• 제목/요약/키워드: Vibration mitigation

검색결과 180건 처리시간 0.026초

Fatigue laboratory tests toward the design of SMA portico-braces

  • Carreras, G.;Casciati, F.;Casciati, S.;Isalgue, A.;Marzi, A.;Torra, V.
    • Smart Structures and Systems
    • /
    • 제7권1호
    • /
    • pp.41-57
    • /
    • 2011
  • A deeper understanding of the effectiveness of adopting devices mounting shape memory alloy (SMA) elements in applications targeted to the mitigation of vibrations is pursued via an experimental approach. During a seismic event, less than 1000 loading-unloading cycles of the alloy are required to mitigate the earthquake effects. However, the aging effects during the time of inactivity prior to the oscillations (several decades characterized by the yearly summer-winter temperature wave) should be considered in order to avoid and/or minimize them. In this paper, the results obtained by carrying out, in different laboratories, fatigue tests on SMA specimens are compared and discussed. Furthermore, the effects of seismic events on a steel structure, with and without SMA dampers, are numerically simulated using ANSYS. Under an earthquake excitation, the SMA devices halve the oscillation amplitudes and show re-centering properties. To confirm this result, an experimental campaign is conducted by actually installing the proposed devices on a physical model of the structure and by evaluating their performance under different excitations induced by an actuator.

사용중 시간영역응답을 이용한 손상탐지이론의 검증 (Verification of Damage Detection Using In-Service Time Domain Response)

  • 최상현;김대혁;박남회
    • 한국방재학회 논문집
    • /
    • 제9권5호
    • /
    • pp.9-13
    • /
    • 2009
  • 현재까지 구조건전성 모니터링과 관련하여 제안된 대부분의 손상인식기법은 모달영역응답을 이용하고 있으나, 모달영역응답은 별도의 후처리가 필요하며 추출과정에서 오차를 포함하게 되므로 손상인식의 정확성을 저하시키는 요인이 되어왔다. 본 논문에서는 이동하중응답을 직접 이용하는 손상인식기법의 적용성을 실내 실험을 통하여 검증하였다. 실험은 강재로 만든 보에 이동하중을 재하시켜 수행하였으며, 보의 응답은 변위계를 이용하여 측정하였다. 이동하중은 쇠구슬과 활강장치를 이용하여 모사하였으며, 주기성과 비주기성 이동하중으로 구분하여 재하하였다. 계측된 응답을 이용한 손상인식 결과, 이동하중을 이용한 손상인식기법은 구조물의 손상을 성공적으로 탐지하는 것으로 나타났다.

Numerical study on Floor Response Spectrum of a Novel High-rise Timber-concrete Structure

  • Xiong, Haibei;Zheng, Yingda;Chen, Jiawei
    • 국제초고층학회논문집
    • /
    • 제9권3호
    • /
    • pp.273-282
    • /
    • 2020
  • An innovative high-rise timber-concrete hybrid structure was proposed in previous research, which is composed of the concrete frame-tube structure and the prefabricated timber modules as main structure and substructures, respectively. Considering that the timber substructures are built on the concrete floors at a different height, the floor response spectrum is more effective in estimating the seismic response of substructures. In this paper, the floor response spectra of the hybrid structure with different structural parameters were calculated using dynamic time-history analysis. Firstly, one simplified model that can well predict the seismic response of the hybrid structure was proposed and validated. Then the construction site, the mass ratio and the frequency ratio of the main-sub structure, and the damping ratio of the substructures were discussed. The results demonstrate that the peaks of the floor response spectra usually occur near the vibration periods of the whole structure, among which the first two peaks stand out; In most cases, the acceleration amplification effect on substructures tends to be more evident when the construction site is farther from the fault rupture; On the other hand, the acceleration response of substructures can be effectively reduced with an appropriate increase in the mass ratio of the main-sub structure and the damping ratio of the substructures; However, the frequency ratio of the main-sub structure has no discernible effect on the floor response spectra. This study investigates the characteristics of the floor response spectrum of the novel timber-concrete structure, which supports the future applications of such hybrid structure in high-rise buildings.

