• Title/Summary/Keyword: Vertical Farm

Search Result 65, Processing Time 0.033 seconds

Analysis on Heating Effects of the Vertical Type Geothermal Heat Pump System

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: This paper is aimed at analyzing the heating performance of the vertical closed loop type Geothermal Heat Pump System (GHPS) distributing the farm site and providing basic data of the GHPS. Method: Seedling greenhouse heating was made from October 2012 to May 2013. The seedling greenhouse was divided into 4 sectors (A, B, C and D zone, total $3,300m^2$) with different temperatures. It was heated from 5PM to 8AM, and during the night the greenhouse was covered by non-woven fabric thermal curtains along the upper 2m of the greenhouse for temperature maintenance. In order to analyze the heating performance of the GHPS, power consumption and operating time of the GHPS, inlet and outlet water temperature of the condenser, temperatures of each zone of the greenhouse, and ambient temperature were measured. Results: When operating only one heat pump unit, heat generated in the condenser decreased as the experiment progressed and power consumption increased correspondingly. However, the heating coefficient of performance decreased from 3.3 to 2.0 rapidly. Also, when operating two heat pump units, heat generated in the condenser decreased and power consumption increased. Heating coefficient of performance decreased from 4.5 to 3.7 rapidly. When the set temperature of the greenhouse was $13.7{\sim}20.1^{\circ}C$ and minimum ambient temperature was $-20.8{\sim}4.8^{\circ}C$, the annually accumulated heat and power consumption were 520,623 kW, 142,304 kW, respectively. Conclusion: When the set temperature of the greenhouse was $13.7{\sim}20.1^{\circ}C$ and the minimum ambient temperature was $20.8{\sim}4.8^{\circ}C$, the annually accumulated heat and power consumption were 520,623 kW, 142,304 kW, respectively. When operating only one heat pump unit, the heating COP was 2.0~3.3, and when operating 2 heat pump units, it was 3.7~4.5. If several heat pumps are installed in one GHPS, it is suggested that all heat pumps be operated except in special cases. Because the scale of the water pumps are set to the scale of when all heat pump units are operating, if even one unit is not operating, the power consumption will increase. That becomes the cause of COP decrease.

A Study on the Improvement of Dairy Rousing Systems in Kore (한국의 낙농시설 개선에 관한 연구)

  • Kim, Moon-Ki;Koh, Chae-Koon;Kim, H. U.
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.1
    • /
    • pp.31-43
    • /
    • 1982
  • Engineering phase of dairy housing systems has close connection with the milk produc- tivity of dairy cattle, the quality of milk, extension of dairy production systems, labor- saving in management of dairy cattle and the like. Moreover, the rate of investment of dairy housing facilities is of relatively high level, However, there has been almost no research effort for the improvement of engineering aspects of dairy housing systems in Korea. The purpose of this study is to find out general engineering problems and to recomm- end the improvement in dairy housing systems in Korea. Field survey by means of questionaire, direct measurements, taking pictures and sketching was conducted to get necessary information for the study. Kyung-ki Do region was firstly chosen for sampling area since it has included more than half of the number of dairy farms of the whole country. The results obtained are summarized as follows: 1. In overall dairy farm layout, the dwellings of workers were ignored in the light of sanitary environment 2. The layout of stalls in a dairy barn belongs mostly to the type of double-row face-out, which is compatible with the emphasis of manure disposal activities. 3. While the width and length of stalls were sufficiently close to the standard dimension, the width of mangers was much less than the standard dimension. 4. The width and depth of manure gutters and the width of working alleys were much. less than the standard dimension. 5. The mooring equipment was mostly in the classes of chain or rope. The watering equipment was not facilitated independantly except the one cese of using watercup. 6. The bucket milkers with one or two bucket milkers with the capacity of two cattles. each were used as milking equipment in most dairy farms. 7. There were only few milk rooms independently spaced from other space, in which the arrangement of milking equipment was much less than the standard condition. 8. The lounging ground area was averaged to be sufficient for the activity of dairy herd. 9. Silos for silage used during winter consisted of mostly bunker silos, trench silos and underground vertical silos. Ordinary vertical silos were considered for the farmers to be inconvenient for the labor saving. 10. From the view point of heat conservation and moisture removal within the dairy barns, windows were not flexible for the easy ventilation and ceiling part was not adequate for temperatur maintenance. 11. Waste treatment and disposal systems were not provided with most dairy farms, therefore the livestock waste pollution problems would be serious in the near future.

