• 제목/요약/키워드: Vertical outer wall

검색결과 43건 처리시간 0.027초

건축공간에서의 Vertical Garden의 활용에 관한 연구 - 건축물 외벽면 디자인 활용방법 - (The Research for Making Flexible Use of Vertical Garden in Architectural Space - The activated use design for architectural outside walls' space -)

  • 류효매;김은정;홍관선
    • 한국실내디자인학회논문집
    • /
    • 제23권4호
    • /
    • pp.12-22
    • /
    • 2014
  • In this study, the basic information and study design characteristics of the Building Outer Wall Vertical Greening were analyzed. Recorded according to the type of research and analysis, through numerical statistics. Building Outer Wall Vertical Greening design the most appropriate and effective ways to present and try to guidelines. The scope of the research of Building Outer Wall Vertical Greening(2001-2013) was selected the most representative examples. Theory and statistical data analysis and case study research was conducted. The main academic monographs, Library Literature, specializing in design magazines and excerpts from the 28 cases analyzed specifically. Building Outer Wall Vertical Greening should be designed synthetically geographical features of the project, existing material, to consider the value of the building. Architect must be designed depending on accident and comprehensive expertise for architectural design of Building Outer Wall Vertical Greening. Building Outer Wall Vertical Greening requires the professional and comprehensive design approach depending on support of the government and people. However, purpose of use, plant, color, Formative expression, culture, locality, maintenance is properly applied in the design process is not easy.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구 (An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method)

  • 박정우;조남욱
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.75-85
    • /
    • 2018
  • 2016년 6월 영국 그렌펠 타워 화재는 외단열에 의한 수직화재확산으로 인한 대표적인 피해사례이다. 외단열 공법에서 많이 사용되는 유기단열재는 단열성능이 좋은 반면 화재에 취약한 단점이 있다. 알루미늄 복합패널을 외벽 마감재로 사용하는 외단열 공법에서 알루미늄 내부에 사용되는 플라스틱은 수직 화재확산의 원인으로 지목되고 있다. 알루미늄복합패널을 외벽에 고정하기 위해 사용되는 철재 프레임 때문에 외벽과 외벽 마감재 사이에 중공층이 형성된다. 외벽에 화재가 발생하면 가연성외벽의 연소뿐만 아니라 단열재로부터 발생된 화염이 중공층을 통해 수직으로 급격히 확산되어 인명 및 재산피해가 발생할 수 있다. 국내의 경우 국토교통부고시 2015 - 744에 의한 소재단위 성능시험이 수행되고 있으며, 영국에서는 실제 규모의 화재시험으로 외벽의 수직화재확산 시간의 측정이 가능한 BS8414 시험이 시행되고 있다. 본 연구에서는 현행 국내 고시 기준으로 적합한 준불연 소재의 알루미늄복합패널을 대상으로 영국에서 시행되고 있는 실규모 외벽화재시험(BS 8414)을 수행하여 수직화재확산에 대한 거동 관찰과 현재 마감재료의 소재단위 평가의 한계를 확인하고자 하며, 실제 규모의 화재 시험을 통한 외벽화재 화재확산 방지를 위한 시스템 도입 필요성 확인하고자 한다.

단형 수직환형 다공성 물질에 있어서의 자연 대류에 대한 수치해석 (Numerical Study of Natural Convection in Porous Media Bounded by Short Vertical Annulus)

  • 윤종혁;김종보
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.979-990
    • /
    • 1989
  • 본 연구에서는 종횡비가 1보다 크고 내부 벽면에 일정한 열유속을 가지고 외부벽은 등온으로 유지되며 나머지 벽은 단열된 수직환형 원통형에 대한 연구를 바탕으로 같은 경계조건으로 종횡비를 1이하로 감소할 때에 Darcy의 법칙을 기초로 유한차분법을 사용, 수치적으로 해석하여 다세포 유동의 존재 여부와 온도 분포 및 열전달율을 계산하였다.

표면조도가 있는 난류경계층에서의 직접수치모사 (Direct numerical simulation of the turbulent boundary layer with rod-roughened wall)

  • 이승현;성형진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.445-448
    • /
    • 2006
  • The effects of surface roughness on a spatially-developing turbulent boundary layer (TBL) were investigated by performing direct numerical simulations of TBLs over rough and smooth walls. The Reynolds number based on the momentum thickness was varied in the range $Re_{\theta}=300{\sim}1400$. The roughness elements used were periodically arranged two-dimensional spanwise rods, and the roughness height was $k=1.5{\theta}_{in}$, which corresponds to $k/{\delta}=0.045{\sim}0.125$. To avoid generating a rough wall inflow, which is prohibitively difficult, a step change from smooth to rough was placed $80{\theta}_{in}$ downstream from the inlet. The spatially-developing characteristics of the rough-wall TBL were examined. Along the streamwise direction, the friction velocity approached a constant value and a self-preserving form of the turbulent stress was obtained. Introduction of the roughness elements affected the turbulent stress not only in the roughness sublayer but also in the outer layer. Despite the roughness-induced increase of the turbulent stress in the outer layer, the roughness had only a relatively small effect on the anisotropic Reynolds stress tensor in the outer layer. Inspection of the triple products of the velocity fluctuations revealed that introducing the roughness elements onto the smooth wall had a marked effect on vertical turbulent transport across the whole TBL. By contrast, good surface similarity in the outer layer was obtained for the third-order moments of the velocity fluctuations.

  • PDF

수직동심환상관에서 반경방향 보이드율의 변동특성 (Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권5호
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

수직레일을 이용한 건물 외벽청소로봇 개발방향 연구 (Fundamental Study of the Building Exterior Wall Cleaning Robot using Vertical rails)

  • 박수열;김균태;한재구;김창한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.185-187
    • /
    • 2012
  • Recently increasing high-rise building cleaning on the exterior walls of high-rise buildings, there has been increased interest. Building exterior cleaning is cleaned by a cleaning robot and how to clean the exterior walls of the building and exterior glass cleaned by personnel. Number of stories in the building increases, being carried out by personnel cleaning the outer wall as there is a limit order to overcome this method. therefor, this study is a new exterior wall cleaning device has been proposed.

  • PDF

Seismic tests of RC shear walls confined with high-strength rectangular spiral reinforcement

  • Zhao, Huajing;Li, Qingning;Song, Can;Jiang, Haotian;Zhao, Jun
    • Steel and Composite Structures
    • /
    • 제24권1호
    • /
    • pp.1-13
    • /
    • 2017
  • In order to improve the deformation capacity of the high-strength concrete shear wall, five high-strength concrete shear wall specimens confined with high-strength rectangular spiral reinforcement (HRSR) possessing different parameters, were designed in this paper. One specimen was only adopted high-strength rectangular spiral hoops in embedded columns, the rest of the four specimens were used high-strength rectangular spiral hoops in embedded columns, and high-strength spiral horizontal distribution reinforcement were used in the wall body. Pseudo-static test were carried out on high-strength concrete shear wall specimens confined with HRSR, to study the influence of the factors of longitudinal reinforcement ratio, hoop reinforcement form and the spiral stirrups outer the wall on the failure modes, failure mechanism, ductility, hysteresis characteristics, stiffness degradation and energy dissipation capacity of the shear wall. Results showed that using HRSR as hoops and transverse reinforcements could restrain concrete, slow load carrying capacity degeneration, improve the load carrying capacity and ductility of shear walls; under the vertical force, seismic performance of the RC shear wall with high axial compression ratio can be significantly improved through plastic hinge area or the whole body of the shear wall equipped with outer HRSR.

점토지반에 이중벽체가 적용된 해상폐기물매립장의 적정 차수 기준 (Proper Regulation of the Cutoff System in Offshore Landfill Built on Clay Ground with Double Walls)

  • 황웅기;김향은;최호성;김태형
    • 한국지반공학회논문집
    • /
    • 제35권8호
    • /
    • pp.5-15
    • /
    • 2019
  • 이 연구는 오염원 유출을 방지하기 위한 해상폐기물매립장 차수시스템에 요구되는 적절한 기준을 제안하기 위해 수행되었다. 차수시스템은 바닥층과 연직벽으로 구성된다. 바닥층은 불투수 점토층으로 연직벽은 이중벽체로 외곽벽체는 강관쉬트파일로 외력에 대한 저항을 담당하고 연직내부벽체가 차수를 담당하는 것으로 가정하였다. SEEP/W와 CTRAN/W 프로그램을 이용하여 침투-이류-분산 해석을 정상류 및 비정상류 조건에서 실시하였다. 해석결과, 정상류 조건에서 비정상류 조건 보다 오염원 이동이 크게 나타나 설계관점에서 차수기준은 정상류조건에서 산정된 값을 적용하는 것이 타당한 것으로 나타났다. 바닥층의 점토지반이 균질하고 연직차수시스템의 시공에 문제가 없다는 전제하에 정상류조건에서 오염원 이동의 차수에 요구되는 점토층 및 연직차수벽의 투수계수, 두께, 근입깊이 등이 제안되었다.