• Title/Summary/Keyword: Vertical Strip

Search Result 135, Processing Time 0.02 seconds

Drag Reduction in Turbulent Channel flow with Periodically Arrayed Heating and Cooling Strips (난류 채널 내 냉·열판 부착에 의한 마찰저항 감소)

  • Yoon, Hyun-Sik;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.608-618
    • /
    • 2005
  • A new technique giving significant drag reduction in turbulent shear flows has been proposed by using the buoyancy effect to generate periodic spanwise motion. Such spanwise motion can be obtained by arranging heating and cooling strips periodically aligned in the spanwise direction of a vertical channel, where the streamwise mean flow is perpendicular to the gravity vector The strip size has been changed in order to obtain the optimum size corresponding to the maximum drag reduction. The bulk Reynolds number, $ Re_{m} = U_{m} \delta / \nu \$ is fixed at 2270 while Grashof numbers is changed between $10^{6}$ to $10^{7}$. As Grashof number increases, considerable drag reduction can be obtained, At the highest Grashof number, an optimum strip size of about 250 wail units gives drag reduction of about 35$\%$. The greater the Grashof number, the smaller the strip size attains the maximum drag reduction.

Boiling Heat Transfer in a Narrow Rectangular Channel with Offset Strip Fins (오프셋 스트립 휜이 있는 협소 사각유로의 비등열전달)

  • Kim Byong Joo;Jeong Eun Soo;Sohn Byong Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.977-983
    • /
    • 2004
  • An experimental study on saturated flow boiling heat transfer of R113 was peformed in a vertical narrow rectangular channel with offset strip fins. Two-phase pressure gradients and boiling heat transfer coefficients in an electrically heated test section were measured in the range of quality $0{\sim}0.6$, mass flux $17{\sim}43kg/m^{2}s$, and heat flux of $500{\sim}3,000W/m^2$ Two-phase friction multipliers were determined as a function of Lockhart-Martinelli parameter. Local boiling heat transfer coefficients were analysed in terms of mass flux, heat flux and local vapor quality. Correlation for boiling heat transfer coefficients was proposed, which was in good agreement with experimental data.

Failure pattern of twin strip footings on geo-reinforced sand: Experimental and numerical study

  • Mahmoud Ghazavi;Marzieh Norouzi;Pezhman Fazeli Dehkordi
    • Geomechanics and Engineering
    • /
    • v.32 no.6
    • /
    • pp.653-671
    • /
    • 2023
  • In practice, the interference influence caused by adjacent footings of structures on geo-reinforced loose soil has a considerable impact on their behavior. Thus, the goal of this study is to evaluate the behavior of two strip footings in close proximity on both geocell and geogrid reinforced soil with different reinforcement layers. Geocell was made from geogrid material used to compare the performance of cellular and planar reinforcement on the bearing pressure of twin footings. Extensive experimental tests have been performed to attain the optimum embedment depth and vertical distance between reinforcement layers. Particle image velocimetry (PIV) analysis has been conducted to monitor the deformation, tilting and movement of soil particles beneath and between twin footings. Results of tests and PIV technique were verified using finite element modeling (FEM) and the results of both PIV and FEM were used to utilize failure mechanisms and influenced shear strain around the loading region. The results show that the performance of twin footings on geocell-reinforced sand at allowable and ultimate settlement ranges are almost 4% and 25% greater than the same twin footings on the same geogrid-reinforced sand, respectively. By increasing the distance between twin footings, soil particle displacements become smaller than the settlement of the foundations.

Numerical assessment of rectangular one- and two-way RC slabs strengthened with CFRP under impact loads

  • Mohamed Emara;Ahmed Hamoda;Jong Wan Hu
    • Computers and Concrete
    • /
    • v.31 no.3
    • /
    • pp.173-184
    • /
    • 2023
  • In this study, the flexural behaviors of one- and two-way reinforced concrete (RC) slabs strengthened with carbon-fiber-reinforced polymer (CFRP) strips under impact loads were investigated. The flexural strengthening of RC slabs under simulated static monotonic loads has been comprehensively studied. However, the flexural behavior of RC slabs strengthened with CFRP strips has not been investigated extensively, particularly those conducted numerically. Nonlinear three-dimensional finite element models were developed, executed, and verified against previous experimental results, producing satisfactory models with approximately 4% error. The models were extended to a parametric study, considering three geometric parameters: the slab rectangularity ratio, CFRP strip width, and CFRP strip configuration. Finally, the main results were used to derive a new formula for predicting the total deflection of RC slabs strengthened with CFRP strips under impact loads with an error of approximately 10%. The proposed equation reflected the slab rectangularity, CFRP strip width, equivalent slab stiffness, and dropped weight. Results indicated that the use of CFRP strips enhanced the overall impact performance, the wider the CFRP width, the better the enhancement. Moreover, the application of diagonally oriented CFRP strips diminished the cracking zone compared to straight strips. Additionally, the diagonal orientation of CFRP strips was more efficient for two-way slabs while the vertical orientation was found to be better in the case of one-way slabs.

Accident Reduction Effect of Rumble Strips by Highway Geometric Characteristics (도로 선형특성에 따른 럼블스트립의 교통사고 감소효과)

  • Oh, Heung-Un
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3D
    • /
    • pp.289-294
    • /
    • 2010
  • It is well known that rumble strips contribute to reduce traffic accidents. The present paper provides the reduction effect of traffic accidents under specific highway geometrics after rumble strip installation. Traffic accidents on freeway sections before and after rumble strip installation are compared when conditions of the highway geometric characteristics such as horizontal, vertical geometrics are given. It is shown that rumble strips are effective under highway geometric conditions of down slopes or right curvatures. It is also shown that rumble strips are still effective with shorter length of installation.