  • PDF

Estimation of Neospora caninum Seroprevalence in Dairy Cattle in Gongju and Yeongi and Transmission Pattern to Newborn Calves (공주, 연기지역 젖소의 Neospora caninum 항체 양성율 및 갓 태어난 송아지의 감염양상 조사)

  • Son, Jeong-Hoon;Park, Bae-Keun;Seo, Sang-Heui;Son, Hwa-Young;Cho, Sung-Whan;Ryu, Si-Yun
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.46-51
    • /
    • 2011
  • To examine the seroprevalence of Neospora caninum (N. caninum) infections in cattle raised at farms where an abortion had previously occurred in Gongju city and Yeongi-gun of Chungnam Province, 280 head of cattle from six farms were examined by ELISA. Thirty-two pregnant cattle from four farms were examined to determine the abortion rate in N. caninum-infected pregnant cattle and the infection pattern in newborn calves. The six farms where the abortions had previously occurred demonstrated positive reactions to N. caninum. Although the mean seropositive rate of the six farms was 17.5%, the range of seropisitivity was 3.4-57.1% due to the difference in seroprevalence between farms. The general pattern of seropositivity in cows was higher than in heifers. In addition, the abortion rate of N. caninumpositive in 18 out of 32 pregnant dams raised in four farms was 16.7%. The seroprevalence of newborn calves from N. caninum-positive pregnant animals differed according to the farm but was 86.7% overall. In contrast, 14 newborn calves from the N. caninum-negative pregnant cattle showed negative responses. This suggests that N. caninum is endemic and occurs through vertical transmission from chronically-infected dams. Therefore, aborted dams should be discarded.

The Research of Interworking System for Closed Plant Factories (식물공장을 위한 인터워킹 서비스 시스템에 대한 연구)

  • Lee, Myeongbae;Baek, Miran;Park, Jangwoo;Cho, Yongyun;Shin, Changsun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.91-97
    • /
    • 2018
  • The plant factory represents one of the future agricultural systems into which ubiquitous information technology (U-IT) is incorporated, including sensor networking, and helps minimize the influence of external experimental factors that constrain the use of existing greenhouse cultivation techniques. A plant factory's automated cultivation system does not merely provide convenience for crop cultivation, but also expandability as a platform that helps build a knowledge database based on its acquired information and develop education and other application services using the database. For the expansion of plant factory services, this study designed a plant factory interworking service (PFIS) which allows plant factories to share crop growth-related information efficiently among them and performed a test on the service and its implementation.

Effect of social order, perch, and dust-bath allocation on behavior in laying hens

