• Title/Summary/Keyword: Vibration measurement

Search Result 2,177, Processing Time 0.025 seconds

A fast high-resolution vibration measurement method based on vision technology for structures

  • Son, Ki-Sung;Jeon, Hyeong-Seop;Chae, Gyung-Sun;Park, Jae-Seok;Kim, Se-Oh
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.294-303
    • /
    • 2021
  • Various types of sensors are used at industrial sites to measure vibration. With the increase in the diversity of vibration measurement methods, vibration monitoring methods using camera equipment have recently been introduced. However, owing to the physical limitations of the hardware, the measurement resolution is lower than that of conventional sensors, and real-time processing is difficult because of extensive image processing. As a result, most such methods in practice only monitor status trends. To address these disadvantages, a high-resolution vibration measurement method using image analysis of the edge region of the structure has been reported. While this method exhibits higher resolution than the existing vibration measurement technique using a camera, it requires significant amount of computation. In this study, a method is proposed for rapidly processing considerable amount of image data acquired from vision equipment, and measuring the vibration of structures with high resolution. The method is then verified through experiments. It was shown that the proposed method can fast measure vibrations of structures remotely.

Measurement of Vibration Signals of a Gun Barrel Type Structure using Mechanical Filter (기계적 필터를 이용한 포신형상 구조물의 진동신호 측정)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.440-443
    • /
    • 2010
  • This paper deals with the method of vibration measurement of a gun barrel structure using mechanical filter. When a bullet with high speed is moving within a gun barrel type structure with low bending vibration frequencies, it is difficult to measure the bending vibration signals of the structure. For example, noncontact type sensors such as displacement or velocity sensor are not appropriate for the measurement of vibrational signals because of the movement effect of the equipment frame through the moving structures or effect of the ground vibration. One of contact type sensors such as accelerometer is profitable for measurement of vibrational signals because of its wide measurement ranges. In the case of a gun barrel structure including high vibrational signals like shock waves, however, it is necessary to propose vibration measurement method filtering high frequencies. The purpose of the paper is to propose the proper vibrational measurement technique filtering high frequencies of a gun barrel type structure.

VIBRATION DISPLACEMENT MEASUREMENT TECHNOLOGY FOR CYLINDRICAL STRUCTURES USING CAMERA IMAGES

  • SON, KI-SUNG;JEON, HYEONG-SEOP;PARK, JIN-HO;PARK, JONG WON
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.488-499
    • /
    • 2015
  • Acceleration sensors are usually used to measure the vibration of a structure. Although this is the most accurate method, it cannot be used remotely because these are contact-type sensors. This makes measurement difficult in areas that cannot be easily approached by surveyors, such as structures located in high or dangerous areas. Therefore, a method that can measure the structural vibration without installing sensors is required for the vibration measurement of structures located in these areas. Many conventional studies have been carried out on non-contact-type vibration measurement methods using cameras. However, they have been applied to structures with relatively large vibration displacements such as buildings or bridges, and since most of them use targets, people still have to approach the structure to install the targets. Therefore, a new method is required to supplement the weaknesses of the conventional methods. In this paper, a method is proposed to measure vibration displacements remotely using a camera without having to approach the structure. Furthermore, an estimation method for the measurement resolution and measurement error is proposed for the vibration displacement of a cylindrical structure measured using the proposed measurement method. The proposed methods are described, along with experimental results that verify their accuracy.

Estimation of the Measurement Uncertainty in Measuring the Vibration Transmissibility of Anti-vibration Gloves (방진장갑 진동 전달률 측정에서의 측정불확도 추정)

  • Hong, Seok-In;Jang, Han-Ki;Choi, Seok-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.251-254
    • /
    • 2005
  • In this study vibration transmissibilities of the selected anti-vibration gloves were measured, and the measurement uncertainty was estimated. Since human factors such as palm size, gripping condition and dynamic properties of the hand-arm effect the measurement a lot, it is necessary to know ow much the uncertainty is. This study takes the measurement procedure suggested in ISO 10819. Three subjects Joined at each test and each anti-vibration glove was tested twice per a subject. Average and standard deviation of vibration transmissibility were calculated and uncertainty of them were estimated at 95% confidence level.

  • PDF

Vibration Measurements and Verification Based on Image Processing Using Optical Flow (옵티컬 플로우를 이용한 영상처리 기반 진동 계측 및 검증)

  • Jun-Byung Baek;Tae-Hee Lee;Soo-Yeon Lim;Bong-Yeol Choi;Doo-Hyun Choi
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.384-390
    • /
    • 2024
  • Conventional vibration-measurement methods used for vibration testing typically employ accelerometers, which offer the significant advantage of accurately measuring vibrations at specific positions. However, they can only measure one point at a time as simultaneously measurements of multiple points can be economically disadvantageous. This study aims to overcome these limitations by analyzing the vibration outputs of accelerometers attached to a product and those obtained through image processing. The analysis involved assessing the measurement uncertainties and verifying the low-frequency vibration testing according to KS standards. The results validated and confirmed the reliability of the proposed camera-based image-processing vibration-measurement method, which exhibited a notable vibration-detection performance and measurement errors within 5% compared to accelerometers for low-frequency vibrations. This method has the potential for application across various vibration-response and durability evaluations. Future research should focus on expanding it to high-frequency vibration testing using high-speed cameras and further enhancing image-based vibration-analysis techniques.

