• Title/Summary/Keyword: Vertical-irregular structure

Search Result 45, Processing Time 0.02 seconds

Seismic response of active or semi active control for irregular buildings based on eigenvalues modification

  • Pnevmatikos, Nikos G.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.647-664
    • /
    • 2014
  • A reduction of the response of irregular structures subjected to earthquake excitation by control devices equipped by suitable control algorithm is proposed in this paper. The control algorithm, which is used, is the pole placement one. A requirement of successful application of pole placement algorithm is a definition-selection of suitable poles (eigen-values) of controlled irregular structures. Based on these poles, the required action is calculated and applied to the irregular structure by means of control devices. The selection of poles of controlled irregular structure, is a critical issue for the success of the algorithm. The calculation of suitable poles of controlled irregular structure is proposed herein by the following procedure: a fictitious symmetrical structure is considered from the irregular structure, adding vertical elements, such as columns or shear walls, at any location where is necessary. Then, the eigen-values of symmetrical structure are calculated, and are forced to be the poles of irregular controlled structure. Based on these poles and additional damping, the new poles of the controlled irregular structure are calculated. By pole placement algorithm, the feedback matrix is obtained. Using this feedback matrix, control forces are calculated at any time during the earthquake, and are applied to the irregular structure by the control devices. This procedure results in making the controlled irregular structure to behave like a symmetrical one. This control strategy can be applied to one storey or to multi-storey irregular buildings. Furthermore, the numerical results were shown that with small amount of control force, a sufficient reduction of the response of irregular buildings is achieved.

A study on the effects of vertical mass irregularity on seismic performance of tunnel-form structural system

  • Mohsenian, Vahid;Nikkhoo, Ali
    • Advances in concrete construction
    • /
    • v.7 no.3
    • /
    • pp.131-141
    • /
    • 2019
  • Irregular distribution of mass in elevation is regarded as a structural irregularity by which the modes with high energy levels are excited and in addition, it can lead the structure to withstanding concentration of nonlinear deformations and consequently, suffer from unpredictable local or global damages. Accordingly, with respect to the lack of knowledge and insight towards the performance of concrete buildings making use of tunnel-form structural system in seismic events, it is of utmost significance to assess seismic vulnerability of such structures involved in vertical mass irregularity. To resolve such a crucial drawback, this papers aims to seismically assess vulnerability of RC tunnel-form buildings considering effects of irregular mass distribution. The results indicate that modal responses are not affected by building's height and patterns of mass distribution in elevation. Moreover, there was no considerable effect observed on the performance levels under DBE and MCE hazard scenarios within different patterns of irregular mass distribution. In conclusion, it appears that necessarily of vertical regularity for tunnel-form buildings, is somehow drastic and conservative at least for the buildings and irregularity patterns studied herein.

Ocean Engineering Basic Test for 5MW Offshore Wind Turbine Sub-structure Jack-up Platform (5MW급 해상풍력 Sub-structure Jack-up Platform 수조모형시험)

  • Jeon, Jung-Do;Jeon, Eon-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The safety and stability of 5MW class offshore wind turbine Jack-up platform was investigated through ocean basin experiment. For simulating the environmental condition of yellow sea in the South Korea, diverse waves, winds and currents were performed based on Froude's number. Regular wave and irregular wave based on Froude's number were applied to the wind turbine structure. In experiments, the height and period of regular wave type were scaled down as the 1:50 ratio of real wave condition. Irregular wave type was simulated with TMA(Texel Storm, Marsen and Arsloe)spectrum. The vertical reaction force, resonance period and wave pressure applied to multi-supporters of wind offshore structure were measured experimentally. Finally, the results showed that the capsizing situation of the offshore structure was generated by the severe environmental condition.

