• Title/Summary/Keyword: Vibration frequency

Search Result 6,224, Processing Time 0.034 seconds

경부선 철도 소음진동의 전파특성에 관한 기초 연구 (A Study on the Characteristics of Railroad Noise and Vibration Propagation in KYOUNGBU Line)

  • 김석홍;이성춘;김준호
    • 소음진동
    • /
    • 제3권1호
    • /
    • pp.47-55
    • /
    • 1993
  • In order to maintain comfortable life environment around railroad site, noise from train itself, and to train & rail interaction, and the vibration transmitted through the ground should be controlled to the extent of permissible level. In order to achieve this, the basic railroad noise & vibration data such as magnitude and frequency characteristics of them are necessary to establish the counterplan for railroad noise & vibration. In this study, we measured and analysed the characteristics of time variation, frequency, direction and distance attenuation of noise and vibration of the railroad between Seoul and Pusan.

  • PDF

원통형 압전 변환기의 반경방향 진동 특성 (Radial Vibration of Cylindrical Piezoelectric Transducers)

  • 김진오;정형곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1138-1143
    • /
    • 2001
  • The paper deals with a theoretical study on the radial vibration of cylindrical piezoelectric transducers. The differential equations of piezoelectric radial motion have been derived in terms of the radial displacement and electrical potential. Applying mechanical and electrical boundary conditions has yielded the characteristic equations of natural vibration. Numerical results of the fundamental natural frequency have been compared with experimental observations for the transducers of several sizes, and have shown a good agreement.

  • PDF

격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험 (Detection of Excited Vibration frequency on the Latticed Fence Structure Using a Distributed Fiber Optic Sensor)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.234-237
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber optic external vibration signal spplied to the latticed fence structure from 100Hz to several kHz. The interferometeric fiber optic sensor detected the excited vibration signal very effectively without any signal processing. The detected optical signals were compared and analyzed to the detected acclerometer signals.

  • PDF

풍차형 초음파 전동기 고정자의 공전 및 전동 속도 특성 (Resonance & Vibration Velocity Characteristics of the Wind-mill type Stator of Ultrasonic Motor)

  • 박만주;김영균;김진수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 1998
  • In this study, the wind-mill type ultrasonic motor was fabricated, and then resonant frequency and vibration velocity characteristics of the stator were measured. Brass metal was pressed with umbrella-type using metal mold, then slot of 4 kind was processed in each of thickness. Among sixteen's stators, resonant frequency on vibration velocity was decreased remarkably in stator of higher resonant point, but resonant frequency on vibration velocity wasn't almost changed at lower resonant point of stator. The thickener thickness of elastic body, vibration velocity was decreased. The more slot of elastic body, vibration velocity was increased Applied voltage was changed from 10$V_{max}$ to 100$V_{max}$. Maximum vibration velocity value was 2.0[m/s].

  • PDF

플랜트 설계 시 배관진동을 유발하는 가진 함수의 수학적 모델링 (A Study on Mathematical Modeling of Forcing Function for the Piping Vibration of Petrochemical Plant Design)

  • 민선규;최명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.591-595
    • /
    • 1997
  • In analysis of piping vibration of petrochemical plant, the forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used for the system with rotary equipments. Mechanical driving frequencies, wave functions, and response spectrum are used for reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, for the spray injection case inside the pipe, forcing function was modeled, in which two different fluids are distributed uniformly. To confirm the results, the scheme used for the forcing function was applied for real piping system. The vibration mode of the real system was consistent with the 4th mode obtained by simulation using the forcing function formulated in this study.

  • PDF

대형 잔향실의 방진 설계 및 검증 (Vibration Isolation System of a Large Reverberation Chamber)

  • 김영기;김홍배;이동우;우성현;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

연성평판의 면외 진동인텐시티 측정 (Measurements of the Out-of-Plane Vibration Intensity of Coupled Plate)

  • 전진숙;길현권;이병철;김창열;홍석윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.831-835
    • /
    • 2003
  • The objective of this paper is to suggest an experimental technique to measure the out-of-plane vibration intensity of a coupled plate. In order to measure the out-of-plane vibration intensity of the plate, the frequency response technique has been implemented. In this technique, the 2-D intensity vector at a measurement point has been estimate from the frequency response functions measured at 4 points in the neighborhood of the measurement point. The experimental result has been compared with a theoretical result. It showed that the experimental technique can be effectively used to measure the out-of-plane vibration intensity of plates.

  • PDF

Stick-Slip현상에 의한 V-벨트의 진동과 소음에 관한 실험연구 (Experimental Study of vibration and Noise on Stick-Slip phenomenon of V-belt)

  • 구정태;안세진;정의봉;강종진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.118-121
    • /
    • 2006
  • Stick-slip of belt-pulley system produces vibration which results in the noise problem. Experimental study was carried out to investigate the phenomenon of stick-slip with simple v-belt system. The optical displacement sensor detected the vibration caused by the stick-slip of which the frequency was significantly dependant on tension of the belt. The rotation speed of putties also affected the frequency and magnitude of the stick-slip vibration. Existence of misalignment between the driven and drive pulleys made some difference in the stick-slip frequency, but not much. Further study is necessary to identify the generation of noise from the stick-slip vibration.

  • PDF

열차하중에 의한 인접 지반의 진동 감쇠 특성 분석 (Analysis of Vibration Damping Characteristics of the Ground Nearby Railroad Induced by Train Loading)

  • 이주호;박광순;박경래;염종윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.223-228
    • /
    • 1997
  • In this study, the vibration were measured to analyze the characteristics of propagating vibration on the railroad, the roadbed and the ground nearby railroad induced by traveling trains. About Fifty cases of passing trains were measured with different types and speed, changing the source of loading and the points of measurement. The measured signals were analyzed in time domain and frequency domain. As a result of analysis, sudden reduction of energy was shown in near part from vibration source and the contents of high frequency was reduced more rapidly as the distance was increased. The amplitude of vibration and the contents of frequency did not make big differences in spite of different types of train which is recently used in Korea.

  • PDF

전기적-기계적 수동감쇠기를 이용한 빔의 진동제어 (Vibration Control of Beams Using Mechanical-Electrical Hybrid Passive Damping System)

  • 안상준;박현철;박철휴
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.362-367
    • /
    • 2003
  • A new mechanical-electrical hybrid passive dam ping treatment is proposed to improve the performance of structural vibration control. The proposed hybrid passive damping system consists of a constrained layer damping treatment and a shunt circuit. In a passive mechanical constrained layer damping, a viscoelastic material damping layer is used to control the structural vibration modes in high frequency range. The passive electrical damping is designed for targeting the vibration amplitude in the low frequency range. The governing equations of motion are derived through the Hamilton's principle. The obtained mathematical model is validated experimentally. The presented theoretical and experimental techniques provide invaluable tools for controlling the multiple modes of a vibrating structure over a wide frequency band.

  • PDF