• Title/Summary/Keyword: Vicker's microhardness

Search Result 17, Processing Time 0.03 seconds

A COMPARATIVE STUDY ON THE MECHANICAL PROPERTIES OF CONDENSABLE COMPOSITE RESINS (응축형 복합레진의 기계적 성질에 관한 비교연구)

  • 정지아;문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.485-491
    • /
    • 2001
  • The purpose of this study was to compare the mechanical properties of three condensable composite resins and one hybrid composite resin. The compressive strength, diametral tensile strength, Vicker's microhardness were tested for mechanical properties of condensable composite resins (SureFil, Ariston pHc, Synergy compact), and hybrid composite resin (Z 100). The tested materials were divided into four groups: control group Z 100 (3M Co. USA), experimental group I Ariston pHc, (Vivadent, Co., Liechtenstein) experimental group II SureFil (Dentsply, Co., U.S.A.), experimental group III Synergy Compact (Coltene, Co., Swiss). According to the above classification, we made samples of SureFil, Ariston pHc, Synergy Compact, Z 100 with separable cylindrical metal mold. And then, we measured and compared the value of compressive strength, diametral tensile strength and Vicker's microhardness of each sample. (omitted)

  • PDF

Effect of Ultrasound on the Mechanical Properties of Electrodeposited Ni-SiC Nano Composite

  • Gyawali, Gobinda;Lee, Su-Wan;U, Dong-Jin;Lee, Han-Yong;Jo, Seong-Hun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.26.1-26.1
    • /
    • 2010
  • Ni-SiC nano composite coatings were fabricated using electrodeposition technique with the aid of ultrasound. The properties of the nano composite were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. The results demonstrated that the microhardness of composite coatings under ultrasonic condition was improved significantly as compared to conventional electrodeposition techniques without ultrasound. The nano particles were found to be distributed homogeneously with reduced agglomeration. The synergistic combination of superior wear resistance and improved microhardness was found in ultrasonicated conditions to the Ni-SiC nano composite coatings.

  • PDF

Mechanical and Tribological Properties of Pulse and Direct Current Electrodeposited Ni-TiO2 Nano Composite Coatings

  • Gyawali, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.6
    • /
    • pp.283-288
    • /
    • 2010
  • Ni-$TiO_2$ nano composite coatings were fabricated using pulse current electrodeposition technique at 100 Hz pulse frequency with a constant 50% pulse duty cycles and reference was taken with respect to the direct current (dc) electrodeposition. The properties of the composite coatings were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. Pulse electrodeposited composite has exhibited enhancement of (111), (220), and (311) diffraction lines with an attenuation of (200) line. The results demonstrated that the microhardness of composite coatings under pulse condition was significantly improved than that of pure nickel coating as well as dc electrodeposited Ni-$TiO_2$ composite coatings. Wear tracks have shown the less plastic deformation in pulse plated composite. Coefficient of friction was also found to be lower in pulse plated composite coatings as compared to dc plated composite coatings.

Mechanical properties of porcelain fused gold alloy containing indium, tin and copper (인듐, 주석, 동 첨가에 따른 도재소부용 금합금의 기계적 특성 변화)

  • Nam, Sang-Yong;Kwak, Dong-Ju;Lee, Deok-Su
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.65-71
    • /
    • 2002
  • This study was performed to observe the microhardness change of the surface and the bonding strength between the porcelain and alloy specimens in order to investigate the effects of appended indium, tin and copper on interfacial properties of Au-Pd-Ag alloys. The hardness of castings was measured with a micro-Vicker's hardness tester. The interfacial shear bonding strength between alloy specimen and fused porcelain was measured with a mechanical testing system(MTS 858.20). The microhardness of Au-Pd-Ag alloy was increased by adding indium and tin, but not increased by adding copper. The shear bonding strength of Au-Pd-Ag-Sn alloy and Au-Pd-Ag-Cu alloy showed 87MPa, 57MPa. The higher concentration of adding elements showed the higher shear bonding strength.

  • PDF

Effect of Plating Parameters on the Electrodeposition of Ni-alumina Nanocomposite

  • Gyawalia, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • $Ni-Al_2O_3$ nanocomposite coatings were fabricated by conventional electrodeposition technique using nickel sulfamate bath. Effect of plating parameters on electrodeposition of $Ni-Al_2O_3$ nanocomposite were studied. The properties of the nano composite were investigated by using SEM, XRD, and Vicker's microhardness test. The results demonstrated that $Al_2O_3$ incorporation in the composite coatings was found to be increased by increasing stir rate and $Al_2O_3$ content in plating bath. Microhardness of the composite coatings was also increased with increasing content of the nano particles in the plating bath. The surface morphologies of the nanocomposite coatings were found to be varied with varying pH, current densities as well as alumina content in the plating bath.

Pulse electrodeposition and characterization of Ni-$TiO_2$ nano composite coatings

  • Cho, Sung-Hun;Gyawali, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.153-153
    • /
    • 2011
  • Ni $TiO_2$ nano composite coatings were fabricated by using pulse current electrodeposition technique at 100 Hz pulse frequency with a constant 50% pulse duty cycles and reference was taken with respect to the direct current electrodeposition. The properties of the composite coatings were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. XRD patterns of pulse deposited composite coatings were found to be changed from preferred (100) orientation to the random mixed orientations. The results demonstrated that the Vickers microhardness of composite coatings under pulse condition was significantly improved than that of pure nickel coating as well as direct current electrodeposited Ni-$TiO_2$ composite coatings. Wear tracks have shown the less plastic deformation at pulse condition with reduced coefficient of friction. Nickel matrix grain size was also found to be lower in pulse plated composite coatings as compared to direct current electrodeposited composite coatings.