Hydraulic Experiments on Transmission Coefficients for Vertical Structure under Intermediate Water Depth Condition (중간수심역 조건에서 직립식 구조물의 전달파고계수 산정에 관한 수리실험)

  • Kim, Young-Taek;Lee, Jong-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 2015
  • Two-dimensional hydraulic model experiments on vertical structures were conducted to investigate wave transmission characteristics under irregular wave condition. The formula about transmission coefficient for the vertical structure was suggested and the results were compared with Goda(1969). Since Goda(1969)'s tests were conducted based on regular waves, the results showed the discrepancy with this study. The Goda's results were relatively higher than the results from the present study. An influence parameter was quantitatively suggested in this study to consider the effect of structural design factors such as the width of structures, the water depth, and the wave length on the wave transmission, while Goda(1969) suggested the mean, upper and lower limits of parameters for the vertical wall(d=h). The transmission coefficients and energy conservation for zero-freeboard conditions were analyzed.

Evaluation of Maximum Lateral Pressure on the 3D Printed Irregular-Shaped Formwork by Finite Element Analysis (3D 프린터로 제작된 비정형 거푸집의 최대 측압에 대한 유한요소해석)

  • Lee, Jeong-Ho;Ju, Young K.;Kim, Hak-Beom
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.167-174
    • /
    • 2017
  • The F3D(Free-Form Formwork 3D Printer) technology that manufactures EPS(Expanded Polystyrene) formworks for irregular-shaped concrete structures by 3D printers was developed to reduce the cost and time. Because of weak strength and low elastic modulus of the EPS, structural performance including lateral pressure by fresh concrete of the formwork that consisted of EPS should be investigated. In order to calculate lateral pressures acting on formwork, several variables including sizes, shapes of formwork, tangential force(fricition) between fresh concrete and formwork, and material properties of fresh concrete should be considered. However, current regulations have not considered the properties of concrete, only focused on vertical formwork. Galleo introduced 3-dimensional finite element analysis models to calculate lateral pressure on formwork. Thus, proposed finite element analysis model based on previous studies were verified for vertical formwork and irregular-shaped formwork. The test results were compared with those by FEM analysis. As a result, the test agrees well with the analysis.

Response of non-structural components mounted on irregular RC buildings: comparison between FE and EC8 predictions

  • Aldeka, Ayad B.;Chan, Andrew H.C.;Dirar, Samir
    • Earthquakes and Structures
    • /
    • v.6 no.4
    • /
    • pp.351-373
    • /
    • 2014
  • This paper investigates the seismic response of lightweight acceleration-sensitive non-structural components (NSCs) mounted on irregular reinforced concrete (RC) primary structures (P-structures) using non-linear dynamic finite element (FE) analysis. The aim of this paper is to study the influence of NSC to P-structure vibration period ratio, peak ground acceleration, NSC to P-structure height ratio, and P-structure torsional behaviour on the seismic response of the NSCs. Representative constitutive models were used to simulate the behaviour of the RC P-structures. The NSCs were modelled as vertical cantilevers fixed at their bases with masses on the free ends and varying lengths so as to match the frequencies of the P-structures. Full dynamic interaction is considered between the NSCs and P-structures. A set of 21 natural and artificial earthquake records were used to evaluate the seismic response of the NSCs. The numerical results indicate that the behaviour of the NSCs is significantly influenced by the investigated parameters. Comparison between the FE results and Eurocode (EC8) predictions suggests that EC8 underestimates the response of NSCs mounted on the flexible sides of irregular RC P-structures when the fundamental periods and heights of the NSCs match those of the P-structures. The perceived cause of this discrepancy is that EC8 does not take into account the amplification in the dynamic response of NSCs induced by the torsional behaviour of RC P-structures.

