• 제목/요약/키워드: Vertebral height

검색결과 86건 처리시간 0.023초

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

Anatomical Morphometric Study of the Cervical Uncinate Process and Surrounding Structures

  • Kim, Sung-Ho;Lee, Jae Hack;Kim, Ji Hoon;Chun, Kwon Soo;Doh, Jae Won;Chang, Jae Chil
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.300-305
    • /
    • 2012
  • Objective : The purpose of this study is to elucidate the anatomic relationships between the uncinate process and surrounding neurovascular structures to prevent possible complications in anterior cervical surgery. Methods : Twenty-eight formalin-fixed cervical spines were removed from adult cadavers and were studied. The authors investigated the morphometric relationships between the uncinate process, vertebral artery and adjacent nerve roots. Results : The height of the uncinate process was 5.6-7.5 mm and the width was 5.8-8.0 mm. The angle between the posterior tip of the uncinate process and vertebral artery was $32.2-42.4^{\circ}$. The distance from the upper tip of the uncinate process to the vertebral body immediately above was 2.1-3.3 mm, and this distance was narrowest at the fifth cervical vertebrae. The distance from the posterior tip of the uncinate process to the nerve root was 1.3-2.0 mm. The distance from the uncinate process to the vertebral artery was measured at three different points of the uncinate process : upper-posterior tip, lateral wall and the most antero-medial point of the uncinate process, and the distances were 3.6-6.1 mm, 1.7-2.8 mm, and 4.2-5.7 mm, respectively. The distance from the uncinate process tip to the vertebral artery and the angle between the uncinate process tip and vertebral artery were significantly different between the right and left side. Conclusion : These data provide guidelines for anterior cervical surgery, and will aid in reducing neurovascular injury during anterior cervical surgery, especially in anterior microforaminotomy.

Comparison of Morphological Characteristics of the Subaxial Cervical Spine between Athetoid Cerebral Palsy and Normal Control

  • Kim, Jun Young;Kwon, Jae Yeol;Kim, Moon Seok;Lee, Jeong Jae;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.243-250
    • /
    • 2018
  • Objective : To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. Methods : We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. Results : LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. Conclusion : LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.

The Effect of Postural Correction and Subsequent Balloon Inflation in Deformity Correction of Acute Osteoporotic Vertebral Fractures

  • Liu, Hai-Xiao;Xu, Cong;Shang, Ping;Shen, Yue;Xu, Hua-Zi
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권6호
    • /
    • pp.337-342
    • /
    • 2014
  • Objective : To determine deformity correction by postural correction and subsequent balloon inflation in acute vertebral compression fractures (OVCFs) and to examine the effect of bone mineral density on deformity correction. Methods : A totol of 50 acute OVCFs received balloon kyphoplasty. Lateral radiographs were taken and analyzed at five different time points : 1) preoperative, 2) after placing the patient in prone hyperextended position, 3) after balloon inflation, 4) after deposition of the cement, and 5) postoperative. All fractures were analyzed for height restoration of anterior (Ha), middle (Hm) and posterior (Hp) vertebra as well as Cobb angle and Kyphotic angle. The bone mineral density (BMD) of lumbar spine was measured by dual-energy X-ray absorptiometry. According to the T-score, the patients were divided into two groups which were osteoporosis group and osteopenia group. Results : Postoperative measurements of Ha, Hm and the Cobb angle demonstrated significant reduction of 4.62 mm, 3.66 mm and $5.34^{\circ}$ compared with the preoperative measurements, respectively (each p<0.05). Postural correction significantly increased Ha by 5.51 mm, Hm by 4.35 mm and improved the Cobb angle by $8.32^{\circ}$ (each p<0.05). Balloon inflation did not demonstrate a significant improvement of Ha, Hm or the Cobb angle compared with baseline prone hyperextended. Postural correction led to greater improvements of Ha, Hm and Cobb angle in osteoporosis group than osteopenia group (each p<0.05). Conclusion : In acute OVCFs, the height restoration was mainly attributed to postural correction rather than deformity correction by balloon inflation. BMD affected deformity correction in the process of postural correction.

