• 제목/요약/키워드: Vicker's microhardness

검색결과 17건 처리시간 0.019초

Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.126-131
    • /
    • 2011
  • PURPOSE. The aim of this in vitro study was to examine the curing efficiency of various resin-based materials polymerized through ceramic restorations with 3 different thicknesses. Curing efficiency was evaluated by determining the surface microhardness (VHN) of the resin specimens. MATERIALS AND METHODS. Four kinds of resin materials were used. Z350 (3M ESPE $Filtek^{TM}$ Z350: A2 Shade), Z250 (3M ESPE $Filtek^{TM}$ Z250: A2 Shade) and $Variolink^{(R)}$ II (VL: Ivoclar vivadent, base: transparent) either with or without a self-curing catalyst (VLC: Ivoclar vivadent, catalyst: low viscosity/transparent) were filled into the silicone mold (10 mm diameter, 1 mm thick). They were cured through ceramic discs (IPS e.max Press MO-0 ingot ivoclar vivadent, 10 mm diameter, 0.5, 1 and 2 mm thicknesses) by LED light-curing units for 20 and 40 seconds. Vicker's microhardness numbers (VHNs) were measured on the bottom surfaces by a microhardness tester. Data were analyzed using a 3-way analysis of variance (ANOVA) at a significance level of 0.05. RESULTS. The thickness of ceramic disc increased, the VHNs of all four resin types were decreased (P<.05). The mean VHN values of the resins light cured for 40 seconds were significantly higher than that of LED for 20 seconds in all four resin materials (P<.05). VLC showed significantly higher VHN values than VL regardless of other conditions (P<.05). Z350 and Z250 showed higher values than VL or VLC (P<.01). CONCLUSION. Thinner ceramic disc with increased curing time resulted higher VHN values of all resin materials. The use of a catalyst produced a greater hardness with all polymerization methods. Restorative resin materials (Z350, Z250) showed higher VHN values than resin cement materials (VL, VLC).

4종의 간접법용 복합 레진의 기계적 특성 비교 (COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN)

  • 김길수;윤태호;송광엽;안승근
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

치과용(齒科用) 은(銀)-파라디움합금(合金)의 합금원소(合金元素)가 제성질(諸性質)에 미치는 영향(影響)에 관(關)한 연구(硏究) (EFFECTS OF ALLOYING ELEMENTS ON VARIOUS PROPERTIES OF DENTAL SILVER-PALLADIUM ALLOYS)

  • 김춘진;박남수
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.95-108
    • /
    • 1984
  • Even though the tarnishing and corrosion problems characteristic with dental silver-palladium alloy are not yet fully solved, it is recently widely used because of its low cost. However the effects of major alloying elements on the various properties of this system are not fully understood. The object of this research is to clarify the effects of In and Zn additives on the corrosion and tarnishing resistances and precipitation hardening behavior of this sytem, using electrodynamic polarization, immersion, and Vicker's microhardness test and X-ray diffraction and electron probe micro analysis methods. The obtained results were as follows: I. As indium content is increased, both the corrosion resistance in Cl-solution and microhardness are also increased while the tarnishing resistance is decreased. 2. As Zinc content is increased, the corrosion resistance is decreased, but tarnishing resistance is increased 3. At 70Ag-25Pd-2.5Zn-2.5In composition, the precipitation harding behavior was mot significant. The optimum aging temperature was $450^{\circ}C$ and the time was 2 hrs. The resulting specimen of this work carried 180VHN. 4. Under the heat treatment, the changes in the mechanical property are due to the changes in the shape and composition of dendrite matrix, namely, it is because of the precipitation hardening behavior which has been proved by electron probe micro analysis and optical microscopic finding.

  • PDF

세로머, 세라믹 및 복합레진의 기계적 성질의 비교에 관한 연구 (A COMPARATIVE STUDY ON THE MECHANICAL PROPERTIES OF CEROMER, CERAMIC AND INDIRECT COMPOSITE RESIN)

  • 백정화;박일윤;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.233-239
    • /
    • 1999
  • Recently, a second generation composite resin system(ceromer) was introduced with significantly improved mechanical properties. The purpose of this study was to compare a ceromer with the other restorative materials and to assess its clinical usefulness. In this study, we used four restorative materials : amalgam (BESTALOY$^{(R)}$), indirect composite resin (Clearfil CR Inlay$^{(R)}$), ceromer (Targis$^{(R)}$) and ceramic (Vintage$^{(R)}$). And then we devided into four groups. The materials of each group were as follows : Amalgam group : BESTALOY$^{(R)}$ (Dong Myung Dental Industrial Co.) Composite Resin group : Clearfil CR Inlay$^{(R)}$ (Kuraray) Ceromer group : Targis$^{(R)}$ Dentin (Ivoclar-Vivadent) Ceramic group : Vintage$^{(R)}$ (Shofu Inc.) According to the above classification, we made samples through the polymerization of BESTALOY$^{(R)}$, Clearfil CR Inlay$^{(R)}$ and Targis$^{(R)}$ with separable cylindrical metal mold and firing of Vintage$^{(R)}$ in a investment mold. And then, we measured and compared the value of compressive strength, diametral tensile strength and Vicker's microhardness of each sample. The results were as follows : 1. Amalgam showed the highest value of compressive strength (390.37${\pm}$42.22MPa) and the value of ceromer was somewhere between ceramic and indirect composite resin. There were significant differences among the experimental groups(p<0.001). 2. Indirect composite resin showed the highest value of diametral tensile strength (74.21${\pm}$15.33MPa) and there was no significant difference with ceromer. Ceromer was higher diametral tensile strength than amalgam and ceramic (p<0.001). 3. Ceramic showed the highest value of microhardness (538.44${\pm}$37.38Hv) and the value of ceromer was somewhere between ceramic and indirect composite resin. There were significant differences among the experimental groups (p<0.001).

  • PDF

불소 바니쉬가 인공 우식 병소의 발생에 미치는 영향 (EFFECT OF FLUORIDE VARNISH ON DEVELOPMENT OF ARTIFICIAL CARIES)

  • 조난주;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.613-622
    • /
    • 2007
  • 본 연구의 목적은 법랑질 시편에 수종의 불소 제재를 도포한 후 우식 예방 효과를 광밀도 및 미세경도 측정을 통해 평가하는 것이다. 소의 절치를 이용하여 80개의 법랑질 시편을 제작하고 각 군당 20개씩, 네 군으로 나누었다. I군은 대조군으로서 아무런 처치도 하지 않았고 II군은 acidulated phosphate fluoride(APF) gel(60 seconds $taste^{(R)}$, PASCAL, USA)을 4분간 적용한 후 수세하였다. III군은 Fluor $Protector^{(R)}$(Ivoclar Vivadent, Liechtenstein)를, IV군은 $CavityShield^{TM}$(Omnii Pharmaceuticals, USA)를 1분간 도포하고 증류수에 보관한 뒤 24시간 후 부드러운 모를 가진 칫솔을 이용하여 칫솔질하였다. 각 시편을 인공우식용액에 48시간동안 침잠시켜 인공우식병소를 유발한 후 광밀도를 컴퓨터 영상분석 프로그램으로 분석하고 표면미세경도를 측정하여 다음의 결과를 얻었다. 1. 광밀도는 APF gel을 도포한 II군에 비해 불소 바니쉬를 도포한 III, IV군이 높았으나(p<0.05) III군과 IV군 사이의 유의한 차이는 없었다. 2. 표면미세경도는 IV군, III군, II군, I군의 순으로 높았다(p<0.05). 3. $CavityShield^{TM}$를 도포한 IV군과 Fluor $Protector^{(R)}$를 도포한 III군은 광밀도에서는 유의한 차이가 없었으나 표면 미세경도는 IV군이 III군보다 유의하게 높았다. 이상의 결과를 종합해 볼 때 불소 바니쉬가 APF gel에 비해 법랑질 탈회 억제 효과가 우수한 것으로 나타났다. 임상적용의 용이성과 안전성을 고려할 때 불소 바니쉬의 사용이 영유아나 장애인에게 유용할 것으로 사료된다.

