• 제목/요약/키워드: Vibration Motor

검색결과 1,350건 처리시간 0.03초

인버터 압축기의 강체 거동 해석 (Dynamic Analysis of an Inverter Motor Driven Compressor)

  • 강정훈;정정교;김용태;주재만;서문희;이성태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.79-82
    • /
    • 2004
  • In general, compressors for refrigerators are major noise source in home environment. The vibration originated from a pump of a compressor can make noise through suspension springs and a LDT(Line Discharge Tube). Especially for the inverter motor driven compressor, the vibration is more serious than it of the constant speed compressors. Because the operation frequency range of an inverter motor driven compressor is very wide from 1600 rpm to 4200 rpm. In this paper, we propose the numerical model to reduce vibration by designing weight balancers and grommets. Results for analytical investigations on the exciting force and moment at the pump mass center, weight balancers and exciting frequency variation are presented.

  • PDF

영구자석 스프링과 보이스 코일 구동기를 가진 직선형 진동모터의 설계 및 해석 (Design and Analysis of Linear Vibration Motor Equipped with Permanent-Magnet Springs and Voice-Coil Actuators)

  • 최정규;유승열;노명규
    • 대한기계학회논문집A
    • /
    • 제37권3호
    • /
    • pp.359-364
    • /
    • 2013
  • 직선형 진동모터가 휴대전화의 알림용이나 햅틱 인터페이스의 구동기로 적용되려면 빠른 응답속도와 긴 수명을 제공하여야 한다. 본 논문에서는 기존 직선형 진동모터를 개선하여 보이스 코일 구동기와 영구자석 스프링을 이용한 직선형 진동모터를 제시하고, 설계 제작하여 그 가능성을 검증하였다. Halbach 배열의 영구자석에 의해 구동되는 보이스 코일 구동기와 영구자석 간의 반발력을 이용하는 영구자석 스프링을 해석하고 설계하기 위해, 등가전류판 방법과 이미지 방법을 사용하였고, 방법의 적절성을 유한요소해석을 통해 검증하였다. 시작품 모터를 설계하고 제작하고, 실험을 통해 진동모터의 특성을 확인하였다.

베어링 재설계에 의한 원전 COP motor의 진동 제어 (Vibration Control of Condensate Motors in Nuclear Powerplant By Bearing Redesign)

  • 임도형;김원현;이종문;이수목
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the summary of control of abnormal vibration found in the COP motors of a nuclear power plant. All six identical units of COP pump-motor assemblies showed unstable vibration pattern of which one or two showed higher vibration enough to exceed the allowable level from the installation stage. Many trials of test, measurement, overhaul and replacement had been repeated to investigate and solve the problem but only to reach unsatisfactory settlement. Recently several times of site tests are made and followed by significant diagnostic actions in which the authors group participated. It was found that the coupled shafting system of motor and pump is in close resonance with the $1^{st}$ shaft rotating speed. Redesign of topside motor bearing clearance is made to increase bearing stiffness and hence to avoid the resonance which consequently led to reduce the troubled vibration to allowable and stable status.

  • PDF

전자기력에 의한 능동 동흡진기의 진동제어성능에 관한 연구 (A Study on Vibration Control using Active Dynamics Damper with Linear Electric Motor)

  • 고우식;박노길;노철웅;성기대;이인우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.163-168
    • /
    • 1996
  • In this paper a new dynamic damper driven by DC linear electric motor, is proposed for suppressing wide-band vibration. First, the reason for the incapability of a conventional dynamic damper to suppress wide-band vibration is explained. Then, with its defects taken into consideration, the principle of wide-band vibration control is presented. Finally, experiments ar conducted verifying the control effect of the active dynamic damper for suppressing wide-band vibration.

  • PDF

회귀 분석을 이용한 소형유니버셜 모터의 진동 분석 (Vibration Reduction of a Small Universal Motor using Regression Analysis)

  • Cha, W. J.;Choi, Y. S.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.316.1-316
    • /
    • 2002
  • The regression analysis in the six sigma process is used to reduce the vibration of a small universal motor, The vibration characteristics and contribution of each part to overall vibration of an electric grinder is investigated through various vibration measurements and frequency analysis for the assembled and disassembled one. (omitted)

  • PDF

회전자 편심을 가지는 IPM, SPM 전동기 진동 특성 비교: (1) 영구 자석에 의한 전자기력 (Comparison of Vibration Characteristics in IPM and SPM BLDC Motors with Rotor Eccentricity : (1) Electro-magnetic Force Due to PM)

