥, 벽면, 천장에 대해 주변 환경을 스마트폰 환경에서 촬영한 영상을 Frontal-View로 변환하도록 테스트를 한 결과 본 논문에서 설계 및 구현한 변환 알고리즘이 여러 각도에서 촬영한 영상을 정상적으로 Frontal-View로 변환하는 것을 확인하였다.

현대건축에서 그리드와 축에 관한 연구 -듀랑에서부터 르 코르뷔제까지- (The Grid and Axis in Modern Architecture From Durand to Le Corbusier)

  • 배형민
    • 건축역사연구
    • /
    • 제11권4호
    • /
    • pp.99-115
    • /
    • 2002
  • Centered on Durand and Le Corbusier, this study analyses the changing status of the grid and axis in modern architecture. In the Renaissance, the taxis grid operated as a contour grid, defining the elements and space of the building as part of closed harmonized world. In his Pre'cis des lec., ons d'architecture, Durand provides the most explicit demonstration of a new modem grid in which its lines function as spatial and structural axes. In principle these axes are coordinates for the placements of a priori elements but in Beaux-Arts practice, as Durand himself acknowledged, they involve a simultaneous process in which the spatial axis sets up the basic parti and the structural axis is developed into the building's poche'. As a coordinate, Durand's grid provides a place for the 'subject' to enter the architectural process. At the same time, it is the object of the subject's gaze, the dense site of the subject's transformative actions. Though Le Corbusier is noted for his frequent attacks on the academic system, his architecture should be seen within the continuity of the classical tradition. He redefines the Beaux-Arts axis as a moving and seeing observer, and continues the discipline of the plan, the essential discipline of the Beaux-Arts system. In his dialectics, an intellectual scheme which extends to his commentators, the intention and will of the subject must come in tune with the objective material form of the building. Like Durand, Le Corbusier's axis provides the medium for the subject to enter. Unlike the Beaux-Arts system, however, Le Corbusier's mobile subject no longer has a holistic view of the building previously provided by the central axis. If there is a parti for Le Corbusier, it consists of the domino grid as a potential, but nonetheless, tangible form. In comparison with the Beaux-Arts structural grid, his gaze no longer lingers on their lines because they no longer constitute a formal process tied to the development of a thick articulated structure. Le Corbusier's grid constitutes a 'loose' form, one that breaks down the hierarchical nature of the Beaux-Arts system.

  • PDF

Analysis of Noise Effects in Data Acquisition of Multi-Axis Force/Torque Sensors

  • Kang, Chul-Goo;Kim, Yong-Chan;Park, Chol-Ho;Nam, Hyun-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1254-1258
    • /
    • 2003
  • One of the major factors that effect sensor performance is analog noise that added in a sensor signal such as voltage. In multi-axis force sensors, error sources may be classified mainly in two groups. One is structural error due to inaccuracy of sensor body. The other error source is noise signals existing in the sensed information. This paper presents a brief review about the principle of multi-axis force sensors, and then proposes a method that can reduce the effect of noise signal to sensor performance. The method is to convert analog voltage signal to digital numbers near sensor body and then to read these digital signals and conduct signal processing in the computer. By this way, we can eliminate a bad effect of electromagnetic wave emitted from computer and of 60 Hz noise emitted from AC source. The proposed method is investigated through experimental demonstration. The experimental results show that it improves S/N ratio of the sensor about 40 times in our experimental setup.

  • PDF

접번축에 대한 하악의 위치관계 및 변위에 관한 방사선학적 연구 (A RADIOGRAPHIC STUDY ON THE POSITIONAL RELATIONSHIP OF THE MANDIBLE TO THE HINGE AXIS)

