• Title/Summary/Keyword: Vibrator

Search Result 296, Processing Time 0.02 seconds

A Driver's Condition Warning System using Eye Aspect Ratio (눈 영상비를 이용한 운전자 상태 경고 시스템)

  • Shin, Moon-Chang;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.349-356
    • /
    • 2020
  • This paper introduces the implementation of a driver's condition warning system using eye aspect ratio to prevent a car accident. The proposed driver's condition warning system using eye aspect ratio consists of a camera, that is required to detect eyes, the Raspberrypie that processes information on eyes from the camera, buzzer and vibrator, that are required to warn the driver. In order to detect and recognize driver's eyes, the histogram of oriented gradients and face landmark estimation based on deep-learning are used. Initially the system calculates the eye aspect ratio of the driver from 6 coordinates around the eye and then gets each eye aspect ratio values when the eyes are opened and closed. These two different eye aspect ratio values are used to calculate the threshold value that is necessary to determine the eye state. Because the threshold value is adaptively determined according to the driver's eye aspect ratio, the system can use the optimal threshold value to determine the driver's condition. In addition, the system synthesizes an input image from the gray-scaled and LAB model images to operate in low lighting conditions.

Generating Characteristics of EYE-type Piezoelectric-generator Using Tension (장력을 이용한 EYE-type 압전 발전기의 출력 특성)

  • Ha, Yong Woo;Jeong, Sung Su;Kim, Na Lee;Kim, Myong Ho;Kang, Shin Chul;Park, Tae Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.635-639
    • /
    • 2013
  • Generating output characteristics of a EYE-type piezoelectric generator depending on ceramic size and materials of the elastic body were studied. EYE-type piezoelectric-generating device consist of the ceramic was attached between the both elastic body. piezoelectric-generating is that if the tension occurred at both ends of an elastic body, the piezoelectric effect occurs at ceramics through the form change of the elastic body. The structure of this EYE-type generator use various area. than a existing type generator, because the ceramic position of the directly force at does not apply. Resonance and output characteristics of the generator were analyzed by using FEM program. Generators were fabricated on the basis of analyzed results and attached on a frequency controllable vibrator to measure output characteristics. Also, the experimental results were compared with the simulated results. As a result, output characteristics of the generator increased depending on the increase in ceramic thickness. In case of increase in ceramic width, resonance frequency of the generator also decreased.

Suggestion of separation and recollection method of nano particles from suspension by using ultrasonic atomization (초음파 무화효과를 이용한 현탁액으로부터 나노입자의 분리포집법 제안)

  • Kim, Jihyang;Kim, Jungsoon;Yeom, Jiyeong;Ha, Kanglyeol;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.445-451
    • /
    • 2016
  • It is very important to obtain non-agglomerated nano particle state for practical application of nano technology. In order to improve the functionality of products using nano particles, more precise control of particle size distribution is required in their synthesis process. However, synthesized nano particles are agglomerated easily due to physical and chemical reasons, and it then veils unique properties of the nano particles and causes some troubles in their practical application. In this study, a separation method for nano particles from suspension by using the droplets as the separation space was proposed. Using the suspension of 0.002 wt. % with $TiO_2$ powder, the particle size distribution of nano particles in the recollected suspension was measured. From the results, it was confirmed that it is possible to separate and to recollect the nano particles monodispersed by using the suggested method.

Theoretical and experimental serviceability performance of SCCs connections

  • Maghsoudi, Ali Akbar
    • Structural Engineering and Mechanics
    • /
    • v.39 no.2
    • /
    • pp.241-266
    • /
    • 2011
  • The Self Compacting Concrete, SCC is the new generation type of concrete which is not needed to be compacted by vibrator and it will be compacted by its own weight. Since SCC is a new innovation and also the high strength self compacting concrete, HSSCC behavior is like a brittle material, therefore, understanding the strength effect on the serviceability performance of reinforced self compacting concretes is critical. For this aim, first the normal and high strength self compacting concrete, NSSCC and HSSCC was designed. Then, the serviceability performance of reinforced connections consisting of NSSCC and HSSCC were investigated. Twelve reinforced concrete connections (L = 3 m, b = 0.15 m, h = 0.3 m) were simulated, by this concretes, the maximum and minimum reinforcement ratios ${\rho}$ and ${\rho}^{\prime}$ (percentage of tensile and compressive steel reinforcement) are in accordance with the provision of the ACI-05 for conventional RC structures. This study was limited to the case of bending without axial load, utilizing simple connections loaded at mid span through a stub (b = 0.15 m, h = 0.3 m, L = 0.3 m) to simulate a beam-column connection. During the test, concrete and steel strains, deflections and crack widths were measured at different locations along each member. Based on the experimental readings and observations, the cracked moment of inertia ($I_{cr}$) of members was determined and the results were compared with some selective theoretical methods. Also, the flexural crack widths of the members were measured and the applicability for conventional vibrated concrete, as for ACI, BS and CSA code, was verified for SCCs members tested. A comparison between two Codes (ACI and CSA) for the theoretical values cracking moment is indicate that, irrespective of the concrete strength, for the specimens reported, the prediction values of two codes are almost equale. The experimental cracked moment of inertia $(I_{cr})_{\exp}$ is lower than its theoretical $(I_{cr})_{th}$ values, and therefore theoretically it is overestimated. Also, a general conclusion is that, by increasing the percentage of ${\rho}$, the value of $I_{cr}$ is increased.

