• 제목/요약/키워드: Vertical plate

검색결과 770건 처리시간 0.028초

장방형 발열체가 부착된 채널에서 자연대류 연구 (Natural Cconvection in a Vertical Channel with Thermal Blocks)

  • 최용문;박경암
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.438-444
    • /
    • 1993
  • The circuit board of an electronic equipment were simulated with a vertical channel which had thermal blocks protruded from one of the channel walls. A rought front plate was made of a circuit board attached with short wires to simulate the back side of a printed circuit board. Natural convection experiments were carried out to study the effects of channel space and rough front plate and to find the suitable characteristic value after the fourth row. The effect of a rough front plate was negligble. There were negligible effects of the channel space on the first and second heaters. Heat transfer coefficients after the third row decreased as the channel space decreased. Heat transfer coefficients were almost constant for larger than 20 mm channel space. A characteristic length was suggested to non-dimensionalize Nu and Ra numbers in a vertical channel with protruded heaters. A correlation was obtained using the new characteristic lengths.

등온 수직 평판에서의 혼합대류 열전달 (Mixed convection from two isothermal, vertical, parallel plates)

  • 박문길;이재신;양성환;권순석
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1645-1651
    • /
    • 1990
  • 본 연구에서는 두 개의 수직 등온 평판이 평행하게 배열된 경우의 혼합대류 열전달에 대하여 무차원 평판 간격, b/l와 Grashof수, 레이놀즈수를 변수로 유한차분 법을 사용 수치해석하고, 두평판사잉의 간섭현상과 열전달을 최대로 하는 최적 평판간 격을 구하였다.

Numerical Study on Simultaneous Heat and Mass Transfer in a Falling Film of Water-Cooled Vertical Plate Absorber

  • Phan, Thanh-Tong;Song, Sung-Ho;Moon, Choon-Geun;Kim, Jae-Dol;Kim, Eun-Pil;Yoon, Jung-In
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.41-47
    • /
    • 2002
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber was developed. The model can predict temperature and concentration profiles as well as the absorption heat and mass fluxes, the total heat and mass transfer rates and the heat and mass transfer coefficients. Besides, the effect of operating condition on absorption mass flux has been investigated, with the result that the absorption mass flux is increased as the inlet cooling water temperature decreases, the system pressure increases and the inlet solution concentration increases. And among the effects of operating parameters on absorption mass flux, the effect of inlet solution concentration is dominant.

  • PDF

공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법 (Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber)

  • 정은수
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

보강상세 적용에 따른 강바닥판 피로강도 향상에 관한 해석적 연구 (Analytical Study on the Improvement of Fatigue Strength for the Orthotropic Steel Decks with Reinforced Structural Details)

  • 경갑수;박경진;김교훈;박혜연
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.839-844
    • /
    • 2007
  • In order to reduce resultant stress of the connection detail of longitudinal and rib and floor beam, in this study, the parameter studies for the reinforcement details as the bulk head and the vertical rib were preformed with FE analysis. As the result, it was shown that reinforcement detail with the bulk head plate in longitudinal rig reduced generally the principal stress at the connection detail, but the stress concentration of the weld toe parts occurring fatigue crack increased. However, it was known that the reinforcement detail with the vertical rib in the rib is more effective than the bulk head plate of the reduction stress concentration in the weld toe parts.

  • PDF

Stiffness values and static analysis of flat plate structures

  • Unluoglu, Esref
    • Structural Engineering and Mechanics
    • /
    • 제6권4호
    • /
    • pp.427-437
    • /
    • 1998
  • Flat plate constructions are structural systems which are directly placed on columns without any beams. Various solution methods have been introduced for the solution of flat plate structures under horizontal and vertical loads. In most of these solution methods, models comprising of one column and one plate have been studied. In other solutions, however, co-behavior of two reciprocal columns has been investigated. In this study, interrelations of all the columns on one storey have been examined. At the end of the study structure consisting of nine columns and four plates has been chosen as a model. Then unit moment has been successively applied to each of these columns and unit moments carried over the other columns have been found. By working out solutions far plates and columns varying in ratio, carry-over factors have been found and these factors given in tables. In addition, fixed-end moment factors on the columns arising due to vertical load were also calculated. Then citing slope-deflection equations to which these results could be applied, some examples of moment and horizontal equilibrium equations have been given.