Deformation Behavior of Slab by Two-Step Sizing Press in a Hot Strip Mill (열간 압연에서 2단 사이징 프레스 금형에 의한 슬래브의 변형거동 예측)

  • Lee S. H.;Kim D. H.;Byon S. M.;Park H. D.;Kim B. M.
    • Transactions of Materials Processing
    • /
    • v.14 no.9 s.81
    • /
    • pp.791-797
    • /
    • 2005
  • Extensive width reduction of slabs is an important technology for achieving continuous production between the steelmaking and hot rolling processes. However, the vertical horizontal rolling process has many disadvantages, e.g., large width deviations and less efficient width reduction. This study was carried out to investigate the deformation of slab by sizing press with two steps die. To do it, dog-bone and camber are discussed in width sizing process considering the deformation behavior according to the deviation of anvil velocity and the deviation of initial slab temperature. In this paper, the various causes of the sizing press phenomena are mentioned for the purpose of understanding of rolling conditions. As a result, the optimal anvil shape having a minimum-forming load is obtained by FE-simulation and ANN.

Study on fatigue experiment for transverse butt welds under 2G and 3G weld positions

  • Kang, Sung-Wook;Park, Yong-Man;Jang, Beom-Seon;Jeon, Yu-Chul;Kim, Seong-Min
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.5
    • /
    • pp.833-847
    • /
    • 2015
  • Although the transverse butt weld method with ceramic backing strip has been widely used in various industrial fields for its fabricational convenience, it is rarely used in offshore industries since the fatigue strength of the weld joint has not been proved sufficiently. This study conducted fatigue tests for series of butt weld specimens with horizontal (2G) and vertical (3G) welding positions in order to verify the fatigue strength compared to S-N curve by DNV (Det Norske Veritas), IIW (International Institute of Welding) and Eurocode 3. The difference of the 2G specimens and the 3G specimens are investigated in terms of angular distortion and the effect on the fatigue strength are analyzed.

On the Springing Response of Ships with Shallow Draft and Large Breadth (천홀수 광폭선의 스프링잉 응답 해석)

  • 정종진;박인규
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.2
    • /
    • pp.55-60
    • /
    • 2004
  • This paper describes the estimation method of hull girder response of ships due to springing. To this aim, nonlinear springing effect on the hull girder is evaluated including vertical, horizontal, and torsional deformation of the hull. The Timoshenko beam model is used to calculate the stress distribution on the hull girder. The quadratic strip method is employed to calculate the hydrodynamic forces and moments on the hull. In order to remove the irregular frequencies, 'rigid lid'is adopted on the hull free surface level and hydrodynamic coefficients are interpolated for asymptotic values. The results of example calculation show a reasonable agreement with previous results for both symmetric and anti-symmetric responses.

Development of Analytical Two Dimensional Infinite Elements for Soil-Structure Interaction Analysis (지반-구조물의 상호작용 해석을 위한 해석적 2차원 무한요소)

  • 윤정방;김두기
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.19-26
    • /
    • 1997
  • In this paper, two dimensional analytical infinite elements which can include multiple wave components to model a underlying half-space are developed. Since these elements are expressed clearly and simply using Legendre polynomials of frequencies in frequency domain, these are very economical and efficient in computing the responses of strip foundations in frequency domain and are easily transformed for SSI analysis in time domain. To prove the behavior of the proposed two dimensional analytical infinite elements, vertical, horizontal, and rocking compliances of a rigid strip foundation in layered soils are analyzed and compared with those of Tzong ' Penzie $n^{(17)}$ and with those which calculated by numerical infinite elemen $t^{(1)}$ in frequency domain, and good agreements are noticed between them. As an application for a further study, a new scheme for SSI analysis in time domain are proposed and verified by comparing the displacement responses of the soil with a underlying rock due to a rectangular impulse loading with those of a soil modeled extended FE meshes.soil modeled extended FE meshes.

  • PDF

Stabilization of backfill using TDA material under a footing close to retaining wall

  • Arefnia, Ali;Dehghanbanadaki, Ali;Kassim, Khairul Anuar;Ahmad, Kamarudin
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.197-206
    • /
    • 2020
  • Reutilization of solid waste such as Tire Derived Aggregate (TDA) and mixing it with soft soil for backfill material not only reduces the required volume of backfill soil (i.e., sand-mining procedures; reinforcement), but also preserves the environment from pollution by recycling. TDA is a widely-used material that has a good track record for improving sustainable construction. This paper attempted to investigate the performance of Kaolin-TDA mixtures as a backfill material underneath a strip footing and close to a retaining wall. For this purpose, different types of TDA i.e., powdery, shredded, small-size granular (1-4 mm) and large-size granular (5-8 mm), were mixed with Kaolin at 0, 20, 40, and 60% by weight. Static surcharge load with the rate of 10 kPa per min was applied on the strip footing until the failure of footing happened. The behaviour of samples K80-G (1-4 mm) 20 and K80-G (5-8 mm) 20 were identical to that of pure Kaolin, except that the maximum footing stress had grown by roughly three times (300-310 kPa). Therefore, it can be concluded that the total flexibility of the backfill and shear strength of the strip footing have been increased by adding the TDA. The results indicate that, a significant increase in the failure vertical stress of the footing is observed at the optimum mixture content. In addition, the TDA increases the elasticity behaviour of the backfill.