Gender Differences in the Sensitivity and Displeasure Caused by the Vibration Stimuli Applied to the Forearm in Upper Limb Amputees

  • Kim, Sol Bi;Ko, Chang-Yong;Chang, Yun Hee;Kim, Gyoo Suk;Kim, Sin Ki
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.355-361
    • /
    • 2013
  • Objective: The aim of this study is to investigate the gender-differences in vibrotactile responses(sensitivity and displeasure) of residual forearm simulated by vibration stimulation in upper limb(trans-radial) amputees. Background: Several studies have reported that vibration stimulation using the haptic vibrator is one the most effective methods for delivering sensation to an amputees. However, few studies have reported the perception to haptic vibratory stimulus, particularly sensitivity and displeasure. Method: We set up a custom-made vibration stimulation system that included 6 actuators(3 medial parts and 3 lateral parts) and a graphical user interface(GUI)-based acquisition system to investigate changes in residual somatosensory sensibility and displeasure in the forearm of upper limb(trans-radial) amputees. Vibration actuators were attached at the 25%-point on the proximal forearm. Stimulation with 32Hz, 64Hz, or 149Hz of frequency was used for the sensitivity tests and with 32~257Hz of frequency was used for the discomfort experiments. The subjective responses were evaluated on a 10 point scale. Results: The results showed that vibrotactile sensory perception in male amputees were higher than that in female amputees. In male amputees, the response at lateral area of forearm was the most sensitive than medial area; but, female amputees showed similar sensitive areas. Subjects did not experience any discomfort during vibrotactile stimuli. Conclusion: Vibrotactile response in the amputees was dependent on gender as well as area stimulated by vibration. Application: The results might contribute to develop the vibrotactile feedback system for the amputees.

The Formation Mechanism Synthesizing of $SrTiO_3$Fine Powders by Ultrasonic Spray Pyrolysis (초음파 분무 열분해법에 의한 $SrTiO_3$ 미분말 합성시 그 형성 과정에 관하여)

  • 허화범;이동주;신건철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.2 no.2
    • /
    • pp.11-19
    • /
    • 1992
  • $SrTiO_3$powders were synthesized from the chloride and the nitrate aqueous solution by spray pyrolysis method using ultrasonic vibrator. The concentration of mother solution was prepared 0.05M and O.lM. The carrier gas flow rate was 0.5cm/sec and 1.5cm/sec, respectively. The formation processing was investigated in the 0.05M and 0.05cm/sec. The $SrTiO_3$powders could not be synthesized from chloride aqueous solution. The prepared powders from nitrate aqueous solution was SrTi03 with cubic structure and nearly sphere particle for all samples. Mean particle size was increased from $0.49{\mu}m$ to $0.67{\mu}m$ by changing the carrier gas flow rate from O.5cm/sec to 1.5cm/sec. Also, mean particle size increased from $0.49{\mu}m$to $0.55{\mu}m$by changing the concentration of mother solution from O.05M to O.1M. Atomizing droplet size was $14.3{\mu}m$. The shape of particles was very porous by evaporation of solvent at the initial step. But through the each step upwards, shape of particles was formed themselves into a nearly roundish.

  • PDF

A Machine-to-machine based Intelligent Walking Assistance System for Visually Impaired Person (시각장애인을 위한 M2M 기반의 지능형 보행보조시스템)

  • Kang, Chang-Soon;Jo, Hwa-Seop;Kim, Byung-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.287-296
    • /
    • 2011
  • The white stick mainly used for visually impaired person has difficulty in providing location information and effective countermeasures for emergency situations encountered during walking as well as detecting floating obstacles on the ground. In this paper, we propose a machine-to-machine based intelligent walking assistance system for safe and convenient walking of the visually impaired. The proposed system consists of a walking assistance stick used by the visually impaired and a server supporting multiple stick users in remote places through mobile communication networks. The stick equipped with ultrasonic sensors, GPS(global positioning system) receiver and vibrator not only detects floating obstacles, but also offers stick users with present location identification utilizing a text-to-voice conversion technology. Besides providing geographic information, the server notifies the emergency locations of users to guardian and aid agency, and it provides log information during walking such as the place, time and the number of accidents. Test results with a developed prototype system have shown that the system properly performs the functions and satisfies overall system performance.