  • Wang, Yanan;Zhang, Runxiang;Wang, Lisha;Li, Jianhong;Su, Yingying;Li, Xiang;Bao, Jun
    • Animal Bioscience
    • /
    • v.35 no.2
    • /
    • pp.299-307
    • /
    • 2022
  • Objective: The objective of this study was to determine the effects of different social ranking order (SRO) and the enrichments (perch and dust-bath) allocation (EA) on behavior of laying hens in furnished cages. Methods: Total experimental period was 4 weeks. There were 216 Hy-line brown layers beak-trimmed at 1 d of age and selected randomly at 14 weeks of age from a commercial farm, and randomly divided into 36 cages with 6 hens in each cage. High enrichments (perch and dust-bath) allocation (HEA) and low enrichments (perch and dust-bath) allocation (LEA) were provided. Video observations of behavior were obtained from the focal hens between 14 and 18 weeks of age and perching, dust-bathing and other general behaviors of the hens with different social orders were measured. Results: Perching behavior of high SRO hens (HSR) were significantly higher than that of medium SRO hens (MSR), and that of the MSR were significantly higher than that of low SRO hens (LSR) (p<0.01), except for lying on perch (p>0.05). The hens in the high EA cage (HEAC) showed more lying behavior on perch than those in the low EA cage (LEAC) (p<0.01). The different SRO and EA did not affect dust-bathing behavior except vertical wing-shaking behavior (p<0.05). The LEA did not affect general behaviors (p>0.05), except standing and preening behaviors (p<0.01 and p<0.05), of which the hens in the HEAC showed less standing (p<0.01) and more preening behavior than the hens in the LEAC. Conclusion: The SRO of laying hens has a significant effect on the perching behaviors, but SRO and EA have little effect on dust-bathing and general behaviors.

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Numerical Simulation in relation with Coastal Current and Stratification of Water at the Semi-enclosed Estuary (반폐쇄하구에서의 유동 및 성충구조에 관한 시뮬레이션)

  • Lee, Woo-Chul;Lee, Joong-Woo;Park, Dong-Jin
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.565-572
    • /
    • 2004
  • Residual current plays more important role than the tidal current for long-term material transport in coastal areas. The main component of residual current is tide-induced residual current. Otherwise, wind driven current and buoyancy-driven current are important components which change the residual current. To clarify the characteristic of coastal current, application of a three -dimensional model is necessary. This study focuses on clarifying the stratified systems of coastal water affected by freshwater runoff from a river and analyzes the structure of current at Ulsan bay by applying a three-dimensional buoyancy-driven current model. According to the result of “Ulsan bay” study, it shows that the surface layer in semi-enclosed estuaries, which affected by freshwater runoff. has flows going out, and the bottom layer has flows coming in. Besides when the wind blows toward inside of the bay, the surface layer has flows coming in and the bottom layer has flows going out as compensation flows for the surface circulation. The results of simulation could be applicable to examine vertical upwelling, which might be caused by construction of artificial fishing reef to build aqua farm, submerged breakwater to control coastal sediment, and the formulation of oceanic ridge, or a basic study on application to the usage of deep water.

Modeling the effects of excess water on soybean growth in converted paddy field in Japan 1. Predicting groundwater level and soil moisture condition - The case of Biwa lake reclamation area

  • Kato, Chihiro;Nakano, Satoshi;Endo, Akira;Sasaki, Choichi;Shiraiwa, Tatsuhiko
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.315-315
    • /
    • 2017
  • In Japan, more than 80 % of soybean growing area is converted fields and excess water is one of the major problems in soybean production. For example, recent study (Yoshifuji et al., 2016) suggested that in the fields of shallow groundwater level (GWL) (< 1m depth), rising GWL even in a short period (e.g. 1 day) causes inhibition of soybean growth. Thus it becomes more and more important to predict GWL and soil moisture in detail. In addition to conventional surface drainage and underdrain, FOEAS (Farm Oriented Enhancing Aquatic System), which is expected to control GWL in fields adequately, has been developed recently. In this study we attempted to predict GWL and soil moisture condition at the converted field with FOEAS in Biwa lake reclamation area, Shiga prefecture, near the center of the main island of Japan. Two dimensional HYDRUS model (Simuinek et al., 1999) based on common Richards' equation, was used for the calculation of soil water movement. The calculation domain was considered to be 10 and 5 meter in horizontal and vertical direction, respectively, with two layers, i.e. 20cm-thick of plowed layer and underlying subsoil layer. The center of main underdrain (10 cm in diameter) was assumed to be 5 meter from the both ends of the domain and 10-60cm depth from the surface in accordance with the field experiment. The hydraulic parameters of the soil was estimated with the digital soil map in "Soil information web viewer" and Agricultural soil-profile physical properties database, Japan (SolphyJ) (Kato and Nishimura, 2016). Hourly rainfall depth and daily potential evapo-transpiration rate data were given as the upper boundary condition (B.C.). For the bottom B.C., constant upward flux, which meant the inflow flux to the field from outside, was given. Seepage face condition was employed for the surrounding of the underdrain. Initial condition was employed as GWL=60cm. Then we compared the simulated and observed results of volumetric water content at depth of 15cm and GWL. While the model described the variation of GWL well, it tended to overestimate the soil moisture through the growing period. Judging from the field condition, and observed data of soil moisture and GWL, consideration of soil structure (e.g. cracks and clods) in determination of soil hydraulic parameters at the plowed layer may improve the simulation results of soil moisture.

