• Title/Summary/Keyword: Vertical Installation

Search Result 367, Processing Time 0.029 seconds

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

A numerical study for initial elastic displacement at tunnel side-wall due to configuration of the tunnel excavation (굴착단면 형상에 따른 터널 초기탄성변위의 수치해석적 연구)

  • Kim, Sang-Hwan;Jung, Hyuk-Il;Lee, Min-Sang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.175-184
    • /
    • 2002
  • Ground reaction curve is very useful information for estimating the installation time of the tunnel support. The ground reaction curve can be estimated by analytical closed form solutions derived in case of circular section and isotropic stress condition. The nature of the ground reaction, however, depends significantly on tunnel configurations. Nevertheless, few purely analytical and experimental studies of this problem due to tunnel configurations appear to have been carried out. Therefore, it is necessary to investigate the influence of tunnel configurations in order to use simply in practical design. This paper describes a numerical study for the intial elastic displacement in the ground reaction curve due to configuration of tunnel excavation. In order to evaluate the applicability of analytical closed form solution in practical design, the parametric studies were carried out by numerical analysis in elastic tunnel behaviour. In the studies, S value, namely configuration factor, defined as the ratio between tunnel height (b) and width (a), varies between 0.5 and 3.0, initial ground vertical stress varies between 5~30 MPa for each S values. The results indicated that the self-supportability of ground is larger in the ground having low S value. It, however, is suggested that the applicability of closed form solution may not be adequate to determine directly the installation time of the support and self-supportability of ground. It should be necessary to perform the additional numerical analysis.

  • PDF

A Study on Evaluation of Aircraft Rapid Arresting System Using the Numerical Analysis (수치해석을 이용한 항공기 과주방지 포장시스템의 평가방법에 관한 연구)

  • Lee, Young-Soo;Kim, Choon-Seon;Ha, Wook-Jai;Han, Jae-Hyun
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.185-195
    • /
    • 2011
  • Aircraft-related accidents cause mass casualties and major material damages. At present, runway-related accidents in our country account for 28% of all air accidents. Furthermore, internationally 33% of all air accidents is connected with runway. To prevent these accidents, FAA mandates the installation of aircraft rapid arresting system(ARAS) at the runway end safety areas which do not meet the FAA requirements. Even if the areas satisfy the conditions, FAA recommends the installation of ARAS to ensure the safety. In accordance of the international affairs, the domestic studies for ARAS are in progress and the legal formalities for domestic adoption of ARAS is under way. In this study, we analyzed the stopping distance, drag force, vertical force and tire penetration of runway overrun to assess the performance of ARAS reasonably by using two different kinds of analysis programs. The first is ARRESTOR program adopted by FAA, and the second is LS-DYNA which is available for 3-dimensional nonlineal dynamic analysis. As a result, analytically the stopping distances between two programs are similar. The drag force is rather different, but the tendencies are similar. Later on, the 3-dimensional simulation analysis considering various air-craft condition and properties of packaging materials is necessary. In addition, ongoing development of simulation analysis program is required for more accurate analistic results.

Numerical Analysis of the Effects of Stress Anisotropy and Tunnel Excavation Shape on Initial Elastic-wall Displacement (지반응력의 비등방성에 따른 터널측벽의 초기탄성변위 특성에 대한 수치해석적 연구)

  • 김상환;정혁일
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.6
    • /
    • pp.33-42
    • /
    • 2002
  • Ground reaction curve is a very important information for evaluating the side wall displacements and installation time of the tunnle support. The ground reaction curve can be estimated by analytical closed form solutions derived on the supposition of circular section and isotropic stress condition. The conditions of stress field and tunnel configurations, however, are quite different in practice. Therefore, it is necessary to investigate the effects of stress anisotropy and tunnel configurations in order to use simply in practical design. This paper describes a study of influence factors in the ground reaction curve. In order to evaluate the applicability of analytical closed form solution in practical design, two sets of parametric studies were carried out by numerical analysis in elastic tunnel behaviour: one set of studies investigated the influence of the K and the other set investigated the influence of the tunnel configurations such as circular and horse-shoe shape. In the studies, K value varies between 0.5 and 3.0, initial ground vertical stress varies between 5~30MPa far each K values. The results indicated that the self-supportability of ground is larger in the ground having lower K value. However, it is suggested that the applicability of closed form solution may not be adequate to determine directly the installation time of the support and self-supportability of ground. It is necessary to consider stress anisotropy and tunnel configurations.