  • PDF

Evaluation of softening ability of Xylene & Endosolv-R on three different epoxy resin based sealers within 1 to 2 minutes - an in vitro study

  • Shenoi, Pratima Ramakrishna;Badole, Gautam Pyarelal;Khode, Rajiv Tarachand
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.17-23
    • /
    • 2014
  • Objectives: This study evaluated the efficacy of Endosolv-R and Xylene in softening epoxy resin based sealer after 1 to 2 min exposure. Materials and Methods: Sixty Teflon molds ($6mm{\times}1.5mm$ in inner diameter and depth) were equally divided into 3 groups of 20 each. AH 26 (Dentsply/De Trey), AH Plus (Dentsply/De Trey), Adseal (Meta-Biomed) were manipulated and placed in the molds allotted to each group and allowed to set at $37^{\circ}C$ in 100% humidity for 2 wk. Each group was further divided into 2 subgroups according to the solvents used, i.e. Xylene (Lobachemie) and Endosolv-R (Septodont). Specimens in each subgroup were exposed to respective solvents for 1 and 2 min and the corresponding Vicker's microhardness (HV) was assessed. Data was analysed by Mauchly's test and two-way analysis of variance (ANOVA) with repeated measures, and one-way ANOVA. Results: Initial hardness was significantly different among the three sealers with AH Plus having the greatest and Adseal having the least. After 2 min, Xylene softened AH Plus and Adseal sealer to 11% and 25% of their initial microhardness, respectively (p < 0.001), whereas AH 26 was least affected, maintaining 89.4% of its initial microhardness. After 2 min, Endosolv-R softened AH 26, AH Plus and Adseal to 12.7, 5.6 and 8.1% of their initial microhardness, respectively (p < 0.001). Conclusions: Endosolv-R was a significantly more effective short term softener for all the tested sealers after 2 min whereas Xylene was an effective short term softener against AH plus and Adseal but less effective against AH 26.

Temperature and Dependence of the Microhardness of Rhenium Sheets (리늄판의 미세경도 온도 및 응력의존성)

  • Yun, Seok-Yeong;Lagerlof, K.P.D.
    • Korean Journal of Materials Research
    • /
    • v.10 no.5
    • /
    • pp.335-342
    • /
    • 2000
  • The microhardness of rhenium sheets was determined as a function of indentation load and temperature. The temperature dependence of the microhardness between room temperatures and $1000 ^{\circ}C$was studied using a hot microhardness tester equipped with a Vickers indenter. The load dependence of the microhardness was investigated using oth a Vickers and a Knoop indenter. The indentation size effect (ISE) was well explained using the normalized Meyers law. The hardness of the annealed rhenium sheet approached that of the as-rolled sheets at large indentation loads because of work-hardening under the indenter during indentation. The hardness at zero load(obtained from extrapolation of the load dependence of the hardness) suggested that the hardness is controlled by two different mech-anisms having different thermal activation. At low temperature the activation energy for the mechanism controlling the hardness was approximately 0.02 eV , Whereas at higher temperatures that was approximately 0.15eV. The tranisi-tion temperature between the two different controlling mechanisms was about $250^{\circ}C$.

  • PDF

Crystal Growth, Spectral, Magnetic, Antibacterial and Antifungal Studies of Co(II) and Ni(II) Complexes of 4-Nitrobenzoic Acid

  • Roy, Sunalya M.;Sudarsanakumar, M.R.;Dhanya, V.S.;Suma, S.;Kurup, M.R. Prathapachandra
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.3
    • /
    • pp.258-266
    • /
    • 2014
  • Single crystals of cobalt(II) and nickel(II) complexes of 4-nitrobenzoic acid have been successfully grown by gel diffusion technique. The grown crystals were characterized by elemental analysis, FT-IR and UV-Visible spectroscopy. The structure of the grown crystals was elucidated using single crystal X-ray diffraction studies. The title compounds $[Co(Pnba)_2(H_2O)_4]{\cdot}2H_2O$ 1 and $[Ni(Pnba)_2(H_2O)_4]{\cdot}2H_2O$ 2 where PnbaH=4-nitrobenzoic acid, crystallize in centrosymmetric triclinic space group P-1. Magnetic susceptibility measurements reveal that the compounds are paramagnetic in nature. The mechanical strength of the grown crystals was determined by Vicker's microhardness studies. The ligand (4-nitrobenzoic acid) and the complexes have been screened for their biological activity against various bacteria and fungi. The activity data show that the biological activity of the complexes is higher than that of the ligand.

Duplex Surface Modification with Micro-arc Discharge Oxidation and Magnetron Sputtering for Aluminum Alloys

  • Tong, Honghui;Jin, Fanya;He, Heng
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.21-27
    • /
    • 2003
  • Micro-arc discharge oxidation (MDO) is a cost-effective plasma electrolytic process which can be used to improve the wear and corrosion resistance of Al-alloy parts by forming a alumina coating on the component surface. However, the MDO coated Al-alloy components often exhibit relatively high friction coefficients and low wear resistance fitted with many counterface materials, additionally, the pitting corrosion for the MDO coated AI-alloy components, especially for a thinner alumina coating, often occurs in atmosphere circumstance due to the porous alumina coats. Therefore, a duplex treatment, combining a MDO coated ahumina thin layer with a TiN coating, prepared by magnetron sputtering (MS), has been investigated. The Vicker's microhardness, pin-on-disc, electrochemical measurement, salt spray, XRD and SEM tests were used to characterize and analyze the treated samples. The work demonstrates that the MDO/MS coated samples have a combination of a very low friction coefficient and good wear resistance as well as corrosion since the micro-holes on alumina coating are partly or fully covered by TiN material.