• 제목/요약/키워드: Vibrating device

검색결과 67건 처리시간 0.03초

Vibration Measurements in the Mining Industry Applying the Software Install Application to the Kosovo Energy Corporation

  • Luzha, Ibush;Baftiu, Naim;Maloku, Betim;Qarkaxhija, Jusuf
    • International Journal of Computer Science & Network Security
    • /
    • 제22권8호
    • /
    • pp.362-370
    • /
    • 2022
  • The assessment of specific impacts on the environment is a preventive measure for environmental protection which is based on the definition and proposal of measures that can prevent harmful effects, reduce or eliminate them. In the physical sense, vibration is the oscillating motion of an object with the effect of internal or external forces applied to it. People who touch a vibrating surface or object will feel these vibrations. In general, there are two types of vibration exposure. The first are the vibrations of the hands and arms transmitted by the held parts of tools or machinery. The second are whole-body vibrations transmitted from a seat or surface to a motorized car. The risk of injury to workers exposed to vibration varies depending on the size, frequency, type, duration of exposure, and organ affected. The purpose of this paper is to review the measurements of vibrations in the Kosovo Energy Corporation in the mine Sibovc Southwest, where coal with a rotary excavator is exploited and the evaluation of vibrations for working conditions for workers working in that environment and improving working conditions for the measurement of vibrations we have used the device Minimate DS 078, the purpose of such environmental impact assessment is to collect data and predict the harmful impacts on the environment, namely the impact on water, air, soil, life and health of as well as identify and propose measures that could prevent, reduce or eliminate altogether.

Compound damping cable system for vibration control of high-rise structures

  • Yu, Jianda;Feng, Zhouquan;Zhang, Xiangqi;Sun, Hongxin;Peng, Jian
    • Smart Structures and Systems
    • /
    • 제29권4호
    • /
    • pp.641-652
    • /
    • 2022
  • High-rise structures prone to large vibrations under the action of strong winds, resulting in fatigue damage of the structural components and the foundation. A novel compound damping cable system (CDCS) is proposed to suppress the excessive vibrations. CDCS uses tailored double cable system with increased tensile stiffness as the connecting device, and makes use of the relative motion between the high-rise structure and the ground to drive the damper to move back-and-forth, dissipating the vibration mechanical energy of the high-rise structure so as to decaying the excessive vibration. Firstly, a third-order differential equation for the free vibration of high-rise structure with CDCS is established, and its closed form solution is obtained by the root formulas of cubic equation (Shengjin's formulas). Secondly, the analytical solution is validated by a laboratory model experiment. Thirdly, parametric analysis is conducted to investigate how the parameters affect the vibration control performance. Finally, the dynamic responses of the high-rise structure with CDCS under harmonic and stochastic excitations are calculated and its vibration mitigation performance is further evaluated. The results show that the CDCS can provide a large equivalent additional damping ratio for the vibrating structures, thus suppressing the excessive vibration effectively. It is anticipated that the CDCS can be used as a good alternative energy dissipation system for vibration control of high-rise structures.

혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성 (Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device)

  • 김기범;권대규;정경락;이삼철
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권2호
    • /
    • pp.121-126
    • /
    • 2003
  • 본 연구는 진동형 장치의 활용을 통해 혈관 내 폐 보조장치의 기체전달 효율을 향상시키고자 시도하였으며, 진동에 따른 혈액의 용혈 문제에 있어서 한계 용혈이 발생하는 영역을 선정하고자 하였다. 가진 주파수가 0 Hz일 때를 기준으로 하여 중공사 수의 변화에 따라 산소전달속도를 측정하였다. 최대의 산소전달속도를 나타내는 중공사 모듈에서 가진 주파수의 변화에 따른 산소전달속도를 측정하고 혈액의 용혈도를 측정하였다. 측정결과 액체 유속의 변화에 따라 최대 산소전달속도를 나타내는 중공사 모듈은 type 6으로 이때의 중공사 개수는 675개이다. 또한, 중공사를 가진하지 않았을 때 최대의 산소전달속도를 보여주는 모듈은 type 6이었다. 모듈 type 6의 가진 주파수의 변화에 따른 산소전달속도는 7 Hz에서 최대산소전달속도를 나타내었으며 최대산소전달속도를 나타내는 7 Hz의 가진 주파수에서의 혈액 용혈도를 측정한 결과 혈액의 용혈도는 낮았다. 그러므로 최대 흔들림이 일어나는 7 Hz를 한계 용혈 주파수로 결정할 수 있었다.