  • 김재덕;김원표
    • 치과방사선
    • /
    • 제21권1호
    • /
    • pp.91-98
    • /
    • 1991
  • This study was made to analyze the positional relationship of mandible to hinge axis in normal subject as the diagnostic criteria of T.M.J. dysfunction. The author has conducted the study using the Cephalometric P-A view, and dental of 53 males and 51 females. By measurement, the standard value of cranio-facial and occlusal asymmetry in normal subject obtained. The following results were obtained: 1. Although the degree of the difference between right and left width in each measured line was small, asymmetry in normal subject could be identified. 2. In male, measurement between genial tubercle and hinge axis is 127.20±6.06㎜ in left, 125.83±6.25㎜ in right, and angle between genial tubercle and hinge axis is 48.48±3.53° in left, 49.58±3.72° in right. In female, measurement is 119.32±5.81㎜ in left, 118.82±5.35㎜ in right and angle is 48.06±2.15° in left, 48.17±2.31° in left, 48.17±2.31° in right. 3. In male, difference between left and right canine cusp tip of maxilla about X-bar is 0.70±0.59㎜, and that of central pit of first molar of maxilla is 0.98±0.75㎜. In female, difference is 0.64±0.52㎜ in canine and 0.92±0.76㎜ in molar.

  • PDF

Effect of position of hexagonal opening in concrete encased steel castellated beams under flexural loading

  • Velrajkumar, G.;Muthuraj, M.P.
    • Computers and Concrete
    • /
    • 제26권1호
    • /
    • pp.95-106
    • /
    • 2020
  • Castellated beams fabricated from standard I-sections are being used for several structural applications such as commercial and industrial buildings, multistory buildings, warehouses and portal frames in view of numerous advantages. The advantages include enhanced moment of inertia, stiffness, flexural resistance, reduction in weight of structure, by passing the used plate girders, the passage of service through the web openings etc. In the present study, experimental and numerical investigations were carried out on concrete encased steel castellated beams with hexagonal openings under flexural loading. Various positions of openings such as along the neutral axis, above the neutral axis and below the neutral axis were considered for the study. From the experimental findings, it has been observed that the load-carrying capacity of the castellated beam with web opening above neutral axis is found to be higher compared to other configurations. Nonlinear finite element analysis was performed by using general purpose finite element software ABAQUS considering the material nonlinearities. Concrete damage plasticity model was employed to model the nonlinearity of concrete and elasto-plastic model for steel. It has been observed that FE model could able to capture the behaviour of concrete encased steel castellated beams and the predicted values are in good agreement with the corresponding experimental values.

일차원적 비균일 개구변조시 광학계의 최적상면 MTF에 미치는 영향 (One dimensional inhomogeneous aperture modulation effects on the MTF of optical system II)

  • 홍경희
    • 한국광학회지
    • /
    • 제9권5호
    • /
    • pp.277-281
    • /
    • 1998
  • 일차원적 비균일 진폭변조가 광학계의 최적 상평면 상에서의 MTF에 미치는 영향을 연구하였다. 시험평가 렌즈는 국산 유효경 10mm, 초점거리 87.8mm인 이중렌즈를 택하였다. 시험렌즈의 수차특성은 축상과 시계각 $1^{\circ}$$2^{\circ}$인 비축에 대해 각각 ray-fan 과 파면수차를 계산하여 그림으로 도시하였다. 진폭변조는 시험렌즈 앞에 근접하여 진폭변조판을 위치함으로 이루어 진다. 진폭변조판은 계단식으로 투과도가 다른 것과 연속적으로 투과도가 변하는 것으로서 미국 Edmund사 제품을 사용하였다. 진폭변조하였을 때에 각각의 경우 60line/mm의 공간주파수에서 최대 MTF값을 가지는 상평면을 best of focus 로 결정하였다. 진폭변조의 경우와 변조하지 않은 경우에 대하여 MTFM를 측정해서 그 값을 서로 비교하였다. Gaussian 상평면 상에서 MTF를 측정하였을 때와는 상이한 결과가 나타났다. 축상에서는 변조할 경우에 MTF 값이 변조하지 않은 경우에 비해 고주파로 갈수록 증진되는 효과가 나타났으며 축외에서는 시계각 $1^{\circ}$에서는 다양한 결과가 나타나서 현저하게 증진되는 경우가 있는가 하면 오히려 감소하는 경우도 있다. 시계각 $2^{\circ}$에서는 변조할 경우에 MTF 값이 변조하지 않은 경우 보다 대체로 감소하여 역효과가 나타났고 고주파 부분에서 다소 증가하는 경우가 있으나 그 값 자체가 매우 작으므로 실용적인 가치가 적게 나타났다.

  • PDF