• 제목/요약/키워드: Vertical gap

검색결과 294건 처리시간 0.032초

고온 버퍼층을 이용한 ZnO 박막의 MOCVD 성장 (Growth of ZnO thin films by MOCVD using the buffer layers grown at high temperature)

  • 김동찬;공보현;조형균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.108-109
    • /
    • 2006
  • ZnO semiconductor has a wide band gap of 3.37 eV and a large exciton binding energy of 60 meV, and displays excellent sensing and optical properties. In particular, ZnO based 1D nanowires and nanorods have received intensive attention because of their potential applications in various fields. We grew ZnO buffer layers prior to the growth of ZnO nanorods for the fabrication of the vertically well-aligned ZnO nanorods without any catalysts. The ZnO nanorods were grown on Si (111) substrates by vertical MOCVD. The ZnO buffer layers were grown with various thicknesses at $400^{\circ}C$ and their effect on the formation of ZnO nanorods at $300^{\circ}C$ was evaluated by FESEM, XRD, and PL. The synthesized ZnO nanorods on the ZnO film show a high quality, a large-scale uniformity, and a vertical alignment along the [0001]ZnO compared to those on the Si substrates showing the randomly inclined ZnO nanorods. For sample using ZnO buffer layer, 1D ZnO nanorods with diameters of 150-200 nm were successively fabricated at very low growth temperature, while for sample without ZnO buffer the ZnO films with rough surface were grown.

  • PDF

전류가 관통하는 원통형 자성체에 미치는 전자기력식의 통일성에 대한 고찰 (An Observation of Unified Force Expression in The Cylindrical Magnetic Material with a Vertical Current Running Through Its Center)

  • 최홍순
    • 한국자기학회지
    • /
    • 제21권5호
    • /
    • pp.174-179
    • /
    • 2011
  • 지금까지 자성체에 미치는 전자기력을 계산하기 위해서는, 맥스웰 응력법, 가상변위법, 자하법, 자화전류법등이 널리 사용되어 왔으며, 이들은 자성체 덩어리 전체에 미치는 전자기력을 계산하는 데 있어 모두 정당한 결과를 가져온다고 보고 있다. 그러나 전자기력 밀도식의 완전한 형태에 대해서는 아직 까지도 논란이 있으며, 각 방법에 의한 표면 전자기력 밀도는 식과 수치해석 모두 다른 결과를 보인다. 본 연구는 전자기력밀도를 체적력으로 국한하여 가상공극법을 적용하였을 때, 모두 같은 형태의 식으로 도출이 됨을 해석식이 존재하는 모델을 통하여 보여준다. 즉, 가상공극 개념을 적용할 경우, 체적력 전자기력 밀도식의 통일 가능성을 보여 주는 것이다.

강재 단순보 단부에 근접한 개구부의 구조성능에 관한 실험적 연구 (An Experimental Study on the Structural Performance of Openings at End Steel Beams)

  • 한동호;윤성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.138-145
    • /
    • 2020
  • 본 연구는 강재 단순보의 유공보 시스템에서 개구부를 지지점 에 근접한 위치에 설치하는 경우에 대하여 구조성능을 파악하고자 실험을 실시하였다. 또한 수직·수평 강판을 이용한 개구부 보강에 대하여도 실험을 통하여 구조성능을 파악하였다. 강재 단순보에서 개구부가 지지점에 근접한 위치인 강재보 높이의 절반(D/2)인 경우에 강재보 높이(D)인 경우보다 적절한 개구부 위치인 것을 알 수 있었다. 또한 보강방법으로는 수직강판 보강보다는 수평강판 보강이 보강효과가 크며, 개구부와 강판의 간격이 없는 것이 구조성능이 더 큰 결과를 얻을 수 있었다.

Axially-compressed behavior of CFRP strengthening steel short columns having defects

  • Omid Yousefi;Amin Shabani Ammari
    • Structural Engineering and Mechanics
    • /
    • 제91권1호
    • /
    • pp.49-61
    • /
    • 2024
  • In recent decades, the majority of studies have concentrated on the utilization of Steel Square Hollow Section (SHS) columns, with minimal attention given to reinforcing columns exhibiting inherent defects. This study addresses this gap by introducing initial vertical and horizontal defects at three distinct locations (top, middle, and bottom) and employing Carbon-FRP for reinforcement. The research investigates the dimensional and positional impacts of these defects on the axial behavior of SHS columns. A total of 29 samples, comprising 17 with defects, 11 strengthened, and 1 defect-free control, underwent examination. The study employed ABAQUS modeling and conducted experimental testing. Results revealed that defects located at different positions significantly diminished the load-bearing capacity and initial performance of the steel columns. Axial loading induced local buckling and lateral rupture, particularly at the defect side, in short columns. Notably, horizontal (across the column's width) and vertical (along the column's height) defects in the middle led to the most substantial reduction in strength and load-bearing capacity. The axial compressive failure increased with the length-to-width ratio of the defect. Moreover, the application of four carbon fiber layers to strengthen the steel columns resulted in increased Energy Dissipation and a delayed onset of local buckling in the face of axial ruptures.