  • 황근배;김경태;황상문
    • 한국소음진동공학회논문집
    • /
    • 제11권9호
    • /
    • pp.454-461
    • /
    • 2001
  • Acoustic noise and vibration of a BLDC motor is a coupled phenomenon between mechanical characteristics and electromagnetic origins through the motor air-gap. When a relative misalignment of rotor in the air-gap center exists on the assemblage, it is considered to influence the motor system characteristics. In this paper, the back electro motive force(BEMF) is analyzed by Finite Element Method(FEM) and verified by experiments for the SPM and IPM type motors. For magnetic field analysis, a FEM is used to account for the magnetic saturation. Using these results, the FEM is made to determine the appropriate electromagnetic field analysis in BLDC motors with rotor eccentricity ratio. A radial magnetic imbalance force of BLDC motor with rotor eccentricity is analyzed. Results demonstrate that the imbalance force is increased according to the degree of misalignment. An IPM motor, mostly chosen to realize high-speed operation, shows a worse effect on magnetic unbalanced forces and dynamic responses compared with SPM motor due to magnetic saturation when the rotor eccentricity exists.

  • PDF

The Vibration Suppressible Method with Estimated Torsion Torque Feedback in Fuzzy Controller

  • Choo, Yeon-Gyu;Lee, Kwang-Seok;Kim, Hyun-Deok;Kim, Bong-Gi
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.421-424
    • /
    • 2008
  • In torque transmission system, we must suppressed vibration for Accuracy characteristic response of motor, Therefore, vibration suppression factor is very important motor control. To suppress vibration, a various control method has been proposed. Specially, one method of vibration suppression used disturbance observer filter. This method is torsion torque passing disturbance observer filter. By the estimated torsion torque feedback, vibration can be suppressed. The CDM(coefficient diagram method) is used to design the filter and Proportional controller. But using coefficient diagram method, not adapted controller parameter in disturbance. For this solution, we used fuzzy controller for auto tuning controller parameter. We proved this approach is confirmed by simulation.

IPM type BLDC 전동기의 진동저감을 위한 회전자 형상설계 (The Rotor Shape Design of IPM Type BLDC Motor for Minimization of Vibration)

  • 류진욱;강규홍;허진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.895_896
    • /
    • 2009
  • this paper presents a rotor shape optimization of interior type permanent magnet (IPM) motor for vibration minimization. the vibration of permanent magnet motor is generated by cogging torque, radial force and commutation torque ripple which are electromagnetic source of vibration. In order to minimize the vibration, the optimal notches are put on the rotor pole face and the arc type pole face is applied. The variations of cogging torque and radial force of each model vibration frequency are computation by finite element method (FEM) and the validity of the analysis and rotor shape design is confirmed by vibration experiments.

  • PDF

Effects of Slot Combination and Skewed Slot on the Electromagnetic Vibration of a 4-pole Capacitor Motor under Load Condition

  • Hirotsuka Isao;Tsubouchi Yutaro;Tsuboi Kazuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.85-91
    • /
    • 2006
  • Recently, the reduction of electromagnetic vibration and noise of a capacitor motor (CRM) has become a very important subject from the standpoint of environmental improvement. Therefore, the authors have studied the characteristics of the dominant electromagnetic vibration of the CRM under load condition. In this paper, the effects of slot combination and skewed slot on the dominant electromagnetic vibration of a CRM under load condition are discussed both theoretically and experimentally. As a result, the characteristics of the dominant electromagnetic vibration for the slot combination and the reduction effect of the skewed slot on the electromagnetic vibration are clarified for a 4-pole CRM.

The Design of Adaptive Fuzzy Controller for Vibration Suppression

  • Kim, Seung-Cheol;Sul, Jae-Hoon;Park, Jae-Hyung;Lim, Young-Do;Park, Book-Kwi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.41.2-41
    • /
    • 2001
  • A torque transmission system, which is composed of several gears and couplings, is flexible. Therefore, the torsion vibration occurs when the motor speed abruptly changes. Consequently, for Accuracy characteristic response of motor, we must suppressed vibration. Therefore, vibration suppression is very important motor control. To vibration suppression, various control method have been proposed. Specially, one method of vibration suppression used disturbance observer filter. This method is torsion torque passing disturbance observer filter. By feedback of the estimated torsion torque, the vibration can be suppressed The coefficient diagram method is used to design the filter and proportional controller.

  • PDF