Measurement and Frequency Weighting Functions for Human Vibration

  • Kee, Dohyung;Park, Hee Sok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.309-319
    • /
    • 2013
  • Objective: The aim of this study is to review and summarize human vibration measurement process, and necessity and methods of frequency weightings for human vibration. Background: Prolonged human exposure to hand-arm vibration and whole-body vibration can result in a range of adverse conditions and the development of occupational diseases such as vibration white finger. For preventing these adverse effects, it is important to correctly apply human vibration measurement process. Method: This manuscript was based on the review and summary of mechanical and human vibration relevant texts, academic papers, materials obtained through web surfing. Results: This manuscript summarizes human vibration measurement process described in ISO standards and relevant texts. The sensitivity of the human body to mechanical vibration is known to be dependent on both the frequency and direction of vibration. To take this into account, varying frequency weighting functions have been developed, and RMS frequency-weighted accelerations are used as the most important quantity to evaluate the effects of vibration on health. ISO provided nine frequency weighting functions in the form of curves and tables. Researches on frequency weightings are focused on development and validation of new frequency weightings to truly reflect the relationship between vibration exposure and its adverse effects. Application: This would be useful information for systematically applying human vibration measurement and analysis process, and for selecting appropriate frequency weighting functions.

A Study on Structural Intensity Measurement of 2-dimensional Structure (2차원 구조물의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.3
    • /
    • pp.477-488
    • /
    • 1997
  • In order to control vibration in structures, it is desirable to be able to identify dominant paths of vibration transmission from sources through the structure to some points of interest. Structural intensity vector(power flow per width of cross section) using cross spectra is able to measure the vibration power flow at a point in a structure. This paper describes the structural intensity measurement of 2-dimensional structure. Structural intensity of 2-dimensional structure can be obtained from eight point cross spectral measurement per axis, or two point measurement per axis on the assumption of far field. Approximate formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained on an infinite plate at the near and far field in flexural vibration. The measurement error of two point measurement is rather bigger than eight point measurement on account of the assumption that Poisson's ratio is 1. The structural intensity vectors on the plate are checked the ability to identify the path of vibration power flow in random excitation and 200Hz sine excitation, the result of two point measurememt is almost the same as the result of eight point measurement in 200Hz sine excitation.

  • PDF

Measurement of Vibration Signals of a Gun Barrel Type Structure using Mechanical Filter (기계적 필터를 이용한 포신형상 구조물의 진동신호 측정)

  • Ryu, B.J.;Lee, G.S.;Shin, G.B.;Oh, B.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.181-184
    • /
    • 2007
  • This paper deals with the method of vibration measurement of a gun barrel structure using mechanical filter. When a bullet with high speed is moving within a gun barrel type structure with low bending vibration frequencies, it is difficult to measure the bending vibration signals of the structure. For example, noncontact type sensors such as displacement or velocity sensor are not appropriate for the measurement of vibrational signals because of the movement effect of the equipment frame through the moving structures or effect of the ground vibration. One of contact type sensors such as accelerometer is profitable for measurement of vibrational signals because of its wide measurement ranges. In the case of a gun barrel structure including high vibrational signals like shock waves, however, it is necessary to propose vibration measurement method filtering high frequencies. The purpose of the paper is to propose the proper vibrational measurement technique filtering high frequencies of a gun barrel type structure.

  • PDF

Selection Criteria of Measurement Locations for Advanced Power Reactor 1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program (APR1400 원자로내부구조물 종합진동평가 측정위치 선정 기준)

  • Ko, Do-Young;Kim, Kyu-Hyung;Kim, Sung-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.8
    • /
    • pp.708-713
    • /
    • 2011
  • U.S. nuclear regulatory commission(NRC) regulatory guide(RG) 1.20 requires a comprehensive vibration assessment program(CVAP) for use in verifying the structural integrity of reactor vessel internals(RVI) for flow-induced vibrations prior to commercial operation. The CVAP program consist of vibration and fatigue analysis, a vibration measurement program, an inspection program, and a correlation of their results. One of the main purposes of the analysis program is to select measurement locations, however measurement locations can not be determined by only analysis results, therefore we developed selection criteria of measurement locations for advanced power reactor 1400(APR1400) RVI CVAP, It will be used to select measurement locations and instrument types for APR1400 RVI CVAP.

Estimation of Uncertainty in Vibration Measurement of Shipboard Equipment (함정탑재장비 진동 측정불확도 추정)

  • Park, Sungho;Lee, KyungHyun;Han, HyungSuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.509-516
    • /
    • 2014
  • This paper proposes estimation model of uncertainty in vibration measurement of shipboard equipment and analyzes the result of uncertainty estimation. Vibration of shipboard equipments affects underwater radiated noise that is important performance related to stealth of the naval vessel. Acceptance testing for shipboard equipment is required to guarantee the stealth performance of naval vessel. In measuring, detailed uncertainty estimation is essential to improve measuring reliability. Acceptance testing result of structure-borne noise and vibration is used to analyze uncertainty in vibration measurement of shipboard equipment.