• 제목/요약/키워드: Vertical deviation

검색결과 290건 처리시간 0.029초

골연골종으로 인한 과두절제 후 하악지 수직 골절단술 및 bone sliding을 통한 즉시 재건: 증례보고 (IMMEDIATE RECONSTRUCTION USING VERTICAL RAMUS OSTEOTOMY AND BONE SLIDNG AFTER CONDYLECTOMY DUE TO OSTEOCHONDROMA: A CASE REPORT)

  • 장지영;오제경;차두원;백상흠
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권3호
    • /
    • pp.233-240
    • /
    • 2007
  • Osteochondroma is a common benign tumor of the axial skeleton, especially the distal metaphysis of the femur and proximal metaphysis of the tibia. However, it occurred rarely on the facial skeleton. The coronoid and condylar processes have been considered to be the most common sites of occurrence for osteochondroma of the facial skeleton. The first treatment of osteochondroma is condylectomy, whereas extirpation was done by excision with condyle salvage. Condylectomy presents decrease of vertical dimension, jaw deviation, malocclusion. So, reconstruction is need. Methods of reconstruction are as follows: no reconstruction, condyloplasty, discectomy, costochondral graft, discplication or coronoidectomy, eminoplasty, alloplastic spacer placement, Le Fort I level maxillary osteotomy, extraoral and intraoral vertical ramus osteotomy. This is a case report of a 28-year old woman who had facial asymmetry, malocclusion and temporomandibular joint pain. We obtained moderate functional and cosmetic results with surgical removal of the osteochondroma by condylectomy and concomitant reconstruction of condyle by vertical ramus osteotomy with sliding technique.

마이크로컬럼 어레이에 적용 가능한 웨이퍼단위의 수직 배선 방법 (Wafer level vertical interconnection method for microcolumn array)

  • 한창호;김현철;강문구;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.793-796
    • /
    • 2005
  • In this paper, we propose a method which can improve uniformity of a miniaturized electron beam array for inspection of very small pattern with high speed using vertical interconnection. This method enables the individual control of columns so that it can reduce the deviation of beam current, beam size, scan range and so on. The test device that used vertical interconnection method was fabricated by multiple wafer bonding and metal reflow. Two silicon and one glass wafers were bonded and metal interconnection by melting of electroplated AuSn was performed. The contact resistance was under $10{\Omega}$.

  • PDF

GPS 관측 자료를 이용한 대기 수증기 연직 분포 추정 (Estimation of Water Vapor Vertical Profiles in the Atmosphere Using GPS Measurements)

  • 하지현;박관동
    • 대기
    • /
    • 제19권3호
    • /
    • pp.289-296
    • /
    • 2009
  • Measurements of the three-dimensional water vapor distribution in the atmosphere are important for forecast and analysis of meteorological phenomenon. In this study, two Global Positioning System (GPS) campaign networks were installed in Jeju Island and Kangwon-do to construct the vertical water vapor profile solely based on GPS measurements. We implemented a layer model to get the wet refractivity profile and compared the result with radiosonde measurements. The result showed that the vertical profiles from GPS and radiosonde agree well. The bias, root-mean-square error (RMSE) and standard deviation of GPS wet refractivities compared with radiosonde measurements were in the range of 6.6~11.1 mm $km^{-1}$, 11.9~13.9 mm $km^{-1}$, and 4.3~12.3 mm $km^{-1}$, respectively.

사회심리적 스트레스 및 작업특성 요인이 직업성요통에 미치는 영향 (The Effects of Psychosocial Stress and Job Characteristics on Low Back Injury)

  • 허국강;박동현
    • 대한인간공학회지
    • /
    • 제19권2호
    • /
    • pp.15-31
    • /
    • 2000
  • The aim was to evaluate the prevailing ergonomic and psychosocial conditions regarding low back injury in an automobile assembly system. This study consisted of two parts. In the first part of the study, analytic biomechanical model and NIOSH guidelines were applied to evaluate risk levels of low back injury for automobile assembly jobs. Total of 246 workers were analysed. There were 20 jobs having greater back compressive forces than 300kg at L5/S1. Also, there were 44 jobs over Action Limit with respect to 1981 NIOSH guidelines. This might in part be explained by the ergonomic conditions of the company analysed generally being good, with a relatively low duration of 'combined' extreme work posture. The relationship between psychosocial factors and low back injury was examined in the second part of the study. It has recently been recognized that overall reaction to working conditions was influenced by a range of factors, some of which were physical and some psychosocial. The psychosocial environment surrounding the work place may contribute to the perception of risk and eventual ill-health. A battery of questionnaires concerning the psychosocial stress based on PWI(Psychosocial Well-being Index) and musculoskeletal pain symptoms at low back was completed by 246 workers at the same plant. Results showed that 207 out 246 workers experienced the symptoms and 27 workers were diagnosed as patients. Two groups(low stressed, high stressed) based on PWI score had no significant relationships with both symptoms and results of diagnosis. However, sensitivities for symptoms and diagnosis by PWI were 91.3% and 92.6% respectively. Finally, relationships between physical work load and psychosocial stress were analysed. Specifically, some postural factors {vertical deviation angle of forearm, horizontal deviation angle of upperarm, vertical deviation angle of thigh, etc) were highly correlated with psychosocial stress. The results illustrated that PWI scores were associated with some physical workloads. However, psychosocial stress levels couldn't be well related with the pain symptom as well as the actual incidence of low back injury since pain or discomfort regarding low back injury were more complex than that of other musculoskeletal disorders.

