• 제목/요약/키워드: Vibration perception

검색결과 127건 처리시간 0.027초

노인의 환경인식과 주관적 건강과의 관련성 (Association between Environmental Perception and Subjective Health Status of Older Adults)

  • 이성은
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.391-396
    • /
    • 2018
  • Objectives: The purpose of this study is to examine the level of community environmental perception of older adults and to identify the association between environmental perception and subjective health status among older persons. Methods: Analyses are based on data from Statistics Korea 2016 Social Survey. This study analyzed a total of 8,193 older adults aged 65 and over, and examined the association between environmental perception on air, water, soil, noise and vibration, and subjective health status using multiple regression analysis. Results: Study findings shown that environmental perception on water and soil had significant association with subjective health status of older adults. Specifically, older adults reported worse health status when they had more negative perceptions of water and soil environments in their communities. Conclusions: Results of this study suggested that efforts to enhance safety of drinking water and soil environments, and continuous research to identify relationship between environment and elderly health shoud be needed.

환경지반진동의 예측사례 : 터널통과시 미치는 영향 (A Case Study on Environmental Vibration Prediction : Ground Vibration Effect near from a Tunnel)

  • 김정태
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.45-50
    • /
    • 2007
  • When the walls and floor of a tunnel are excited by a train, a ground vibration energy is transmitted to the surface and to footing of a nearby buildings. Excessive vibration affected to a building structure causes undesirable effect to the structural safety and the perception on residents in building. In this paper, a simple approach is introduced to predict how much vibration, in terms of level and spectra, is transmitted through the ground from the tunnel vibration excitation. A high rise building on a tunnel is selected as an application example of this case study.

Comparative evaluation of efficacy of external vibrating device and counterstimulation on child's dental anxiety and pain perception during local anesthetic administration: a clinical trial

  • Sahithi, Varada;Saikiran, Kanamarlapudi Venkata;Nunna, Mahesh;Elicherla, Sainath Reddy;Challa, Ramasubba Reddy;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권4호
    • /
    • pp.345-355
    • /
    • 2021
  • Background: This study aimed to evaluate the efficacy of external vibrating devices and counterstimulation on a child's dental anxiety, apprehension, and pain perception during local anesthetic administration. Methods: This was a prospective, randomized, parallel-arm, single-blinded interventional, clinical trial. One hundred children aged 4-11 years, requiring pulp therapy or extraction under local anesthesia (LA), were recruited and allocated equally into two groups (1:1) based on the interventions used: Group BD (n = 50) received vibration using a Buzzy® device {MMJ Labs, Atlanta, GE, USA} as a behavior guidance technique; Group CS (n = 50) received counterstimulation for the same technique. Anxiety levels [Venham's Clinical Anxiety Rating Scale (VCARS), Venham Picture Test (VPT), Pulse oximeter {Gibson, Fingertip Pulse Oximeter}, Beijing, China)] were assessed before, during, and after LA administration, while pain perception [Wong-Baker Faces Pain Rating Scale (WBFPS), Visual Analogue Scale (VAS)] was evaluated immediately after injection. Statistical analysis was performed using the Student's t-test to assess the mean difference between the two groups and the repeated measures ANOVA for testing the mean difference in the pulse rates. Statistical significance was set at P < 0.05. Results: Significant differences in mean pulse rate values were observed in both groups. In contrast, the children in the BD group had higher diminution (P < 0.05), whereas the mean VCARS and VPT scores were conspicuous (P < 0.05). Based on the mean WBFPS and VAS scores, delayed pain perception after LA injection was more prominent in the BD group than in the CS group. Conclusion: External vibration using a Buzzy® device is comparatively better than counterstimulation in alleviating needle-associated anxiety in children requiring extraction and pulpectomy.

Blink reflex changes and sensory perception in infraorbital nerve-innervated areas following zygomaticomaxillary complex fractures

  • Park, Young Sook;Choi, Jaehoon;Park, Sang Woo
    • Archives of Plastic Surgery
    • /
    • 제47권6호
    • /
    • pp.559-566
    • /
    • 2020
  • Background Infraorbital nerve dysfunction is commonly reported after zygomaticomaxillary complex fractures. We evaluated sensory changes in four designated areas (eyelid, nose, zygoma, and lip) innervated by the infraorbital nerve. This evaluation was conducted using the static two-point discrimination test and the vibration threshold test. We assessed the diagnostic significance of the blink reflex in patients with infraorbital nerve dysfunction. Methods This study included 18 patients, all of whom complained of some degree of infraorbital nerve dysfunction preoperatively. A visual analog scale, the infraorbital blink reflex, static two-point discrimination, and the vibration threshold were assessed preoperatively, at 1 month postoperatively (T1), and at a final follow-up that took place at least 4 months postoperatively (T4). The results were analyzed using a multilevel generalized linear mixed model. Results Scores on the visual analog scale significantly improved at T1 and T4. The infraorbital blink reflex significantly improved at T4. Visual analog scale scores improved more rapidly than the infraorbital blink reflex. Two-point discrimination significantly improved in all areas at T4, and the vibration perception threshold significantly improved in the eyelid at T4. Conclusions Recovery of the infraorbital blink reflex reflected the recovery of infraorbital nerve dysfunction. We also determined that the lip tended to recover later than the other areas innervated by the infraorbital nerve.

질량법칙을 이용한 연료펌프 특정음 저감 방법 (Particular Noise Reduction Method used to Mass Law)

  • 강태식;심재기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.759-763
    • /
    • 2004
  • High frequency noise of fuel pump has does claimed by user. But high frequency of fuel pump can't heat in the car. But this noise Is an offensive noise outside car. In this study is noise reduction used to mass law. Especially high frequency (for example BPF(blade pass frequency)) is influenced of this law. In detail used to transmission and add to mass according to mass law, reduced particular noise. As a result high frequency is down until can't perception.

  • PDF

Vibration Tactile Foreign Language Learning: The Possibility of Embodied Instructional Media

  • JEONG, Yoon Cheol
    • Educational Technology International
    • /
    • 제14권1호
    • /
    • pp.41-53
    • /
    • 2013
  • On the basis of two premises and embodied cognition theory, the vibration tactile learning is proposed as an effective method for foreign language learning. The premises are: the real nature of language is sound and the source of sound is vibration. According to embodied cognition theory, cognition is inherently connected to bodily sensation rather than metaphysical and independent. As a result, the vibration tactile learning is: people are able to learn foreign language better by listening to sound and experiencing its vibration through touch rather than solely listening to sound. The effectiveness of vibration tactile learning is tested with two instructional media theories: media comparison and media attribute. For the comparison, an experiment is conducted with control and experimental groups. The attributes of vibration tactile media are investigated in points of relationships with the learning process. The experiment results indicate a small effect on the increased mean score. Three kinds of relationships are found between the media attribute and learning process: enforced stimulus, facilitated pronunciation, and assimilation of resonance to sound patterns through touch. Finally, this paper proposes a new theoretical development for instructional media research: an embodied cognition based media research and development.

Factors Affecting Discrimination of Surface Property Using an Integrated Tactile Display;Roughness and Vibration

  • Jeong, Young-Ju;Yang, Gi-Hun;Kyung, Ki-Uk;Kwon, Dong-Soo;Kang, Sung-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.596-601
    • /
    • 2004
  • In this paper, we describe a study on the influence of the frequency variation of normal vibration using an integrated tactile display. It is necessary to consider this study because we want to find a method of displaying finer texture and know that the perception of fine textures is heavily influenced by temporal variation. Our tactile display system used in this experiment can simulate the micro shapes and roughness of surface textures by individual drives of a 6x8 pin array. Two experiments are performed. The first is a psychophysical experiment on the definition and range decision of roughness, and through the experiment, we clear up the meaning of roughness. The second is the main experiment about the frequency variation of normal vibration. We find the correlation between the vibration frequency and the texture and the condition for better display and perception of fine surfaces. The experimental results yielded two pieces of information. One is that lateral movement affects texture discrimination, and another is that normal vibration can make the perceived texture feel finer than real texture. That is, the vibrating stimulus is more effective for displaying a fine surface than static pressure, and it makes possible to display finer texture, exceeding the physical limit of the device.

  • PDF

동일한 선형 음압 레벨의 도로교통소음의 성가심 유발 인자에 관한 연구 (Auditory Perception Experiment on Attribute of Road Traffic Noise Causing Annoyance with Identical Linear Sound Pressure Level)

  • 안장호;장서일;고준희;전형준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.641-648
    • /
    • 2006
  • This study investigates which sound quality indices except SPL raise annoyance response. For investigation, auditory perception experiments for road traffic noise with identical linear SPL were performed by Paired Comparison Method. The numerical results of a Paired Comparison experiment express relative preference about annoyance. So that these relative preference scores are to be correlated to sound quality indices, which are absolute, a transformation is required to go from the relative domain to an absolute and linear scale of preference. The results of the transformation will be the 'merit values,' which quantifies the annoyance(in this case) of the road traffic noise on a linear scale. Using multiple regression, a formula is established that can calculate predicted merit values. Furthermore, This investigation offers a method selecting sound samples that represent various sound quality indices values to use experiment.

  • PDF

Sensible Media Simulation in an Automobile Application and Human Responses to Sensory Effects

  • Kim, Sang-Kyun;Joo, Yong-Soo;Lee, YoungMi
    • ETRI Journal
    • /
    • 제35권6호
    • /
    • pp.1001-1010
    • /
    • 2013
  • A sensible media simulation system for automobiles is introduced to open up new possibilities for an in-car entertainment system. In this paper, the system architecture is presented, which includes a virtuality-to-reality adaptation scheme. Standard data schemes for context and control information from the International Standard MPEG-V (ISO/IEC 23005) are introduced to explain the details of data formats, which are interchangeable in the system. A sensible media simulator and the implementation of a sensory device are presented to prove the effectiveness of the proposed system. Finally, a correlation between learning styles and sensory effects (that is, wind and vibration effects) is statistically analyzed using the proposed system. The experiment results show that the level of satisfaction with the sensory effects is unaffected overall by the learning styles of the test subjects. Stimulations by vibration effects, however, generate more satisfaction in people with a high tactile perception level or a low visual perception level.