Browse > Article
http://dx.doi.org/10.12989/sss.2022.29.4.641

Compound damping cable system for vibration control of high-rise structures  

Yu, Jianda (School of Civil Engineering, Hunan University of Science and Technology)
Feng, Zhouquan (College of Civil Engineering, Hunan University)
Zhang, Xiangqi (School of Civil Engineering, Hunan University of Science and Technology)
Sun, Hongxin (School of Civil Engineering, Hunan University of Science and Technology)
Peng, Jian (School of Civil Engineering, Hunan University of Science and Technology)
Publication Information
Smart Structures and Systems / v.29, no.4, 2022 , pp. 641-652 More about this Journal
Abstract
High-rise structures prone to large vibrations under the action of strong winds, resulting in fatigue damage of the structural components and the foundation. A novel compound damping cable system (CDCS) is proposed to suppress the excessive vibrations. CDCS uses tailored double cable system with increased tensile stiffness as the connecting device, and makes use of the relative motion between the high-rise structure and the ground to drive the damper to move back-and-forth, dissipating the vibration mechanical energy of the high-rise structure so as to decaying the excessive vibration. Firstly, a third-order differential equation for the free vibration of high-rise structure with CDCS is established, and its closed form solution is obtained by the root formulas of cubic equation (Shengjin's formulas). Secondly, the analytical solution is validated by a laboratory model experiment. Thirdly, parametric analysis is conducted to investigate how the parameters affect the vibration control performance. Finally, the dynamic responses of the high-rise structure with CDCS under harmonic and stochastic excitations are calculated and its vibration mitigation performance is further evaluated. The results show that the CDCS can provide a large equivalent additional damping ratio for the vibrating structures, thus suppressing the excessive vibration effectively. It is anticipated that the CDCS can be used as a good alternative energy dissipation system for vibration control of high-rise structures.
Keywords
compound damping cable system; equivalent additional damping ratio; high-rise structure; parametric analysis; vibration control;
Citations & Related Records
Times Cited By KSCI : 10  (Citation Analysis)
연도 인용수 순위
1 Huang, Z.W., Hua, X.G., Chen, Z.Q. and Niu, H.W. (2018), "Modeling, Testing, and Validation of an Eddy Current Damper for Structural Vibration Control", J. Aerosp. Eng., 31(5), 04018063. https://doi.org/10.1061/(ASCE)AS.1943-5525.0000891   DOI
2 Ikago, K., Sugimura, Y., Saito, K. and Inoue, N. (2012b), "Modal Response Characteristics of a Multiple-Degree-Of-Freedom Structure Incorporated with Tuned Viscous Mass Dampers", J. Asian Architect. Build. Eng., 11(2), 375-382. https://doi.org/10.3130/jaabe.11.375   DOI
3 Ikago, K., Saito, K. and Inoue, N. (2012a), "Seismic control of single-degree-of-freedom structure using tuned viscous mass damper", Earthq. Eng. Struct. Dyn., 41(3), 453-474. https://doi.org/10.1002/eqe.1138   DOI
4 Shi, X., Zhu, S., Li, J.-Y. and Spencer Jr., B.F. (2016), "Dynamic behavior of stay cables with passive negative stiffness dampers", Smart Mater. Struct., 25(7), 075044. https://doi.org/10.1088/0964-1726/25/7/075044   DOI
5 Lazar, L.F., Neild, S.A. and Wagg, D.J. (2014), "Using an inerter-based device for structural vibration suppression", Earthq. Eng. Struct. Dyn., 43(8), 1129-1147. https://doi.org/10.1002/eqe.2390   DOI
6 Li, H., Liu, M., Li, J., Guan, X. and Ou, J. (2007), "Vibration Control of Stay Cables of the Shandong Binzhou Yellow River Highway Bridge Using Magnetorheological Fluid Dampers", J. Bridge Eng., 12(4), 401-409. https://doi.org/10.1061/(ASCE)1084-0702(2007)12:4(401)   DOI
7 Liang, L., Feng, Z. and Chen, Z. (2019), "Seismic control of SDOF systems with nonlinear eddy current dampers", Appl. Sci., 9(16), 3427. https://doi.org/10.3390/app9163427   DOI
8 Lin, W.-H. and Chopra, A.K. (2002), "Earthquake response of elastic SDF systems with non-linear fluid viscous dampers", Earthq. Eng. Struct. Dyn., 31(9), 1623-1642. https://doi.org/10.1002/eqe.179   DOI
9 Liu, W., Guo, Y., Dong, X. and He, W. (2019), "Earthquake response control of a super high-rise structure subjected to long-period ground motions via a novel viscous damped system with multilever mechanism", Struct. Des. Tall Special Build., 28(7), e1600. https://doi.org/10.1002/tal.1600   DOI
10 Sun, H., Zuo, L., Wang, X., Peng, J. and Wang, W. (2019b), "Exact H 2 optimal solutions to inerter-based isolation systems for building structures", Struct. Control Health Monitor., 26(6), e2357. https://doi.org/10.1002/stc.2357   DOI
11 Wen, Y., Chen, Z. and Hua, X. (2017), "Design and Evaluation of Tuned Inerter-Based Dampers for the Seismic Control of MDOF Structures", J. Struct. Eng., 143(4), 04016207. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001680   DOI
12 Duan, Y., Ni, Y.-Q., Zhang, H., Spencer, B.F.J., Ko, J.-M. and Fang, Y. (2019), "Design formulas for vibration control of taut cables using passive MR dampers", Smart Struct. Syst., Int. J., 23(6), 521-536. https://doi.org/10.12989/sss.2019.23.6.521   DOI
13 Feng, Z.Q., Zhao, B., Hua, X.G. and Chen, Z.Q. (2019), "Enhanced EMD-RDT Method for Output-Only Ambient Modal Identification of Structures", J. Aerosp. Eng., 32(4), 04019046. https://doi.org/10.1061/(ASCE)AS.1943-5525.0001034   DOI
14 Kim, H.-K., Kim, K.-T., Lee, H. and Kim, S. (2013), "Performance of Unpretensioned Wind Stabilizing Cables in the Construction of a Cable-Stayed Bridge", J. Bridge Eng., 18(8), 722-734. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000405   DOI
15 Li, L., Song, G. and Ou, J. (2011), "Hybrid active mass damper (AMD) vibration suppression of nonlinear high-rise structure us-ing fuzzy logic control algorithm under earthquake excitations", Struct. Control Health Monitor., 18(6), 698-709. https://doi.org/10.1002/stc.402   DOI
16 Ni, Y.Q., Wang, J.Y. and Lo, L.C. (2005), "Influence of Stabilizing Cables on Seismic Response of a Multispan Cable Stayed Bridge", Comput.-Aided Civil Infrastruct. Eng., 20(2), 142-153. https://doi.org/10.1111/j.1467-8667.2005.00383.x   DOI
17 Niu, H., Chen, Z., Hua, X. and Zhang, W. (2018), "Mitigation of wind-induced vibrations of bridge hangers using tuned mass dampers with eddy current damping", Smart Struct. Syst., Int. J., 22(6), 727-741. https://doi.org/10.12989/sss.2018.22.6.727   DOI
18 Pan, C., Zhang, R., Luo, H., Li, C. and Shen, H. (2018), "Demand-based optimal design of oscillator with parallel-layout viscous in-erter damper", Struct. Control Health Monitor., 25(1), e2051. https://doi.org/10.1002/stc.2051   DOI
19 Ahmad, J., Cheng, S. and Ghrib, F. (2018), "Combined effect of external damper and crosstie on the modal response of hybrid two-cable networks", J. Sound Vib., 417, 132-148. https://doi.org/10.1016/j.jsv.2017.12.023   DOI
20 Benavent-Climent, A. (2011), "An energy based method for seismic retrofit of existing frames using hysteretic dampers", Soil Dyn. Earthq. Eng., 31(10), 1385-1396. https://doi.org/10.1016/j.soildyn.2011.05.015   DOI
