• Title/Summary/Keyword: Vibration test

Search Result 3,753, Processing Time 0.029 seconds

발전소 주변압기 운전중 진동 기준치 설정에 관한 연구

  • Lee, W.R.;Lee, J.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.587-592
    • /
    • 2005
  • Main transformer's integrity assessment in nuclear power plant is estimated by the electrical test of electrical core and wire and the chemical analysis of insulating oil. Mechanical test or analysis has not been so far. So this study makes it with the vibration velocity rating. The vibration velocity rating in main transformer which is based on the real data of vibration velocity measurement under operating and other machinery vibration code such as ISO code is renewed.

  • PDF

Progress in Developing the 6-DOF Vibration Environmental Simulator (진동 환경 재현 6-자유도 가진기 개발 진척도)

  • 정완섭;우춘규;김수현;윤각진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.296-301
    • /
    • 1998
  • In this experiments of design, vibration evaluation, and test of vehicles, aircraft, and other mechanisms the development of vibration simulator that serves environment similar to real fields takes lots of advantages. Especially, in the real field test of vehicles it possesses the advantages of showing the dynamic characteristics of the vehicle. In this study, to investigate the validity and fitness of proposed 6DOF parallel link mechanism we simulated that mechanism.

  • PDF

Signal Processing for Multiaxial Vibration Fatigue Test on Vehicle Component (자동차 부품에 대한 다축 진동내구 시험용 신호처리 방법)

  • Bae, Chul-Yong;Kim, Chan-Jung;Lee, Dong-Won;Lee, Bong-Hyun;Na, Byung-Chul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.368-374
    • /
    • 2008
  • Multi-axial simulation table(MAST) is widely used in motor companies as the multi-axial excitor for vibration fatigue of target component, which provides the vibrational condition as close as the vehicle test. However, the vibration fatigue performance of target component can be guaranteed with MAST system only in case the input profile covers the required severity of the target component on field test. In this paper, the signal processing for multi-axial vibration fatigue test on vehicle component is presented, from the data acquisition of the target component to the derivation of input profile. To compare the severity of vibration condition between field and proving ground, the energy principle of a equivalent damage is proposed and then, it is determined the optimal combination of special events on proving ground using a sequential searching optimal algorithm. To explain the vibration methodology clearly, seat and door component of vehicle are selected as a example.

Prediction of Blasting-induced Vibration at Sintanjin Area, Daejeonusing Borehole Test Blasting (시추공 시험발파를 이용한 대전 신탄진 지역의 발파진동 예측)

  • Lee, Chung-Won;Park, Sung-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.4
    • /
    • pp.55-62
    • /
    • 2018
  • Problems on vibration due to blasting for infrastructure development are getting important because of a civil appeal. Blasting-induced vibration is representative construction pollution, hence, it is possible that a number of environmental damages occur. In this study, borehole test blasting was conducted at Sintanjin area, Daejeon and square root equation with 95% confidence level was proposed for prediction of blasting-induced vibration. The vibration value predicted from this equation was more conservatively evaluated than the values predicted from U.S. Department of Interior, Bureau of Mines (USBM) and Nippon Oil & Fats Co., Ltd. (NOF) equations. Therefore, the proposed equation in this study seems to contribute for safety blast design. However, for optimal blast design, inducing equation for prediction of blasting-induced vibration through the identical test blasting with field construction such as rock slope blasting would be required.

Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement (대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계)

  • Kim, Hong-Bae;Lim, Jong-Min;Yang, Ho-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF

Vibration Reduction of Pipe Line in Air-conditioner for Railway Vehicle (철도차량용 냉방기 배관계의 진동저감 연구)

  • You, Won-Hee;Jung, Yong-Ho;Koo, Jeong-Seo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.925-931
    • /
    • 2012
  • The air-conditioner for railway vehicle should have vibration durability in order to operate normally in vehicle running situation. KS R 9144(vibration test methods for railway vehicle parts) is used to verify the vibration durability. The specifications of compressor, condenser and evaporator for air-conditioner in railway vehicle are standardized, but the shape and structure of pipe lines are not specified. Because the air-conditioner handler produces the pipe line arbitrarily, sometimes the pipe line is broken during the vibration durability test. In this research the cause identification and solution of pipe line breaking problem in during the vibration durability test were studied for air-conditioner of railway vehicle(diesel multiple unit). It was found that the natural frequency of pipe line is related to the pipe line breaking by experiment. A new pipe line shape was introduced by using FEA in order to avoid the resonance. The prototype new pipe line was applied to air-conditioner and the natural frequency was measured by experiment in order to verify the resonance avoidance. The vibration reduction of air-conditioner with new pipe line was reviewed by comparing to the air-conditioner with original one.

LAUNCH ENVIRONMENT TEST OF KOMPSAT-1 SATELLITE

  • Lee, Sang-Seol;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1234-1239
    • /
    • 2000
  • KOMPSAT-1(Korea Multi-Purpose Satellite), which opened the space era in Korean peninsula, was developed from 1994 and launched successfully in December of 1999 at VAFB, USA. This paper presents a launch environment test of KOMPSAT and a short description of environment test facilities at Korea Aerospace Research Institute as well. The launch environment tests of KOMPSAT-1 satellite, such as vibration, acoustic, pyro-shock and mass properties measurement test, were performed during its system integration and test period. The participating engineers concluded that KOMPSAT-1 satellite would withstand environment during its launch period.

  • PDF

Vibration Performance test and static load test of body flat freight car (평판화차의 차체 정하중시험 및 진동성능시험)

  • Hong Jai-Sung;Ham Young-Sam;Kim Gil-Dong;Han Suk-Youn;Cha Ji-Bum
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.700-705
    • /
    • 2003
  • The object of this study is to ensure the stability of flat freight cars using vibration performance test and static load test of body structures. We examined the flat car though static load test and dynamic characteristics analysis related traveling stability and vibration performance. In the results of static load test of body structures for flat car, all structures satisfied allowable stress of materials. The vibration performance test was satisfied with allowable standards. Although flat car exceed speed a little at some speed interval, it was estimated that the cause was not cars but rail.

  • PDF

A Study on Field Application of TEEE Material Rail Pad (TEEE 소재 레일패드의 현장 적용성에 관한 연구)

  • Kwon Sung-Tae;Hur Hyun-Moo;Kim Jung-Nam
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.516-521
    • /
    • 2004
  • TEEE(Thermoplastic ether-ester elastomer) is expected to reduce the noise and vibration from railway because its unique properties such as porosity. in this study, after building TEEE rail pad at established rail, we conducted practical test and vibration test to inquire the field application and endurance of TEEE material. The test results showed that TEEE material was lower vibration than EVA material, therefore, TEEE material was effective from a vibration reduction point of view.

  • PDF

A Study on the Structural Dynamic Modification of Sub-structure of Clean Room Considering Vibration Criteria (반도체 초정밀장비의 진동허용규제치를 고려한 지지구조의 동특성 개선에 관한 연구)

  • 손성완;이홍기;백재호
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.2
    • /
    • pp.25-30
    • /
    • 2003
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. This high technology equipments require very strict environmental vibration criteria in proportion to the accuracy of the manufacturing. In this paper, the dynamic analysis and modal test were performed to evaluate the dynamic properties of the constructing clean room structure. Based on these results, a structural dynamic modification(SDM) were required to satisfiy the vibration allowable limit for pression machine. Therefore, in order to improve the dynamic stiffness of clean room structure, the VSD system which can control the force applied on structure, were adopted and its utility were proved from dynamic test results of the improved structure after a modification work.

  • PDF