• Title/Summary/Keyword: View Angle

Search Result 802, Processing Time 0.026 seconds

Research on Virtual Simulator Sickness Using Field of View Restrictor According to Human Factor levels (FOV Restrictor를 활용한 가상 멀미 저감 요소 기술연구)

  • Kim, Chang-seop;Kim, So-Yeon;Kim, Kwanguk
    • Journal of the Korea Computer Graphics Society
    • /
    • v.24 no.3
    • /
    • pp.49-59
    • /
    • 2018
  • Simulator sickness is one of the important side effect of virtual reality. Simulator sickness is influenced by various factors, and field of view (FOV) is one of them. The FOV is a viewing angle limited by the screen, and when the FOV is reduced, the simulator sickness is reduced, and the presence is lowered. Previous study developed a Dynamic FOV Restrictor (Center-fixed FOV Restrictor) to reduce simulator sickness while maintaining presence. It is a method that limits the FOV dynamically by reflecting the speed and angular velocity of the avatar. We also developed Eye-tracking Based Dynamic FOV Restrictor (Eye-tracking FOV Restrictor) by adding head rotations and eye movements. This study attempts to compare the simulator sickness and the presence of the No FOV Restrictor condition, the Center-fixed FOV Restrictor condition, and the Eye-tracking FOV Restrictor condition. The results showed that the simulator sickness of the Center-fixed FOV Restrictor condition is significantly lower than other two conditions. The results also showed that there were no significant differences in presence in three conditions. The interpretations and limitations of this study are discussed in this paper.

The Study of Grashey Method Viewing the Glenohumeral(shoulder) Joint (어깨관절의 접시오목을 나타내는 Grashey법에 대한 연구)

  • Lee, Jaeseob;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.331-335
    • /
    • 2015
  • Consideration of Glenohumeral joint's image with the Changed Body angle of the Glenohumeral joint's Oblique Position in Erect Position. Glenohumeral joint's of Grashey method is a shoulder oblique method available to view the shoulder joint. Grashey method projects AP view of the Glenohumeral joint's so that the Humerus head's subluxation or joint degeneration can be easily visualized. However in this view, the patients, erect position, have to keep their body obliquely. Oblique position is will be needed to get the good quality Glenohumeral joint's view. Therefore, we thought of examining a method which shows the Glenohumeral joint's well by angling the patient one side upward in erect position. For this study, total 20 subject with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 13 mails and 7 femails, Statistic group analysis was performed with ANOVA test. Score of the evaluation of the expects were $30^{\circ}$ at $0.40{\pm}0.499$, $35^{\circ}$ at $1.34{\pm}0.657$, $40^{\circ}$ at $1.84{\pm}0.573$, $45^{\circ}$ at $0.76{\pm}0.649$, and they were significant(P<0.05). The degree of $40^{\circ}$ views were shown to yield good quality shoulder oblique images.

Angled Capillary Method for Determining Erythrocyte Sedimentation Rate of Goat (경사모세관법(傾斜毛細管法)에 의한 산양혈액(山羊血液)의 적혈구침강율(赤血球沈降率) 측정(測定))

  • Shin, Sung-shik;Lee, Bang-whan;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.187-194
    • /
    • 1986
  • The purpose of this study is to develop a new method which enables the goat ESR to be used as an effective clinical test. Blood samples were taken from 61 Korean native goats aged above one year old and the effect of tube inclinations, tube bores, tube lengths, environmental temperatures during tests and packed erythrocyte volumes (PCV) on the ESR were observed. The results were summarized as follows. 1. The ESR/hr using capillary hematocrit tube (Micro-Ht-tube) was gradually increased as the tube angle inclined from 90 (vertical) to 15 degrees and the best angle in view of both security and fast sedimentation rate was found to be an angle of 45 degrees. 2. The 45-degree angled ESR ($45^{\circ}$-ESR) increased as the diameter of tube bore decreased. 3. The tube length did not affect the $45^{\circ}$-ESR in percent. 4. The $45^{\circ}$-ESR increased with the increased environmental temperature during the ESR test. 5. The heparinized Micro-Ht tubes did not affect the $45^{\circ}$-ESR of EDTA-blood in healthy group but in anemic group. In the anemic group, the ESRs by the heparinized Micro-Ht-tubes were slightly higher than those by non-heparinized Micro-Ht-tubes. 6. By using the autologous plasma, PCV of the blood was adjusted to be 10, 20, 30, 40 and 50ml/100ml and $45^{\circ}$-ESRs were determined in the Micro-Ht-tubes. The $45^{\circ}$-ESRs increased as the values of PCV decreased. The regression of the $45^{\circ}ESR$ to PCV was curvilinear with the second degree polynomial, $Y=42.1838-1.7355X+0.0180X^2$(r=0.9997). 7. The $45^{\circ}$-ESR/hr, using non-heparinized Micro-Ht-tubes at $20^{\circ}C$, was determined in 35 healthy Korean native goats. The average PCV was $30.6{\pm}1.4ml/100ml$. The observed ESR values averaged $6.8{\pm}1.7%$ and the corrected ESR values to the standard PCV of 31ml/100ml averaged $6.5{\pm}1.2%$. From these results, the angled capillary tube method was found to be desirable ESR test of goat blood in which EDTA-blood is filled in nonheparinized Micro-Ht-tubes held at an angle of 45 degrees for an hour at $20^{\circ}C$.

