• 제목/요약/키워드: Vibration condition

검색결과 2,072건 처리시간 0.024초

균일한 축방향 유동에 노출된 핵 연료봉의 진동특성 분석 (Vibration Characteristics of a Nuclear Fuel Rod in Uniform Axial Flow)

  • 전상윤;서정민;김규태;박남규
    • 한국소음진동공학회논문집
    • /
    • 제16권11호
    • /
    • pp.1115-1123
    • /
    • 2006
  • Nuclear fuel rods are exposed to axial flow in a reactor, and flow-induced-vibration due to the flow usually causes damage in the fuel rods. Thus a prior knowledge about dynamic behavior of a fuel rod exposed to the flow condition should be provided. This paper shows that dynamic characteristics of a nuclear fuel rod depend on axial flow velocity. Assuming small lateral displacement, the effects of uniform axial flow are investigated. The analytic results show that axial flow generally reduces fuel rod stiffness and raises its damping in normal condition. Also, the critical axial velocities which make the fuel rod behavior unstable were found. That is, solving generalized eigenvalue equation of the fuel rod dynamic system, the eigenvalues with positive real part are detected. Based on the simulation results, on the other hand, it turns out that the ordinary axial flow in nuclear reactors does not affect to stability of a nuclear fuel rod even in the conservative condition.

Condition Monitoring of Low Speed Slewing Bearings Based on Ensemble Empirical Mode Decomposition Method

  • Caesarendra, W.;Park, J.H.;Choi, B.H.;Kosasih, P.B.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.388-393
    • /
    • 2012
  • Vibration condition monitoring at low rotational speeds is still a challenge. Acoustic emission (AE) is the most used technique when dealing with low speed bearings. At low rotational speeds, the energy induced from surface contact between raceway and rolling elements is very weak and sometimes buried by interference frequencies. This kind of issue is difficult to solve using vibration monitoring. Therefore some researchers utilize artificial damage on inner race or outer race to simplify the case. This paper presents vibration signal analysis of low speed slewing bearings running at a low rotational speed of 15 rpm. The natural damage data from industrial practice is used. The fault frequencies of bearings are difficult to identify using a power spectrum. Therefore the relatively improved method of empirical mode decomposition (EMD), ensemble EMD (EEMD) is employed. The result is can detect the fault frequencies when the FFT fail to do it.

  • PDF

압축센싱과 통계학적 기법을 적용한 회전체 시스템의 상태진단 (Application of Compressive Sensing and Statistical Analysis to Condition Monitoring of Rotating Machine)

  • 이명준;전준영;박규해;강토;한순우
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.651-659
    • /
    • 2016
  • Condition monitoring (CM) encounters a large data problem due to sensors that measure vibration data with a continuous, and sometimes, high sampling rate. In this study, compressive sensing approaches for condition monitoring are proposed to demonstrate the efficiency in handling a large amount of data and to improve the damage detection capability of the current condition monitoring process. Compressive sensing is a novel sensing/sampling paradigm that takes much fewer samples compared to traditional sampling methods. For the experiments a built-in rotating system was used and all data were compressively sampled to obtain compressed data. Optimal signal features were then selected without the reconstruction process and were used to detect and classify damage. The experimental results show that the proposed method could improve the data processing speed and the accuracy of condition monitoring of rotating systems.

비선형 경계조건을 가진 보의 정규모드진동 (Normal Mode Vibrations of a Beam with a Nonlinear Boundary Condition)

  • 김현기;이원경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.392-398
    • /
    • 1998
  • In order to check the validity of nonlinear normal modes of continuous, systems by means of the energy-based formulation, we consider a beam with a nonlinear boundary condition. The initial and boundary e c6nsl of a linear partial differential equation and a nonlinear boundary condition is reduced to a linear boundary value problem consisting of an 8th order ordinary differential equations and linear boundary conditions. After obtaining the asymptotic solution corresponding to each normal mode, we compare this with numerical results by the finite element method.

  • PDF

건전도 모니터링을 위한 P.C. 상자형 교량의 동적 특성 분석 (A Study on Dynamic Characteristics of P.C. Box Girder Bridge for Condition Monitoring)

  • 이선구;이성우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.131-137
    • /
    • 1996
  • To perform condition monitoring of P.C. Box girder bridge under ambient traffic, dynamic characteristics were identified using the results of load test an analysis. It was found that natural frequencies obtained from the measured acceleration data for the forced vibration part and free vibration part were nearly identical. Thus it can be concluded that dynamic parameters are properly determined under ambient traffic condition. Finite element model for analysis was calibrated using measured frequencies. Change of dynamic characteristics were predicted through analysis of the established finite element model with anticipated change.