  • PDF

지하수면 위의 LNAPL 이동을 고려한 용질이동에 대한 분석 (Analyses on Solute Transport with the Movement of an LNAPL on the Water Table)

  • 김지훈;최종근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2003
  • 지하 유류저장탱크에서 유류가 지속적으로 누출되는 경우에는 지하수 이동에 비해서 LNAPL의 이동을 무시할 수 없다. 본 연구에서는 지하수면 위에서 LNAPL의 이동을 고려한 수정된 용질이동 모델을 개발하였다 LNAPL 이동을 고려하지 않는 기존 모델과 비교한 결과 수두 구배, 누출되는 기름의 양, 분산지수에 따라 두 모델은 차이점을 보였다. 수두 구배가 낮을수록, 누출되는 유류의 양이 증가할수록 수정된 모델과 기존 모델 사이의 평균편차가 증가하였다. 분산지수가 변화함에 따라서 평균편차는 변하지 않았지만, 분산지수가 증가할수록 두 모델 사이의 편차는 공간적으로 보다 넓게 나타났다. 수직방향으로의 분산이 크게 나타날 경우에는 LNAPL의 이동을 고려한 모델과 이동을 고려하지 않은 모델과의 차이가 지하수 유동 방향뿐만 아니라 수직방향으로도 크게 나타났다. 결국 LNAPL의 이동을 무시할 수 없는 지하환경에서는 기존의 모델을 가지고 용질이동을 모사할 경우 실제보다 농도가 낮게 추정될 가능성이 높다. 이 연구의 결과로 LNAPL이 지하수면 위에서 얼마나 빨리 이동하는지 아는 것이 올바른 오염물의 농도 예측에 중요하다는 것을 파악하였다.

Relationship between chin deviation and the position and morphology of the mandible in individuals with a unilateral cleft lip and palate

  • Kim, Kyung-Seon;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.168-177
    • /
    • 2013
  • Objective: In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods: Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results: For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions: UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance.

요추디스크 수핵감압술을 위한 투시영상의 교정 (Correction of Fluoroscopic Image for Nucleoplasty in Lumbar Disc)

  • 윤영우;강세식;최석윤
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.359-365
    • /
    • 2016
  • 투시조영촬영은 인체 내부의 조직이나 장기를 검사할 때 시행하며 특히 척추 질환의 진단 및 시술에 사용된다. 영상증배관(image intensifier tube)을 사용하는 투시조영 촬영장비는 영상에서 중심부보다 주변부에 왜곡이 나타난다. 본 연구에서는 교정 알고리즘을 적용하여 교정전과 교정후의 수직길이비 왜곡비율과 대각길이비의 왜곡비율을 측정하였다. 수직길이비의 측정결과는 교정후의 표준편차가 교정전보다 0.04감소하였고 대각길이비의 측정결과는 교정후의 표준편차가 교정전보다 0.06감소하여 교정 후 투시영상의 왜곡이 감소되었다. 향후 교정 알고리즘의 적용과 성능향상을 통해서 영상왜곡을 감소시키면 요추디스크의 치료를 위한 수핵감압술시 요추천자의 정확한 위치를 찾는데 도움을 줄 것으로 사료된다.

