• 제목/요약/키워드: Vibration process

검색결과 1,801건 처리시간 0.033초

탄성지지된 밸브 배관계의 강제진동 특성 (Forced Vibration Analysis of Elastically Restrained Valve-pipe System)

  • 손인수;윤한기;민병현;허관도
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.90-96
    • /
    • 2012
  • The forced vibration response characteristics of a elastically restrained pipe conveying fluid with attached mass are investigated in this paper. Based on the Euler-Bernoulli beam theory, the equation of motion is derived by using Hamilton's principle. The effects of attached mass and spring constant on the forced vibration characteristics of pipe at conveying fluid are studied. The forced deflection response of pipe with attached mass due to the variation of fluid velocity is also presented. The deflection response is the mid-span deflection of the pipe. The dimensionless forcing frequency is the range from 0 to 16 which is the first natural frequency of the pipe.

발전소 순환수계통 수직펌프의 진동저감에 관한 연구 (Vibration Reduction of Vertical Pumps Used in the Power Plant Circulating Water System)

  • 박혁;유호선
    • 플랜트 저널
    • /
    • 제9권1호
    • /
    • pp.43-49
    • /
    • 2013
  • 본 연구에서는 국내 P복합발전소에서 실제 운전 중인 순환수계통 수직펌프를 대상으로 고유진동수를 측정하고, 유체와 구조가 연성된 경우의 진동이론으로부터 고진동의 원인을 파악하였다. 현장 상황에 가장 적합하며 경제적인 공진방지 대책을 선정하여 수치해석을 통해 실효성을 미리 확인한 후 실제 시스템에 적용하는 실증시험을 실시하였다.

  • PDF

스마트폰 거치대가 설치된 자전거 핸들의 구조 해석 (Structural Analysis of Bike Handle Installed with Smart Phone Depository)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.1-8
    • /
    • 2012
  • This study investigates stress and deformation due to static and dynamic vibration analysis about various types of bike handles installed with smart phone depositories. When force is applied on the side of handle at the models of type 1, 2, 3 and 4, the maximum equivalent stress is highest at type 2. The stress or deformation becomes lowest among these 4 model types. At vibration analysis, type 1 becomes safest within the range of 500Hz and type 3 becomes stable within the range of 100Hz. The result of this study can be applied with the design of bike handle installed with smart phone depository. The damage or deformation due to vibration can be prevented when the bike falls down. This result can be widely utilized to investigate and predict the durability.

에어 서스펜션 시트의 구조 및 진동해석에 관한 연구 (A Study on Structure and Vibration Analysis of an Air Suspension Seat)

  • 하정수;이건명
    • 한국기계가공학회지
    • /
    • 제16권6호
    • /
    • pp.47-54
    • /
    • 2017
  • This study analyzed air suspension seat frame structure and vibration for 50 - 180 kg mass driver to obtain optimum seat design parameter values for the equivalent spring constant and damping coefficient. Various air suspension seat frames were designed following WTS-003 and KS B 6839 standards, and then evaluated using finite elements analysis. Resonance and vibration tests were performed according to the 78/764/EEC standard.

광대역 정규 프로세스에 대한 주파수 영역 기반 피로해석법의 적용성에 관한 연구 I : 레일리 PDF (Study on Applicability of Frequency Domain-Based Fatigue Analysis for Wide Band Gaussian Process I : Rayleigh PDF)

  • 정준모;김경수;남지명;구정본;김민수;심용래;엄항섭
    • 대한조선학회논문집
    • /
    • 제49권4호
    • /
    • pp.350-358
    • /
    • 2012
  • This paper deals with accuracy of accumulated fatigue damage estimation using stochastic fatigue analysis method based on Rayleigh PDF. From full scale measurement data on an 8100TEU container vessel, zero-order spectral moments for wave- and vibration-induced energy spectral densities are determined on the probability level of 99%. 80 simulation cases in total are prepared according to the variation of ratio of zero-order spectral moments and center frequency of vibration ESD. By using inverse Fourier transformation and rainflow cycle counting for the combined ESD of wave and vibration, exact fatigue damages are derived. Fatigue damages in frequency domain based on Rayleigh PDF show large conservativeness compared to exact fatigue damages in times domain. The main cause of the excessive conservativeness is analyzed by two aspects: ratio of zero crossing and peak frequencies and ratio of initial zero order spectral moments and zero order spectral moments from rainflow stress range distributions. Finally, a guideline of applicability of Rayleigh PDF is proposed for wide band processes.

6 시그마 프로세스를 이용한 소형 직류 모터의 소음 절감 (Noise Reduction of a Small D/C Motor Using 6 Sigma Process)

  • 차원준;최연선
    • 한국소음진동공학회논문집
    • /
    • 제13권7호
    • /
    • pp.532-538
    • /
    • 2003
  • This paper studies on the noise reduction for a small automobile DC Motor (a window motor) using the 6 sigma process. The application of 6 sigma process suggested reliable and valuable statistical data for the quality of the DC motor at the production line. In the measurement step in 6 sigma process. the FMEA(failure mode effect analysis) were used for the detection of noise sources. The application of 6 sigma Process gave not only the improving method for the quality of the DC motor but also the confidence of improvement Itself since it was done on the basis of the test results for a number of DC motors at the production line. Consequently the 6 sigma process was proved very effective for the noise reduction at the production line.

판넬기여도와 설계민감도를 이용한 구조기인소음 설계프로세스 (A Design Process for Structural Borne Noise using Panel Contribution and Design Sensitivity)

  • 김효식;김헌희;조효진;윤성호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.806-811
    • /
    • 2007
  • In this study, we propose a more systematic design process for the structure-borne noise. The proposed way consists of 4 steps: Problem definition, Cause analysis, Development of counter-measure and Validation. Especially, we improved the second step: Cause analysis. According to the PCA(Panel Contribution Analysis), a reduction in vibration of the panels of which panel contribution is positive and larger, results in a reduction in structure-borne noise. We have, however, met the case in which the concept of PCA is no valid in a few vehicle tests. In order to understand this phenomenon, we compared the major panels selected by PCA with the one chosen by DSA(Design Sensitivity Analysis). After investigating the difference between the two results, a more improved process is suggested. The proposed one for the second step in the design process consists of not only the previous way: PCA with deformation analysis results but also DSA. It is finally validated that the proposed design process decreases the sound pressure of the concerned noise transfer function more than 3.5 dB.

  • PDF

A Study on the Assignment of the Vibration Classes to the Power Transformers in Operation (154[kV])

  • Kim, Young-Dal
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.52-60
    • /
    • 2009
  • High reliability is essential for power transformers, and their fault causes are reportedly more related to mechanical causes than electrical ones. The transformer soundness judgment currently depends only on the electrical insulation characteristic and the chemical test of the insulation oil, so that there are few fundamental measures against the frequent mechanical damages and failures in transformers. The mechanical soundness judgment techniques are conducted through processes that include structural analysis and vibration resistance treatment during the manufacturing process of each manufacturer, but the vibration is not tested during the design, manufacturing, and operating processes since there are no detailed technical standards and procedures on the vibration problem, which are important in terms of maintenance. Therefore, in this study, vibration phenomena were measured from the 32 power transformers in operation in the substations under the Daejeon Power Transmission District Office of the Korean Electric Power Corporation (KEPCO). The vibration was measured at 24 sections ($6{\times}4$) on one side, and only the maximum values were selected from the measured vibration values. This was because the maximum vibration values more significantly affect the soundness of the transformer than the average vibration values. The vibration classes were given considering the maximum vibration based on ISO 10016-1 (2001).