Calculation of the Electromagnetic Wave Ields Near Electric Power Lines (전력선로 근방의 전자파 전자계 계산)

  • Kang, Dae-Ha;Lee, Young-Sik;Park, Jung-Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.79-88
    • /
    • 2008
  • In this study electromagnetic fields near electric power lines were derived by dipole antenna theory and electromagnetic fields near 3 phase power lines with vertical configurations were formulated and could be computed easily using these formula. It seems that those formula could be applicable to the consideration of electromagnetic fields during the design of transmission and distribution lines. Those formulated equations on elements of electromagnetic fields were applied to the model of a transmission-line system and were calculated by Matlab programs. The calculation results are follows. For variation of horizontal distance profiles of $E_y$ and $B_z$ are same each other, and also those of $B_y$ and $E_z$ are same each other. This means that coupled elements of E and B are perpendicular each other and have the propagation direction of the right-hand system such as $x{\rightarrow}E_y{\rightarrow}B_z$. Resultant electric field E is dominated by the element $E_y$ and resultant magnetic field B is dominated by the element $B_z$.

Limitation in Attraction Efficacy of Aggregation Pheromone or Plant Volatile Lures to Attract the Western Flower Thrips, Frankliniella occidentalis Infesting the Hot Pepper, Capsicum annuum, in Greenhouses (시설 고추재배지에서 꽃노랑총채벌레 집합페로몬과 식물 휘발성 유인제 효능의 한계성)

  • Kim, Chulyoung;Gwon, Gimyeon;Kim, Yonggyun
    • Korean journal of applied entomology
    • /
    • v.60 no.4
    • /
    • pp.369-377
    • /
    • 2021
  • Mass trapping of the western flower thrips, Frankliniella occidentalis, has been considered as an option to control this pest. This study applied the commercial lures to the hot pepper-cultivating greenhouses and assessed the enhancement of the attracting efficiency by adding to sticky traps. There was no color difference in the attracting efficiency between blue and yellow sticky traps. However, the installation position of the traps was crucial in the greenhouses. The more thrips were captured within host cropping area than outside areas of the crop. In vertical trap position, it was the most optimal to install the traps at the crop crown. Using these installation parameters, the yellow sticky traps captured approximately 1% population of the thrips. To enhance the trapping efficiency, the commercial lures containing aggregation pheromone or 4-methoxybenzaldehyde were added to the yellow sticky traps. However, these commercial lures did not significantly enhance the trapping efficiency compared to the yellow sticky trap alone. In contrast, Y-tube olfactometry assays confirmed the high efficiency of the aggregation pheromone or another plant volatile (methyl isonicotinate) to attract the thrips. Interestingly, these lure components had lower attracting efficiencies compared to the hot pepper flowers. The high attractive efficiency of the flowers was supported by the observation that the commercial lure was effective to enhance the trapping efficiency of the yellow sticky trap against F. occidentalis in Welsh onion (Allium fistulosum) field without any flowers. This study indicates the limitation of the commercial lures in application to hot pepper fields for the mass trapping of F. occidentalis. It also suggests active volatile component(s) from hot pepper flowers to attract F. occidentalis.

A Study on the Evaluation of Safety Stiffness from Ship's Mooring Bollards (선박 접안용 계선주의 안전 강성 평가에 관한 연구)

  • Yu, Yong-Ung;Kim, Seung-Yeon;Lee, Yun-Sok
    • Journal of Navigation and Port Research
    • /
    • v.43 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Mooring bollards are the mandatory facility in ports for they are the objects used to fasten the ship to its position at the berth. All the mooring bollards were installed following suggested sizes, numbers, materials and shape of installation according to Port and Fishing Design Standards. However, Korea has no management standard for use of mooring bollards to safety in ship berthing. In this research, the installation standard for mooring bollards including the holding power applied to mooring bollards in berthing was studied. Also, the performance of mooring bollards for minimum safety guarantee in berthing based on research of various specification by their sizes was analyzed. The analysis on mooring bollards was examined by each power on mooring bollards from the applied force in berthing divided into horizontal and vertical direction in order to examine the performance of domestic mooring bollards, the limit force is calculated based on detailed specification research result. As a result, the working stress according to the towing force was found to be at least 150Mpa and it was evaluated to be 60% of the limit strength. Also, by comparing each forces, the appropriateness was examined and the specification of maximum capability calculated. This performance evaluation method based on detail specification of mooring bollards will be expected to be useful to examine the appropriateness of mooring bollards for various types of vessel in berthing and to develop maintenance and management standard through the performance change evaluation referring to mooring bollard detailed specification changes.