Assessment of the performance of composite steel shear walls with T-shaped stiffeners

  • Zarrintala, Hadi;Maleki, Ahmad;Yaghin, Mohammad Ali Lotfollahi
    • Earthquakes and Structures
    • /
    • 제23권3호
    • /
    • pp.297-313
    • /
    • 2022
  • Composite steel plate shear wall (CSPSW) is a relatively novel structural system proposed to improve the performance of steel plate shear walls by adding one or two layers of concrete walls to the infill plate. In addition, the buckling of the infill steel plate has a significant negative effect on the shear strength and energy dissipation capacity of the overall systems. Accordingly, in this study, using the finite element (FE) method, the performance and behavior of composite steel shear walls using T-shaped stiffeners to prevent buckling of the infill steel plate and increase the capacity of CSPSW systems have been investigated. In this paper, after modeling composite steel plate shear walls with and without steel plates with finite element methods and calibration the models with experimental results, effects of parameters such as several stiffeners, vertical, horizontal, diagonal, and a combination of T-shaped stiffeners located in the composite wall have been investigated on the ultimate capacity, web-plate buckling, von-Mises stress, and failure modes. The results showed that the arrangement of stiffeners has no significant effect on the capacity and performance of the CSPSW so that the use of vertical or horizontal stiffeners did not have a significant effect on the capacity and performance of the CSPSW. On the other hand, the use of diagonal hardeners has potentially affected the performance of CSPSWs, increasing the capacity of steel shear walls by up to 25%.

직봉의 기능을 포함한 합성보의 전단연결재 개발과 성능평가 (Development and Performance Evaluation of the Shear Connector of Composite Beam with Vertical Bars)

  • 김상섭;박동수;부윤섭
    • 한국강구조학회 논문집
    • /
    • 제23권6호
    • /
    • pp.725-736
    • /
    • 2011
  • 합성보에는 강재보와 철근콘크리트 슬래브의 경계면에서 작용하는 수평전단력에 저항하기 위해 전단연결재를 설치한다. 또한 일반적으로 강재보에는 거푸집용 철선일체형 데크플레이트가 주로 사용되는데 시공 중 데크플레이트의 탈락 및 낙하 등 안전을 확보하기 위해 철근트러스 거더가 끝나는 양단부의 상부철선에 직봉을 설치한다. 따라서, 본 연구는 이형철근과 강판을 이용하여 동등 이상의 내력을 확보하면서 직봉의 기능을 포함하는 새로운 형상의 전단연결재를 개발하고 활용하는 방안을 검토하였다. Push-out 실험결과, 이형철근과 강판을 사용한 전단연결재는 ${\phi}16$ 스터드커넥터 이상의 내력과 연성을 확보하였으며, 직봉과 전단연결재를 겸용하는 것이 가능한 것으로 나타났다.

Study on the progressive collapse resistance of CP-FBSP connections in L-CFST frame structure

  • Xiong, Qingqing;Wu, Wenbo;Zhang, Wang;Chen, Zhihua;Liu, Hongbo;Su, Tiancheng
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.437-450
    • /
    • 2022
  • When the vertical load-bearing members in high-rise structures fail locally, the beam-column joints play an important role in the redistribution of the internal forces. In this paper, a static laboratory test of three full-scale flush flange beam-reinforced connections with side and cover plates (CP-FBSP connection) with double half-span steel beams and single L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) was conducted. The influence of the side plate width and cover plate thickness on the progressive collapse resistance of the substructure was thoroughly analyzed. The failure mode, vertical force-displacement curves, strain variation, reaction force of the pin support and development of internal force in the section with the assumed plastic hinge were discussed. Then, through the verified finite element model, the corresponding analyses of the thickness and length of the side plates, the connecting length between the steel beam flange and cover plate, and the vertical-force eccentricity were carried out. The results show that the failure of all the specimens occurred through the cracking of the beam flange or the cover plate, and the beam chord rotations measured by the test were all greater than 0.085 rad. Increasing the length, thickness and width of the side plates slightly reduced the progressive collapse resistance of the substructures. The vertical-force eccentricity along the beam length reduced the progressive collapse resistance of the substructure. An increase in the connecting length between the beam flange and cover plate can significantly improve the progressive collapse resistance of substructures.

수직 배열된 평판에서 혼합대류 열전달 (Mixed Convection Heat Transfer from Vertical In-Line Plates)

  • 김상영;이재신;권순석
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.123-130
    • /
    • 1991
  • The mixed convection heat transfer from vertical inline plates has been studied numerically by the finite difference method and experimentally with Mach-Zehnder interferometer. The dimensionless spacing, $s/L_1$, the relative length, $L_2/L_1$ and the dimensionless temperature ratio, ${\Phi}_2/{\Phi}_1$ are varied parametically. The lower plate mean Nusselt numbers show same values as $s/L_1$, ${\Phi}_2/{\Phi}_1$ and $L_2/L_1$ increase. The upper plate mean Nusselt numbers increase as $s/L_1$ and ${\Phi}_2/{\Phi}_1$ increase, but $L_2/L_1$ decreases. The upper plate mean Nusselt number is higher than the lower plate mean Nusselt for $s/L_1$ 1.8 at Re=100, $Gr=10^4$, Pr=0.71, $L_2/L_1=0.5$ and ${\Phi}_2/{\Phi}_1=1.0$. A comparison between the experimental and numerical results show good agreement.

  • PDF