저위교합환자의 보철적 접근법과 이론 : Pseudo Class III 교합환자 증례 (The prosthetic approach and principle for an collapsed VDO ; A clinical case of pseudo Class III patient)

  • 권긍록;최대균
    • 구강회복응용과학지
    • /
    • 제20권2호
    • /
    • pp.121-134
    • /
    • 2004
  • 진단과 치료과정을 통해서 후천적으로 습득된 부정교합을 가진 부분무치악자 성인에게서, 교합고경을 회복해 줌으로써 3급 부정교합 안모에서 정상교합상태의 안모와 기능을 부여할 수 있었다. 대부분의 부분무치악자에서 치조골의 위축, 그리고 감소된 교합고경 인해 이루어진 부정교합자에게서 교합고경의 수복은 매우 어려운 작업이다. 적절한 안모의 심미는 대체로 interlabial gap이 약 0-2mm일 때 얻어진다. 이것과 함께, 제한된 입술 지지도(lip competence)가 교합고경 수복과 적절한 안모의 심미를 위한 지표로 사용될 수 있다. 소개된 증례의 경우는, 7년 이상의 계속 관찰 결과, 성공적인 치료였다고 판단된다. 교합고경을 증가시킨 경우이긴 하지만, 사실은 원래의 정상 교합고경으로 회복 시켜주었다고 하는 것이 더욱 옳은 표현일 것 같다. 교합고경을 증가시키는 작업은 안모의 수복, 절치부의 외상성 교합을 수정하고 하악을 후퇴시키는데 매우 어렵고도 중요한 일이다. 최종적으로, 3급 부정교합이 수정되고, 적절한 교합고경을 가지게 되었으며, 위축된 구치 무치악부가 rigid support 개념으로 제작된 가철성 의치로 수복되었다. 부분 무치악부를 가진 후천적 부정교합자의 치료의 결과로 획득한 치아 및 안모의 심미와 이것의 장기간 안정성은 다음의 관계를 잘 고려함으로써 지속될 수 있을 것으로 사료된다: 1) 이상적인 교합고경에서의 교합수복, 2) 상,하악골 관계에서 기능적으로 유도되는 최종 교합의 허용, 3) lip competence (입술 적응) 한계 내에서 기능적으로 유도되는 최종교합.

U 자형 전자석을 사용하는 자기부상열차의 횡진동 저감 연구 (Lateral Vibration Reduction of a Maglev Train Using U-shaped Electromagnets)

  • 한종부;김기정;한형석;김성수
    • 대한기계학회논문집A
    • /
    • 제36권11호
    • /
    • pp.1447-1453
    • /
    • 2012
  • 도시형 자기부상열차는 U 자형 전자석만을 사용하여 부상공극을 일정하게 유지하며 주행한다. U자형 전자석은 그 형상 특성으로 인하여 전자석 위치에 따라 안내력을 동시에 갖기 때문에 능동적 횡공극 제어가 없이도 차량을 레일에 따라 안내할 수 있는 장점을 갖는다. 그러나 횡공극을 제어하기 않기 때문에 횡진동이 증가하여 승차감 및 주행안정성에 악영향을 미칠 수 있다. 본 논문에서는 능동제어가 없이도 횡진동을 저감시키기 위한 방법으로 횡댐퍼 적용 효과에 대한 분석이 이루어진다. 이를 위하여 자기부상열차의 횡방향 고유진동특성을 우선 해석하고, 횡방향 댐퍼를 설치했을 때의 진동저감 효과 분석이 이루어진다. 정확한 횡진동 예측을 위하여 자기부상열차의 3 차원 다물체 동역학 모델을 사용하였다. 본 논문의 결과를 통해서 자기부상열차의 횡진동 저감을 위한 횡댐퍼 채택 제안에 활용하고자 한다.