Seismic vulnerability assessment of low-rise irregular reinforced concrete structures using cumulative damage index

  • Shojaei, Fahimeh;Behnam, Behrouz
    • Advances in concrete construction
    • /
    • v.5 no.4
    • /
    • pp.407-422
    • /
    • 2017
  • Evaluating seismic performance of urban structures for future earthquakes is one of the key prerequisites of rehabilitation programs. Irregular structures, as a specific case, are more susceptible to sustain earthquake damage than regular structures. The study here is to identify damage states of vertically irregular structures using the well-recognized Park-Ang damage index. For doing this, a regular 3-story reinforced concrete (RC) structure is first designed based on ACI-318 code, and a peak ground acceleration (PGA) of 0.3 g. Some known vertical irregularities such as setback, short column and soft story are then applied to the regular structure. All the four structures are subjected to seven different earthquakes accelerations and different amplitudes which are then analyzed using nonlinear dynamic procedure. The damage indices of the structures are then accounted for using the pointed out damage index. The results show that the structure with soft story irregularity sustains more damage in all the earthquake records than the other structures. The least damage belongs the regular structure showing that different earthquake with different accelerations and amplitudes have no significant effect on the regular structures.

Study on Motion and Mooring Characteristics of Floating Vertical Axis Wind Turbine System (부유식 수직축 풍력발전 시스템의 운동특성 및 계류특성에 대한 연구)

  • Jang, Min-Suk;Jo, Hyo-Jae;Hwang, Jae-Hyuk;Kim, Jae-Heui;Kim, Hyen-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.202-207
    • /
    • 2017
  • This paper presents the results of an experimental study on the motions and mooring characteristics of a floating vertical axis wind turbine system. Based on a comparison of regular wave experiment results, the motions of structures with different types of mooring are almost the same. Based on the tension response results of a regular wave experiment with a catenary mooring system, the mooring lines in front of the structure have a larger tension effect than the back of the structure by the drifted offset of the structure. The dynamic response spectrum of the structure in the irregular wave experiments showed no significant differences in response to differences in the mooring system. As a result of the comparison of the tension response spectra, the mooring lines have a larger value with a drifted offset for the structure, as shown in the previous regular wave experiment. The results of the dynamic response of the structure under irregular wave and wind conditions showed that the heave motion response is influenced by the coupled effect with the mooring lines of the surge and pitch motion due to the drifted offset and steady heeling. In addition, the mooring lines in front of the structure have a very large tension force compared to the mooring lines in back of the structure as a result of the drifted offset of the structure.

Seismic Capacity Evaluation of the Structures with Vertical Irregularities (수직적 비정형성을 지니는 구조물의 내진성능평가)

  • 홍성걸;김남희;하태휴
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.208-215
    • /
    • 2001
  • The vertical irregularities occurred in the structure may lessen the overall seismic capacity of the structure. Seismic capacity evaluation guidelines (e.g. FEMA 175, ATC-14) propose the criterion for the vertical irregularities of mass, stiffness and strength respectively. But, the criterion seems groundless and leads us to make a true/false decision only. This study is to draw a reasonable basis on which multi-level grading is possible based fur the evaluation of existing buildings. Time history analysis for 3-,5-, and 10-story steel frame structures has been performed using several earthquake data. ANN (Artificial Neural Network) is introduced to find the relative contribution factor of the irregularities along the irregular position. Also, the application system fur the seismic capacity evaluation can be established using the trained ANN.

  • PDF

Analytical Research of Topside Installation in Mating phase with Crane Vessel

  • Lee, Jong-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.1-6
    • /
    • 2011
  • The installation of a topside structure can be categorized into the following stages: start, pre-lifting, lifting, lifted, rotating, positioning, lowering, mating, and end of installation. The transfer of the module onto the floating spar hull occurs in the last three stages, from lowering to the end. The coupled multi-body motions are calculated in both calm water and in irregular waves with a significant wave height (1.52m). The effects of the hydrodynamic interactions between the heavy lifting vessel and the spar hull during the lowering and mating stages are considered. The internal forces caused by the load transfer and ballasting are derived for the mating phases. The results of the internal forces for the calm water condition are compared with those in the irregular sea condition. Although the effect of the pitch motion on the relative vertical motion between the deck of the floating structure and the topside module is significant in the mating phases, the internal force induced pitch motion is too small to have this influence. However, the effect of the internal force on the wave-induced heave responses in the mating phases is noticeable in the irregular sea condition because transfer mass-induced draught changes for the floating structure are observed to have higher amplitudes than the external force induced responses. The impacts of the module on the spar hull in the mating phase are investigated.