• Title/Summary/Keyword: Vertical progress

Search Result 126, Processing Time 0.023 seconds

The study for calculating the geometric average height of Deacon equation suitable to the domestic wind correction methodology. (국내풍속보정에 적합한 Deacon 방정식의 기하평균높이 산정방법에 대한 연구)

  • Cheang, Eui-Heang;Moon, Chae-Joo;Jeong, Moon-Seon;Jo, Kyu-Pan;Park, Gui-Yeol
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.9-14
    • /
    • 2010
  • The main cause of global warming is carbon dioxide generated from the use of fossil fuels, and active research on the reduction of carbon is in progress to slow down the increasing global warming. Wind turbines generate electricity from kinetic energy of wind and are considered as representative for an energy source that helps to reduce carbon emission. Since the kinetic energy of wind is proportional to the cube of the wind speed, the intensity of wind affects wind farm construction validity the most. Therefore, to organize a wind farm, validity analysis should be conducted first through measurement of the wind resources. To facilitate the approval and permission and reduce installation cost, measuring sensors should be installed at locations below the actual wind turbine hub. Wind conditions change in shape with air density, and air density is most affected by the variable sterrain and surface type. So the magnitude of wind speed depends on the ground altitude. If wind conditions are measured at a location below the wind turbine hub, the wind speed has to be extrapolated to the hub height. This correction of wind speed according to height is done with the Deacon equation used in the statistical analysis of previously observed data. In this study, the optimal Deacon equation parameter was obtained through the analysis of the correction of the wind speed error with the Deacon equation based on the characteristics of terrain.

Design of the Dual Receiving Channel T/R Module for the Next Generation SAR Payload (차세대 SAR 탑재체를 위한 이중 수신 채널 T/R 모듈 설계)

  • Won, Young-Jin;Youn, Young-Su;Woo, Sung-Hyun;Yoon, Jae-Cheol;Keum, Jung-Hoon;Kim, Jin-Hee
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.1-11
    • /
    • 2012
  • This paper describes the transmit/receive(T/R) module for the space based X-band active phased array radar. T/R module is the integrated module which is assembled by the transmitting and receiving RF semiconductor devices to enable the electronically beam steering of the phased array antenna and the key component of the SAR payload. T/R module can selectively receive the polarization signals by the switch according to the established technology but now the technological trend of the T/R module is to receive the horizontal and vertical polarization signal simultaneously. Therefore the research and development of the dual polarization receiving channel T/R module is actively in progress. In this study, as the prior research for the next generation SAR payload, the technological trend of the active phased array radar T/R module and the result of the preliminary design of the dual receiving channel T/R module were described.

Analysis on Mandibular Movement of Temporomandibular Disorder Patients using Mandibular Kinesiograph (Mandibular Kinesiograph를 이용한 측두하악장애환자의 하악운동 분석)

  • Woo-Cheon Kee;Byung Gook Kim;You-Kyung Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.185-194
    • /
    • 1995
  • The purpose of this study was to estimate primary diagnosis, prediction of prognosis and recognition fo treatment progress for treatment of TMD patients through measuring the various ranges of mandibular movement in normal and TMDs patients using Mandibular Kinesiograph K-6 Diagnostic system. In normal groups, 20 adults were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. In Patients group, we selected 31 outpatients who were confirmed to TMDs with clinical examination and radiographic findings. The obtained results were as follows : 1. In maximal opening, patient group was showed the limitation of vertical movement range (P<0.01) and lager lateral deviation than in normal group (P<0.05). And actual dimensional displacement of opening was calculated larger in normal group (P<0.05). 2. In protrusive movement, patients group was showed the limitation of anteroposterior movement range (P<0.001) and larger deviation than in normal group (P<0.01). And actual 3 dimensional displacement of protrusion was calculated larger in normal group (P<0.001). 3. In lateral maximum excursion, compared with normal group patient group was no significant differences to affected side, but was showed the limitation of lateral movement to unaffected side (P<0.001). 4. There was no significant difference in movement velocity of opening and closing in both groups. 5. Mandibular movement from physiologic rest position to centric occlusion was moved more anteroposteriorly in patient group. 6. Mandibular movement from centric relation to centric occlusion was no significant difference in both groups.

  • PDF

A study on the site analysis considering a fused relationship of the architectural site and surrounding context (건축대지와 주변 컨텍스트의 융합적인 연계성을 고려한 대지분석에 관한 연구)

  • Jun, In-Mok
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.275-285
    • /
    • 2017
  • The architectural site exists in the context of the surrounding environment as the background of architectural design, and the architecture exists in the connection between the site and the surrounding environment therefore, the plan of the building starts from the analysis of the site, and its consequences too meaning can be found in the relation with the surrounding environment. Ironically, however, there are no direct papers describing site analysis with this meaning. Therefore, this paper categorizes the site analysis items around the four environments of Land, Water, Fire, and Wind that constitute the environment of the ecosystem, furthermore, in order to apply the result of the fusion information to the architectural design by synthesizing the organic correlation between the inside and the surrounding environment, i created the '9sectors system', which is a combination of 'horizontal 3 and vertical 3' to provide a more rational and efficient architectural plan. Through the progress of the project using this system, it is considered that it is a more applicable method of the site analysis data than the existing site analysis method.

A Study on the Minimization of Spatial Error in 3-Demensional Neuronavigator (3차원 영상지원 뇌수술장비의 공간오차 최소화에 관한 연구)

  • 이동준;다영신;이정교
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.19-26
    • /
    • 1997
  • 3-dimensional Neuronavigator, Viewing Wand(ISG Technologies, Toronto, Cannda) is the surgery aid equipment for real time image (CT or MRI) guided surgery. The assurance of spatial accuracy of this system is important for clinical application. In this study, we have designed the acrylic brain phantom and measured the spatial error with that phantom. The phantom has designed to have capability to simulate image guided surgery. The phantom has 22 vertical rods whose diameters are 5mm and each rods has different length. CT scans were performed by 2.0mm slice and reconstructed for 3-Dimensional analysis. End point of rods can be obtained using reconstructed 3- Dimensional images and they are compared to actual position data. Average deviation was less than 2mm for various situations. Spatial error of Viewing Wand is acceptable in the clinical points of view, while cosmetics of the software needs to be modified to more user friend. Better accuracy can be expected when we apply the mixed fiducial fit registration and surface fit registration method. And even better results can be obtained if registration points distributed even and symetric around the target.

  • PDF

Evolution of Vertical Integration in the Korea Broiler Industry (한국육계산업의 수직통합(계열화) 전개상황)

  • 박영인
    • Korean Journal of Poultry Science
    • /
    • v.18 no.1
    • /
    • pp.57-66
    • /
    • 1991
  • The broiler industry in Korea has been gradually changing its structure of independent operation into integrated and coordinated production and marketing system. It was in 1960s when the broiler industry first tried the integrated effort, but never succeeded as it was expected since due mainly to growers' attitudes favorable for traditional operation and agribusiness' passive response on structure change. Until mid 1980s, however, a bit of partially integrated system had been evolved by several factor suppliers. Recent years have furthered its progress toward completely integrated pattern, the ultimate goal of broiler integration. It is true that the external factors including the GATT Negotiations through the Uruguay Round stimulated the people involved in the industry to find the way of making it competitive to survive in the open, liberalized world economic system rapidly emerging through the process of globalization. Once the industry realized the necessity of reducing the cost of production and improving the quality of it, the conclusion tended to come to the point of an entire structural alteration by means of integration rather than an improvement of a certain segment such as marketing. It is very obvious. therefore. that the movement toward the complete integration will speed up in a coming few years under the leadership of not only entrepreneurs but also producers group. According to a report. there were three almost complete integrators and thirteen partial integrators as of December, 1990, all of which eagerly directed toward the completely integrated system in due course . Among others as an advantage of integrated structure. the cost saving must be pointed out as the greatest one In a survey, it was estimated that the cost of dressed and ready-to-eat chicken could be lowered by 31.8 percent and 41.5 percent, respectively, over that to be under the independent, non-integrated system. As long as everybody concerned about the future of the industry in the open market mechanism realizes the importance of the structure change through an integration, the broiler sector of Korean agriculture shall be moving toward the direction of vertically and completely integrated structure in order to make it competitive, even to export, hopefully before 1995 or by the end of this century in any case.

  • PDF

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

An Experimental Study of Dynamic Type Ice Storage System Using Magneticfluid (자성유체를 이용한 다이나믹형 빙축열 시스템에 관한 실험적 연구)

  • Hwang, Seung-Sic
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1484-1493
    • /
    • 2004
  • In this study, it induced to a conclusion below by experiment consideration to regarding an effective supercooling ends method of the flow cooling water in a tube of continuous ice making method and the static cooling water in a tube of continuous ice making method which used magneticfluid in a dynamic type ice storage system. Continuous ice making in a tube of the flow cooling water was shortened about 12 minutes until supercooling ends that case which gave vertical eccentricity rotation magnetic field 120rpm than did not provide magnetic field by experimental result that was tested to supercooling ends effect from shape control of magneticfluid. Continuous ice making method in a tube of the static cooling water compared with and reviewed the case that was not provided with the magnetic field and exposed cooling surface instantaneously by magnetic field. It confirmed that supercooling degree $\Delta$ $T_{c}$, $\Delta$ $T_{s}$, and $\Delta$ $T_{w}$ became lower because of heat transfering increasing by the occurrence of natural convection between after cooling starting progress time 1∼3 minutes if it did not give a magnetic field, and peformed the supercooling ends when natural convection occurred confirmed that refrigerating capacity was better. That relation $\Delta$ $T_{c}$, and $t_{e}$/($\Delta$ $T_{c}$-$\Delta$ $T_{s}$) after convection occurred, was not depended on $T_{b}$ and initial temperature if the depth of water and thickness of magneticfluid were regular and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.lar and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.c}$.>.

Automatic Extraction of Building Height Using Aerial Imagery and 2D Digital Map (항공사진과 2차원 수치지형도를 이용한 건물 고도의 자동 추출)

  • Jin, Kyeong-Hyeok;Hong, Jae-Min;Yoo, Hwan-Hee;Yeu, Bock-Mo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.2 s.32
    • /
    • pp.65-69
    • /
    • 2005
  • Efficient 3D generation of cultural features, such as buildings in urban area is becoming increasingly important for a number of GIS applications. For reconstruction or 3D building in urban area aerial images, satellite images, LIDAR data have been used mainly. In case of automatically extracting and reconstructing of building height using single aerial images or single satellite images, there are a lot of problems, such as mismatching that result from a geometric distortion of optical images. Therefore, researches or integrating optical images and existing 2D GIS data(e.g. digital map) has been in progress. In this paper, we focused on extracting of building height by means or interest points and vortical line locus for reducing matching points. Also we used digital plotter in order to validate for the results in this study using aerial images(1/5,000) and existing digital map(1/1,000).

  • PDF

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF