• Title/Summary/Keyword: Vibration perception

Search Result 126, Processing Time 0.018 seconds

Analysis of Friction Mechanisms Associated with Write Feeling (필기 감성에 관련한 마찰메커니즘 분석)

  • Park, JinHwak;Kim, MinSeob;Lee, YoungZe
    • Tribology and Lubricants
    • /
    • v.32 no.6
    • /
    • pp.207-211
    • /
    • 2016
  • To interpret the perception that originates from tactile sensibility during people touch and recognize the object surfaces, this study focuses on the development of a friction model that can describe the interaction of a stylus pen sliding over the counter surfaces. In addition, the study includes several other experimental factors such as the pressure, temperature, and topology of surface, which can have an effect on the emotional user experience concerning various surfaces; this research aims to suggest a method to quantitatively evaluate the relation between these experimental parameters and emotional user experience. Accordingly, the objective of research comprises the friction characteristic technology for measurement of fine tribological behavior and a standard to quantify the emotional feedback. Existing panels or input devices that provide interaction feedback about user actions simply operate with a single frequency vibration or sound response. On the contrary, this research investigates various interaction characteristics including friction force, frequency, and surface topology synthetically. Using the developed model, which can explain the relation between the friction parameters and emotional user experience, developers can design their product in order to provide the user with expected emotional sensibility. Consequently, it can contribute to reduce the development cost about sensitivity model.

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Quantitative Sensory Test: Normal Range in Korean Adults and Application to Diabetic Polyneuropathy (정량적 감각 검사: 한국인에서의 연령별 정상 범위 및 당뇨병성 다발신경병증에서의 유용성 평가)

  • Kim, Su-Hyun;Kim, Sung-Min;Ahn, Suk-Won;Hong, Yoon-Ho;Park, Kyung-Seok;Sung, Jung-Joon;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • Background: Although quantitative sensory test (QST) is being used with increasing frequency for measuring sensory thresholds in clinical practice and epidemiologic studies, there has been no age-matched normative data in Korean adults. The objective of this study is to evaluate the value of QST in diabetic polyneuropathy with normal range in Korean adults. Methods: The Computer Aided Sensory Examination IV 4,2 (WR Medical Electronics Co., Stillwater, Minnesota, U.S.A.), with 4,2,1 stepping algorithm was used to determine vibration and cold perception threshold in 70 normal controls and 19 patients with diabetic polyneuropathy aged from 21 to 79 years. The data were used to define age-matched upper and lower normal limits and normal range of side to side difference. We also evaluated the duration of diabetes, serum HbA1C level, and findings of nerve conduction study (NCS) and QST in patients with diabetic polyneuropathy. Results: In normal adults, sensory thresholds slightly increased with age, and a slight side-to-side difference was observed. The diagnostic sensitivity of QST was not higher than NCS in patients with diabetic polyneuropathy (36.8% vs. 42.1%, p=0.716), especially among elderly patients. Conclusions: QST might be used as a complementary test for NCS in the diagnosis of diabetic polyneuropathy. Although the QST is a simple method for the evaluation of peripheral nerve function, there are some limitations. Most of all, because the QST measuring is dependent on the subjective response of patients, the degree of concentration and cooperation of the patients can significantly affect the result. And thus, attention should be paid during the interpretation of QST results in patients with peripheral neuropathy.

Development of u-Health Care System for Prompt Perception of Emergencies (응급상황의 신속한 감지를 위한 u-Health 시스템 개발에 관한 연구)

  • Jang, Dong-Wook;Sun, Bok-Keun;Sohn, Surg-Won;Han, Kwang-Rok
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.401-406
    • /
    • 2007
  • This study discusses the development of a u-Health care system that can detect quickly and cope actively with emergent situations of chronic disease patients who lead everyday life. If a patient's emergent situation is detected by personal health care host(PHCH), which is composed of acceleration and vibration sensors, GPS, and CDMA communication module, a text message on the patient's current location is transmitted to the hospital and the guardian's mobile terminal so that they can cope with the situation immediately. Especially, the system analyzes data from sensors by using neural network and determines emergent situations such as syncope and convulsion promptly. The exact location of patients can also be found in the electronic map by using GPS information. The experiments show that this system is very effective to find emergencies promptly for chronic disease patients who cannot take care of themselves and it is expected to save many lives.

An Enhanced Fuzzy Single Layer Perceptron With Linear Activation Function (선형 활성화 함수를 이용한 개선된 퍼지 단층 퍼셉트론)

  • Park, Choong-Shik;Cho, Jae-Hyun;Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1387-1393
    • /
    • 2007
  • Even if the linearly separable patterns can be classified by the conventional single layer perceptron, the non-linear problems such as XOR can not be classified by it. A fuzzy single layer perceptron can solve the conventional XOR problems by applying fuzzy membership functions. However, in the fuzzy single layer perception, there are a couple disadvantages which are a decision boundary is sometimes vibrating and a convergence may be extremely lowered according to the scopes of the initial values and learning rates. In this paper, for these reasons, we proposed an enhanced fuzzy single layer perceptron algorithm that can prevent from vibration the decision boundary by introducing a bias term and can also reduce the learn time by applying the modified delta rule which include the learning rates and the momentum concept and applying the new linear activation function. Consequently, the simulation results of the XOR and pattern classification problems presented that the proposed method provided the shorter learning time and better convergence than the conventional fuzzy single layer perceptron.

DentalVibe versus lignocaine hydrochloride 2% gel in pain reduction during inferior alveolar nerve block in children

  • Menni, Alekhya Chowdary;Radhakrishna, Ambati Naga;Prasad, M. Ghanashyam
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.6
    • /
    • pp.397-402
    • /
    • 2020
  • Background: Inferior alveolar nerve block (IANB) is the most common, painful, and anxiety-provoking procedure involving needle insertion for anesthetic solution deposition. DentalVibeⓇ (DV) delivers vibration at a sustained frequency as a counter-stimulation to the site of injection, thereby alleviating pain. The aim of this study was to evaluate and compare the effectiveness of DV and lignocaine hydrochloride 2% gel (Lox 2% jelly) in pain reduction during IANB in children. Methods: A split-mouth randomized clinical trial was designed with a sample of 60 children (age, 6 to 12 years) requiring bilateral IANB for various dental procedures; DV was used while administering IANB and Lox 2% jelly was used as the topical anesthetic before administering IANB at subsequent appointments. During both appointments, pain perception was measured using the sound, eye, motor (SEM) scale and Wong-Baker faces pain rating scale (WBFPRS); oxygen saturation (SpO2) and pulse rate were measured using a pulse oximeter before, during, and after the IANB procedure. The obtained values were tabulated and subjected to statistical analysis. Wilcoxon test was used for intergroup comparison, and Friedman test, for intragroup comparison of measured variables at different treatment phases. Results: The medians and interquartile ranges of the WBFPRS scores recorded during the IANB procedure for DV and Lox 2% jelly were 2 (2-4) and 2 (0-2), respectively (P < 0.05). The SEM scale scores, mean SpO2, and pulse rate did not show any significant differences during the IANB procedure between both treatments. Conclusion: Both DV and Lox 2% jelly were found to be effective in pain reduction during IANB in children.