• Title/Summary/Keyword: Very Low Temperature

Search Result 1,918, Processing Time 0.034 seconds

Comparison of virulence by Acanthamoeba strains in a murine model of acquired immunodeficiency syndrome (면역결핍 마우스를 이용한 Acnnthamoeba 분리주별 병원성 평가)

  • Gong, Hyeon-Hui;Lee, Seong-Tae;Jeong, Dong-Il
    • Parasites, Hosts and Diseases
    • /
    • v.36 no.1
    • /
    • pp.23-32
    • /
    • 1998
  • The pathogenic potential of Acnnthamoebc strains was evaluated by experimental infection of murine AIDS (MAIDS) model. C57BL/6 mice were induced to immunocompromized state by intraperitoneal injection of LP-BM5 MuLV and revealed the typical splenomegalty and Iymphatic enlargement of axillar and inguinal regios on necropsy 4 weeks after viral infection. Although there was no significant difference in the mortality rate of MAIDS mouse according to the culture temperature, it was very different in the mortality rate from strain to strain of Accnthnmoebc. A. henIHi OC-3A strain isolated from the brain of a GAE patient showed !he highest mortality rate and A. culbertsoni A-1 strain from tissue culture was the second. KA/S3 and KA/S2 strains isolated from soil revealed very low virulence. The mice infected by intranasal inoculation of Acanthnmoebc showed relatively chronic course than intravenous inoculation. The gross findings of lungs and brains from infected mice were variable among mice. On the microscopic observations, the lungs showed much more severe inflammation and necrosis than the brains microscopically. This MAIDS model would be useful to study the opportunistic protozoan infections of AIDS patients. In the light of these results. the pathogenic potential and the virulence of Acnnthamoebo may be determined genetically.

  • PDF

Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating (선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구)

  • Jang, Sung-Cheol
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.63-68
    • /
    • 2021
  • Domestic electric heater manufacturers are focusing on technology development to improve the efficiency of existing products. The electric heater for ship fuel is large in size and has high difficulty in miniaturization/high efficiency, so there are not many companies that try to develop technology yet. The existing electric heater has a structure of low heating efficiency because the contact time with the heat exchange tube of the heating medium is very short because the flow path of the ship engine fuel is monotonous. Since it is manufactured in a tubular shape, the volume is very large regardless of the heating efficiency. As a result, the tubular electric heater device applied by overseas advanced companies has difficulty in maintaining and repairing because it is necessary to decompose all tubular heaters when a specific part of the inside is damaged and if the heat exchange tube is damaged, all the heat exchange tubes must be decomposed. In this study, a basic study on plate type electric heaters capable of heating 10 tons of ship engine fuel per hour and setting a maximum temperature of up to 150℃ was conducted through a 250kW capacity plate type electric heater.

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.

Embryonic Development and Metamorphosis of the Ascidian Halocynthia aurantium (붉은멍게(Halocynthia aurantium)의 배발생과 변태)

  • Kim, Gil Jung
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.58-63
    • /
    • 2020
  • The ascidian Halocynthia aurantium (sea peach), which belongs to the phylum Chordata, is thought to be a valuable organism of aquaculture like H. roretzi (sea pineapple), but its biological characteristics such as development and ecology are not well known. In this study, in order to obtain basic data for H. aurantium farming, the development processes of H. aurantium inhabiting the east coast of Gangwon-do were investigated and compared with those of H. roretzi, a related species. As a result, the morphology and developmental stages of the fertilized eggs, embryos and larvae of H. aurantium were very similar to those of H. roretzi. Fertilized eggs of H. aurantium took about 42.1 hours to hatch at 11℃, almost similar to 40.9 hours of H. roretzi. The time required for larvae to metamorphose into juveniles after hatching was very similar between the two species. The hatched larvae of the two species became juveniles with oral and atrial siphons after 23 days at 11℃. Both types of embryos developed slowly in seawater at low temperatures and rapidly developed at high temperatures. Fertilized eggs of H. aurantium hatched in an average of 62.3 hours at 9℃, 42.1 hours at 11℃, and 36.3 hours at 13℃, whereas those of H. roretzi hatched in an average of 60.4 hours, 40.9 hours, and 35.2 hours. Most of H. aurantium embryos did not develop normally above 15℃, so it is thought that attention is needed in the seed production processes.

The Characteristics on the Spatio-temporal Distributions of Phytoplankton Communities in Deukryang Bay, Southwestern Korea (득량만 식물플랑크톤 군집의 시.공간적 분포특성.)

