• 제목/요약/키워드: Vertical effective range

검색결과 87건 처리시간 0.028초

Comparative Study of the Biomechanical Factors in Range of Motion, Muscle Activity, and Vertical Ground Reaction Force between a Forward Lunge and Backward Lunge

  • Park, Samho;Huang, TianZong;Song, Junyoung;Lee, Myungmo
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권2호
    • /
    • pp.98-105
    • /
    • 2021
  • Objective: The purpose of this study was to examined the kinematic relationship and differences through the range of motion (ROM), muscle activity, and vertical ground reaction force (VGRF) during forward and backward lunge movements, which are effective in improving muscle strength and balance ability of the lower extremities, and to provide clinical information on more efficient lunge movements. Design: Cross-sectional study Methods: Fifteen adult males who met the selection criteria were tested for their dominant feet.Forward and backward lunges were then performed, and the ROM, muscle activity, and VGRF were measured for kinematic analysis during the lunge movement.The differences betweenthe forward lunge and backward lunge intervention were examined using a paired t-test. Results: A significant increase in the ROM of the knee and ankle was observed during the forward and backward lunges (p<0.05). In addition, in terms of the muscle activity, the peak values of the vastus medialis oblique (VMO) and VGRF also showed a significant increase in the forward lunge compared to the backward lunge (p<0.05). Conclusions: This study showed an increase in VGRF peak value, knee and ankle ROM, and VMO muscle activity during forward lunge. Based on these results, it is considered necessary to apply differently depending on the direction of progress in consideration of the musculoskeletal situation and physical ability during the lunge movement.

어깨관절 아탈구가 있는 만성 뇌졸중환자에게 기능적 전기자극 치료가 기능회복에 미치는 효과 (Effect of Functional Recovery for the Functional FES upon Chronic Stroke Patients with Shoulder Subluxation)

  • 황룡;김찬문
    • 대한물리치료과학회지
    • /
    • 제16권4호
    • /
    • pp.75-81
    • /
    • 2009
  • Background: The purpose of this study was to confirm whether surface FES was effective in the function of chronic stroke patients' affected shoulder and whether FES influenced their functional abilities in ADL, as well. Method: the subjects were inpatients at a general hospital in Gyeonggi-Do, Korea and had been diagnosed as a sub-luxation in their affected shoulder. They were 26 and were separated to an experimental group and a control group, in equal number. Both groups had gotten an exercise treatment for 6 weeks. The control group didn't get any FES as opposed to the experimental group. Result: in the experimental group there was no statistical significant difference in the vertical space and the joint space, even though the space was reduced. In the control group, there was no statistical significant difference, either. Moreover, each space of their shoulders was increased. In the range of motion of each group, there was no statistical significant difference. In functional independent ability, there was a significant difference in an experimental group. In contrast, there was no difference in a control group. Conclusion: this result suggests that FES should be effective in the sub-luxation of the patients' affected shoulder and the range of motion of their shoulders. On the other hand, compared to the previous items, FES was quite effective in the functional improvement.

  • PDF

천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구 (A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit)

  • 조성우;임영빈;이경희
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

소규모 사무실에 적용된 조광제어 시스템의 최적제어를 위한 주광변화 분석 (Analyses on Daylight Variations for Optimum Controls of Daylight Dimming Systems in a Small Office)

  • 윤연주;백용규;김수영
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.433-442
    • /
    • 2012
  • The influence of outdoor sky conditions on photosensor signals were examined to determine an appropriate index that is effectively used for optimum illuminance fluctuation when a daylight dimming system is used for a small office. Field measurements were conducted under various sky conditions. Results indicate that the outdoor global and vertical illuminance fluctuated within narrow ranges under clear and overcast sky conditions. The fluctuation of sky ratio under partly-cloudy sky caused wide ranges of illumnance fluctuation. A partially-shielded photosensor at backwall produced 56% of light output from fixtures controlled by a photosensor at ceiling. This implies that the photosensor at backwall does not always guarantee target illuminance due to the less output. The fluctuation of light output from fixtures were insignificant under clear and overcast sky. The fluctuation range of photosensor illuminance under partly-cloudy sky caused wide fluctuation ranges of light output. Regression result implies that the outdoor vertical illuminance was recommended for an effective index that is used for control of light output.

Load Transferring Mechanism and Design Method of Effective Detailings for Steel Tube-Core Concrete Interaction in CFT Columns with Large-Section

  • Li, Yuanqi;Luo, Jinhui;Fu, Xueyi
    • 국제초고층학회논문집
    • /
    • 제7권3호
    • /
    • pp.223-232
    • /
    • 2018
  • Two novel types of construction detailings, including using the distributive beam and the inner ring diaphragm in the joint between large-section CFT columns and outrigger truss to enhance the transferring efficiency of huge vertical load, and using the T-shaped stiffeners in the steel tube of large-section CFT columns to promote the local buckling capacity of steel tubes, were tested to investigate their working mechanism and design methods. Experimental results show that the co-working performance between steel tube and inner concrete could be significantly improved by setting the distributive beam and the inner ring diaphragm which can transfer the vertical load directly in the large-section CFT columns. Meanwhile, the T-shaped stiffeners are very helpful to improve the local bulking performance of steel tubes in the column components by the composite action of T-shaped stiffeners together with the core concrete under the range of flange of T-shaped stiffeners. These two approaches can result in a lower steel cost in comparison to normal steel reinforced concrete columns. Finally, a practical engineering case was introduced to illustrate the economy benefits achieved by using the two typical detailings.

밀폐형 지중열교환기 설계를 위한 지중 유효열전도도 데이터베이스 구축 (Construction of Ground Effective Thermal Conductivity Database for Design of Closed-Loop Ground Heat Exchangers)

  • 최재호;손병후;임효재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.776-781
    • /
    • 2008
  • A ground heat exchanger in a GSHP system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on the thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This paper is part of a research project aiming at constructing a database of these site-specific properties, especially ground effective thermal conductivity. The objective was to develop and evaluation method, and to provide this knowledge to design engineers. To achieve these goals, thermal response tests were conducted using a testing device at nearly 150 locations in Korea. The in-situ thermal response is the temperature development over time when a known heating load imposed, e.g. by circulating a heat carrier fluid through the test exchangers. The line-source model was then applied to the response test data because of its simplicity. From the data analysis, the range of ground effective thermal conductivity at various sites is $1.5{\sim}4.0\;W$/mK. The results also show that the ground effective thermal conductivity varies with grouting materials as well as regional geological conditions and groundwater flow.

  • PDF

Semicircular Horizontal Approach in Breast Reduction: Clinical Experience in 38 Cases

  • Shin, Hee Su;Lee, Yong Hae;Jung, Sung Gyun;Lee, Doo Hyung;Roe, Young;Cha, Jong Hyun
    • Archives of Plastic Surgery
    • /
    • 제42권4호
    • /
    • pp.446-452
    • /
    • 2015
  • Background Various techniques are used for performing breast reduction. Wise-pattern and vertical scar techniques are the most commonly employed approaches. However, a vertical scar in the mid-lower breast is prominent and aesthetically less pleasant. In contrast, a semicircular horizontal approach does not leave a vertical scar in the mid breast and transverse scars can be hidden in the inframammary fold. In this paper, we describe the experiences and results of semicircular horizontal breast reductions performed by a single surgeon. Methods Between September 1996 and October 2013, our senior author used this technique in 38 cases in the US and at our institution. We used a superiorly based semicircular incision, where the upper skin paddle was pulled down to the inframammary fold with the nipple-areola complex pulled through the keyhole. Results The average total reduction per breast was 584 g, ranging from 286 to 794 g. The inferior longitudinal pedicle was used in all the cases. The average reduction of the distance from the sternal notch to the nipple was 13 cm (range, 11-15 cm). The mean decrease in the bra cup size was 1.7 cup sizes (range, a decrease of 1 to 3). We obtained very satisfactory results with a less noticeable scar, no complication such as necrosis of the nipple or the skin flap, wound infection, aseptic necrosis of the breast tissue, or wound dehiscence. One patient had a small hematoma that resolved spontaneously. Conclusions This technique is straightforward and easy to learn, and offers a safe, effective, and predictable way for treating mammary hypertrophy.

변환요소에 따른 LOOPED WIRE의 탄성 변화에 관한 연구 (A STUDY ON THE CHANGES OF THE ELASTIC PROPERTIES TN LOOPED WIRES BY VARIABLE FACTORS)

  • 나용인;김상철
    • 대한치과교정학회지
    • /
    • 제25권3호
    • /
    • pp.263-271
    • /
    • 1995
  • Canine retraction spring과 같은 looped wire에서, 각 변환요소에 따라 변하는 탄성 정도를 알아보기 위하여, wire의 재료, 굵기, loop에 소요된 길이, loop의 모양, gabling의 여부 등 5가지의 변환요소를 설정하여, 각 wire activation시의 탄성을 range, force, stiffness등의 면에서 알아보고자 하였다. wire의 재료적인 면에서 Hi-T (Unitek Co.)와 blue Elgiloy (Rocky Mountain Orthodontics)를 선택하였으며, 굵기로는 .016"$\;\times\;$.022" 와 .018"$\;\times\;$.025"를 선택하였다. loop 자체에 소요된 wire 길이를 15mm와 20mm의 두가지로, loop의 모양을 vertical open loop과 vertical closed loop의 두가지로, gabling의 양을 $0\circ$$30\circ$의 두가지로 하여 각각 제작하였다. 따라서 wire의 재료와 굵기, loop의 길이와 모양, gabling의 5가지 변환요소에 따라 32개군으로 구분되었으며, 각 군의 시료수는 8개씩으로, 총 256개의 시료를 대상으로 하였다. Instron(4202, Instron Co, USA)을 사용하여 각 시료의 하중변형 곡선을 얻었으며 elastic limit에서의 하중과 변형을 계측하고, 그때의 stiffness(force/range)를 산출하여, ANOVA 등의 통계처리로 32개군 간의 상관성을 조사하였다. 그 결과 wire의 재료, 굵기, loop의 길이, 모양, gabling모두가 looped wire의 하중 변형도에 유의한 영향을 미치는 것을 관찰할 수 있었으며, 탄성범위에서의 force는 Hi-T, .016"$\;\times\;$.022", loop 길이 20mm, open loop, non-gable군에서 가장 적었으며, blue Elgiloy, .018"$\;\times\;$.025", loop 길이 15mm, closed loop, non-gable군에서 가장 컸다. 탄성범위에서의 range는 Hi-T, .018"$\;\times\;$.025", loop길이 15mm, open loop, non-gable군이 가장 적었으며, Hi-T, .016"$\;\times\;$.022", loop길이 20mm, closed loop, gable군에서 가장 컸다. 또한 Looped wire의 탄성에 가장 큰 영향을 미치는 변환요소는 loop의 모양과 길이였으며, gabling의 영향이 가장 적었다.

  • PDF

조광제어 시스템 적용시 실내조도의 변동예측을 위한 포토센서의 주광조도 분석 (Analyses on Photosensor Illuminance for Prediction of Fluctuating Illuminance by Daylight Dimming Control Systems)

  • 김수영
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.788-797
    • /
    • 2010
  • This study examines the influence of fluctuating daylight illuminance on daylight dimming control systems. Field measurements were performed for a full-scale mocked-up model under various daylight conditions in winter. Fluctuating ranges for a partially-shielded photosensor were great when the variation of sky ratio was great. When solar altitude was lower the illuminance and fluctuating range of illuminance were great due to the influence of direct components of daylight and the interrefelction between surfaces in rear area of space. It implies that daylight dimming system would not function effectively, unless the desktop illuminance by daylight is enough. Fluctuation ranges of photosensor illuminance were lower than 50 lx under clear sky conditions, but they were greater than 100 lx under partly-cloudy sky conditions. It means that the fluctuation range of electric light output of lighting fixture would greater under the partly-cloudy conditions and cause potential visual annoyance to occupants. Outdoor vertical illuminance reaching the windows would be an effective factor that can be used to predict the fluctuation of photosensor signals for effective controls of daylight dimming system.

지중 열교환기 보어홀에서의 유효 열전도도 및 열저항 산정 (Evaluation of Effective Thermal Conductivity and Thermal Resistance in Ground Heat Exchanger Boreholes)

  • 손병후;신현준;박성구
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.695-703
    • /
    • 2005
  • The objective of this study is to determine the effective thermal conductivity and thermal resistance values in test boreholes with three different fill materials. To evaluate these heat transfer properties, in-situ tests on four vertical boreholes were conducted by adding a monitored amount of heat to water over various test lengths. Two parameter estimation models, line-source and numerical one-dimensional models, for evaluation of thermal response test data were compared when applied on the same four data sets. Results show that the average thermal conductivity deviation between measured data and these two models is in the range of $3.03\%$ to $4.45\%$. The effect of increasing grout thermal conductivity from 1.34 to 1.82 $W/m^{\circ}C$ resulted in overall increases in effective formation thermal conductivity by $11.1\%$ to $51.9\%$ and reductions in borehole thermal resistance by $11.6\%$ to $26.1\%$.