• 제목/요약/키워드: Vibration sensation

검색결과 51건 처리시간 0.027초

모바일 기기용 햅틱스를 위한 센서 및 구동기

  • 김상연
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2009년도 학술대회
    • /
    • pp.1683-1687
    • /
    • 2009
  • 본 논문에서는 모바일기기에 적용가능한 햅틱 액츄에이터들을 제시한다. 모바일 디바이스에서 햅틱감각을 전달하기 위하여 동작주파수, 자극의 세기 뿐 아니라 크기나 전력소모까지도 고려해야 한다. 그러므로 현재까지 많은 모바일 기기에서는 햅틱감각을 생성하기 위하여 크기가 작고 쉽게 장착가능한 진동모터를 많이 사용하고 있다. 본 논문에서는 진동 모터와 다양한 햅틱 감각을 생성할 수 있는 햅틱 액츄에이터들에 대하여 소개한다.

  • PDF

에어컨 소음의 Sound Quality 평가 (Evaluation of Sound Quality of Air-conditioning Noise)

  • 전진용;유진;김수연
    • 한국소음진동공학회논문집
    • /
    • 제16권5호
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.

Vibration Tactile Foreign Language Learning: The Possibility of Embodied Instructional Media

  • JEONG, Yoon Cheol
    • Educational Technology International
    • /
    • 제14권1호
    • /
    • pp.41-53
    • /
    • 2013
  • On the basis of two premises and embodied cognition theory, the vibration tactile learning is proposed as an effective method for foreign language learning. The premises are: the real nature of language is sound and the source of sound is vibration. According to embodied cognition theory, cognition is inherently connected to bodily sensation rather than metaphysical and independent. As a result, the vibration tactile learning is: people are able to learn foreign language better by listening to sound and experiencing its vibration through touch rather than solely listening to sound. The effectiveness of vibration tactile learning is tested with two instructional media theories: media comparison and media attribute. For the comparison, an experiment is conducted with control and experimental groups. The attributes of vibration tactile media are investigated in points of relationships with the learning process. The experiment results indicate a small effect on the increased mean score. Three kinds of relationships are found between the media attribute and learning process: enforced stimulus, facilitated pronunciation, and assimilation of resonance to sound patterns through touch. Finally, this paper proposes a new theoretical development for instructional media research: an embodied cognition based media research and development.

Sensory assessment of meshed skin grafts over free gracilis muscle flaps without nerve coaptation for lower extremity reconstruction

  • Tremp, Mathias;Waldkircher, Natascha J.;Wang, Wenjin;Oranges, Carlo M.;di Summa, Pietro G.;Zhang, Yixin;Wang, Wei;Schaefer, Dirk J.;Kalbermatten, Daniel F.
    • Archives of Plastic Surgery
    • /
    • 제48권2호
    • /
    • pp.224-230
    • /
    • 2021
  • Background Little is known about the sensate recovery of skin grafts over free non-neurotized muscle flaps. The aim of this study was to evaluate the sensitivity of free gracilis muscle flaps and meshed skin grafts without nerve coaptation. Methods Thirteen consecutive patients with a median age of 55 years (range, 21-70 years) who underwent lower extremity reconstruction between September 2014 and October 2016 were included. Complications, flap contour, skin perception, and sensate recovery were assessed. Results All flaps survived completely. In one patient, wound dehiscence and infection occurred 1 month after surgery. After a median follow-up of 14 months (range, 10-51 months), a satisfactory contour and skin perception were achieved. The Semmes-Weinstein (SW) monofilament test (154.8±22 g) and static two-point discrimination (2-PD) (12.6±0.7 mm) showed intermediate recovery compared to the surrounding site (41% and 76%, respectively). There was an intermediate correlation between flap size and sensate recovery (2-PD: r=0.27, P=0.36; SW test: r=0.45, P=0.12). Vibration sensation recovered to 60%, whereas thermal sensation remained poor (19% at 5℃ and 25% at 25℃). Conclusions Finer sensation could be partially restored. However, thermal sensation remained poor.

안마 및 발열기능의 스마트 조끼 개발과 성능 및 만족도 평가 (Development and Evaluation of Wearable Device with Heat and Massage Function)

  • 노의경;윤미경
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.676-685
    • /
    • 2020
  • This study developed smart vests with heat and massage functions that changed patterns, designs, materials, etc., and evaluated their functions and satisfaction. A knitted fabric with good elasticity and a heating lining were used, and in consideration of this, the final vest pattern fitted to the upper body was completed. A heat pad was attached to the back, and 6 vibration motors were attached to the trapezius muscle. The controller was placed on the left chest for easy operation, and the battery was stored in an inner pocket under the controller. The heating effect of the smart vest, the location of the devices, and the ease of operation were excellent. When the massage function was operated, the thermal comfort was increased compared to when the massage function was not operated, and the high thermal comfort was perceived by the operation of heat and heat+massage function. Due to the battery, the weight, irritating contact of devices and wearing sensation decreased, but there was no reduction in wearing sensation due to heat and vibration devices. The greater the satisfaction with the massage function, thermal comfort, fit, appearance and weight, the greater the product satisfaction.

