• Title/Summary/Keyword: Vertical temperature difference

Search Result 261, Processing Time 0.028 seconds

Thermodynamic Characteristics of Snowfall Clouds using Dropsonde Data During ICE-POP 2018 (ICE-POP 2018 기간 드롭존데 자료를 활용한 강설 구름의 열역학적 특성)

  • Jung, Sueng-Pil;Lee, Chulkyu;Kim, Ji-Hyoung;Yang, Hyo Jin;Yun, Jong Hwan;Ko, Hee Jong;Hong, Seong-Eun;Kim, Seung-Bum
    • Atmosphere
    • /
    • v.30 no.1
    • /
    • pp.31-46
    • /
    • 2020
  • The aircraft observation campaign was performed to investigate thermodynamic conditions of snowfall cloud over the East Sea of Korean peninsula from 2 February to 16 March 2018. During this period, four snowfall events occurred in the Yeongdong region and three cases were analyzed using dropsonde data. Snowfall cases were associated with the passage of southern low-pressure (maritime warm air mass) and expansion of northern high-pressure (continental polar air mass). Case 1 and Case 2a were related to low-pressure systems, and Case 2b and Case 3 were connected with high-pressure systems, respectively. And their thermodynamic properties and horizontal distribution of snowfall cloud were differed according to the influence of the synoptic condition. In Case 1 and Case 2a, atmospheric layers between sea surface and 350 hPa contained moisture more than 15 mm of TPW with multiple inversion layers detected by dropsonde data, while the vertical atmosphere of Case 2b and Case 3 were dry as TPW 5 mm or less with a single inversion inversion layer around 750~850 hPa. However, the vertical distributions of equivalent potential temperature (θe) were similar as moist-adiabatically neutral condition regardless of the case. But, their values below 900 hPa were about 10 K higher in Case 1 and Case 2a (285~290 K) than in Case 2b and Case 3 (275~280 K). The difference in these values is related to the characteristics of the incoming air mass and the location of the snowfall cloud.

Enhancement of light extraction efficiency in vertical light-emitting diodes with MgO nano-pyramids structure

  • Son, Jun-Ho;Yu, Hak-Ki;Lee, Jong-Lam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03a
    • /
    • pp.16-16
    • /
    • 2010
  • GaN-based light-emitting diodes (LEDs) are attracting great interest as candidates for next-generation solid-state lighting, because of their long lifetime, small size, high efficacy, and low energy consumption. However, for general illumination applications, the external quantum efficiency of LEDs, determined by the internal quantum efficiency (IQE) and the light extraction efficiency, must be further increased. The IQE is determined by crystal quality and epitaxial layer structure and high value of IQE more than 70% for blue LEDs have been already reported. However, there is much room for improvement of light extraction efficiency because most of the generated photons from active layer remain inside LEDs by total internal reflection at the interface of semiconductor with air due to the high refractive index difference between LEDs epilayer (for GaN, n=2.5) and air (n=1). The light confining in LEDs will be reabsorbed by the metal electrode or active layer, reducing the efficacy of LEDs. Here, we present the first demonstration of enhanced light extraction by forming a MgO nano-pyramids structure on the surface of vertical-LEDs. The MgO nano-pyramids structure was successfully fabricated at room temperature using conventional electron-beam evaporation without any additional process. The nano-sized pyramids of MgO are formed on the surface during growth due to anisotropic characteristics between (111) and (200) plane of MgO. The ZnO layer with quarter-wavelength in thickness is inserted between GaN and MgO layers to increase the critical angle for total internal reflection, because the refractive index of ZnO (n=1.94) could be matched between GaN (n=2.5) and MgO (n=1.73). The MgO nano-pyramids structure and ZnO refractive-index modulation layer enhanced the light extraction efficiency ofV-LEDs with by 49%, comparing with the V-LEDs with a flat n-GaN surface. The angular-dependent emission intensity shows the enhanced light extraction through the side walls of V-LEDs as well as through the top surface of the n-GaN, because of the increase in critical angle for total internal reflection as well as light scattering at the MgO nano-pyramids surface.

  • PDF

Effects of Natural Bioactive Products on the Growth and Ginsenoside Contents of Panax ginseng Cultured in an Aeroponic System

  • Kim, Geum-Soog;Lee, Seung-Eun;Noh, Hyung-Jun;Kwon, Hyuck;Lee, Sung-Woo;Kim, Seung-Yu;Kim, Yong-Bum
    • Journal of Ginseng Research
    • /
    • v.36 no.4
    • /
    • pp.430-441
    • /
    • 2012
  • This study was conducted to evaluate the effects of natural bioactive products such as Manda enzyme (T1), Yangmyeongwon (T2), effective microorganisms (T3), and Kelpak (T4) on the growth and ginsenoside contents of Panax ginseng cultured in an aeroponic system using a two-layer vertical type of nutrient bath under natural light conditions. The growth of ginseng plants showed specific characteristics according to the positions in which they were cultured due to the difference of light transmittance and temperature in the upper and lower layers during aeroponic culture in a two-layer vertical type of system. The growth of the aerial part of the leaves and stems of ginseng plants cultured in the lower layer (4,000 to 6,000 lx, $23^{\circ}C$ to $26^{\circ}C$) of the nutrient bath was observed to be superior to that of the ginseng plants cultured in the upper layer (12,000 to 15,000 lx, $25^{\circ}C$ to $28^{\circ}C$). The leaf area was significantly larger in the treatment of T2 and T4 (46.70 $cm^2$) than with other treatments. Conversely, the values of the root weight and root diameter were higher in ginseng plants cultured in the upper layer of the nutrient bath. The root weight was significantly heavier in the treatment of T4 (6.46 g) and T3 (6.26 g) than with other treatments. The total ginsenoside content in the leaves and roots was highest in the ginseng plants cultured by the treatment of T1, at 16.20%, while the total ginsenoside content obtained by other treatments decreased in the order of T4, T5 (control), T2, and T3, at 13.21%, 12.30%, 14.84%, and 14.86%, respectively. The total ginsenoside content of the ginseng leaves was found to be significantly higher in the treatment of T1 in the lower layer of the nutrient bath, at 15.30%, while the content of the ginseng roots in the treatments of T3 and T4, at 1.27% and 1.23%, respectively, was significantly higher than in other treatments in the upper layer of the nutrient bath.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.

An Experimental Study on the Thermal Performance of Air Filled Thermal Diode (공기를 작동 유체로 하는 열다이오드의 열성능에 관한 실험적 연구)

  • Pak, Ee-Tong;Jang, Young-Geun;Hwang, In-Ju
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 1997
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid, and blocks heat flow in the opposite direction. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient and steady state of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. $Gr^*$ was kept constantly on $1.11{\times}10^{10}{\sim}1.4{\times}10^{10}$ and error range was ${\pm}3%$ during the experiment. Nu was examined when inclined angle are $15^{\cir\c}\;and\;45^{\circ}$ and, also the experiments was carried out with and without guide vane as well. Specially, Nu was linearly increased due to increase of $Gr^*$, and the effect of guide vane and dimensionless channel depth was sensitive. Developed state of temperature began at dimensionless time $0.5{\sim}0.6$ due to variation of inclined angle, which is characteristic of system.

  • PDF

Observations of the Cheju Current

  • Suk, Moon-Sik;Pang, Ig-Chan;Teague, William J.;Chang, Kyung-Il
    • Journal of the korean society of oceanography
    • /
    • v.35 no.3
    • /
    • pp.129-152
    • /
    • 2000
  • The Cheju Current (CC), defined here as a mean eastward flow in the Cheju Strait, mostly carries water of high temperature and salinity originating from the Kuroshio in winter and spring, the Cheju Warm Current Water (CWCW). The strong core of the eastward component of the CC is found close to Cheju Island (Cheju-Do, hereafter) in winter and spring with a peak speed of about 17.0 cm/s. The eastward flow weakens towards the northern Cheju Strait, and a weak westward flow occurs occasionally close to the southern coast of Korea. The volume transport ranges from 0.37 to 0.45 Sv(1 Sv=10$^6$ m$^3$/s) in winter and spring. Seasonal thermocline and harocline are formed in summer and eroded in November. The occurrence of the CWCW is confined in the southern Cheju Strait close to Cheju-Do below the seasonal thermocline in summer and fall, and cold water occupies the lower layer north of the CWCW which is thought to be brought into the area from the area west of Cheju-Do along with the CWCW. Stratification acts to increase both the speed of the CC with a peak speed of greater than 30 cm/s and the vertical shear of the along-strait currents. The strong core of the CC detached from the coast of Cheju-Do and shifted to the north during the stratified seasons. The volume transport in summer and fall ranges 0.510.66 Sv, which is about 1.5 times larger than that in winter and spring. An annual cycle of the cross-strait sea level difference shows its maximum in summer and fall and minimum in winter and spring, whose tendency is consistent with the annual variability of the CC and its transport estimated from the ADCP measurements. Moored current measurements west of Cheju-Do indicate the clockwise turning of the CC, and the moored current measurements in the Cheju Strait for 1530 days show the low-frequency variability of the along-strait flow with a period of about 37 days.

  • PDF

Some Ecological Aspects of Antarctic Krill, Euphausia superba in the Antarctic Ocean (남빙양 새우의 생태학적 특성)

  • LEE Jang-Uk;KWON Jung-No;KIM Tae-Ik;YANG Weon-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.183-192
    • /
    • 1994
  • Spatial distribution patterns of Antarctic krill, Euphausia superba in the Atlantic Ocean sector were seasonally divided into three or four regions; South George Island, Laurie/Coronation Islands and Livingston/King George Islands. Antarctic krill were caught from the surface to about 150 m in depth. The vertical distribution of catch per hour (CPUE) did not show much differences between the 10 m layers, but there were gradually poorer CPUEs as trawl depth increased. It was estimated from relationship between water temperature and CPUE that the Antarctic krill abundance was maximal at water temperatures of $0.8{\sim}1.0^{\circ}C$. The length compositions of Antarctic krill showed that female fish were, on an average, significantly larger than males. Relationship between carapace length and body length, and body length-body weight relationship were well fitted. Sex ratio was $60.3\%$ for male and $39.7\%$ for female with significant difference at the $5\%$ level.

  • PDF

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

Metal Gate Electrode in SiC MOSFET (SiC MOSFET 소자에서 금속 게이트 전극의 이용)

  • Bahng, W.;Song, G.H.;Kim, N.K.;Kim, S.C.;Seo, K.S.;Kim, H.W.;Kim, E.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.358-361
    • /
    • 2002
  • Self-aligned MOSFETS using a polysilicon gate are widely fabricated in silicon technology. The polysilicon layer acts as a mask for the source and drain implants and does as gate electrode in the final product. However, the usage of polysilicon gate as a self-aligned mask is restricted in fabricating SiC MOSFETS since the following processes such as dopant activation, ohmic contacts are done at the very high temperature to attack the stability of the polysilicon layer. A metal instead of polysilicon can be used as a gate material and even can be used for ohmic contact to source region of SiC MOSFETS, which may reduce the number of the fabrication processes. Co-formation process of metal-source/drain ohmic contact and gate has been examined in the 4H-SiC based vertical power MOSFET At low bias region (<20V), increment of leakage current after RTA was detected. However, the amount of leakage current increment was less than a few tens of ph. The interface trap densities calculated from high-low frequency C-V curves do not show any difference between w/ RTA and w/o RTA. From the C-V characteristic curves, equivalent oxide thickness was calculated. The calculated thickness was 55 and 62nm for w/o RTA and w/ RTA, respectively. During the annealing, oxidation and silicidation of Ni can be occurred. Even though refractory nature of Ni, 950$^{\circ}C$ is high enough to oxidize it. Ni reacts with silicon and oxygen from SiO$_2$ 1ayer and form Ni-silicide and Ni-oxide, respectively. These extra layers result in the change of capacitance of whole oxide layer and the leakage current

  • PDF

Heat Transfer in Radiatively Participating Gas-Particle Cavity Flows (輻射가 關與하는 氣體-固體粒子 캐비티 流動에서의 熱傳達)

  • 이종욱;이준식;이택식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.551-560
    • /
    • 1988
  • Gas-particle two phase flow and heat transfer in a cavity receiving thermal radiation through selectively transparent walls have been analyzed by a finite difference method. Particles injected from the upper hole of the cavity are accelerated downward by gravity and exit through the lower hole while they absorb, emit and scatter the incident thermal radiation. Gas phase is heated through convection heat transfer from particles, and consequently buoyancy induced flow field is formed. Two-equation model with two-way coupling is adopted and interaction terms are treated as sources by PSI-Cell method. For the particulate phase, Lagrangian method is employed to describe velocities and temperatures of particles. As thermal radiation is incident upon horizontally, radiative heat transfer in the vertical direction is assumed negligible and two-flux model is used for the solution of radiative heat flus. Gas phase velocity and temperature distributions, and particle trajectories, velocities and temperatures are presented. The effects of particle inlet condition, particle size, injection velocity and particle mass rate are mainly investigated.