Compound damping cable system for vibration control of high-rise structures |
Yu, Jianda
(School of Civil Engineering, Hunan University of Science and Technology)
Feng, Zhouquan (College of Civil Engineering, Hunan University) Zhang, Xiangqi (School of Civil Engineering, Hunan University of Science and Technology) Sun, Hongxin (School of Civil Engineering, Hunan University of Science and Technology) Peng, Jian (School of Civil Engineering, Hunan University of Science and Technology) |
1 | Huang, Z.W., Hua, X.G., Chen, Z.Q. and Niu, H.W. (2018), "Modeling, Testing, and Validation of an Eddy Current Damper for Structural Vibration Control", J. Aerosp. Eng., 31(5), 04018063. https://doi.org/10.1061/(ASCE)AS.1943-5525.0000891 DOI |
2 | Ikago, K., Sugimura, Y., Saito, K. and Inoue, N. (2012b), "Modal Response Characteristics of a Multiple-Degree-Of-Freedom Structure Incorporated with Tuned Viscous Mass Dampers", J. Asian Architect. Build. Eng., 11(2), 375-382. https://doi.org/10.3130/jaabe.11.375 DOI |
3 | Ikago, K., Saito, K. and Inoue, N. (2012a), "Seismic control of single-degree-of-freedom structure using tuned viscous mass damper", Earthq. Eng. Struct. Dyn., 41(3), 453-474. https://doi.org/10.1002/eqe.1138 DOI |
4 | Shi, X., Zhu, S., Li, J.-Y. and Spencer Jr., B.F. (2016), "Dynamic behavior of stay cables with passive negative stiffness dampers", Smart Mater. Struct., 25(7), 075044. https://doi.org/10.1088/0964-1726/25/7/075044 DOI |
5 | Lazar, L.F., Neild, S.A. and Wagg, D.J. (2014), "Using an inerter-based device for structural vibration suppression", Earthq. Eng. Struct. Dyn., 43(8), 1129-1147. https://doi.org/10.1002/eqe.2390 DOI |
6 | Li, H., Liu, M., Li, J., Guan, X. and Ou, J. (2007), "Vibration Control of Stay Cables of the Shandong Binzhou Yellow River Highway Bridge Using Magnetorheological Fluid Dampers", J. Bridge Eng., 12(4), 401-409. https://doi.org/10.1061/(ASCE)1084-0702(2007)12:4(401) DOI |
7 | Liang, L., Feng, Z. and Chen, Z. (2019), "Seismic control of SDOF systems with nonlinear eddy current dampers", Appl. Sci., 9(16), 3427. https://doi.org/10.3390/app9163427 DOI |
8 | Lin, W.-H. and Chopra, A.K. (2002), "Earthquake response of elastic SDF systems with non-linear fluid viscous dampers", Earthq. Eng. Struct. Dyn., 31(9), 1623-1642. https://doi.org/10.1002/eqe.179 DOI |
9 | Liu, W., Guo, Y., Dong, X. and He, W. (2019), "Earthquake response control of a super high-rise structure subjected to long-period ground motions via a novel viscous damped system with multilever mechanism", Struct. Des. Tall Special Build., 28(7), e1600. https://doi.org/10.1002/tal.1600 DOI |
10 | Sun, H., Zuo, L., Wang, X., Peng, J. and Wang, W. (2019b), "Exact H 2 optimal solutions to inerter-based isolation systems for building structures", Struct. Control Health Monitor., 26(6), e2357. https://doi.org/10.1002/stc.2357 DOI |
11 | Wen, Y., Chen, Z. and Hua, X. (2017), "Design and Evaluation of Tuned Inerter-Based Dampers for the Seismic Control of MDOF Structures", J. Struct. Eng., 143(4), 04016207. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001680 DOI |
12 | Duan, Y., Ni, Y.-Q., Zhang, H., Spencer, B.F.J., Ko, J.-M. and Fang, Y. (2019), "Design formulas for vibration control of taut cables using passive MR dampers", Smart Struct. Syst., Int. J., 23(6), 521-536. https://doi.org/10.12989/sss.2019.23.6.521 DOI |
13 | Feng, Z.Q., Zhao, B., Hua, X.G. and Chen, Z.Q. (2019), "Enhanced EMD-RDT Method for Output-Only Ambient Modal Identification of Structures", J. Aerosp. Eng., 32(4), 04019046. https://doi.org/10.1061/(ASCE)AS.1943-5525.0001034 DOI |
14 | Kim, H.-K., Kim, K.-T., Lee, H. and Kim, S. (2013), "Performance of Unpretensioned Wind Stabilizing Cables in the Construction of a Cable-Stayed Bridge", J. Bridge Eng., 18(8), 722-734. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000405 DOI |
15 | Li, L., Song, G. and Ou, J. (2011), "Hybrid active mass damper (AMD) vibration suppression of nonlinear high-rise structure us-ing fuzzy logic control algorithm under earthquake excitations", Struct. Control Health Monitor., 18(6), 698-709. https://doi.org/10.1002/stc.402 DOI |
16 | Ni, Y.Q., Wang, J.Y. and Lo, L.C. (2005), "Influence of Stabilizing Cables on Seismic Response of a Multispan Cable Stayed Bridge", Comput.-Aided Civil Infrastruct. Eng., 20(2), 142-153. https://doi.org/10.1111/j.1467-8667.2005.00383.x DOI |
17 | Niu, H., Chen, Z., Hua, X. and Zhang, W. (2018), "Mitigation of wind-induced vibrations of bridge hangers using tuned mass dampers with eddy current damping", Smart Struct. Syst., Int. J., 22(6), 727-741. https://doi.org/10.12989/sss.2018.22.6.727 DOI |
18 | Pan, C., Zhang, R., Luo, H., Li, C. and Shen, H. (2018), "Demand-based optimal design of oscillator with parallel-layout viscous in-erter damper", Struct. Control Health Monitor., 25(1), e2051. https://doi.org/10.1002/stc.2051 DOI |
19 | Ahmad, J., Cheng, S. and Ghrib, F. (2018), "Combined effect of external damper and crosstie on the modal response of hybrid two-cable networks", J. Sound Vib., 417, 132-148. https://doi.org/10.1016/j.jsv.2017.12.023 DOI |
20 | Benavent-Climent, A. (2011), "An energy based method for seismic retrofit of existing frames using hysteretic dampers", Soil Dyn. Earthq. Eng., 31(10), 1385-1396. https://doi.org/10.1016/j.soildyn.2011.05.015 DOI |
21 | Caracoglia, L. and Jones, N.P. (2007), "Passive hybrid technique for the vibration mitigation of systems of interconnected stays", J. Sound Vib., 307(3-5), 849-864. https://doi.org/10.1016/j.jsv.2007.07.022 DOI |
22 | Roy, S., Park, Y.C., Sause, R. and Fisher, J.W. (2012), "Fatigue Performance of Stiffened Pole-to-Base Plate Socket Connections in High-Mast Structures", J. Struct. Eng., 138(10), 1203-1213. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000554 DOI |
23 | Lu, X., Zhang, Q., Weng, D., Zhou, Z., Wang, S., Mahin, S.A., Ding, S. and Qian, F. (2017), "Improving performance of a super tall building using a new eddy-current tuned mass damper", Struct. Control Health Monitor., 24(3), e1882. https://doi.org/10.1002/stc.1882 DOI |
24 | Sorace, S. and Terenzi, G. (2012a), "The damped cable system for seismic protection of frame structures - Part I: General concepts, testing and modeling", Earthq. Eng. Struct. Dyn., 41(5), 915-928. https://doi.org/10.1002/eqe.1166 DOI |
25 | Suarez, E., Roldan, A., Gallego, A. and Benavent-Climent, A. (2017), "Entropy analysis for damage quantification of hysteretic dampers used as seismic protection of buildings", Appl. Sci., 7(6), 628. https://doi.org/10.3390/app7060628 DOI |
26 | Sun, C., Jahangiri, V. and Sun, H. (2019a), "Performance of a 3D pendulum tuned mass damper in offshore wind turbines under multiple hazards and system variations", Smart Struct. Syst., Int. J., 24(1), 53-65. https://doi.org/10.12989/sss.2019.24.1.053 DOI |
27 | Choi, S.-W. and Kim, H.-K. (2008), "Design of aerodynamic stabilizing cables for a cable-stayed bridge during construction", Wind Struct., Int. J., 11(5), 391-411. https://doi.org/10.12989/was.2008.11.5.391 DOI |
28 | Yu, J., Tang, Y., Zhu, Y., Yu, P. and Wang, X. (2014), "A compound damping cable system", Chinese Invention Patent, CN104404886B. |
29 | Wang, Z., Gao, H., Xu, Y., Chen, Z. and Wang, H. (2019a), "Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations", Smart Struct. Syst., Int. J., 24(1), 83-94. https://doi.org/10.12989/sss.2019.24.1.083 DOI |
30 | Wang, Z.H., Xu, Y.W., Gao, H., Chen, Z.Q., Xu, K. and Zhao, S.B. (2019b), "Vibration control of a stay cable with a rotary electromagnetic inertial mass damper", Smart Struct. Syst., Int. J., 23(6), 627-639. https://doi.org/10.12989/sss.2019.23.6.627 DOI |
31 | Yamaguchi, H. and Nagahawatta, H.D. (1995), "Damping effects of cable cross ties in cable-stayed bridges", J. Wind Eng. Indust. Aerodyn., 54-55, 35-43. https://doi.org/10.1016/0167-6105(94)00027-B DOI |
32 | Zahrai, S.M. and Froozanfar, M. (2019), "Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge", Smart Struct. Syst., Int. J., 23(5), 449-466. https://doi.org/10.12989/sss.2019.23.5.449 DOI |
33 | Zhang, P., Song, G., Li, H.-N. and Lin, Y.-X. (2013), "Seismic Control of Power Transmission Tower Using Pounding TMD", J. Eng. Mech., 139(10), 1395-1406. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000576 DOI |
34 | Zhang, Z., Staino, A., Basu, B. and Nielsen, S.R.K. (2016), "Performance evaluation of full-scale tuned liquid dampers (TLDs) for vibration control of large wind turbines using real time hybrid testing", Eng. Struct., 126, 417-431. https://doi.org/10.1016/j.engstruct.2016.07.008 DOI |
35 | Mao, J.-X., Wang, H., Feng, D.-M., Tao, T.-Y. and Zheng, W.-Z. (2018), "Investigation of dynamic properties of long-span cable stayed bridges based on one-year monitoring data under normal operating condition", Struct. Control Health Monitor., 25(5), e2146. https://doi.org/10.1002/stc.2146 DOI |
36 | Shen, W., Niyitangamahoro, A., Feng, Z. and Zhu, H. (2019), "Tuned inerter dampers for civil structures subjected to earthquake ground motions: optimum design and seismic performance", Eng. Struct., 198, 109470. https://doi.org/10.1016/j.engstruct.2019.109470 DOI |
37 | Sorace, S. and Terenzi, G. (2012b), "The damped cable system for seismic protection of frame structures - Part II: Design and appli-cation", Earthq. Eng. Struct. Dyn., 41(5), 929-947. https://doi.org/10.1002/eqe.1165 DOI |
38 | Yu, J., Duan, Z., Zhang, X., Peng, J., Zhao, Y. (2021), "Wind-Induced Vibration Control of High-Rise Structures Using Compound Damping Cables", Shock Vib., 2021, 5537622. https://doi.org/10.1155/2021/5537622 DOI |
39 | Zhang, R., Zhao, Z. and Dai, K. (2019b), "Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system", Eng. Struct., 180, 29-39. https://doi.org/10.1016/j.engstruct.2018.11.020 DOI |
40 | Zuo, H., Bi, K. and Hao, H. (2017), "Using multiple tuned mass dampers to control offshore wind turbine vibrations under multi-ple hazards", Eng. Struct., 141, 303-315. https://doi.org/10.1016/j.engstruct.2017.03.006 DOI |
41 | Zhang, R., Ni, Y.-Q., Duan, Y. and Ko, J.-M. (2019a), "Development of a full-scale magnetorheological damper model for open-loop cable vibration control", Smart Struct. Syst., Int. J., 23(6), 553-564. https://doi.org/10.12989/sss.2019.23.6.553 DOI |
42 | Zhou, H., Yang, X., Sun, L. and Xing, F. (2015), "Free vibrations of a two-cable network with near-support dampers and a crosslink", Struct. Control Health Monitor., 22(9), 1173-1192. https://doi.org/10.1002/stc.1738 DOI |
43 | Zuo, L., Chen, X. and Nayfeh, S. (2011), "Design and Analysis of a New Type of Electromagnetic Damper with Increased Energy Density", J. Vib. Acoust., 133(4), 041006. https://doi.org/10.1115/1.4003407. DOI |
44 | Huang, Z., Hua, X., Chen, Z. and Niu, H. (2019), "Performance evaluation of inerter-based damping devices for structural vibration control of stay cables", Smart Struct. Syst., Int. J., 23(6), 615-626. https://doi.org/10.12989/sss.2019.23.6.615 DOI |
45 | Lin, W., Song, G. and Chen, S. (2017), "PTMD Control on a Benchmark TV Tower under Earthquake and Wind Load Excitations", Appl. Sci.-Basel, 7(4), 425. https://doi.org/10.3390/app7040425 DOI |
46 | Pan, C. and Zhang, R. (2018), "Design of structure with inerter system based on stochastic response mitigation ratio", Struct. Control Health Monitor., 25(6), e2169. https://doi.org/10.1002/stc.2169 DOI |
47 | Zhang, Z., Nielsen, S.R.K., Basu, B. and Li, J. (2015), "Nonlinear modeling of tuned liquid dampers (TLDs) in rotating wind turbine blades for damping edgewise vibrations", J. Fluids Struct., 59, 252-269. https://doi.org/10.1016/j.jfluidstructs.2015.09.006 DOI |
48 | Aly, A.M., Zasso, A. and Resta, F. (2011), "On the dynamics of a very slender building under winds: response reduction using M R dampers with lever mechanism", Struct. Des. Tall Special Build., 20(5), 539-551. https://doi.org/10.1002/tal.647 DOI |
49 | Chen, Z.Q., Wang, X.Y., Ko, J.M., Ni, Y.Q., Spencer Jr, B.F., Yang, G. and Hu, J.H. (2004), "MR damping system for mitigating wind-rain induced vibration on Dongting Lake Cable-Stayed Bridge", Wind Struct., Int. J., 7(5), 293-304. https://doi.org/10.12989/was.2004.7.5.293 DOI |
50 | Ernst, J.H. (1965), "Der E-modul von seilen under berucksichtigung des durchhanges", Bauing, 40(2), 52-55. |
51 | Fan, S. (1989), "A new extracting formula and a new distinguishing means on the one variable cubic equation", J. Hainan Normal Univ. (Nat. Sci.), 2(2), 91-98. |
52 | Gao, H., Wang, H., Li, J., Wang, Z., Liang, R., Xu, Z. and Ni, Y. (2021), "Optimum design of viscous inerter damper targeting multi-mode vibration mitigation of stay cables", Eng. Struct., 226, 111375. https://doi.org/10.1016/j.engstruct.2020.111375 DOI |
![]() |