21 Caracoglia, L. and Jones, N.P. (2007), "Passive hybrid technique for the vibration mitigation of systems of interconnected stays", J. Sound Vib., 307(3-5), 849-864. https://doi.org/10.1016/j.jsv.2007.07.022   DOI
22 Roy, S., Park, Y.C., Sause, R. and Fisher, J.W. (2012), "Fatigue Performance of Stiffened Pole-to-Base Plate Socket Connections in High-Mast Structures", J. Struct. Eng., 138(10), 1203-1213. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000554   DOI
23 Lu, X., Zhang, Q., Weng, D., Zhou, Z., Wang, S., Mahin, S.A., Ding, S. and Qian, F. (2017), "Improving performance of a super tall building using a new eddy-current tuned mass damper", Struct. Control Health Monitor., 24(3), e1882. https://doi.org/10.1002/stc.1882   DOI
24 Sorace, S. and Terenzi, G. (2012a), "The damped cable system for seismic protection of frame structures - Part I: General concepts, testing and modeling", Earthq. Eng. Struct. Dyn., 41(5), 915-928. https://doi.org/10.1002/eqe.1166   DOI
25 Suarez, E., Roldan, A., Gallego, A. and Benavent-Climent, A. (2017), "Entropy analysis for damage quantification of hysteretic dampers used as seismic protection of buildings", Appl. Sci., 7(6), 628. https://doi.org/10.3390/app7060628   DOI
26 Sun, C., Jahangiri, V. and Sun, H. (2019a), "Performance of a 3D pendulum tuned mass damper in offshore wind turbines under multiple hazards and system variations", Smart Struct. Syst., Int. J., 24(1), 53-65. https://doi.org/10.12989/sss.2019.24.1.053   DOI
27 Choi, S.-W. and Kim, H.-K. (2008), "Design of aerodynamic stabilizing cables for a cable-stayed bridge during construction", Wind Struct., Int. J., 11(5), 391-411. https://doi.org/10.12989/was.2008.11.5.391   DOI
28 Yu, J., Tang, Y., Zhu, Y., Yu, P. and Wang, X. (2014), "A compound damping cable system", Chinese Invention Patent, CN104404886B.
29 Wang, Z., Gao, H., Xu, Y., Chen, Z. and Wang, H. (2019a), "Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations", Smart Struct. Syst., Int. J., 24(1), 83-94. https://doi.org/10.12989/sss.2019.24.1.083   DOI
30 Wang, Z.H., Xu, Y.W., Gao, H., Chen, Z.Q., Xu, K. and Zhao, S.B. (2019b), "Vibration control of a stay cable with a rotary electromagnetic inertial mass damper", Smart Struct. Syst., Int. J., 23(6), 627-639. https://doi.org/10.12989/sss.2019.23.6.627   DOI
31 Yamaguchi, H. and Nagahawatta, H.D. (1995), "Damping effects of cable cross ties in cable-stayed bridges", J. Wind Eng. Indust. Aerodyn., 54-55, 35-43. https://doi.org/10.1016/0167-6105(94)00027-B   DOI
32 Zahrai, S.M. and Froozanfar, M. (2019), "Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge", Smart Struct. Syst., Int. J., 23(5), 449-466. https://doi.org/10.12989/sss.2019.23.5.449   DOI
33 Zhang, P., Song, G., Li, H.-N. and Lin, Y.-X. (2013), "Seismic Control of Power Transmission Tower Using Pounding TMD", J. Eng. Mech., 139(10), 1395-1406. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000576   DOI
34 Zhang, Z., Staino, A., Basu, B. and Nielsen, S.R.K. (2016), "Performance evaluation of full-scale tuned liquid dampers (TLDs) for vibration control of large wind turbines using real time hybrid testing", Eng. Struct., 126, 417-431. https://doi.org/10.1016/j.engstruct.2016.07.008   DOI
35 Mao, J.-X., Wang, H., Feng, D.-M., Tao, T.-Y. and Zheng, W.-Z. (2018), "Investigation of dynamic properties of long-span cable stayed bridges based on one-year monitoring data under normal operating condition", Struct. Control Health Monitor., 25(5), e2146. https://doi.org/10.1002/stc.2146   DOI
36 Shen, W., Niyitangamahoro, A., Feng, Z. and Zhu, H. (2019), "Tuned inerter dampers for civil structures subjected to earthquake ground motions: optimum design and seismic performance", Eng. Struct., 198, 109470. https://doi.org/10.1016/j.engstruct.2019.109470   DOI