자동차 실내 소음의 음질 연구 (A Study on the Sound Quality of Passenger Cars)

  • 김정우;최종대;허정기;변언섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.94-101
    • /
    • 1998
  • This paper presents the psychoacoustic analyses on the vehicle interior, noise generated when accelerating. Following the objective quantification for vehicle noises of different classes, the subjective decision process by the jury test is adopted to interrelate these results based on two different approaches. In particular, the paired comparison method is employed in assessing the sound quality in terms of the quietness, the powerfulness, and the pleasantness of the human auditory sensation. Special attention is paid to the physical interpretation of psychoacoutic parameters and their interrelation to the subjective assessment scores. In order to ensure the integrity of statistics of the survey, various tests are performed. The results show that the consistency of the "quiet" sensation is far higher than that of the "powerful" and the "pleasant" sensations. Also, it is found that the most significant parameter determining these feelings turns out to be the inherent loudness of the noise instead of the conventional indicators such as the weighted sound pressure level. It may be concluded that the psychoacoustic analysis offers more realistic evaluation for vehicle noise and assists the improvement of NVH more efficiently.ement of NVH more efficiently.

  • PDF

심상 기법을 이용한 단축발 운동이 만성 발목 불안정성에 미치는 효과 (Effect of Short Foot Exercise Using an Imagery Technique on Chronic Ankle Instability)

  • 이동진;지성하
    • 대한통합의학회지
    • /
    • 제5권2호
    • /
    • pp.1-10
    • /
    • 2017
  • Purpose : This study was aimed at investgating the effect of short foot exercise(SFE) using an imagery technique on chronic ankle instability(CAI). Methods : Twenty subjects with chronic ankle instability were selected by using the Cumberland ankle instability tool. They were randomly assigned to one of two groups(10 in each group) : namely the short foot exercise group and imagery technique group. The short foot exercise group performed short foot exercise for 6 weeks(3 times a week, 15 min per session). The imagery technique group performed short foot exercise(3 times a week, 15 min per session) and the imagery technique(3 times a week, 5 min per session) for 6 weeks. We measured chronic ankle instability, balance and threshold of vibration sensation before and after exercise by using the Cumberland ankle instability tool, Biodex Balance System and VSA-II, respectively. Results : We found statistically significant differences in cumberland ankle instability tool, balance and threshold of vibration sensation between the groups(p<.05). Conclusion : We confirmed the effect of short foot exercise using an imagery technique. Thus, we thought these results could be used as basic data and reference for musculoskeletal therapy or intervention using an imagery technique.

Tactile Sensation Display with Electrotactile Interface

  • Yarimaga, Oktay;Lee, Jun-Hun;Lee, Beom-Chan;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.145-150
    • /
    • 2005
  • This paper presents an Electrotactile Display System (ETCS). One of the most important human sensory systems for human computer interaction is the sense of touch, which can be displayed to human through tactile output devices. To realize the sense of touch, electrotactile display produces controlled, localized touch sensation on the skin by passing small electric current. In electrotactile stimulation, the mechanoreceptors in the skin may be stimulated individually in order to display the sense of vibration, touch, itch, tingle, pressure etc. on the finger, palm, arm or any suitable location of the body by using appropriate electrodes and waveforms. We developed an ETCS and investigated effectiveness of the proposed system in terms of the perception of roughness of a surface by stimulating the palmar side of hand with different waveforms and the perception of direction and location information through forearm. Positive and negative pulse trains were tested with different current intensities and electrode switching times on the forearm or finger of the user with an electrode-embedded armband in order to investigate how subjects recognize displayed patterns and directions of stimulation.

  • PDF

승용차량의 정차진동 주파수에 대한 불편함의 등감각곡선 (Equivalent Discomfort Curve on Idle Vibration Frequency of Passenger Vehicle)

  • 전경진;이재영;안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제22권6호
    • /
    • pp.535-541
    • /
    • 2012
  • The three-down one-up method which is commonly used in the field of psychophysics is employed in this study that is to reveal how much magnitude of vibration makes discomfort in passenger vehicle on idle condition. Thirteen taxi drivers were invited for subject of the experiment where they evaluated the controlled vibrations on rigid seat in terms of idle vibration on passenger vehicle at frequency range from 15 Hz to 40 Hz. As the result, vibration of 100~105 dB is marginal range to make discomfort on passenger seat. Frequency dependency of the discomfort was found at the frequency range, which is the higher frequency the lower discomfort with the same magnitude of vibration. The frequency dependency found here was compared with ISO 2631-1 that is more sensitive at the frequency range.

A Conceptual Design of an Integrated Tactile Display Device

  • Son, Seung-Woo;Kyung, Ki-Uk;Yang, Gi-Hun;Kwon, Dong-Soo;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2753-2758
    • /
    • 2003
  • Tactile sensation is essential for many manipulation and exploration tasks not only in a real environment but also in a virtual environment. In this paper, we discuss a conceptual design of an integrated tactile display system. The system comprises two parts: a 2 DOF force feedback device for kinesthetic display and a tactile feedback device for displaying the normal stimulation to skin and the skin slip/stretch. Psychophysical experiments measure the effects of fingerpad selection, the direction of finger movements and the texture width on tactile sensitivity. We also investigate characteristics of lateral finger movement while subjects perceive different textures. From the experimental results, the principal parameters for designing a tactile display are suggested. A tactile display device is implemented using eight piezoelectric bimorphs and a linear actuator, and is attached to a 2 DOF translational force feedback device to simultaneously simulate texture and stiffness of the object.

  • PDF