• 제목/요약/키워드: Vertical Pump

검색결과 195건 처리시간 0.027초

Impact test of a centrifugal pump used in nuclear power plant under aircraft crash scenario

  • Huang, Tao;Chen, Mengmeng;Li, Zhongcheng;Dong, Zhanfa;Zhang, Tiejian;Zhou, Zhiguang
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1858-1868
    • /
    • 2021
  • Resisting an accidental impact of large commercial aircrafts is an important aspect of advanced nuclear power plant (NPP) design. Especially after the 9·11 event, some regulations were enacted, which required the design of NPPs should consider the accidental impact of large commercial aircrafts. Normal working of equipment is important for stopping reactor under an impact when an NPP is in operation. However, there is a lack of reliable analysis and research on the impact test of nuclear prototype equipment. Therefore, in order to study the response of the equipment under high acceleration impact, a centrifugal pump is selected as the research object to perform the impact test. A horizontal half-sinusoidal pulse wave was applied to the working pump. The test results show that the horizontal response of the motor and flange is greater compared to other parts, as well as the vertical response of the coupling. The stress response of the pump body support and motor support is high, hence these parts should be considered in the design of the pump. Finally, combined with the damage and stress evaluation results of the pump under different amplitudes, the ultimate impact acceleration that the pump can withstand is given.

Study on bidirectional fluid-solid coupling characteristics of reactor coolant pump under steady-state condition

  • Wang, Xiuli;Lu, Yonggang;Zhu, Rongsheng;Fu, Qiang;Yu, Haoqian;Chen, Yiming
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1842-1852
    • /
    • 2019
  • The AP1000 reactor coolant pump is a vertical shielded-mixed flow pump, is the most important coolant power supply and energy exchange equipment in nuclear reactor primary circuit system, whose steadystate and transient performance affect the safety of the whole nuclear island. Moreover, safety demonstration of reactor coolant pump is the most important step to judge whether it can be practiced, among which software simulation is the first step of theoretical verification. This paper mainly introduces the fluid-solid coupling simulation method applied to reactor coolant pump, studying the feasibility of simulation results based on workbench fluid-solid coupling technology. The study found that: for the unsteady calculations of the pure liquid media, the average head of the reactor coolant pump with bidirectional fluid-solid coupling decreases to a certain extent. And the coupling result is closer to the real experimental value. The large stress and deformation of rotor under different flow conditions are mainly distributed on impeller and idler, and the stress concentration mainly occurs at the junction of front cover plate and blade outlet. Among the factors that affect the dynamic stress change of rotor, the pressure load takes a dominant position.

복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석 (Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells)

  • 조정흠;남유진
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

수직형 지열교환기의 입.출구온도에 대한 실측과 CFD 결과 비교 (The Comparison of the EWT&LWT between Field Measurement and CFD of Vertical-type Geothermal Heat Exchanger)

  • 우상우;김중헌;신승호;황광일
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.11-16
    • /
    • 2007
  • The purpose of this study is to use the CFD(Computational Fluid Dynamics) method for the ground source heat pump(GSHP) system with vertical U-tube ground heat exchangers. In order to predict LWT(leaving water temperature) in the length of time, This simulation is used by utilizing FLUENT which is commercial CFD code. It was performed by based on four boreholes in the field. Comparing with the results of CFD and field measurement for LWT, the results of CFD was presented very good agreement with 1.0% average difference.

  • PDF

수직형 다단축의 축 정열 오프셋 자동 측정시스템 개발 (A Study on the Development of Automatic Measuring System on the Alignment Offset of the Vertical Multistage Shaft)

  • 박호철;김문영;이현
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.922-928
    • /
    • 1998
  • This paper presents the automatic alignment measuring system for improving the accuracy and working time of alignment of large vertical hydraulic pump turbine. It is general practice that rotating shaft should run within acceptable vibration limit. In order to obtain better run-out data of multi-stage rotor, careful and accurate alignment approach must be established. Generally, present alignment procedure are required several iterative works and so many manpower. Therefore, the new system has been developed using a vector calculation algorithm, laser sensor and data acquisition devices. As a result of appling to actual machines, it is confirmed that manpower is saved up to an average 90%.

  • PDF

영흥화력발전소 보일러배관 화학세정을 위한 유동검토 (Fluid-Dynamic Study for the Chemical Cleaning of Young-Heung Thermal Power Plant Boiler Pipelines)

  • 김진권;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.665-672
    • /
    • 2004
  • Chemical cleaning of boiler pipelines is necessary before the commissioning of thermal power plant after many years of construction. Fluid-Dynamic study for the chemical cleaning of boiler piplelines in Young-Heung thermal power plant is carried out. First, flow velocity necessary to sustain and exhaust solid particles in the vertical pipelines is calculated. Second, the flowrate necessary to make the calculated velocities in each vertical pipelines is calculated. Third, all the pipelines are analyzed with the Piping Systems Fluid Flow software to calculated the pressure loss in the pipelines. Finally, the operating point of the applied pump is calculated with the help of the same software.

  • PDF

발전소 순환수계통 수직펌프의 진동저감에 관한 연구 (Vibration Reduction of Vertical Pumps Used in the Power Plant Circulating Water System)

  • 박혁;유호선
    • 플랜트 저널
    • /
    • 제9권1호
    • /
    • pp.43-49
    • /
    • 2013
  • 본 연구에서는 국내 P복합발전소에서 실제 운전 중인 순환수계통 수직펌프를 대상으로 고유진동수를 측정하고, 유체와 구조가 연성된 경우의 진동이론으로부터 고진동의 원인을 파악하였다. 현장 상황에 가장 적합하며 경제적인 공진방지 대책을 선정하여 수치해석을 통해 실효성을 미리 확인한 후 실제 시스템에 적용하는 실증시험을 실시하였다.

  • PDF

흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션 (Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump)

  • 박윤철;민만기
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

Riser의 기액유동 특성에 따른 Air-lift 펌프의 성능예측 (A Prediction of the Air-lift Pump Performance by gas-liquid Flow Charac teristics of Riser)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.252-258
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to on board ship and to raise hazardous or abrasive liquids air-lift pump provides a reliable mechanism due to its simple config-uration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newto-nian liquids. it is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates and furthermore attachment of downcomer gives little effects on riser performance the conveyed liquid flow rate increases with larger submergence rate.

  • PDF

소형 수직형 축류 펌프를 위한 축방향 자기 부상 모터 (An Axial-type Self-bearing Motor for Small Vertical Axial-flow Pump)

  • 김승종
    • 한국소음진동공학회논문집
    • /
    • 제11권6호
    • /
    • pp.223-232
    • /
    • 2001
  • Aiming at a small axial pump with a levitated rotor, an axial-type self-bearing motor is presented, which has a rotor wish four permanent magnets and two stators with two-pole three-phase windings. In this system, only the axial motion of rotor is actively controlled by two opposite self-bearing motors just like in the case of an axial magnetic bearing, while the other motions are passively stable. For rotation, It follows the theory of a four-pole three-phase synchronous motor. This paper Introduces schemes for design and control of the self-bearing motor and shows some experimental results to Prove the feasibility of application for the axial Pump.

  • PDF