• Title/Summary/Keyword: Vertical spread

Search Result 133, Processing Time 0.029 seconds

A Study on the Use of Balcony Areas to Improve Fire Escape for Residents in Apartments (화재피난 방안 수립을 위한 공동주택 거주자의 발코니 사용실태 조사)

  • Lee, So-Young;Lee, Myung-Sik
    • Korean Journal of Human Ecology
    • /
    • v.17 no.3
    • /
    • pp.541-552
    • /
    • 2008
  • With the increase of apartments and expansion of balcony areas, fire safety issues are becoming more important. Many researchers have conducted a lot of researches to reduce vertical flame spread in the balcony when an apartment unit is in fire. However, there have rarely been studies to use balcony area as a space for fire escape and evacuation. The study aims to examine the conditions of balcony use in apartments in order to find out prevention elements from fire escape and evacuation, and to investigate residents' satisfaction with balcony. For this study, questionnaires were collected from apartment residents and workers of architectural planning and construction companies. The findings show as follows: first, the balcony is generally used as a storage in each apartment unit nowadays. Second, when fire breaks out, many storage items could disturb residents' safe escape by blocking escape route, and easily promote to spread flame vertically in the balcony.

A Study on Block from Spread of Fire of the Exteriors Installation Space (외장재 설치 공간의 화재확산 차단에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.83-89
    • /
    • 2012
  • In this study, FDS fire simulation experiments and measured wind speed by applying the exterior installation portion for blocking the spread of the fire was investigated. As a result, aluminum composite panels installed in the lower and the upper part of the panel to remove all the lower side, and then the maximum wind speed 0.24 m/s and the upper side 0.58 m/s were measured. In the FDS, the measured wind speed difference air currents are approximately 3.7 times in 12 seconds, the occurrence of 17 seconds early moment wind 2.2 m/s was measured from. Before and after the fire occurred in early of the air velocity about 39 seconds was 3.5 times difference. Such air currents caused by the temperature of the building but also by the building height was found. Turbulent flame of fire by expanding the vertical extent of damage become greatly important factor. Therefore, through the exterior installation portion of the block that can delay the spread of fire is expected that this should be taken.

A Model for Slab Width Spread during Hot Rough Rolling Using a Profiled Edger Roll (형상 엣저 롤을 이용한 열간 조압연 공정의 슬래브 폭 퍼짐 예측 모델)

  • Lee, K.H.;Han, J.G.;Yoo, K.H.;Kim, H.J.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.25 no.2
    • /
    • pp.102-108
    • /
    • 2016
  • The aim of the current study was to develop an advanced prediction model for the slab width spread during hot rough rolling. Rough rolling consists of both vertical rolling using a set of profiled edger rolls and horizontal rolling using a set of plain work rolls. FE-simulations were performed to investigate the influences of process variables such as initial slab width, initial thickness, sizing draft, edger roll draft and work roll draft on the final slab width variation. From a statistical analysis of the simulation results, an advanced model, which can predict the slab width spread during the edger rolling and horizontal rolling, was developed. The experimental hot rolling trials showed that the newly developed model provided fairly accurate predictions on the slab width spread during hot rough rolling process using a profiled edger rolls.

Calculation of Fire-resisting Time and Extraction of Simple Transplants in the Event of a Building Fire (건축물 화재시 필요내화 시간 산정 및 간이식 도출)

  • Kim, Yun-Seong;Han, Ji-Woo;kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.59-60
    • /
    • 2020
  • Large fires continue to spread throughout the building, including the fire in Uijeongbu in 2015, the fire in Jecheon in 2017, and the fire in Miryang in 2018. According to the above fire case investigation, major problems were the fire resistance performance of compartment members such as fire doors, the fire spread due to damage to exterior wall openings, and smoke spread through vertical openings. However, in South Korea, only specification design is implemented for buildings that are not subject to performance design. In addition, the analysis of the fire resistance performance standards of building members in the specification design showed that fire doors were not specified in detail for 60 minutes of insulation performance and 60 minutes of fire resistance performance of E/V doors, limiting the prevention of fire spread. Therefore, the purpose of this research is to prepare measures to prevent the spread of fire by presenting simple transplants for calculating the required fire time according to the architectural design conditions for the performance design of the components of the fire room according to the purpose of use of the front of the building.

  • PDF

A Study on the Fire Reconstruction of Exterior on High-rise Building (Focus on Fire Case Including the Woosin Golden Suite in Haeundae) (고층 건축물 외장재의 화재 재현에 관한 연구 (해운대 우신골든스위트의 화재사례를 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • 'Heaundae Woosin Building' fire was the case that a fire breaking out on the $4^{th}$ floor spread out the $38^{th}$ floor which is a top story and the penthouse was destroyed by fire. After this fire, the fire safety for high rise buildings has been on the rise and several new laws and regulations related in the buildings were created. The study is to analyze Heaundae officetel building case using FDS which is one of the CFD programs for fire. The methodology of this study is to analyze the case comparing with fire spread and route from a virtual fire simulation and related articles and a video clip of actual scene fire. This study shows that a fire spreading on top of levels spent approximately 30 minutes and, which is similar to the actual fire case. Also the pattern of spread has similarity with the case. However, even if the actual fire case shows the fire pattern was "V shape", the smoke-view presents the fire dose not spread horizontally as much as the real fire case. The result shows uncertainty of the modeling based on many grids and a limitation of putting interior finish input sources and the direction of the wind might cause the difference. Also, to analyze factors influencing on a vertical fire, another fire modeling is performed by in condition of modeling environment considering concrete interior finish between buildings and no wind. The result presents the fire spread in smoke-view does not spread vertically as much as the actual case.

The Water Curtain Installation Guideline for Fire Spread Prevention in Market (재래시장의 화재확산 방지를 위한 수막설비 설치 지침)

  • Choi, Jung-Uk;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

Trial Construction for the Prevention of Fire Spread in Piloti Building (필로티건축물의 화재확산방지를 위한 시범시공)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

Analysis for Fire Spread through Double Skin Facade System with FDS (화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰)

  • Huh, Yoon-Taek;Park, Chang-Bok;Sung, June-Shik;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.110-116
    • /
    • 2009
  • This study is related with fire risk assessment for fire and smoke spread of double skin facade system by use of FDS (Fire Dynamics Simulator) which is a computational fluid dynamics (CFD) model of fire-driven fluid flow. For the study, fire scenario is intended to evaluate the impact of a fire spread for glazed office building. The major purpose of this study is to analyze the fire risk depending on the width of between inner skin and outer skin and to present fire prevention method regarding double skin facade system. The result of analysis presents fire spread more vertically as intermediate space becomes narrow. It is anticipated that fire can spread upper 2 stories above the fire floor if intermediate space with not more than 1m width. Therefore, prevention of vertical fire spread is required.

Plastic characteristic analysis of width reduction process in hot roughing mill (열간조압연 공정에서의 폭 압하 공정시 슬래브의 변형 특성)

  • Heo, Su-Jin;Lee, Sang-Ho;Byun, Sang-Min;Park, Hae-Do;Lee, Jong-Bin;Kim, Byung-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.544-548
    • /
    • 2007
  • In general, final width of hot strip should be accomplished in this stage because width reduction of strip hardly appears during typical finishing mill. However, it is difficult to control the width of strip in the roughing mill process as the horizontal rolling of strip is subsequently performed after the vertical rolling. It is therefore important to obtain the deformation rolling direction on strip width to minimize the width spread of strip during horizontal rolling after vertical rolling. Generally there is Sizing press type and Edger-roll type. The width reduction process in sizing press has small amount of width spread compared with the edger. However, productivity by the sizing press process is much lower than those of the edger. In this study, sizing press and Edger-roll process parameters in a sheet rolling mill were set at specified values and the effect of the change in these parameters on product quality and process performance were evaluated.

  • PDF