• Title/Summary/Keyword: Video quality measurement

Search Result 89, Processing Time 0.024 seconds

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

Implementation of RTP/RTCP for Teleconferencing System and Analysis of Quality-of-Service using Audio Data Transmission (영상회의 시스템을 위한 RTP/RTCP 구현 및 오디오 데이터 전송을 위용한 QoS 분석)

  • Kang, Min-Gyu;Hwang, Seung-Koo;Kim, Dong-Kyoo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3047-3062
    • /
    • 1998
  • This paper deseribes the desihn and the implementation of the Realtime Transport Protocol(RTP)/ Rdaltime Control Protocol(RTCP) (RFC 1889,1890) that is used to transmit the audio/video data to any destination and to feedback the Quality of Service (QoS) information of the received media data to the sender, in the teleconferencing systems proposed by ITU-T. These protocols are implemented with multi thead technique and run on top of UDP/IP-Multicast through the socket interface as the underlying protocol. The upper layer is impelmented such that in can be accessed by the H245 comference control protocol. The RTP packetizes the digitized audio/video data from the encoder info a fixed format, and multieast to the participants. The RTCP monitors RTP packets and extracts the QoS values from it such as round-trip delay, jiter and packet loss to form RTCP packets and non periokically sends them to the sender site. In this Paper, we also descritx the study of measurement and analysis for QoS factors that observed on performing teleconferencing system over Internet. The results from this experiment is indicate that RTT and Jitter value are acceptable even entwork load is high. However, it appears that packet loss rate is high in daytime and most losses periods have length one or two.

  • PDF

Quality Improvement on Upper Gastrointestinal Series (위장조영검사에서 화질 개선 방법)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.395-401
    • /
    • 2016
  • Upper gastrointestinal series is a diagnostic test that X-ray passes through the stomach after administering contrast media such as barium or gastrografin. Upper gastrointestinal series with an advantage of no side effect except temporary constipation or abdominal pain has been widely used to diagnose diseases of the gastrointestinal system. However, image degradation and diagnostic accuracy frequently occurred when improper movement and breath control were carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. The movie of the upper gastrointestinal series was made for improving inspection accuracy and image quality. The examinees encouraged to see the movie for waiting time before doing upper gastrointestinal series. In this study, image quality and diagnostic accuracy was examined for the effect of the movie about upper gastrointestinal series. 60 patients composed of each 10 people from 30s to 80s were selected randomly among both 2,940 examinees in 2014 and 3,076 examinees in 2015. Image quality was evaluated by the full width at half maximum of profile for each image using the Image J. The measurement of the full width at half maximum showed 0.208 mm and 0.133 mm for after and before seeing the movie. Thus it was verified that the movie education could improve the image quality and diagnostic accuracy for upper gastrointestinal series.

An Analysis of Vertical Position Accuracy for the Three-Dimensional Spatial Data Object Utilizing the Public Information (공공데이터를 활용한 3차원 공간정보 객체의 수직위치 정확도 분석)

  • Kim, Jeong Taek;Yi, Su Hyun;Kim, Jong Il;Bae, Sang Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.137-143
    • /
    • 2014
  • Recently, as new paradigm for government operation called government 3.0, government is actively operating policy opening and sharing public data. In addition, the Ministry of Land are operating an open platform integrated map service (the VWorld) which provides a variety of video contents such as the country's national spatial information, traffic information and three-dimensional building for the public. According to W3C Foundation's Open Data Status Report(2013), our country has the evaluated results that the part of the government's policy support and planning is good while the part of the data management is vulnerable. So our country needs the quality improvement for the data management. In addition, a digital aerial photograph image data is required to be up-to-date for the three-dimensional spatial object data. In this paper, we present the method for enhancement of the accuracy of vertical position and for maintainment of up-to-date vertical position. Our methods evaluate the data quality and analyze the cause of error of measurement utilizing the national standard quality assessment method. The result of research shows that the accuracy of vertical position is improved if the height of the building captain is adjusted by the quality assessment values and a three-dimensional model has up-to-date data if reconstruction and extension information of construction register is utilized.

An AP Selection Scheme for Enhancement of Multimedia Streaming in Wireless Network Environments (무선 네트워크 환경에서 멀티미디어 서비스를 위한 AP 선정 기법)

  • Ryu, Dong-Woo;Wang, Wei-Bin;Kang, Kyung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.997-1005
    • /
    • 2010
  • Recently, there has been a growing interest in the use of WLAN technology due to its easy deployment, flexibility and so on. Examples of WLAN applications range from standard internet services such as Web access to real-time services with strict latency/throughput requirements such as multimedia video and voice over IP on wireless network environments. Fair and efficient distribution of the traffic loads among APs(Access Points) has become an important issue for improved utilization of WLAN. This paper focuses on an AP selection scheme for achieving better load balance, and hence increasing network resource utilization for each user on wireless network environments. This scheme makes use of active scan patterns and the network delay as main parameters of load measurement and AP selection. This scheme attempts to estimate the AP traffic loads by observing the up/down delay and utilize the results to maximize the link resource efficiency through load balancing. We compared the proposed scheme with the original SNR(Signal to Noise Ratio)-based scheme using the NS-2(Network Simulation.2). We found that the proposed scheme improves the throughput by 12.5% and lower the network up/down link delay by 36.84% and 60.42%, respectively. All in all, the new scheme can significantly increase overall network throughput and reduce up/down delay while providing excellent quality for voice and video services.