  • PDF

The frontal characteristics of esthetic lips and lips after anterior segmental osteotomy in Korean females (정면에서 평가한 한국인 여성 입술의 심미성과 전방 분절 골절단술 후 입술의 평가)

  • Lee, Beom-Suk;Kang, Yoon-Goo;Yoon, Tae-Ho;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.5
    • /
    • pp.331-340
    • /
    • 2007
  • The aim of this study was to determine firstly the characteristics of esthetic lips in Korean females and secondly to measure the changes of the lips before and after anterior segmental osteotomy in bimaxillary protruded patients. Methods: Samples consisted of 30 models and 26 nonmodels, and 10 patients who had received anterior segmental osteotomy. Twelve linear measurements, 5 angular measurements, and the lip perimeter and area were measured. These results were compared for each group using unpaired and paired t-tests. Results: Full face width, nose to chin, upper vermilion height and angle, lateral heights at the point of the tips of Cupid's bow, central bow angle, and the lower lip to chin lengths were significantly greater in nonmodels than in models. However, overall lip width, lower vermilion height and angle, tip-to-tip of Cupid's bow lip perimeter, and lower vermilion area were greater in models than in nonmodels. Comparison of before and after anterior segmental osteotomy revealed that the values for the upper vermilion and lateral heights, the angle to Cupid's bow tip lengths, and upper vermilion area of post-operative patients had become similar to those of Korean female models. Our findings demonstrated that Korean female models have a fuller lower vermilion & thinner upper vermilion compared with nonmodel controls, as determined by the vermilion heights, angles, and areas. Conclusions: It will be helpful for clinicians to use these measurements as guidelines for improving patients' facial esthetics.

Surface Modification of Polymethylmethacrylate(PMMA) by Ion-assisted reaction (이온 보조 반응법(Ion-assisted-reaction)을 이용한 Polymethylmethacrylate (PMMA)의 표면개질)

  • Jung, Sun;Cho, Jun-Sik;Choi, Sung-Chang;Koh, Seok-Keun
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.446-451
    • /
    • 1999
  • Surface of Polymethylmethacrylate (PMMA) was modified by ion assisted reaction in which ion beam of Ar or$ O_2$is irradiated on polymer in reaction gas environment. Ion beam energy was changed from 600 to 1000eV, and ion doses were varied from $5\times10^{14} ions/cm^2 to 1\times10^{17} ions/cm^2$. Contact angle and surface energy of modified PMMA were measured by contact angle micrometer using distilled water and formamide. In the case of $Ar^+$ ion irradiation only, the contact angle reduced from $68^{\circ} to $35^{\circ}$ and the surface energy was changed from 46 dyne/cm to 60 dyne/cm. The contact angle significantly decreased to $14^{\circ}$and the surface energy increased to 72 dyne/cm when the surface of PMMA was modified by oxygen ion irradiation in oxygen gas environment. Improvement of wettability results from the formation of new hydrophilic group which is identified as C-O chain by XPS analysis. Recovery of wettability in dry air and maintenance of it in water condition were explained in view of the formation of hydrophilic group.

  • PDF

A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD (Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구)

  • Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Young-Hyuk;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.467-491
    • /
    • 1995
  • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

  • PDF

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

The Determination of Optimum Beam Position and Size in Radiation Treatment (방사선치료시 최적의 빔 위치와 크기 결정)

  • 박정훈;서태석;최보영;이형구;신경섭
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • New method about the dose optimization problem in radiation treatment was researched. Since all conditions are more complex and there are more relevant variables, the solution of three-dimensional treatment planning is much more complicate than that of current two-dimensional one. There(ore, in this study, as a method to solve three-dimensional dose optimization problem, the considered variables was minized and researched by reducing the domain that solutions can exist and pre-determining the important beam parameters. First, the dangerous beam range that passes critical organ was found by coordinate transformation between linear accelerator coordinate and patient coordinate. And the beam size and rotation angle for rectangular collimator that conform tumor at arbitrary beam position was also determined. As a result, the available beam position could be reduced and the dependency on beam size and rotation angle, that is very important parameter in treatment planning, totally removed. Therefore, the resultant combinations of relevant variables could be greatly reduced and the dose optimization by objective function can be done with minimum variables. From the above results, the dose optimization problem was solved for the two-dimensional radiation treatment planning useful in clinic. The objective function was made by combination of dose gradient, critical organ dose and dose homogeniety. And the optimum variables were determined by applying step search method to objective function. From the dose distributions by optimum variables, the merit of new dose optimization method was verified and it can be implemented on commercial radiation treatment planning system with further research.

  • PDF

Multi-screen Content Creation using Rig and Monitoring System (다면 콘텐츠 현장 촬영 시스템)

  • Lee, Sangwoo;Kim, Younghui;Cha, Seunghoon;Kwon, Jaehwan;Koh, Haejeong;Park, Kisu;Song, Isaac;Yoon, Hyungjin;Jang, Kyungyoon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.5
    • /
    • pp.9-17
    • /
    • 2017
  • Filming using multiple cameras is required for the production of the multi-screen content. It can fill the viewer's field of view (FOV) entirely to provide an increased sense of immersion. In such a filming scenario, it is very important to monitor how images captured by multiple cameras are displayed as a single content or how the content will be displayed in an actual theatre. Most recent studies on creating the content of special format have been focused on their own purposes, such as stereoscopic and panoramic images. There is no research on content creation optimized for theatres that use three screens that are spreading recently. In this paper, we propose a novel content production system with a rig that can control three cameras and monitoring software specialized for multi-screen content. The proposed rig can precisely control the angles between the cameras and capture wide angle of view with three cameras. It works with monitoring software via remote communication. The monitoring software automatically aligned the content in real time, and the alignment of the content is updated according to the angle of camera rig. Futher, the producion efficiency is greatly improved by making the alignment information available for post-production.

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.