  • PDF

Comparison on Temperature, Humidity and Weight Changes among Different Types of Hive for the Asiatic Honeybee(Apis cerana) (개량형 토종꿀벌 (Apis cerana) 벌통의 유형별 온·습도와 무게변화 비교)

  • Lee, Chan-Ju;Hong, Young-Hee;Lee, Myeong-lyeol;Ryu, Cheol-Hyeong;Kim, Soon-Il
    • Journal of Apiculture
    • /
    • v.35 no.1
    • /
    • pp.9-19
    • /
    • 2020
  • The questionnaire survey for Apis cerana beekeepers and professionals on improved native bee hives was carried out and we compared the temperature, relative humidity(RH), and weight changes of 4 improved hives(Chungju, Miryang, Hanam, and Suwon) from May 1, 2019 to January 31, 2020. Beekeepers need vertical feeder, hive stand, entrance block, and separating panel as hive accessory devices. The average temperatures within brood area were kept constantly (31.3~35.1℃) and the low daily variances of temperature (≤1℃) in Chungju hive among tested hives were observed. The daily temperature variances in the separated space and on the top of winter cluster were not different among 4 hives. In correlation between the temperature of brood area and the number of combs, Chungju hive showed the highest correlation(80.4%) and between the temperature on top of winter clusters and outside temperature, 4 hives showed high positive correlation(76.8~87.1%). RH of brood area(45~60%) in all hives were kept relatively low and constant compared to the outside RH(60~85%). The stablest RH on the top of winter cluster was observed in Suwon hives (65~75%) The highest cumulative weight increase among hives and the high positive correlation(65~67%) between the change of cumulative hive weight and combs number of hives were shown in the Miryang and Chungju. Based on these results, A. cerana bees are able to manage constant temperature and RH within hives area for their colony life, which also effected by the types of hive.

A Study on the Distance Error Correction of Maritime Object Detection System (해상물체탐지시스템 거리오차 보정에 관한 연구)

  • Byung-Sun Kang;Chang-Hyun Jung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.139-146
    • /
    • 2023
  • Maritime object detection systems, which detects small maritime obstacles such as fish farm buoys and visualizes distance and direction, is equipped with a 3-axis gimbal to compensate for errors caused by hull motion, but there is a limit to distance error corrections necessitated by the vertical movement of the camera and the maritime object due to wave motions. Therefore, in this study, the distance error of maritime object detection systems caused by the movement of the water surface according to the external environment is analyzed and corrected using average filter and moving average filter. Random numbers following a Gaussian standard normal distribution were added to or subtracted from the image coordinates to reproduce the rise or fall of the buoy under irregular waves. The distance calculated according to the change of image coordinates, the predicted distance through the average filter and the moving average filter, and the actual distance measured by laser distance meter were compared. In phases 1 and 2, the error rate increased to a maximum of 98.5% due to the changes of image coordinates due to irregular waves, but the error rate decreased to 16.3% with the moving average filter. This error correction capability was better than with the average filter, but there was a limit due to failure to respond to the distance change. Therefore, it is considered that use of the moving average filter to correct the distance error of the maritime object detection system will enhance responses to the real-time distance change and greatly improve the error rate.