  • PDF

반사면이 존재하는 환경에서 빔포밍 방법을 이용한 부분 음장 재구성 (Partial Field Decompositon Using Beamforming Method Under Reflective Condition)

  • 선종천;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.730-734
    • /
    • 2003
  • A beamforming method is a kind of spatial filter that focus the amy's signal capturing abilities in a desired direction. In this paper, we detect the location of a source under reflective condition using the multi-dimensional MUSIC algorithm then, we can iud the image source locations from the experimental geometry, and we reconstruct the partial fields for direct wave and reflected wave by using Adaptive nulling algorithm. Numerical simulations are performed to verify its performance under various conditions.

  • PDF

흡음재의 적절한 위치 및 임피던스 선정을 통한 효율적인 실내 소음 제어 (Good Choice of Positions and Impedances of Absorptive Materials for Effective Interior Noise Control)

  • 조성호;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.791-796
    • /
    • 2003
  • Some basic guidelines for changing non-uniform boundary condition in an acoustically small cavity are presented. In this paper, modal summation technique is used to represent inside sound field. From this formulation, corner effect is defined and proposed. The corner in a cavity is good position for changing boundary condition effectively. Impedance circle with same absorption coefficient is defined to find appropriate impedance of absorptive material for better noise control performance.

  • PDF

자동차 부품에 대한 다축 진동내구 시험용 신호처리 방법 (Signal Processing for Multiaxial Vibration Fatigue Test on Vehicle Component)

  • 배철용;김찬중;이동원;이봉현;나병철
    • 한국소음진동공학회논문집
    • /
    • 제18권3호
    • /
    • pp.368-374
    • /
    • 2008
  • Multi-axial simulation table(MAST) is widely used in motor companies as the multi-axial excitor for vibration fatigue of target component, which provides the vibrational condition as close as the vehicle test. However, the vibration fatigue performance of target component can be guaranteed with MAST system only in case the input profile covers the required severity of the target component on field test. In this paper, the signal processing for multi-axial vibration fatigue test on vehicle component is presented, from the data acquisition of the target component to the derivation of input profile. To compare the severity of vibration condition between field and proving ground, the energy principle of a equivalent damage is proposed and then, it is determined the optimal combination of special events on proving ground using a sequential searching optimal algorithm. To explain the vibration methodology clearly, seat and door component of vehicle are selected as a example.

부분적으로 유체가 채워진 원통형 관내의 외팔보 진동해석 (Vibration Analysis of an Cantilever Beam in Partially Liquid-Filled Cylindrical Pipe)

  • 권대규;유계형;방두열;이성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1073-1078
    • /
    • 2003
  • This paper presents the vibration characteristics of a cantilever beam in contact with a fluid using a PZT actuator and PVDF film. dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition un the fluid domain. In the vibration analysis of a wetted beam. the decoupled analyses between beam and fluid have been conventionally employed by considering first the composite beam vibration in the all and secondly Performing the correction taking account for surrounding fluid effects. That is, this investigation was to look at how natural frequencies, mode shapes. and damping are affected by liquid level variations. The signals from the sensor according to the applied input voltage are digitalized and filtered in order to obtain the dynamic characteristics of the composite beam in contact with fluid. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level between 20% and 80% in the first tending mode and we found out the bends of stair shape for added mass effect of the fluid.

  • PDF

구조물의 진동장 예측 최적센서배치를 위한 유전자 알고리듬 적합함수의 선정 (Selection of Fitness Function of Genetic Algorithm for Optimal Sensor Placement for Estimation of Vibration Pattern of Structures)

  • 정병규;배경원;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제25권10호
    • /
    • pp.677-684
    • /
    • 2015
  • It is often necessary to predict the vibration patterns of the structures from the signals of finite number of vibration sensors. This study presents the optimal placement of vibration sensors by applying the genetic algorithm and the modal expansion method. The modal expansion method is used to estimate the vibration response of the whole structure. The genetic algorithm is used to estimate the optimal placement of vibration sensors. Optimal sensor placement can be obtained so that the fitness function is minimized in the genetic algorithm. This paper discusses the comparison of the performances of two types of fitness functions, modal assurance criteria(MAC) and condition number( CN). As a result, the estimation using MAC shows better performance than using CN.