37 Sorace, S. and Terenzi, G. (2012b), "The damped cable system for seismic protection of frame structures - Part II: Design and appli-cation", Earthq. Eng. Struct. Dyn., 41(5), 929-947. https://doi.org/10.1002/eqe.1165   DOI
38 Yu, J., Duan, Z., Zhang, X., Peng, J., Zhao, Y. (2021), "Wind-Induced Vibration Control of High-Rise Structures Using Compound Damping Cables", Shock Vib., 2021, 5537622. https://doi.org/10.1155/2021/5537622   DOI
39 Zhang, R., Zhao, Z. and Dai, K. (2019b), "Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system", Eng. Struct., 180, 29-39. https://doi.org/10.1016/j.engstruct.2018.11.020   DOI
40 Zuo, H., Bi, K. and Hao, H. (2017), "Using multiple tuned mass dampers to control offshore wind turbine vibrations under multi-ple hazards", Eng. Struct., 141, 303-315. https://doi.org/10.1016/j.engstruct.2017.03.006   DOI
41 Zhang, R., Ni, Y.-Q., Duan, Y. and Ko, J.-M. (2019a), "Development of a full-scale magnetorheological damper model for open-loop cable vibration control", Smart Struct. Syst., Int. J., 23(6), 553-564. https://doi.org/10.12989/sss.2019.23.6.553   DOI
42 Zhou, H., Yang, X., Sun, L. and Xing, F. (2015), "Free vibrations of a two-cable network with near-support dampers and a crosslink", Struct. Control Health Monitor., 22(9), 1173-1192. https://doi.org/10.1002/stc.1738   DOI
43 Zuo, L., Chen, X. and Nayfeh, S. (2011), "Design and Analysis of a New Type of Electromagnetic Damper with Increased Energy Density", J. Vib. Acoust., 133(4), 041006. https://doi.org/10.1115/1.4003407.   DOI
44 Huang, Z., Hua, X., Chen, Z. and Niu, H. (2019), "Performance evaluation of inerter-based damping devices for structural vibration control of stay cables", Smart Struct. Syst., Int. J., 23(6), 615-626. https://doi.org/10.12989/sss.2019.23.6.615   DOI
45 Lin, W., Song, G. and Chen, S. (2017), "PTMD Control on a Benchmark TV Tower under Earthquake and Wind Load Excitations", Appl. Sci.-Basel, 7(4), 425. https://doi.org/10.3390/app7040425   DOI
46 Pan, C. and Zhang, R. (2018), "Design of structure with inerter system based on stochastic response mitigation ratio", Struct. Control Health Monitor., 25(6), e2169. https://doi.org/10.1002/stc.2169   DOI
47 Zhang, Z., Nielsen, S.R.K., Basu, B. and Li, J. (2015), "Nonlinear modeling of tuned liquid dampers (TLDs) in rotating wind turbine blades for damping edgewise vibrations", J. Fluids Struct., 59, 252-269. https://doi.org/10.1016/j.jfluidstructs.2015.09.006   DOI
48 Aly, A.M., Zasso, A. and Resta, F. (2011), "On the dynamics of a very slender building under winds: response reduction using M R dampers with lever mechanism", Struct. Des. Tall Special Build., 20(5), 539-551. https://doi.org/10.1002/tal.647   DOI
49 Chen, Z.Q., Wang, X.Y., Ko, J.M., Ni, Y.Q., Spencer Jr, B.F., Yang, G. and Hu, J.H. (2004), "MR damping system for mitigating wind-rain induced vibration on Dongting Lake Cable-Stayed Bridge", Wind Struct., Int. J., 7(5), 293-304. https://doi.org/10.12989/was.2004.7.5.293   DOI
50 Ernst, J.H. (1965), "Der E-modul von seilen under berucksichtigung des durchhanges", Bauing, 40(2), 52-55.
51 Fan, S. (1989), "A new extracting formula and a new distinguishing means on the one variable cubic equation", J. Hainan Normal Univ. (Nat. Sci.), 2(2), 91-98.
52 Gao, H., Wang, H., Li, J., Wang, Z., Liang, R., Xu, Z. and Ni, Y. (2021), "Optimum design of viscous inerter damper targeting multi-mode vibration mitigation of stay cables", Eng. Struct., 226, 111375. https://doi.org/10.1016/j.engstruct.2020.111375   DOI