단순교합기에 의한 하악운동의 오차에 대한 실험적 연구 (An Experimental study on the gap of movement by the hinge articulator)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

원통형 공진기를 이용한 유전율 측정방법에서 측정모드 선택에 관한 연구 (A Study on the Selection of Measuring Mode in the Permittivity Measurement Using a Circular Cylindrical Cavity)

  • 이원희;강순국;최홍주;허정;이상영
    • 한국전자파학회논문지
    • /
    • 제10권2호
    • /
    • pp.218-226
    • /
    • 1999
  • 비유전율 측정을 정확하게 할 수 있는 모드 선택 방법에 대하여 기술한다. 비유전율 측정을 위하여 유전체를 가득 채운 원통형 공진기를 이용하였다. 원통형 공진기에 유전체를 가득 채울 때 유전체의 가공오차로 인하여 틈이 발생한다. 틈에 의한 공진주파수 변화가 덜 민감한 모드를 이용하여 비유전율을 계산하면 정확히 비유전융을 구할 수 있다. 틈에 의한 공진주파수 변화를 확인하여 본 결과 $TE_{011}$모드는 높이 방향과 반지름 방향 틈에서 평균 0.009%의 공진주파수 편차를 보였다.$TE_{011}$모드는 틈에 의한 공진주파수 민감도가 기본 모드 중 가장 덜 민감하였다. $TE_{011}$모드를 이용하여 측정하면 보다 정확히 비유전율을 구할 수 있다.

  • PDF

연속 주조기의 주형 진동 진단 시스템의 개발 (Development of Diagnosis System of Mold Oscillation in a Continuous Slab Casting Machine)

  • 최재찬;이성진;조강형;전형일
    • 한국정밀공학회지
    • /
    • 제13권5호
    • /
    • pp.84-94
    • /
    • 1996
  • In order to prevent shell sticking by providing sufficient lubrication between the strand and the mold, the mold oscillation has been used. Now it is well known that the shape of the oscillation curve has a decisive effect on the surface quality of the cast product. Besides, oscillation parameters such as stroke and frequency are also very important. In order to guarantee that parameters which have been found to be optimal for a certain grade of steel do not change with time, periodical checks of the physical condition of the whole equipment are necessary. The portable mold oscillation analyzer with integrated computer, developed by POSCO, records the movement of the mold in every spatial direction. The system uses the gap sensors to measure the mold movement (displacement ) in the two horizontal directions according to the mold narrow and broad faces and the vertical strokes in the four corners of mold. The gap sensor is a non-contacting minute displacement measuring device using the principle of high frequency eddy current loss. The mold oscillation diagnosis system integrates the gap sensors, their converters and the industrial portable computer with plug-in data acquisition boards. The all programs, such as the fast Fourier transformation module (amplitude and phase spectrums) and harmonic analysis module, was coded by LabVIEW$^{TM}$ software as the graphical language. In an own 'expert module' which is included in the diagnosis program, one can obtain much information about the mold oscillation equipment.

  • PDF

임플란트 보철물의 연결 여부에 따른 유한요소응력분석 (Finite Element Analysis on the Supporting Bone according to the Connection Condition of Implant Prosthesis)

  • 강재석;정제옥;이승훈
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.31-42
    • /
    • 2007
  • The purpose of this study was to compare the stress distribution according to the splinting condition and non-splinting conditions on the finite element models of the two units implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on the mandibular 1st and 2nd molars. A cemented abutment and gold screw were used for superstructures. A FEA models assumed a state of optimal osseointegration, as the bone quality, inner cancellous bone and outer 2 mm compact bone was designed. This concluded that the cortical and trabecular bone were assumed to be perfectly bonded to the implant. Splinting condition had 2 mm contact surface and non-splinting condition had $8{\mu}m$ gap between two implant prosthesis. Two group (Splinting and non-splinting) were loaded with 200 N magnitude in vertical axis direction and were divided with subdivision group. Subdivision group was composed of three loading point; Center of central fossa, the 2 mm and 4 mm buccal offset point from the central fossa. Von Mises stress value were recorded and compared in the fixture-bone interface and bucco-lingual sections. The results were as follows; 1. In the vertical loading condition of central fossa, splinting condition had shown a different von Mises stress pattern compared to the non-splinting condition, while the maximum von Mises stress was similar. 2. Stresses around abutment screw were more concentrated in the splinting condition than the non-splinting condition. As the distance from central fossa increased, the stress concentration increased around abutment screw. 3. The magnitude of the stress in the cortical bone, fixture, abutment and gold screw were greater with the 4 mm buccal offset loading of the vertical axis than with the central loading.