Study of Structural Stability and Seismic Performances of 4-Way Sway Prevention Brace (4방향흔들림방지버팀대의 구조 안정성 및 내진 성능 연구)

  • O, Soo Un;Lee, Hang Jun;Choa, Sung Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.646-659
    • /
    • 2022
  • Purpose: In this study, we developed a 4-way sway prevention brace that efficiently reduces the installation area and has excellent stability and seismic performance compared to the conventionl sway prevention brace used in existing firefighting facilities. The performance and reliability of the developed 4-way way prevention brace were analyzed by the tensile, compression tests and seismic tests. Method: As the static test, 4-way sway prevention braces were installed on the horizontal and vertical pipes to perform the tensile and compression tests based on the KFI certification standard and the maximum movement was measured at the rated load. As a dynamic test, 4-way sway prevention braces were installed in the pipes filled with water, and the test response spectrum to the input excitation wave were measured through the acceleration sensors. After the seismic tests, separation, failure, and local deformation of the pipes, and 4-way sway prevention braces were not observed. Result: The results of the tensile and compression tests indicated that the maximum movement of the pipe during tension and compression was 50% to 70% or less compared to the certification values, indicating that the performances of the 4-way sway prevention braces were very excellent. The results of the the seismic tests indicated that the test response spectrum of the 4-way sway prevention braces is within the required response spectrum. Conclusion: In this study, it was found that the 4-way sway prevention braces satisfied the KFI certification standard and were superior compared to the existing sway prevention brace in terms of the stability, cost, and installation area.

Evaluation of the Installation Mechanism of the Micropile with the Base Expansion Structure Using a Centrifuge Model Test (원심모형실험을 활용한 선단확장형 마이크로파일의 설치 메커니즘 평가)

  • Kim, Jae-Hyun;Kim, Seok-Jung;Han, Jin-Tae;Lee, Seokhyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.11
    • /
    • pp.37-49
    • /
    • 2021
  • Micropiles are widely used in construction field to enhance bearing capacity and reduce settlement of existing foundation. It has various benefits such as low construction expense, simple installation process, and small construction equipment. Recently, new microple equipped with the base expansion structure at the end has been developed to improve the foundation bearing capacity. The improvement of load capacity can be conceptually achieved by expanding the base expansion structure when a load is applied to the micropile. However, the expansion mechanism of the base expansion structure and the improvement of load capacity of the micropile were not yet experimentally validated. Therefore, in this study, a series of centrifuge model tests was performed to evaluate the effect of the base expansion structure on the improvement of load capacity. Two types of soil, sand and weathered rock, were prepared and the loading tests were performed using the real micropile with the base expansion structure. During the tests, the earth pressures surrounding the base expansion structure were monitored. As a result, when a load of 30 kN was applied to the micropile, the increase in the ratio of the horizontal to vertical pressure increment (∆σh/∆σ𝜈) ranged from 0.4 to 0.58 in sand and ∆σh/∆σ𝜈 = 0.19 in weathered rock, respectively. Therefore, it can be concluded that the increase in the horizontal earth pressure adjacent to the base expansion structure will improve the bearing capacity of the micropile.

Characteristics of Wave Pressures According to the Installation Location of the Caisson Superstructure under Regular Waves (규칙파 조건에서 케이슨 상치구조물의 설치위치에 따른 파압 특성)

  • Jun, Jae-Hyung;Lee, Suk-Chan;Kim, Do-Sam;Lee, Kwang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.3
    • /
    • pp.82-92
    • /
    • 2022
  • In recent years, coastal and port structures have attempted to prevent wave-overtopping or provide waterfront areas by installing superstructures on the structural crowns. In general, in the design stage, the Goda formula acting on the front the structure is applied to calculate the wave pressure acting on the superstructure in consideration of the wave-runup of the design wave. However, the wave pressure exceeding the Goda wave pressure could generate depending on the installation location of the superstructure where the wave-overtopping occurs. This study analyzed the applicability of the Goda formula to the wave pressure calculation for the superstructure of the vertical structures through hydraulic model experiments and numerical simulations. Furthermore, this study investigated the magnitude of the wave pressure acting on the superstructure based on detailed numerical results. As a result, the wave pressure acting on the superstructure was up to 120% higher than the maximum wave pressure on the still water surface. In addition, the wave pressure increases exponentially with the Froude number computed by the overtopping water depth at the crown of the structure, and we proposed an empirical formula for predicting the wave pressure based on the Froude number.