적외선 센서와 압력센서를 이용한 시각장애인용 보행보조신발 (Walking Assistive Shoes for Visually Impaired Person Using Infrared Sensor and Pressure Sensor)

  • 양창민;정지용;김정자
    • 재활복지공학회논문지
    • /
    • 제11권2호
    • /
    • pp.147-156
    • /
    • 2017
  • 시각장애인의 보행보조도구인 흰 지팡이는 보행에 필요한 정보인 장애물의 유무를 직접 접촉해야만 인식할 수 있으며 지면의 낮은 장애물을 탐지하기 어렵다는 단점이 있다. 최근 이러한 문제들을 해결하기 위해 새로운 보행보조도구들이 개발되고 있지만 개발된 도구들의 외형과 높은 가격으로 인해 많이 사용되지 못하고 있다. 이에 본 논문에서는 적외선 센서와 압력 센서, 진동 모터를 사용하여 두 가지 유형의 보행보조신발을 제작하였다. 두 가지 유형의 보행보조신발은 장착된 적외선 센서의 개수에 따라 단일 센서 (SS)와 이중 센서 유형(DS)으로 분류하였다. 유효성 평가를 위해 장애물이 배치된 공간에서 보행 보조 신발과 흰 지팡이를 가지고 보행할 때 나타나는 보행 소요 시간과 충돌 횟수를 비교하였다. 실험 결과, 개발된 보행보조신발 사용 시 지팡이에 비해 소요시간이 증가하였으나 충돌 횟수는 감소하였다. 또한, 보행보조신발 사용 시 흰 지팡이에 비해 이동시간과 충돌횟수가 더욱 크게 감소하였다. 따라서 개발된 보행보조신발이 시각장애인의 안전한 보행 환경을 제공하고 새로운 형태의 보행보조도구에 적응하는 시간을 감소시키는데 큰 도움을 줄 수 있을 것으로 사료된다.

Factors Affecting Discrimination of Surface Property Using an Integrated Tactile Display;Roughness and Vibration

  • Jeong, Young-Ju;Yang, Gi-Hun;Kyung, Ki-Uk;Kwon, Dong-Soo;Kang, Sung-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.596-601
    • /
    • 2004
  • In this paper, we describe a study on the influence of the frequency variation of normal vibration using an integrated tactile display. It is necessary to consider this study because we want to find a method of displaying finer texture and know that the perception of fine textures is heavily influenced by temporal variation. Our tactile display system used in this experiment can simulate the micro shapes and roughness of surface textures by individual drives of a 6x8 pin array. Two experiments are performed. The first is a psychophysical experiment on the definition and range decision of roughness, and through the experiment, we clear up the meaning of roughness. The second is the main experiment about the frequency variation of normal vibration. We find the correlation between the vibration frequency and the texture and the condition for better display and perception of fine surfaces. The experimental results yielded two pieces of information. One is that lateral movement affects texture discrimination, and another is that normal vibration can make the perceived texture feel finer than real texture. That is, the vibrating stimulus is more effective for displaying a fine surface than static pressure, and it makes possible to display finer texture, exceeding the physical limit of the device.

  • PDF

Effect of Ni dopant on the multiferroicity of BiFeO3 ceramic

  • Hwang, J.S.;Yoo, Y.J.;Kang, J.H.;Lee, K.H.;Lee, B.W.;Park, S.Y.;Lee, Y.P.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.139.1-139.1
    • /
    • 2016
  • Multiferroic materials are of great interest because of its potential applications in the design of devices combining magnetic, electronic and optical functionalities. Among various multiferroic materials, $BiFeO_3$(BFO) is known to be one of the intensively focused mainly due to the possibility of multiferroism at device working temperature (> $200^{\circ}C$). However, leakage current and weak polarization resulting from oxygen deficiency and crystalline defect should be resolved. Furthermore the magnetic ordering of pure BFO mainly prefers to have antiferromagnetic coupling. Up to now many attempts have been performed to improve the ferromagnetic and the ferroelectric properties of BFO by doping. In this work, we investigated the effects of Ni substitution on the multiferroism of bulk BFO. Four BFO samples (a pure BFO and three Ni-doped BFO's; $BiFe_{0.99}Ni_{0.01}O_3$, $BiFe_{0.98}Ni_{0.02}O_3$ and $BiFe_{0.97}Ni_{0.03}O_3$) were synthesized by the standard solid-state reaction and rapid sintering technique. The XRD results reveal that Ni atoms are substituted into Fe-sites and give rise to phase transition of cubic to rhombohedal. By using vibrating sample magnetometer and standard ferroelectric tester, the multiferroic properties at room temperature were characterized. We found that the magnetic moment of Ni-doped BFO turned out to be maximized for 3% of Ni dopant.

  • PDF

소립종자용 평면배열 진공노즐식 반자동 파종기 개발에 관한 연구 (Development of a Semi-automatic Seeder with Vacuum Nozzles of Quadratic Arrangement for Small-sized Seeds)

  • 김동억;이공인;강동현;김유호;이혜진;김현환;김종구;김용현
    • Journal of Biosystems Engineering
    • /
    • 제36권6호
    • /
    • pp.434-443
    • /
    • 2011
  • A large scale seeding system was stable in terms of techniques but a convenient seeding system of small size was unsettled. This study was performed to develop a semi-automatic seeder for small and medium sized scale farm. To investigate optimum needle diameter and vacuum pressure was used vacuum suction needle seeder. Although the needle diameter according to the kinds of seed was different, the needle diameter for salvia and lettuce seed was suitable for 0.34 mm needle nozzle and 0.4 mm taper nozzle. The prototype consisted a seeding frame attached with needle nozzle, seed hopper, vibrating device, seeding part, vacuum ejector, seed tube etc.. As the result with the experiments, the seeding rate of the seeder was 92% and more at 0.34 mm diameter needle nozzle and 0.4 mm taper nozzle. Eccentric weight for seed hopper vibration was suitable that weight is 11 g and eccentric distance is 0.5 mm. Vibration acceleration of upward direction was 0.363 m/$s^2$. Working capacity of the seeder was possible 160 trays per hour. It was possible for sowing small seeds but it was required to make compact and simple model.

힌지구조 진동절단장치에 관한 연구 (Study on Vibrated Cutting Blade with Hinge Mechanism)

  • 강동배;안중환;손성민
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.443-448
    • /
    • 2010
  • 기능이 극대화된 초소형 전자기기를 제조하기 위해 사용되는 적층형 소자들 중, 적층 세라믹 콘덴서(MLCC: Multi Layer Ceramic Capacitor)는 휴대전화, 노트북 등에 전자회로의 평활, 안정화, 노이즈 제거, 커플링 등 다양한 용도로 사용되고 있다. 적층형 세라믹 콘덴서는 생산과정에서 압축소결된 미세 다층구조의 적층형 소자 바(bar)를 하나 하나의 칩으로 절단하여야 한다. 현재 적용되고 있는 cutting, dicing 등의 방법을 대신하여 수율의 향상을 도모하기 위해 진동절삭법을 적용하여 그 특성을 조사하였다. 유연 힌지구조를 이용한 진동 절단 구조를 설계하고 해석하여 적층형 세라믹 콘덴서의 절단에 알맞은 진동절단기구를 제안한다. 또한, 설계결과를 바탕으로 제작된 진동절단 기구의 절단가공 특성을 조사하여 기존 절단법과의 성능비교를 통해 힌지 구조를 이용한 진동 절단의 타당성을 검증하였다.

Rod Milling에 의해 제작된 비평형 Al(Fe-Cu) 합금 분말의 형성 및 Chemical Leaching (Formation and Chemical Leaching of a Non-Equilibrium Al(Fe-Cu) Alloy Powder produced by Rod-Milling)

  • 김현구;명화남
    • 한국분말재료학회지
    • /
    • 제9권5호
    • /
    • pp.359-364
    • /
    • 2002
  • We report the structure, thermal and magnetic properties of a non-equilibrium $Al_{0.6}(Fe_{50}Cu_{50})_{0.4}$ alloy powder produced by rod milling and chemical leaching. An X-ray diffractometry(XRD), a transmission electron microscope(TEM), a differential scanning calorimeter(DSC), a vibrating sample magnetometer(VSM), and superconducting quantum interference device(SQUID) were utilized to characterize the as-milled and leaching specimens. The crystallite size reached a value of about 8.82 nm. In the DSC experiment, the peak temperatures and crystallization temperatures decreased with increasing milling time. The activation energy of crystallization is 200.5 kJ/mole for as-milled alloy powder. The intensities of the XRD peaks of as-milled powders associated with the bcc type $Al_{0.5}Fe_{0.5}$ structure formative at $350^{\circ}C$ sharply increase with increasing annealing temperature. Above $400^{\circ}C$, peaks alloted to $Al_{0.5}Fe_{0.5}$ and $Al_{5}Fe_{2}$ are observed. After annealing at $600^{\circ}C$ for 1h, the leached Ll specimen transformed into bcc $\alpha$-Fe and fcc Cu phases, accompanied by a change in the structural and magnetic properties. The saturation magnetization decreased with increasing milling time, and a value of about 8.42 emu/g was reached at 500 h of milling. The coercivity reached a maximum value of about 142.7 Oe after 500 h of milling. The magnetization of leached specimens as function of fields were higher at 5 K, and increased more sharply at 5 K than at 100 K.

전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석 (Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact)

  • 김두현;황동규
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.