Benefits of lateral cephalogram during landmark identification on posteroanterior cephalograms

  • Hwang, Sel-Ae;Lee, Jae-Seo;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • 대한치과교정학회지
    • /
    • 제49권1호
    • /
    • pp.32-40
    • /
    • 2019
  • Objective: Precise identification of landmarks on posteroanterior (PA) cephalograms is necessary when evaluating lateral problems such as facial asymmetry. The aim of the present study was to investigate whether the use of lateral (LA) cephalograms can reduce errors in landmark identification on PA cephalograms. Methods: Five examiners identified 16 landmarks (Cg, N, ANS, GT, Me, RO, Lo, FM, Z, Or, Zyg, Cd, NC, Ms, M, and Ag) on 32 PA cephalograms with and without LA cephalograms at the same time. The positions of the landmarks were recorded and saved in the horizontal and vertical direction. The mean errors and standard deviation of landmarks location according to the use of LA cephalograms were compared for each landmark. Results: Relatively small errors were found for ANS, Me, Ms, and Ag, while relatively large errors were found for N, GT, Z, Or, and Cd. No significant difference was found between the horizontal and vertical errors for Z and Or, while large vertical errors were found for N, GT, and Cd. The value of identification error was lower when the landmarks were identified using LA cephalograms. Statistically significant error reductions were found at N and Cd with LA cephalograms, especially in the vertical direction. Conclusions: The use of LA cephalograms during identification of landmarks on PA cephalograms could help reduce identification errors.

Effects of Fatigue Induction on Ground Reaction Force Components, Postural Stability, and Vertical Jump Performance in Taekwondo Athletes

  • Hyun, Seung-Hyun;Kim, Young-Pyo;Ryew, Che-Cheong
    • 한국운동역학회지
    • /
    • 제26권2호
    • /
    • pp.143-151
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of fatigue induction on ground reaction force (GRF) components, postural stability, and vertical jump performance in Taekwondo athletes. Method: Ten Taekwondo athletes (5 men, 5 women; mean age, $22.30{\pm}2.62years$; mean height, $174.21{\pm}9.20cm$; mean body weight, $67.28{\pm}12.56kg$) participated in this study. Fatigue was induced by a short period of strenuous exercise performed on a motorized treadmill. The analyzed variables included vertical jump performance, static stability (mediolateral [ML], center of pressure [COP], anteroposterior [AP] COP, ${\Delta}COPx$, ${\Delta}COPy$, and COP area), postural stability index values (ML stability index [MLSI], AP stability index [APSI], vertical stability index [VSI], dynamic postural stability index [DPSI]), and GRF components (ML force, AP force, peak vertical force [PVF], and loading rate). To analyze the variables measured in this study, PASW version 22.0 was used to calculate the mean and standard deviation, while a paired t-test was used to evaluate the pre- versus post-fatigue results. Pearson's correlation coefficients among variables were also analyzed. The statistical significance level was set at ${\alpha}$ = .05. Results: Vertical jump performance decreased significantly after the induction of fatigue, while AP COP, ${\Delta}COPx$, COP area, APSI, VSI, and DPSI increased significantly. PVF and loading rate increased significantly after the induction of fatigue, while the postural stability variables (AP COP, ${\Delta}COPy$, COP area, APSI, VSI, DPSI) were similarly correlated with GRF components (PVF, loading rate) after fatigue was achieved (r = .600, $R^2$ = 37%). Conclusion: These results suggest that the induction of fatigue can decrease postural stability and exercise performance of Taekwondo athletes during training and competition sessions.

Differences in facial soft tissue deviations in Class III patients with different types of mandibular asymmetry: A cone-beam computed tomography study

  • Ho-Jin Kim;Hyung-Kyu Noh;Hyo-Sang Park
    • 대한치과교정학회지
    • /
    • 제53권6호
    • /
    • pp.402-419
    • /
    • 2023
  • Objective: This study assessed the differences in soft tissue deviations of the nose, lips, and chin between different mandibular asymmetry types in Class III patients. Methods: Cone-beam computed tomography data from 90 Class III patients with moderate-to-severe facial asymmetry were investigated. The sample was divided into three groups based on the extent of mandibular rolling, yawing, and translation. Soft tissue landmarks on the nose, lips, and chin were investigated vertically, transversely, and anteroposteriorly. A paired t test was performed to compare variables between the deviated (Dv) and nondeviated (NDv) sides, and one-way analysis of variance with Tukey's post-hoc test was performed for intergroup comparisons. Pearson's correlation coefficient was calculated to assess the relationship between the soft and hard tissue deviations. Results: The roll-dominant group showed significantly greater differences in the vertical positions of the soft tissue landmarks between the Dv and NDv than other groups (P < 0.05), whereas the yaw-dominant group exhibited larger differences in the transverse and anteroposterior directions (P < 0.05). Moreover, transverse lip cant was correlated with the menton (Me) deviation and mandibular rolling in the roll-dominant group (P < 0.001); the angulation of the nasal bridge or philtrum was correlated with the Me deviation and mandibular yawing in the yaw-dominant group (P < 0.01). Conclusions: The three-dimensional deviations of facial soft tissue differed based on the mandibular asymmetry types in Class III patients with similar amounts of Me deviation. A precise understanding of soft tissue deviation in each asymmetry type would help achieve satisfactory facial esthetics.