• Title/Summary/Keyword: Vertical temperature difference

Search Result 261, Processing Time 0.024 seconds

Effects of Liquid Surface Tension on the Heat Transfer Coefficient in a Three-Phase Slurry Bubble Column (삼상슬러리 기포탑에서 액상의 표면장력이 열전달 계수에 미치는 영향)

  • Lim, Ho;Lim, Dae Ho;Jin, Hae-Ryong;Kang, Yong;Jung, Heon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.499-504
    • /
    • 2012
  • Characteristics of overall heat transfer were investigated in a three-phase slurry bubble column with relatively low surface tension media, which has been frequently encountered in the fields of industry. The heat transfer phenomena was examined in the system which was composed of a coaxial vertical heater and a proper of bubble column. The heat transfer coefficient was estimated from the measured mean value of temperature difference between the heater surface and the column proper at the steady state condition. Effects of gas velocity ($U_G$), solid fraction in the slurry phase ($C_S$) and surface tension (${\sigma}_L$) of continuous liquid media on the overall heat transfer coefficient (h) in the bubble column were determined. The mean value of temperature difference was estimated from the data of temperature difference fluctuations with a variation of time. The amplitude and mean value of temperature difference fluctuations with respect to the elasped time appeared to decrease with decreasing the surface tension of liquid phase. The overall heat transfer coefficient between the immersed heated and the bubble column increased with an increase in the gas velocity or solid fraction in the slurry phase, but it decreased with an increase in the surface tension of continuous liquid media. The overall heat coefficient in the slurry bubble column with relatively low surface tension media was well correlated in term of operating variables and dimensionless groups within this experimental conditions.

Evaluating Effect of Density Flow from Upstream on Vertical Distribution of Water Quality at the Paldang Reservoir (팔당호 수질의 연직분포에 대한 밀도류 영향 평가)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.557-566
    • /
    • 2019
  • Paldang is a river reservoir in the Midwest of Korea, which is a drinking water source for the metropolitan area. Since the Paldang Reservoir is shallow, and has a short hydraulic residence time, its water quality is directly impacted by two incoming rivers, the north Han River (NHR) and the south Han River (SHR). The NHR has different seasonal patterns of water temperature from the SHR because the NHR is greatly impacted by the discharge water from upstream dams. The electrical conductivity (EC) and other material concentrations of the SHR are usually higher than those of the NHR because its basin is limestone-based. The difference in water temperature in the two rivers causes density flow, and the distribution of the EC within the reservoir can be an indicator for monitoring density flow. From the vertical gradient of the EC at the dam site, from spring to fall, it was confirmed that the SHR flowed into the upper layer, and the NHR flowed into the lower layer, and vice versa at other times. The relative difference (RD) of the EC between the upper layer and the lower layer at the dam site was used as an indicator for density flow. The RD of the EC showed a very significant correlation with the RD of total organic carbon (r = 0.70, p < 0.001) and the RD of total nitrogen (r = 0.58, p < 0.01). This relationship is based on the assumption that the difference in electrical conductivity and water quality between the SHR and the NHR is constant. However, in many cases this assumption is inconsistent. Thus, further study is needed on more suitable indicators to evaluate the impact of density flow on water quality.

Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger (수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석)

  • Lee, B.C.;Kang, H.K.;Lee, M.S.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.

Vertical Distribution of Icthyoplankton in the Southern Waters of Jeju Island During Spring (봄철 제주 남부해역 난·자치어의 수직 분포)

  • Lee, Bo-Ram;Ji, Hwan-Sung;Yu, Hyo-Jae;Hwang, Kang-Seok;Kim, Doo-Nam
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.2
    • /
    • pp.146-153
    • /
    • 2022
  • The vertical distribution and abundance of icthyoplankton in the southern waters of Jeju Island during June 2020 were investigated. Fish eggs and larvae were identified using the mitochondrial DNA cytochrome c oxidase subunit I (mtDNA COI) and the 16S rRNA gene. During this period, fish eggs of 23 taxa belonging to 21 families and larvae of 27 taxa belonging to 25 families were collected. Fish eggs were located mostly from the surface to 30 m depth of the water column. Larvae were located from the surface to 80 m depth of the water column. Vertical distributions of fish eggs and larvae were influenced by oceanography conditions such as temperature, salinity, and thermocline depth. No discernible difference in mean thermocline depth was observed between day and night.

Experimental Investigation on the Thermal Performance of a Heat Spreader Module for the CPV Cooling (CPV 냉각용 열분산기 모듈의 열성능에 관한 실험적 연구)

  • Do, Kyu-Hyung;Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2011
  • In this paper, the thermal performance of a heat spreader module for CPV(Concentrating Photovoltaic) cooling is experimentally investigated. In order to evaluate the thermal performance of the heat spreader module which consists of a Metal PCB and an aluminum alloy heat spreader, experiments are conducted with varying the type of the metal PCB, the thickness of the heat spreader, the inclination angle, and the applied heat flux. To validate the experimental data, three dimensional numerical simulations are performed using the commercial simulation tool in the present work. The experimental results are compared with the corresponding numerical results and are in close agreement with the numerical results. From the experimental results, the temperature difference between the maximum temperature and the ambient temperature increases with decreasing the thickness of the heat spreader and with increasing the applied heat flux. Also, it is found that the inclination angle significantly affects the thermal performance of the heat spreader. the maximum temperature difference of the heat spreader with the horizontal orientation is much larger than that with the vertical orientation.

Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea (기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가)

  • 이승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy (복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Jung, Myoung-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.

A Study on Anion Generation according to Vertical Structures of Tree

  • Kim, Jeong-Ho;Oh, Deuk-Kyun;Seo, Yoo-Hwan;Park, Jae-Hyeon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1369-1379
    • /
    • 2016
  • This research assessed the disparity in anion generation according to the vertical structure of a Zelkova Serrata tree for the purpose of creating a pleasant and green city environment. Measurements for the study were conducted between July and August of 2014 in Chung-ju in the central region of the Republic of Korea. The average anion generation of vertical structure trees during active photosynthesis periods was: L Section ($839.0ea/cm^3$) > M Section ($664.6ea/cm^3$) > U Section ($472.0ea/cm^3$). According to DMRT analysis, significant difference was found in the average between the L, or M Locations and the U Locations. During dormant photosynthesis periods, records showed that the anion production at the M Location ($1,212.5ea/cm^3$) > L Location ($1,050.4ea/cm^3$) > H Location ($844.1ea/cm^3$), According to DMRT analysis, the difference within each location was significant for ${\alpha}=0.05$. In a comprehensive analysis of the weather factors in each vertical structure, anion generation during active photosynthesis periods showed a positive correlation with solar radiation and a negative correlation with wind speed. Dormant photosynthesis periods showed negative correlations with both solar radiation and temperature, and positive correlations with relative humidity and wind speed. Predictions from a multicenter retrospective study showed that during active photosynthesis periods, $Y_1=282.443X_1+512.07$, and $Y_2=314.337X_1+16.913X_2$, while during dormant photosynthesis periods, $Y_1=391.009X_1+840.043$, and $Y_2=351.412X_1+32.765X_2$.

The Characteristics of Seasonal Variations of Water Quality in Mokpo Harbour 1. Physical Environment and Organic Pollution (목포항 수질의 계절적 변화 특성 I. 물리 환경과 유기 오염)

  • 김광수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.5 no.2
    • /
    • pp.57-65
    • /
    • 1999
  • The in situ observations and the seawater analyses were conducted at all seasons from July 1996 to April 1999 for the purpose of describing the characteristics of seasonal variations of water quality in Mokpo harbour, Korea. Vertical stratification started to be formed in water column in spring, developed in summer and disappeared in fall. In summer, vertical density distribution of water column was found to be in stable structure with lower temperature and higher salinity of bottom water, and the vertical mixing of water between surface and bottom layers was restricted. In winter, however, surface water was found to be similar to bottom water in temperature and salinity, and water column was in unstable structure and in well-mixed condition between surface and bottom waters. The saturation percentage of dissolved oxygen(DO) in bottom water of inner part of Mokpo harbour at all seasons was shown to be decreased to the third grade or under the third grade of Korean standards of seawater quality. In particular, dissolved oxygen was oversaturated in surface water and undersaturated in bottom water in summer, due to stratification and organic pollution. The difference of DO concentration between surface and bottom waters was found to be greater in spring and summer than in fall and winter, due to stratification and photosynthesis of phytoplankton. The concentrations of chemical oxygen demand(COD) over the entire waters of Mokpo harbour were found to fluctuate from below the third grade to the first grade of Korean standards through all seasons and COD concentrations of same seasons were shown to be different year after year. In particular, in view of COD, the annual average seawater quality of Mokpo harbour was evaluated to be in third grade of Korean standards, due to organic pollution. The average COD of surface water was greater than that of bottom water in spring and summer, due to the autochthonous COD caused by production of phytoplankton in surface waters, while the average COD of surface water was similar to that of bottom water in fall and winter, due to the vertical mixing of water between surface and bottom layers.

  • PDF

Experimental and numerical investigation of closure time during artificial ground freezing with vertical flow

  • Jin, Hyunwoo;Go, Gyu-Hyun;Ryu, Byung Hyun;Lee, Jangguen
    • Geomechanics and Engineering
    • /
    • v.27 no.5
    • /
    • pp.433-445
    • /
    • 2021
  • Artificial ground freezing (AGF) is a commonly used geotechnical support technique that can be applied in any soil type and has low environmental impact. Experimental and numerical investigations have been conducted to optimize AGF for application in diverse scenarios. Precise simulation of groundwater flow is crucial to improving the reliability these investigations' results. Previous experimental research has mostly considered horizontal seepage flow, which does not allow accurate calculation of the groundwater flow velocity due to spatial variation of the piezometric head. This study adopted vertical seepage flow-which can maintain a constant cross-sectional area-to eliminate the limitations of using horizontal seepage flow. The closure time is a measure of the time taken for an impermeable layer to begin to form, this being the time for a frozen soil-ice wall to start forming adjacent to the freeze pipes; this is of great importance to applied AGF. This study reports verification of the reliability of our experimental apparatus and measurement system using only water, because temperature data could be measured while freezing was observed visually. Subsequent experimental AFG tests with saturated sandy soil were also performed. From the experimental results, a method of estimating closure time is proposed using the inflection point in the thermal conductivity difference between pore water and pore ice. It is expected that this estimation method will be highly applicable in the field. A further parametric study assessed factors influencing the closure time using a two-dimensional coupled thermo-hydraulic numerical analysis model that can simulate the AGF of saturated sandy soil considering groundwater flow. It shows that the closure time is affected by factors such as hydraulic gradient, unfrozen permeability, particle thermal conductivity, and freezing temperature. Among these factors, changes in the unfrozen permeability and particle thermal conductivity have less effect on the formation of frozen soil-ice walls when the freezing temperature is sufficiently low.