• 제목/요약/키워드: Vertical Test Stand

검색결과 24건 처리시간 0.026초

입형펌프의 공진회피와 안전성 평가 (Resonance avoidance and Safety Evaluation of Vertical Pump)

  • 정우영;송진대
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.698-702
    • /
    • 2013
  • This paper considers the vertical pumps resonance and soundness. Normally large vertical pump's rotating speed is low, so the low natural mode can make a resonance on the motor and motor stand assembly. The pump resonance makes a very high vibration and trouble on the pump systems. Thus to avoid pump resonance when the pump is on the resonance region, we give the added mass method and evaluate the structure soundness by computer simulation and test on the site. Furthermore we evaluate the modal sensitivity and expect running conditions by the using ISO10814.

  • PDF

앉은 자세에서 일어서기(Sit to stand)과제의 동작시간과 지면반발력 분석 (The Analysis of Movement time and Ground Reaction Force during Sit to Stand Task in Healthy)

  • 김수민
    • PNF and Movement
    • /
    • 제9권1호
    • /
    • pp.31-38
    • /
    • 2011
  • Purpose : Sit-to-stand (STS) is one of the important activities of daily living (ADL) and each of its parameters is used frequently. This study aimed to examine the influence of different seat height on performance time and floor reaction force strength during an STS movement. Methods : Fifteen young-adult male subjects participated in this study. The subjects were divided into three groups based on lower leg length. Subjects performed an STS movement twice from chairs at height adjusted by the lower leg length of each subject. To examine the influence of the chair seat height, ground reaction forces during a STS performed with 3 chair heights adjusted to each subjects lower leg length were compared. Results : Vertical ground reaction force and time during an STS movement were measured to evaluate. Parameters regarding ground reaction force were selected for analyses. Significant differences were found in ground reaction force at G1 was greater than G2 and G3. Conclusion : The STS movement achievement strategy differed since chair seat height changes relatively by the difference in lower leg length. When conducting the ability to achieve STS movement rating test, chair seat height considering each subject's lower leg length may be needed.

Wii Balance Board를 이용한 Sit-to-Stand와 보행기능 측정의 검사-재검사 신뢰도 (Test-retest Reliability of Sit-to-Stand and Gait Assessment Using the Wii Balance Board)

  • 양승례;오유리;전예림;박대성
    • 한국전문물리치료학회지
    • /
    • 제23권3호
    • /
    • pp.40-47
    • /
    • 2016
  • Background: Assessments of Sit-to-Stand (STS) and gait functions are essential procedures in evaluating level of independence for the patients after stroke. In a previous study, we developed the software to analyze center of pressure (COP) in standing position on Wii Balance Board (WBB). Objects: This purpose of this study is to measure test-retest reliability of ground reaction forces, COP and time using WBB on STS and gait in healthy adults. Methods: Fifteen healthy participants performed three trials of STS and gait on WBB. The time (s), vertical peak (%) and COP path-length (cm) were measured on both tasks. Additionally, counter (%), different peak (%), symmetry ratio, COP x-range and COP y-range were analyzed on STS, 1st peak (%), 2nd peak (%) of weight were analyzed on gait. Intra-class correlation coefficient (ICC), standard error measurement (SEM) and smallest real difference (SRD) were analyzed for test-retest reliability. Results: ICC of all variables except COP path-length appeared to .676~.946 on STS, and to .723~.901 on gait. SEM and SRD of all variables excepting COP path-length appeared .227~8.886, .033~24.575 on STS. SEM and SRD excepting COP path-length appeared about .019~3.933, .054~11.879 on gait. Conclusion: WBB is not only cheaper than force plate, but also easier to use clinically. WBB is considered as an adequate equipment for measuring changes of weight bearing during balance, STS and gait test which are normally used for functional assessment in patients with neurological problems and elderly. The further study is needed concurrent validity on neurological patients, elderly patients using force plate and WBB.

교량진동을 이용한 진동형 자가발전기에 대한 연구 (A Study on Stand-Alone Electric Power Generator Using Bridge Vibration)

  • 최남섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.313-316
    • /
    • 2003
  • 본 논문에서는 교량의 건전도 감시용 계측 유닛에 사용되는 충전시스템을 위한 교량의 상시진동을 이용한 자립형 진동발전기에 대하여 연구하였다. 본 연구에서는 전기자 반작용의 영향을 최소화한 진동발전기를 제안하고, 기계적 및 전기적인 설계식을 유도한 다음, 시험용 진동발전기를 제작하였다. 아울러, 실내 자유진동 실험을 수행하였고, 축전시스템에 대한 실험 결과, 정류기에 사용된 다이오드 특성이 충전과정에서 지배적임을 확인하였다. 또한, 남해대교의 진동 데이터를 Pilot 발전기에 적용하여 시뮬레이션 한 결과 진동발전기의 적용성과 효용성을 확인할 수 있었다.

  • PDF

소형 풍력발전시스템의 출력성능검사 (Power performance Testing of Small Wind Turbine Generator System)

  • 김현기;김병민;유능수
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.123-128
    • /
    • 2011
  • In this study, procedures, a power performance testing system of Wind Turbine System Research Center of Kangwon National University is introduced. Test prodedures and results are presented on a stand-alone vertical-axis 200W wind turbine manufactured by Geum-Poong Energy Inc.. Power performance test is performed according to IEC standard. The test results are compared with the power performance standard. Also, the effects of normalization and disturbed sectors are considered.