Peak Factors for Bridges Subjected to Asynchronous Multiple Earthquake Support Excitations

  • Yoon, Chong-Yul;Park, Joon-Seok
    • 한국방재학회 논문집
    • /
    • 제11권1호
    • /
    • pp.7-13
    • /
    • 2011
  • 지진에 대한 장대 교량의 정확한 반응 해석은 지진 방재에 있어서 중요한 역할을 한다. 본 논문은 비동기 다지지점 지진입력에 의한 교량의 반응을 진동수 영역방법과 시간 영역방법으로 해석하였으며 그 결과를 동기 입력 결과와 비교하였다. 시간영역방법에서는 선형모드 중첩 법으로 최대반응 값을 계산하였다. 진동수영역방법에서는 선형랜덤진동 이론을 사용하여 교량 성능에 영향을 미치는 모드와 다지지점 지진입력의 상호상관관계를 고려한 반응의 제곱평균근(RMS값)을 계산하였다. 교량 성능 반응 중, 변위 및 부재의 내력에 대한 시간 영역해석 결과와 진동수영역 해석 결과로부터 최대반응 값과 RMS값의 비로 정의된 최대반응 계수의 실용적인 값과 계산 방법을 요약하였다. 신뢰 있는 최대 반응계수가 있으면, 교량의 성능기반설계에서 구체적인 임의의 입력을 고려한 시간영역방법보다 결과의 일반성 및 수치적인 장점을 갖은 진동수영역방법이 더 효율적이다.

Numerical study on the mitigation of rain-wind induced vibrations of stay cables with dampers

  • Li, Shouying;Wu, Teng;Li, Shouke;Gu, Ming
    • Wind and Structures
    • /
    • 제23권6호
    • /
    • pp.615-639
    • /
    • 2016
  • Although the underlying mechanism of rain-wind induced vibrations (RWIVs) of stay cables has not been fully understood, some countermeasures have been successfully applied to mitigating this kind of vibration. Among these, installing dampers near the bridge deck was widely adopted, and several field observations have shown its effectiveness. In this study, the effectiveness of dampers to RWIVs of stay cables is numerically investigated comprehensively by means of finite difference method (FDM). Based on the free vibration analysis of a taut string, it is found that the 3-points triangle scheme, which can be easily implemented in FDM, can offer an excellent approximation of the concentrated damping coefficient (expressed as a Dirac delta function) at the location where the damper is installed. Then, free vibration analysis of a 3-D continuous stay cable attached with two dampers is carried out to study the relationship of modal damping ratio and damping coefficient of the dampers. The effects of orientation of the dampers and cable sag on the modal damping ratio are investigated in detail. Finally, the RWIV response of a 3-D continuous stay cable attached with two dampers is examined. The results indicate that 0.5% of damping ratio is sufficient to reduce the RWIV vibration of the Cable A20 on the No.2 Nanjing Bridge over Yangtze River.

Simultaneous out-of-plane and in-plane vibration mitigations of offshore monopile wind turbines by tuned mass dampers

  • Zuo, Haoran;Bi, Kaiming;Hao, Hong
    • Smart Structures and Systems
    • /
    • 제26권4호
    • /
    • pp.435-449
    • /
    • 2020
  • To effectively extract the vast wind resource, offshore wind turbines are designed with large rotor and slender tower, which makes them vulnerable to external vibration sources such as wind and wave loads. Substantial research efforts have been devoted to mitigate the unwanted vibrations of offshore wind turbines to ensure their serviceability and safety in the normal working condition. However, most previous studies investigated the vibration control of wind turbines in one direction only, i.e., either the out-of-plane or in-plane direction. In reality, wind turbines inevitably vibrate in both directions when they are subjected to the external excitations. The studies on both the in-plane and out-of-plane vibration control of wind turbines are, however, scarce. In the present study, the NREL 5 MW wind turbine is taken as an example, a detailed three-dimensional (3D) Finite Element (FE) model of the wind turbine is developed in ABAQUS. To simultaneously control the in-plane and out-of-plane vibrations induced by the combined wind and wave loads, another carefully designed (i.e., tuned) spring and dashpot are added to the perpendicular direction of each Tuned Mass Damper (TMD) system that is used to control the vibrations of the tower and blades in one particular direction. With this simple modification, a bi-directional TMD system is formed and the vibrations in both the out-of-plane and in-plane directions are simultaneously suppressed. To examine the control effectiveness, the responses of the wind turbine without control, with separate TMD system and the proposed bi-directional TMD system are calculated and compared. Numerical results show that the bi-directional TMD system can simultaneously control the out-of-plane and in-plane vibrations of the wind turbine without changing too much of the conventional design of the control system. The bi-directional control system therefore could be a cost-effective solution to mitigate the bi-directional vibrations of offshore wind turbines.

제진재 혼입 콘크리트의 동적물성에 관한 실험적 연구 (An Experimental Study on Dynamic Properties of Concrete with Vibration-Mitigation Materials)

  • 정영수;박용구
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.261-270
    • /
    • 1999
  • 본 실험적 연구에서는 동적신호분석기를 사용하여 고강도 콘크리트 재료의 1차 공명진동수, 동탄성계수, 동전단탄성계수, 감쇠비 및 동포아송비등의 재료의 동적물성값을 실험적으로 규명하였다. 선정된 배합비에 따라 제작된 고강도 콘크리트 시험체의 압축강도 실험후 lst Natural Frequency, 동탄성계수, 동전단탄성계수, 동포아송비와 같은 역학적 성질들을 공명주기법을 이용한 비파괴 실험을 실시하여 그 결과로부터 동탄성계수 및 동전단탄성계수, 재료적 감쇠비를 파악하기 위하여 공명진동실험을 수행하였다. 또한 구조적 감쇠비와 고유주파수 등을 규명하기 위하여 각 배합별로 $15{\times}10{\times}240cm$의 RC보시험체를 제작하여 자유진동시험를 실시하여 주파수 영역에서 Half-Power Bandwidth방법으로 측정하였다. 그리고 정적하중으로 RC보시험체에 균열을 발생시킨 후 하중단계별 고유진동수, 감쇠비등을 조사하여 손상정도에 따른 변화를 비교, 분석하였다. 실험결과 동적실험, 즉 공명진동실험으로 고강도 콘크리트와 제진재 혼입콘크리트의 재료적 동적물성을 측정하였고 강도증가에 따라 재료적 감쇠비 감소현상을 확인할 수 있었다. RC보시험체는 하중단계에 따라, 즉 손상정도에 따라 고유진동수는 감소하고 구조적 감소비는 증가하는 경향이 나타났다.

Cable with discrete negative stiffness device and viscous damper: passive realization and general characteristics

  • Chen, Lin;Sun, Limin;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.627-643
    • /
    • 2015
  • Negative stiffness, previously emulated by active or semi-active control for cable vibration mitigation, is realized passively using a self-contained highly compressed spring, the negative stiffness device (NSD).The NSD installed in parallel with a viscous damper (VD) in the vicinity of cable anchorage, enables increment of damper deformation during cable vibrations and hence increases the attainable cable damping. Considering the small cable displacement at the damper location, even with the weakening device, the force provided by the NSD-VD assembly is approximately linear. Complex frequency analysis has thus been conducted to evaluate the damping effect of the assembly on the cable; the displacement-dependent negative stiffness is further accounted by numerical analysis, validating the accuracy of the linear approximation for practical ranges of cable and NSD configurations. The NSD is confirmed to be a practical and cost-effective solution to improve the modal damping of a cable provided by an external damper, especially for super-long cables where the damper location is particularly limited. Moreover, mathematically, a linear negative stiffness and viscous damping assembly has proven capability to represent active or semi-active control for simplified cable vibration analysis as reported in the literature, while in these studies only the assembly located near cable anchorage has been addressed. It is of considerable interest to understand the general characteristics of a cable with the assembly relieving the location restriction, since it is quite practical to have an active controller installed at arbitrary location along the cable span such as by hanging an active tuned mass damper. In this paper the cable frequency variations and damping evolutions with respect to the arbitrary assembly location are then evaluated and compared to those of a taut cable with a viscous damper at arbitrary location, and novel frequency shifts are observed. The characterized complex frequencies presented in this paper can be used for preliminary damping effect evaluation of an adaptive passive or semi-active or active device for cable vibration control.

Damping of a taut cable with two attached high damping rubber dampers

  • Cu, Viet Hung;Han, Bing;Wang, Fang
    • Structural Engineering and Mechanics
    • /
    • 제55권6호
    • /
    • pp.1261-1278
    • /
    • 2015
  • Due to their low intrinsic damping, stay cables in cable-stayed bridges have often exhibited unanticipated and excessive vibrations which result in increasing maintenance frequency and disruption to normal operations of the entire bridges. Mitigation of undesired cable vibration can be achieved by attaching an external damping device near the anchorage. High Damping Rubber (HDR) dampers have many advantages such as compact size, better aesthetics, easy maintenance, temperature stability, and cost benefits; therefore, they have been widely used to increase cable damping. Although a single damper has been shown to reduce cable vibrations, it is not the most effective method due to geometric constraints. This paper proposes the use of two HDR dampers to improve effectiveness and robustness in suppressing cable vibration. Oscillation parameters of the cable-dampers system were investigated in detail by modeling the stay cable as a taut string and each HDR damper as complex-valued impedance and by using an analytical formulation of the complex eigenvalue problem. The problem of two HDR dampers arbitrarily located along a cable is solved and the solution is discussed. Asymptotic formulas to calculate the damping ratios of the cable with two HDR dampers installed near the anchorage(s) are proposed and compared with the exact solutions. Further, a design example is presented in order to justify the methodology. The results of this study show that when the two HDR dampers are installed close to each other on the same end of the cable, some interaction between the dampers leads to reduced damping ratio. When the dampers are on the opposite ends of the cable, they are effective in increasing damping ratio and can provide better vibration reduction to multiple modes.

Design formulas for vibration control of sagged cables using passive MR dampers

  • Duan, Yuanfeng;Ni, Yi-Qing;Zhang, Hongmei;Spencer, Billie F. Jr.;Ko, Jan-Ming;Dong, Shenghao
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.537-551
    • /
    • 2019
  • In this paper, a method for analyzing the damping performance of stay cables incorporating magnetorheological (MR) dampers in the passive control mode is developed taking into account the cable sag and inclination, the damper coefficient, stiffness and mass, and the stiffness of damper support. Both numerical and asymptotic solutions are obtained from complex modal analysis. With the asymptotic solution, analytical formulas that evaluate the equivalent damping ratio of the sagged cable-damper system in consideration of all the above parameters are derived. The main thrust of the present study is to develop an general design formula and a universal curve for the optimal design of MR dampers for adjustable passive control of sagged cables. Two sag-affecting coefficients are derived to reflect the effects of cable sag on the maximum attainable damping ratio and the optimal damper coefficient. For the cable configurations commonly used in cable-stayed bridges, the sag-affecting coefficients are directly expressed in terms of the sag-extensibility parameter to facilitate the control design. A case study on adjustable passive vibration control of the longest cable (536 m) on Stonecutters Bridge is carried out to demonstrate the influence of the sag for the damper design, and to figure out the necessity of adjustability of damper coefficients for achieving maximum damping ratio for different vibration modes.