The Design of Temporal Bone Type Implantable Microphone for Reduction of the Vibrational Noise due to Masticatory Movement (저작운동으로 인한 진동 잡음 신호의 경감을 위한 측두골 이식형 마이크로폰의 설계)

  • Woo, Seong-Tak;Jung, Eui-Sung;Lim, Hyung-Gyu;Lee, Yun-Jung;Seong, Ki-Woong;Lee, Jyung-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.144-150
    • /
    • 2012
  • A microphone for fully implantable hearing device was generally implanted under the skin of the temporal bone. So, the implanted microphone's characteristics can be affected by the accompanying noise due to masticatory movement. In this paper, the implantable microphone with 2-channels structure was designed for reduction of the generated noise signal by masticatory movement. And an experimental model for generation of the noise by masticatory movement was developed with considering the characteristics of human temporal bone and skin. Using the model, the speech signal by a speaker and the artificial noise by a vibrator were supplied simultaneously into the experimental model, the electrical signals were measured at the proposed microphone. The collected signals were processed using a general adaptive filter with least mean square(LMS) algorithm. To confirm performance of the proposed methods, the correlation coefficient and the signal to noise ratio(SNR) before and after the signal processing were calculated. Finally, the results were compared each other.

Effects of the Vibration Stress on Cortisol and Hematological Characteristics in Soft-shelled Turtle, Pelodiscus sinensis (진동 스트레스에 따른 자라, Pelodiscus sinensis의 코티졸 및 혈액학적 특성)

  • Hur, Jun-Wook;Lee, Jeong-Yeol;Chang, Young-Jin;Bai, Sung-Chul;Park, In-Seok
    • Development and Reproduction
    • /
    • v.13 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • We examined the effects of the vibration stress on cortisol secretion and hematological characteristics in soft-shelled turtle, Pelodiscus sinensis. For the stressed group vibration of $45{\sim}78 dB(V)$ from electric vibrator applied for 30 min with 2-h intervals during daytime ($08:00{\sim}18:00$) up to 28 days. Using the blood samples collected from ten turtles held once a week after vibration stress, we measured hematocrit, hemoglobin, red blood cells, cortisol, glucose, lactic acid, osmolality, $Na^+,\;K^+,\;Cl^-$, aspartate aminotransferase (AST), and alanine aminotransferase (ALT). The results have showed that P. sinensis received vibration stress exhibit the 'typical' stress-induced physiological responses (cortisol, glucose, lactic acid, osmolality, ions, hematocrit and hemoglobin) induced by vibration stress. Our data suggested that chronic vibration stress caused substantial stress in the animal, and in particular, the persisting elevated levels of AST and ALT would be highly correlated with the adverse effects of the stress. The high hematological characteristics during entire experimental period showed that the P. sinensis could not adapt to chronic stimuli provoked by vibration stress.

  • PDF

Suggestion of an experimental method for optimization of flange point of a bolt-clamped Langevin-type ultrasonic transducer (볼트 체결형 란주반 초음파 트랜스듀서의 프렌지 포인트 최적화를 위한 실험적 방법 제안)

  • Kim, Jungsoon;Kim, Haeun;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.270-277
    • /
    • 2021
  • In the power ultrasound fields, the flange position for fixing the transducer is an important factor influencing on electro-mechanical efficiency of the transducer. We suggested a practical method that can determine the installation position of the flange for different resonance modes of the bolt-clamped type Langevin ultrasonic transducer. A semicircular wedge-shaped jig was manufactured and moved along the lateral surface of the transducer. The vibration characteristics were examined after a constant pressure was applied to the semicircular wedge-shaped jig. By observing the change of the input admittance of the transducer depending on the position of the pressure application, the optimum position for the flange installation could be determined. The resonant modes of the transducer were calculated by a Mason's equivalent circuit, and the particle velocity distribution for each resonance mode was calculated by a transmission line model. Since the optimum positions determined from an experimental result show a good correspondence with the node positions of the vibration modes calculated by the transmission line model, the validity of the suggested method was verified.