  • PDF

The Effects of Squat Exercises with Vertical Whole-Body Vibration on the Center of Pressure and Trunk Muscle Activity in Patients with Low Back Pain

  • Kang, Jeongil;Jeong, Daekeun;Choi, Hyunho
    • 국제물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.2253-2260
    • /
    • 2020
  • Background: Patients with low back pain (LBP) experience misalignments in the center of pressure (COP) and muscle imbalances due to frequent onesided posture adjustments to avoid pain. Objectives: To identify the effects of Squat Exercises with Vertical Whole-Body Vibration on the Center of Pressure and Trunk Muscle Activity. Design: Randomized controlled trial. Methods: Thirty LBP patients with an imbalance in the COP were sampled and randomly assigned to an experimental group of 15 patients who under went an intervention involving squat exercises with vertical WBV and a control group of 15 patients who were treated via a walking intervention. As pretests before the interventions, the subjects' COP was identified by measuring their stability index (ST), and erector spinae, rectus abdominis, transverse abdominis, gluteus medius muscle activity was analyzed by determining the % reference voluntary contraction (%RVC) value using surface electromyography while sit to stand. After four weeks, a post test was conducted to remeasure the same variables using the same methods. Results: Statistically significant differences were found in the ST (P<.01) and trunk muscle (P<.05, P<.001) in the experimental group before and after the intervention. In terms of the differences between the left- and right-side (RL) muscle activity, only the transverse abdominis (TrA) and gluteus medius (GM) exhibited statistically significant increase (P<.05). A comparison of the groups showed statistically significant differences in the TrA with respect to muscle activity (P<.05) and in the RLTrA and RLGM in terms ofthe difference between left- and right-side muscle activity (P<.01). Conclusion: Squat exercises with vertical WBV produced effective changes in the COP of patients with LBP by reducing muscle imbalances through the delivery of a uniform force. In particular, strengthening the TrA and reducing an imbalance in the GM were determined to be important factors in improving the COP.

Design and test result of a superconducting double-spoke cavity

  • Jiang, Tiancai;Huang, Yulu;Zhang, Shengxue;Liu, Lubei;Xiong, Pingran;Li, Chunlong;Guo, Hao;Yue, Weiming;Zhang, Shenghu;He, Yuan
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.877-883
    • /
    • 2019
  • Superconducting multi-spoke cavities are outstanding alternative choice for acceleration of heavy ions in medium velocity regimes. Based on the scheme of China ADS, several researches on the superconducting double-spoke cavities were done and two prototype cavities have been developed. In this paper, the RF design, the mechanical design and fabrication considerations of the bare cavity will be described in detail. After Buffered Chemical Polishing and High Pressure Rinsing, one of the prototype cavities was installed into the Vertical Test Stand for high gradient RF testing at 4.2 K. The measurement results of the quality factor as a function of the accelerating field and the maximum surface field will be presented. An accelerating gradient of more than 15 MV/m is achieved during the test, with maximum surface electric field of 58 MV/m, and maximum surface magnetic field of 117 mT.

초고강도 ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$) P.C Bearing Plate 개발에 관한 연구 (A Study on the Development of a Ultra-Strength Precast Concrete Bearing Concrete Bearing Plate)

  • 소현창;정병욱;김재우;문성규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.643-648
    • /
    • 1997
  • P.C Bearing Plate method, corresponding to the existing steel plate build-up method, is developed by the very first in domestic and is applied to the foundation in the HYUNDAI building at Kang-Nam. P. C Bearing Plate produced in ourself P.C plant can stand against vertical load of 7,000ton obtaining allowable force of soil. It is possible to minmize cost expediting, do site assembling and omit unnecessary excavation work by plant prefabrication of foundation member. The purpose of this paper is to study the optimum mixing design of Ultra-high strength concrete ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$), crack control through measuring the heat of hydration, mock up test for the optimum curing method. As mentioned above, developing the Ultra-high strength Precast Concrete Bearing Plate set up successfully in the site foundation work of the HYUNDAI Building at Kang-Nam.

  • PDF

온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구 (Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.82-88
    • /
    • 2010
  • 건축 구조물의 주요 구조부는 중력하중의 전달과 수평하중을 견디도록 설계, 시공되어야 함을 물론이고, 화재의 고열환경에서 부수적으로 발생되는 온도에 의한 추가하중을 지지하도록 설계되어야 한다. 강구조 건축물에서의 보부재는 중력 및 횡력 방향의 하중에 더 강한 지지력을 확보하기 위하여 H형강 웨브부분에 콘크리트를 충전하는 타입의 개발 및 적용이 이루어져 왔으나, 내화성능의 평가는 거의 이루어지지 않은 상태이다. 따라서 본 논문에서는 H형강 보부재의 웨브에 일반강도의 콘크리트로 충전된 시험체를 대상으로 열전도 해석에 의한 내화성능과 재하가열시험을 통한 내화성능을 각각 제시하고 상관성을 비교분석하였다.

유체간섭을 동반하는 헬륨과 공기의 치환류 (Helium-Air Exchange Flow with Fluids Interaction)

  • T.I. Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.372-380
    • /
    • 1997
  • This paper describes experimental investigations of helium-air exchange flows through parti¬tioned opening and two-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with the two types of small open¬ing on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. In the case of exchange flow through the partitioned opening, flow passages of upward flow of the helium and downward flow of the air within the opening are separated by vertical partition, and the two flows interact out of entrance and exit of the opening. Therefore, an experiment of the exchange flow through two-opening is made to investigate effect of the fluids interaction of the partitioned opening sys¬tem. As a result of comparison of the exchange flow rates between the two types of the opening system, it is found that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system due to absence of the effect of fluids interaction. Finally, the fluids interaction between the upward and downward flows through the partitioned opening is found to be an important factor on the helium-air exchange flow.

  • PDF