  • 윤양호
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.4
    • /
    • pp.481-492
    • /
    • 1999
  • The observations on the spatio-temporal distribution and seasonal fluctuations of phytoplankton community were carried out in Deukryang Bay of the Korean Southwestern Sea from June 1992 to April 1993. A total of 75 species of phytoplankton belonged to 47 genera was identified. In Deukryang Bay seasonal succession in dominant species; P. alata, G. flaccida, S. costatum, L. danicus and N. longissima in summer, St. palmeriana, Ch. curvisetus and B. paxillifera in autunm, S. costatum, Ch. curvisetus, E. zodiacus and Pn. pungens in winter, and As. glacialis, As. kariana, N. pelagica, Th. nitzschioides and S. costatum in spring, were very marked, that is to say, the communities structure of phytoplankton in Deukryang Bay appeared to be various species composition and it was occupied with diatoms all the year round. Phytoplankton standing crops fluctuated with an annual mean of $1.4{\times}10^5 cells/1 between the lowest value of 2.6{\times}10^3 cells/1 in July and the highest value of 1.0{\times}10^6 cells/1$ by S. costatum in January. Densities of the phytoplankton cell number by the samples of Deukryang Bay ranged from $2.6{\times}10^3cells/1 to 1.2{\times}10^5 cells/1 with the mean value of 3.6{\times}10^4cells/1 in summer, from 6.0{\times}10^3cells/1 to 2.6{\times}10^5 cells/1 with mean of 1.5{\times}10^5 cells/1 in autumn, from 1.3{\times}10^4cells/1 to 1.0{\times}10^6 cells/1 with mean 3.5{times}10^5 cells/1 in winter, and from 4.8{\times}10^3cells/1 to 6.0{\times}10^5 cells/1 with mean of 1.6{\times}10^5 cells/1$ in autumn. That is to say, phytoplankton standing crops was large in low temperature seasons, on the other hand small in high temperature seasons. Chlorophyll $\alpha$ concentration fluctuated between 0.l9 $\mu$g/l and 12.3 $\mu$g/l in March. in Deukryang Bay seasonal flucturation in chi-$\alpha$ concentration was not marked. Especially, chl-$\alpha$ concentration in the water around Deukryang Island located in the middle part of Deukryang Bay showed patchy distributions with a very high concentration. And chl-$\alpha$ concentration was high during a year. Therefore, phytoplankton production in Deukryang Bay could be very high year-round.

  • PDF

Preparation and Properties of Polyurethane Dispersions with Aromatic/Aliphatic Mixed Diisocyanate (방향족/지방족 혼합 Diisocyanate를 포함하는 Polyurethane 분산체의 제조와 성질)

  • Kim, Hyoung Sug;Noh, Si Tae
    • Applied Chemistry for Engineering
    • /
    • v.20 no.3
    • /
    • pp.258-265
    • /
    • 2009
  • An anionic polyurethane dispersions (PUDs) were synthesized from the poly (tetramethylene glycol) (PTMG, Mw = 2000 g/mol), mixed isocyanate of dicyclohexylmethane-4,4'-diisocyanate $(H_{12}-MDI)$ and 4,4'-diphenylmethane diisocyanate (MDI), and dimethylol propionic acid (DMPA) as anionic site, following a prepolymer mixing process. Triethylamine (TEA) was used as a neutralization agent and the ethylenediamine (EDA) as the chain extender of the prepolymer. The effects of the DMPA molar ratio and aromatic diisocyanate content in the mixed isocyanate on the particle size and viscosity of PUD were studied. Also, the mechanical and thermal properties of the PUD cast films were discussed according to the molar ratio of DMPA and aromatic isocyanate content. It was found that the particle size and the viscosity of an anionic PUD decreased with increasing DMPA molar ratio but increased with increasing aromatic isocyanate (MDI) content in the mixed isocyanate at the constant DMPA content. Tensile strength of the PUD cast films increased and elongation at break decreased with increasing DMPA content at the constant mixed isocyanate molar ratios. In thermal degradation temperature of PUD cast films, the effect of DMPA contents was great but the effect of aromatic isocyanate contents at the low DMPA content was very slight respectively.

An Experimental Study on the Combustion Characteristics of a Catalytic Combustor for an MCFC Power Generation System (MCFC 발전시스템용 촉매연소기의 연소 특성에 관한 실험적 연구)

  • Hong, Dong-Jin;Ahn, Kook-Young;Kim, Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.405-412
    • /
    • 2012
  • In the MCFC power generation system, the combustor supplies a high temperature mixture of gases to the cathode and heat to the reformer by using the off-gas from the anode; the off-gas includes high concentrations of $H_2O$ and $CO_2$. Since a combustor needs to be operated in a very lean condition and avoid local heating, a catalytic combustor is usually adopted. Catalytic combustion is also generally accepted as one of the environmentally preferred alternatives for generation of heat and power from fossil fuels because of its complete combustion and low emissions of pollutants such as CO, UHC, and $NO_x$. In this study, experiments were conducted on catalytic combustion behavior in the presence of Pd-based catalysts for the BOP (Balance Of Plant) of 5 kW MCFC (Molten Carbonate Fuel Cell) power generation systems. Extensive investigations were carried out on the catalyst performance with the gaseous $CH_4$ fuel by changing such various parameters as $H_2$ addition, inlet temperature, excess air ratio, space velocity, catalyst type, and start-up schedule of the pilot system adopted in the BOP.

A Design of Power Management IC for CCD Image Sensor (CCD 이미지 센서용 Power Management IC 설계)

  • Koo, Yong-Seo;Lee, Kang-Yoon;Ha, Jae-Hwan;Yang, Yil-Suk
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2009
  • The power management integrated circuit(PMIC) for CCD image sensor is presented in this study. A CCD image sensor is very sensitive against temperature. The temperature, that is heat, is generally generated by the PMIC with low efficiency. Since the generated heat influences performance of CCD image sensor, it should be minimized by using a PMIC which has a high efficiency. In order to develop the PMIC with high efficiency, the input stage is designed with synchronous type step down DC-DC converter. The operating range of the converter is from 5V to 15V and the converter is controlled using PWM method. The PWM control circuit consists of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit. The saw-tooth generator is designed with 1.2MHz oscillation frequency. The comparator is designed with the two stages OP Amp. And the error amplifier has 40dB DC gain and $77^{\circ}$ phase margin. The output of the step down converter is connected to input stage of the charge pump. The output of the charge pump is connected to input of the LDO which is the output stage of the PMIC. Finally, the PMIC, based on the PWM control circuit and the charge pump and the LDO, has output voltage of 15V, -7.5V, 3.3V and 5V. The PMIC is designed with a 0.35um process.

  • PDF

Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage (톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구)

  • Ko, Jae Sun;Kim, Joo-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • This study examined the risk of accidents when handling hazardous materials in hazardous materials storage facilities without safety facilities. In the case of illegal dangerous cargo containers, the burning rate is very fast in the case of fire, which leads to explosions, that are damaging and difficult to control. In addition, accidents that occur in flammable liquid hazardous materials are caused mostly by accidents that occur in the space due to leakage. Therefore, the variables that affect these accidents were derived and the influence of these variables was investigated. Numerical and computational fluid dynamics programs were used to obtain the following final results. First, when a flammable liquid leaks into a specific space, it is influenced by temperature and relative humidity until a certain concentration (lower limit of combustion) is reached. In the case of temperature, it was found that the reaching time was shorter than the flash point In addition, the effect of variables on pool fire accidents of leakage tanks is somewhat different, but the variables that have the largest influence are the wind speed. Therefore, it is expected that the results of this study will be used as basic data for similar numerical analysis and it will provide useful numerical information about the accidental leakage of hazardous materials under various research conditions.

Changes of Microbial Populations on Major Leafy Vegetables Cultivated by Different Methods from Production to Washing Stages (재배방법별 주요엽채류의 생산단계에서 세척단계까지 미생물상의 변화)

  • Oh, Soh-Young;Nam, Ki-Woong;Yoon, Deok-Hoon
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.38-43
    • /
    • 2018
  • A few authors have already investigated microbial contamination of leafy vegetables in distribution condition and examined the effect of temperature abuse on microbial safety or product quality. But this study analyzed proliferation of indicator microorganisms and food poisoning bacteria in real situation in Korean agroindustry and investigated washing effect of micobial contamination on leaf surface. Leafy vegetables were found to be contaminated with aerobic bacteria at $0.1{\sim}0.32{\times}10^3CFU/g$. Staphylococcus aureus and Bacillus cereus were detected in leafy vegetables at $0{\sim}0.54{\times}10^3CFU/g$. However, Salmonella spp., Coliforms, Clostridium spp. and Listeria spp. were not detected in any samples. Indicator microorganisms and food poisoning bacteria on leafy vegetables increased at room temperature when simulatively distributed condition. After clean-up, the indicator microorganisms and food poisoning bacteria of kimchi cabbage, lettuce and perilla leaf were decreased to a very low level. This study suggests that it is necessary to improve the level of hygiene management such as use of cold chain system and hygiene management of transport tools during the distribution process for fresh leafy vegetables.