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

A Surface Image Velocimetry Algorithm for Analyzing Swaying Images (흔들리는 영상 분석을 위한 표면 영상 유속계 알고리듬)

  • Yu, Kwonk-Yu;Yoon, Byung-Man;Jung, Beom-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.855-862
    • /
    • 2008
  • Surface Image Velocimetry (SIV) is an instrument to measure water surface velocity by using image processing techniques. To improve its measuring accuracy, it is essential to get high quality images with low skewness. A truck-mounted SIV system would be a good way to get images, since its crane gives high altitude to the images. However, the images taken with a truck-mounted SIV would be swayed due to the movement of crane and the camera by winds. In that case, to analyze the images, it is necessary to compensate the side sway in the images. The present study is to develop an algorithm to analyze the swayed images by combining common image processing techniques and coordinate transform techniques. The system follows the traces of some selected fixed points and calculates the displacements of the video camera. By subtracting the average velocity of the fixed points from that of grid points, the velocity fields of the flow can be corrected. To evaluate the system's performance, two image sets were used, one image set without side sway and another set with side sway. The comparison of their results showed very close with the error of around 6 %.

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

A Study on the Educational Effectiveness of Chronic Diseases Among University Students (일부 대학생들의 성인건강 교육의 효과에 관한 연구)

  • Kang, Hee-Sook;Cho, Hyun
    • Journal of the Korean Society of School Health
    • /
    • v.8 no.1
    • /
    • pp.143-154
    • /
    • 1995
  • Korea has been recently reducing the quality of life as well as rising medical cost because of the increase of chronic diseases. But we can prevent those chronic diseases through the improvement of environment or life style. We evaluated the educational effectiveness of chronic diseases(hypertention, diabetes, cancer, stroke and other chronic diseases) designed to increase the knowledge, attitude and practice of chronic diseases among university students. Between August 1994 and November 1994, we implemented chronic diseases prevention instruction in intervention students; unmatched control students were selected in same university. We conducted pre- and post-intervention surveys both intervention and control students with self-reported questionnaires(50 items). We assigned score(0-4 points) to items and conducted a analysis of covariance(ANCOVA) with sex, grade and economic status as the covariate, using the SAS PC computer statistical package. And we culculated odds ratio with safety scores between intervention and control students. The results of this study were followed. 1. In demographic characteristics of subjects both pre- and post intervention, we found no significant differences in intervention and control students at religion, father's education, mother's education, mother's occupation and type of residence(p>0.05), but we found significant differences at sex(p<0.001), grade(p<0.001) and economic status(p<0.05). 2. The sex, grade and economic status-adjusted mean prevention knowledge scores for diabetes and stroke increased from the pre- to post-survey in the intervention students(p<0.001), but control students did not increased(p>0.05). As odds ratios in knowledge were below 1, the knowledge of intervention students were higher than control students. 3. The attitudes for general adult health increased from the pre- to post-survey in the intervention students(p<0.05), but control students did not increased(p>0.05). As odds ratios in attitudes were approximately 1, we can not say effectiveness in intervention students 4. The pratices for cancer and stroke increased from the pre- to post-survey in both the intervention and control students(p<0.001). Also odds ratio of hypertention was 0.91, and that of stroke was 1.14. 5. Health related behaviors did not increased from the pre- to post- survey in both the intervention and control students(p>0.05). But odds ratio of drinking was 0.76 and that of body weight was 1.21. 6. Health status did not increased from the pre- to post- survey in both the intervention and control students(p>0.05). As odds ratio of health status was 1.09, prevention education was not effect in intervention students We would like to recommend as follows; 1. University students must learn about prevention of chronic diseases. Because the knowledge of invetervention students was higher than that of control students. 2. The prevention education of chronic diseases should be taught from primary school. 3. Adult health education for university students must be practiced continuously. Education period(l5 weeks) in this study was not complete. 4. The evaluation of chronic diseases was conducted real measurement(such as BP check) as well as self reported-survey. 5. Educational materials(video tape, pamphlet) related the prevention of chronic diseases should be developed at national level. And we must easely use those materials. 6. The prevention education of chronic diseases should be made through mass media as well as school education.

  • PDF