  • PDF

치면열구전색제와 유동성 복합 레진의 미세 경도 및 표면 조도의 비교 (MICROHARDNESS AND SURFACE ROUGHNESS OF SEALANT AND FLOWABLE COMPOSITE RESINS)

  • 양규호;최남기;김선미;최지은
    • 대한소아치과학회지
    • /
    • 제36권3호
    • /
    • pp.440-447
    • /
    • 2009
  • 본 연구는 예방적 레진 수복술에 전통적으로 사용되던 소와열구 전색제를 대신하여, 유동성 복합 레진이 사용될 경우의 타당성을 검토하기 위해 시행되었다. 비커스 미세경도를 측정하기 위해 직경 10 mm, 높이 3 mm인 11개의 시편을 제작하여 비커스 미세경도 측정기(FM-7, FUTURE-TEC Inc., Japan)를 이용하여 압입하중 50 gf, 유지시간 15초의 조건 하에서 측정하여 각 군의 평균값을 산출하였다. 표면조도를 측정하기 위해 칫솔마모시험기(Toothbrush abrasive machine K236, Tokyo Machine Co., Japan)로 4개의 시편 표면에 200 rpm의 속도로 4000회의 칫솔질을 시행한 뒤 표면조도형상측정기(Form Talysurf series 2, Rank Taylor Hobson Co., England)를 이용해 표면조도를 측정하였다. ${\alpha}$=0.05의 유의 수준에서 Kruskal-Wallis rank test와 Mann-Whitney U test를 사용하였다. 또한 주사전자현미경으로 관찰하여 각 군의 마모 양상을 비교하여 다음과 같은 결론을 얻었다. 1. 비커스 미세경도 측정 결과 Filtek Z350 flowable (3M ESPE, U.S.A), Palfique Estelite LV (Tokuyama Dental, Japan), Ultraseal XT plus (Ultradent, U.S.A) 순으로 높게 나타났으며 모든 군 간에 통계적으로 유의한 차이가 있었다(p<0.0001). 2. 표면 조도 측정 결과, $Ultraseal^{(R)}$, $Estelite^{(R)}$, $Z350^{(R)}$ 순으로 높게 나타났으나 통계적으로 유의한 차이는 없었다(p=0.116). 3. 마모되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰한 결과, 전색제인 Ultraseal XT plus와 유동성 복합레진인 Palfique Estelite LV, 나노필러를 함유한 유동성 복합레진인 Filtek Z350 flowable이 서로 다른 마모 양상이 나타나는 것을 볼 수 있었다. 이상의 결과를 토대로 할 때, 유동성 복합 레진이 전색제에 비해 물성 적 측면에서 더 우수한 것으로 나타났다.

  • PDF

반복 사용된 IPS Empress 2의 표면경도와 pressing accuracy에 관한 연구 (SURFACE HARDNESS AND PRESSING ACCURACY OF REUSED IPS EMPRESS 2)

  • 손외수;김유리;이경자;진태호
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.596-605
    • /
    • 2003
  • Statement of problem : IPS Empress2 system was developed and used in prosthodontic treatment, but the cost of ingot is expensive for wide application. Purpose : This study was to investigate the possibility on recycling of IPS Empress 2 ceramic for wide application of IPS Empress 2 ceramic in prosthodontic treatment. Material and Method : 1st, 2nd and 3rd pressed disc-shaped($10{\times}1.5mm$) IPS Empress 2 specimens were made with IPS Empress ingot(200, Ivoclar, Liechtenstein) and pressing furnace(IPS Empress EP 500, Ivoclar, Liechtenstein). Vicker's surface hardness and fracture toughness, acid resistance, and pressing accuracy of IPS Empress 2 ceramic were measured and analyzed. Surface hardness was measured by microhardness tester(MTX 70. Matsuzawa, Japan), before and after surface treatment with 0.5% hydrofluoric acid and carbonic acid(Coca cola) for evaluation of acid resistance. Results : The surface hardness of 1st pressed specimen was the higher(5.11 GPa) than those of 2nd pressed(4.89 GPa) and 3rd pressed specimen(4.86 GPa), and the fracture toughness of 1st pressed ($1.58MPam^{1/2}$) and 2nd pressed specimen($1.51MPam^{1/2}$) were higher than that of 3rd pressed specimen($1.39MPam^{1/2}$). The changes of surface hardness of 1st, 2nd, and 3rd pressed specimens after treatment with fluoric acid were 0.17, 0.06, 0.05 (GPa) respectively, and those of 1st, 2nd, and 3rd pressed specimens after treatment with carbonic acid were 0.07, 0.00, 0.05(MPa) respectively. The pressing accuracy of 1st,2nd and 3rd specimen were 77.22%, 85.681%, and 75.05%. The pressing accuracy of 2nd pressed specimen was higher than that of the 3rd specimen. Conclusion : The changes of physical properties according to recycling of IPS Empress 2 from this study were insignificant. Therefore the possibility of recycling of IPS Empress 2 can be suggested from the results.