• 제목/요약/키워드: Vertical drop test

검색결과 50건 처리시간 0.024초

가속도계와 동적신호분석기를 이용한 건축물 바닥슬래브 동특성 및 수직진동 전달특성 측정 (Measurements on the Characteristics of Dynamic and Vertical Vibration Transfer according to floors of Building Structures using Accelerometer and Dynamic signal analyzer)

  • 전호민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.29-34
    • /
    • 2006
  • In general, the vertical vibration problems for .strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on three building structures. The results from the experiments are analyzed and compared. with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces.

  • PDF

전단벽식 건축구조물 수직진동의 수평방향 전달특성에 관한 실험연구 (An Experimental Study on the Vertical Vibration Transfer in Horizontal Way according to Shear Wall Building Structures due to Exciting Vibration Forces)

  • 전호민
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.270-282
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions to near-rooms on the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on two building structure. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs, and are effected the shear wall on the Path of the vibration transfer.

탄소나노튜브를 기반으로 하는 충격흡수제의 물리적 특성 비교분석 (The Comparative Analysis on Mechanical Property Test of Carbon Nanotube-based Shock Absorbers)

  • 김종우;채원식
    • 한국운동역학회지
    • /
    • 제22권2호
    • /
    • pp.237-242
    • /
    • 2012
  • The purpose of this study was (a) to develop carbon nanotube-based shock absorbers for reducing potentially harmful impact forces and excessive foot pronation, and (b) to briefly determine how the effects of carbon nanotube-based shock absorbers on biomechanical variance during drop landing. A university student(age: 24.0 yrs, height: 176.2 cm, weight: 679.5 N) who has no musculoskeletal disorder was recruited as the subject. Hardness, specific gravity, tensile strength, elongation, 100% modulus, tear strength, split tear strength, compression set, resilience, vertical GRF, and loading rate were determined for each material. For each dependent variable, a descriptive statistics was used for different conditions. The property test results showed that tensile strength, tear strength, split tear strength, compression set, and resilience in carbon nanotube-based shock absorbers were greater than general Ethylene Vinyl Acetate(EVA). These indicated that resistance against variable strength in developed carbon nanotube-based shock absorbers were greater than general EVA. In vertical GRF of CNTC was less than those of EVA during drop landing and loading rate of CNTC was greater than EVA. It seems that the use of CNT can be a effective way of reducing and controlling shock from impact.

마이크로채널관 내 2상 유량분배, 상분리 및 압력강하 (Two-Phase Flow Distribution, Phase Separation and Pressure Drop in Multi-Microchannel Tubes)

  • 조홍기;조금남;윤백;김영생;김정훈
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.828-837
    • /
    • 2004
  • The present study investigated two-phase flow distribution, phase separation and pressure drop in multi-microchannel tubes under adiabatic condition. The test section consisted of inlet and outlet headers with the inner diameter of 19.4㎜ and 15 parallel microchannel tubes. Each microchannel tube brazed to the inlet and outlet headers and had 8 rectangular ports with the hydraulic diameter of 1.32㎜. The key experimental parameters were orientation of header (horizontal and vertical), flow direction of refrigerant into the inlet header (in-line, parallel and cross flow) and inlet quality (0.1, 0.2 and 0.3). It was found that the orientation of the header had relatively large effect on the flow distribution and phase separation, while the inlet quality didn't affect much on them. The horizontal header showed the better flow distribution and phase separation characteristics than the vertical one. The parallel flow condition with the horizontal header showed the best performance for the flow distribution and phase separation characteristics under the test conditions. Two-phase pressure drops through the microchannel tubes with the horizontal header were higher than those of the microchennel tubes with the vertical header due to gravitational effect.

볼트체결방식의 IP-2형 운반용기의 낙하예비시험 (A Preliminary Drop Test of a Type IP-2 Transport Package with a Bolted Lid Type)

  • 김동학;서기석;박홍윤;이경호;윤정현;이흥영
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 추계 학술대회 논문집
    • /
    • pp.339-347
    • /
    • 2005
  • IP-2형 운반용기는 정상운반조건의 낙하시험을 거친 후에 방사성내용물의 유실 또는 분산이 없고 외부표면에서의 방사선량률이 $20\%$ 이상 증가할 수 있는 차폐능력의 상실이 없어야 한다. 차폐체의 두께가 큰 경우에는, 볼트체결방식을 사용하면 IP형 운반용기로 많이 사용되고 있는 ISO 컨테이너에서의 문을 사용하는 경우보다 방사성내용물의 유실 또는 분산이 일어나지 않을 것이다. 본 연구에서는 볼트체결방식의 IP-2형 운반용기에 대한 낙하시험을 실시하기 전에, 낙하방향에 따른 볼트인장력과 볼트체결력을 시험으로 평가하는 방법을 알아보기 위하여 예비시험모델을 제작하여 시험 및 평가하였다. 바닥과 뚜껑방향의 수직낙하, 수평낙하, 4방향의 경사낙하 등 총 7가지 낙하방향으로 자유낙하를 실시하였다. 낙하충격에 의한 볼트인장력은 힘센서를 이용하여 측정하였고, 볼트체결력은 낙하시험 전의 체결토르크에서 낙하충격 이후의 풀림토르크의 변화를 이용하여 알아보았다.

  • PDF

Pressure drop in packed beds with horizontally or vertically stratified structure

  • Li, Liangxing;Xie, Wei;Zhang, Zhengzheng;Zhang, Shuanglei
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2491-2498
    • /
    • 2020
  • The paper concentrates on an experimental study of the pressure drop in double-layered packed beds formed by glass spheres, having the configuration of horizontal and vertical stratification. Both single-phase and two-phase flow tests are performed. The pressure drop during the test is recorded and the measured data are compared with those of homogeneous beds consisting of mono-size particles. The results show that for the horizontally stratified bed with fine particles atop coarse particles, the pressure drop in top layer is found higher than those of homogenous bed consisting of the same smaller size particles, while the measured pressure drop of bottom part is similar with those of similar homogenous bed. But for the homologous bed with upside-down structure, the stratification has little or no effect on the pressure drop of the horizontally stratified bed, and the pressure drop of each layer is almost same as that of homogeneous bed packed with corresponding spheres. Additionally, in vertically stratified bed, the pressure drops on the left and right side is almost equal and between those in homogeneous beds. It is speculated that vertically stratified structure may lead to lateral flow which redistributes the flow rate in different parts of packed bed.

RC조 건축물의 구조시스템에 따른 수직진동 전달 특성 비교 (Characteristics of Vertical Vibration Transfer according to RC Structure Systems)

  • 전호민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.196-201
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures and the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the heel-drop excitation experiments were conducted several times on the two type building structures. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vortical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces and are effected the shear wall on the path of the vibration transfer.

  • PDF

여자 체조선수들의 드롭 랜딩 시 체조화 착용유무가 전방십자인대 부상 위험요인에 미치는 영향 (Effects of Gymnasts Shoes on Risk Factors of Anterior Cruciate Ligament Injuries during Drop Landing in Female Gymnasts)

  • 임비오;류영;김규완
    • 한국운동역학회지
    • /
    • 제23권3호
    • /
    • pp.219-223
    • /
    • 2013
  • The purpose of the study was to investigate the effects of gymnasts shoes on risk factors of anterior cruciate ligament injuries during drop-landing followed by vertical jump in female gymnasts. Thirteen female gymnasts were recruited and performed randomly drop-landing followed by vertical jump in height of her knee with and without shoes. Kinematics and ground reaction data were collected to estimate the anterior cruciate ligament injuries risk factors. Data were analyzed with paired samples t-test with Bonferroni correction. Female gymnasts with shoes showed more reduced thigh maximum adduction angle, and knee maximum extension moment than without shoes. Female gymnasts with shoes showed more increased shank maximum abduction angle than without shoes. In conclusion, Female gymnasts with shoes reduced anterior cruciate ligament injuries risk factors.

Landing with Visual Control Reveals Limb Control for Intrinsic Stability

  • Lee, Aeri;Hyun, Seunghyun;Ryew, Checheong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제12권3호
    • /
    • pp.226-232
    • /
    • 2020
  • Repetition of landing with visual control in sports and training is common, yet it remains unknown how landing with visual control affects postural stability and lower limb kinetics. The purpose of this study was to test the hypothesis that landing with visual control will influence on lower limb control for intrinsic dynamic postural stability. Kinematics and kinetics variables were recorded automatically when all participants (n=10, mean age: 22.00±1.63 years, mean heights: 177.27±5.45 cm, mean mass: 73.36±2.80 kg) performed drop landings from 30 cm platform. Visual control showed higher medial-lateral force, peak vertical force, loading rate than visual information condition. This was resulted from more stiff leg and less time to peak vertical force in visual control condition. Leg stiffness may decrease due to increase of perturbation of vertical center of gravity, but landing strategy that decreases impulse force was shifted in visual control condition during drop landing. These mechanism explains why rate of injury increase.

프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가 (Performance Evaluation of Vertical Vibration of Precast Concrete Slabs)

  • 허석재;이상현;조승호;정란;김성배;박성순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF