• 제목/요약/키워드: Vibration isolation table

검색결과 57건 처리시간 0.025초

내진시험을 통한 IRB 시스템의 성능 평가 (Performance Evaluation of IRB System Using Seismic Isolation Test)

  • 박영기;하성훈;우제관;최승복;김현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.401-406
    • /
    • 2013
  • This paper presents experimental evaluation of IRE (isolation roller bearing) seismic isolation device. From the combination of base isolation on the IRE system displacement response spectrum and acceleration response spectrum, the compressive strength and the coefficient of friction experiments. Also the IRE system is evaluated by environment test according to KS standards. Both the resonance and seismic experiments using a combination of the IRE and Natural Rubber Bearing (NRB) are performed in order to analyze the seismic isolation of the IRE system dynamic characteristics. For the given load and exciting frequency, the resonant frequency becomes lower, but the resonant magnification remains to be same. However, it is shown that when we consider the IRE only, the vibration on the table with the horizontal movement and the independent horizontal displacement due to the rolling motion of the plate and roller are significantly reduced. This result verifies that the proposed optimal design method of the IRE system is very effective.

  • PDF

위성광학탑재체 개발을 위한 나노급 방진장치 개념 설계 (Concept Design of Vibration Isolation System for Development of Optical Payload of Satellite)

  • 이상훈;조혁진;서희준;김영기;문귀원;문상무;김홍배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.949-952
    • /
    • 2005
  • According to the national space program in Korea, is satellites will be launch into space up to 2015. Especially, KARI is going to develope of its own a high resolution camera of less than 1m to be mounted on next Multipurpose Satellite. When performing testing of large spacecraft or hardware that will be launched into orbit, it is necessary to conduct a testing with space-simulated environment. To achieve this requirement, thermal vacuum chamber is generally used. KARI has been developed a very Large Thermal Vacuum Chamber(LTVC) from 2003 to accomodate future space program, such as KOMPSAT, COMS, and Launch vehicles. This new facility will be used to qualify the first self developed High Resolution Camera, which will be loaded on KOMPSAT-3. To perform an optical test for space camera, it is necessary to provide vibration free environment. Thus the vibration responses on the optical table due to external vibration should be minimized by using a special isolation system. In this paper, we propose the concept design of vibration isolation system for the development of the high resolution camera.

  • PDF

공압능동제어를 이용한 저주파 영역에서의 공압제진대 제진성능 개선에 대한 연구 (Performance Enhancement of Pneumatic Vibration Isolation Tables in Low Frequency by Active Control)

  • 오기용;이정훈;김광준;신윤호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.903-908
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent. use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Dynamic performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by volume of chambers. In this study, an active control technique, so called time delay control which is considered to be adequate for a low frequency or nonlinear system, is applied to a single chamber pneumatic isolator. The procedure of applying the time delay control law to the pneumatic isolator is presented and its effectiveness in enhancement of transmissibility performance is shown based on simulation and experiment. Comparison between passive and active pneumatic isolators is also presented.

  • PDF

멀티 오리피스를 이용한 에어스프링 동특성 개선에 관한 연구 (The Study on the improvement of dynamic characteristics with multi-orifice in airspring)

  • 김인수;황성호;한문성;고철수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.97-103
    • /
    • 2002
  • Vibration isolation technology using an air spring and laminated rubber bearing is widely used because it has excellent vibration isolation characteristics. In the part of that, we usually make use of the self-damped air suing. It is occupied two chambers, restrictor, diaphragm and load plate. Two chambers contain compressed air and the volume of chambers and the area of load plate give a definition of stiffness and load. The restrictor and the volume ratio of two chambers give a definition of damping ratio. The conventional model of restrictor is made of one orifice and it causes turbulent flow in the orifice at the region of large deflection. The stillness of air suing is larger and the damping is lower in the region of large deflection. In the multi-orifice case, the stiffness is similar to air spring with one orifice but damping ratio is larger than conventional air spring. And damping ratio is smaller than conventional air suing in small deflection region. Deflection is small in the region of high frequency so small damping is better than large damping. As a result, we can reduce the storage stiffness of air suing in the wide region of deflection and increase the damping ratio in the region of large deflection. After this, we will try to and the relation of Reynolds Number and Flow Resistance then we are going to make another restrictor for air spring to improve damping ratio and stiffness.

  • PDF

초정밀 스테이지용 능동 진동제어시스템 설계 (Active Vibration Control System Design for Nano-scale Stage)

  • 이주훈;이세한;황돈하;김용주;최영규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2495-2497
    • /
    • 2004
  • A system, featuring the hybrid isolator for control in the vertical direction, of active microvibration control was proposed. The main components of this system are a stage vibration isolation table with built-in acceleration sensors for detecting microvibration, hybrid isolators and a digital controller with high precision signal converters. The vibration control algorithm is focused on settling-time critical application and feedback/feedforward combination.

  • PDF

진동대실험을 통한 원추형 마찰진자베어링의 내진성능 평가 (Seismic Performance Evaluation of Cone-type Friction Pendulum Bearing System Using Shaking Table Test)

  • 전법규;장성진;김남식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.389-394
    • /
    • 2011
  • Existing FPS(Friction Pendulum System) is isolation system which is possible to isolate structures by pendulum characteristic from ground vibration. Structural natural frequency could be decided by designing the radius of curvature of FPS. Thus, response vibration could be reduced by changing natural frequency of structures from FPS. But effective periods of recorded seismic wave were various and estimation of earthquake characteristic could be difficult. If effective periods of seismic wave correspond to natural frequency of structures with FPS, resonance can be occurred. Therefore, CFPBS(Cone-type Friction Pendulum Bearing System) was developed for controlling the response acceleration and displacement by the slope of friction surfaces. Structural natural frequency with CFPBS can be changed according to position of ball on the friction surface which was designed cone-type. Therefore, Divergence of response could be controlled by CFPBS which had constantly changing natural frequency with low modal participation factor in wide-range. In this study, Seismic performance of CFPBS was evaluated by numerical analysis and shaking table test.

  • PDF

면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험 (Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building)

  • 천영수
    • 토지주택연구
    • /
    • 제2권3호
    • /
    • pp.287-297
    • /
    • 2011
  • 본 논문은 적층고무형베어링을 갖는 15층 면진 무량판 아파트건물의 내진거동을 진동대실험을 통하여 검증한 결과를 제시하고 있다. 진동대실험은 중국의 CABR에서 1/10규모의 모형실험체를 대상으로 수행되었다. 실험의 진행은 4개의 지진파를 이용하여 X, Y, X+Y방향으로 다양한 크기의 지진동이 입력되었다. 실험결과, 비 면진건물은 중진레벨에서 진동주기가 현저히 감소하고, 비선형적인 거동을 보였으며, 가속도가 건물의 높이에 따라 현저하게 증가하고, 층간변위도 허용한계를 넘는 거동을 보였다. 반면, 면진건물은 중진레벨에서 거의 일정한 진동주기의 탄성적인 거동을 나타내었으며, 지진하중과 층 가속도가 현저하게 감소하는 응답을 나타내었다. 또한 면진층의 변위는 허용범위 내에서 거동하고, 층간변위는 무시할 수 있을 만큼 작은 강체거동을 나타내었다. 결론적으로 면진은 건물에 대한 지진의 영향을 감소시키는데 매우 효과적이며, 층 가속도의 감소를 통하여 사용성을 증가시키고, 건물 내 설비 등을 안전하게 보호할 수 있음이 입증되었다.