Short Segment Screw Fixation without Fusion for Unstable Thoracolumbar and Lumbar Burst Fracture : A Prospective Study on Selective Consecutive Patients

  • Kim, Hee-Yul;Kim, Hyeun-Sung;Kim, Seok-Won;Ju, Chang-Il;Lee, Sung-Myung;Park, Hyun-Jong
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권4호
    • /
    • pp.203-207
    • /
    • 2012
  • Objective: The purpose of this prospective study was to evaluate the efficacy and safety of screw fixation without bone fusion for unstable thoracolumbar and lumbar burst fracture. Methods: Nine patients younger than 40 years underwent screw fixation without bone fusion, following postural reduction using a soft roll at the involved vertebra, in cases of burst fracture. Their motor power was intact in spite of severe canal compromise. The surgical procedure included postural reduction for 3 days and screw fixations at one level above, one level below and at the fractured level itself. The patients underwent removal of implants 12 months after the initial operation, due to possibility of implant failure. Imaging and clinical findings, including canal encroachment, vertebral height, clinical outcome, and complications were analyzed. Results: Prior to surgery, the mean pain score (visual analogue scale) was 8.2, which decreased to 2.2 at 12 months after screw fixation. None of the patients complained of worsening of pain during 6 months after implant removal. All patients were graded as having excellent or good outcomes at 6 months after implant removal. The proportion of canal compromise at the fractured level improved from 55% to 35% at 12 months after surgery. The mean preoperative vertebral height loss was 45.3%, which improved to 20.6% at 6 months after implant removal. There were no neurological deficits related to neural injury. The improved vertebral height and canal compromise were maintained at 6 months after implant removal. Conclusion: Short segment pedicle screw fixation, including fractured level itself, without bone fusion following postural reduction can be an effective and safe operative technique in the management of selected young patients suffering from unstable burst fracture.

Quantification of Pediatric Cervical Growth : Anatomical Changes in the Sub-Axial Spine

  • Lee, Ho Jin;Lee, Jung Jae;Hong, Jae Taek;Kim, Jong Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권3호
    • /
    • pp.185-191
    • /
    • 2015
  • Objective : In order to provide normal values of the pediatric sub-axial cervical spinal canal and vertebral body growth pattern using computed tomographic scans, a total of 318 patients less than 10 years old were included. Methods : The growth of the vertebral body and canal space was investigated using four different age groups. The Torg ratio (TR) was calculated and all patients were classified into a low TR group and a high TR group according to a cutoff value of 1.0. To account for spinal curvature, the C3-7 angle was measured. Results : Very little axial expansion and growth in height were observed (2.9 mm and 3.4 mm, respectively), and the spinal canal increments (1.8 mm) were much smaller than the dimensions of the vertebral body. The mean TR values were $1.03{\pm}0.14$ at the C3 vertebral level, $1.02{\pm}0.13$ at C4, $1.05{\pm}0.13$ at C5, $1.04{\pm}0.13$ at C6, and $1.02{\pm}0.12$ at C7 in all patients. The mean sub-axial angle (C3-7) was $7.9{\pm}10.6^{\circ}$ (range: $-17-47^{\circ}$). Conclusion : The upper sub-axial spinal canal continuously increased in size compared to the lower sub-axial spine after 8 years of age. Considerable decrements in the TR was found after late childhood compared to younger ages. Generally, there were no significant differences between boys and girls in vertical length of the cervical vertebrae. However, the axial dimension of the vertebral body and the spinal canal space varied according to gender.

시멘트 누출 위험성이 높은 환자에서의 풍선 척추몸통뼈 복원술 -증례보고- (A Case of Balloon Kyphoplasty in High Risk under Cement Leakage -A case report-)

  • 최윤숙;이미금;이효민;조지연;정희진;이철중;이상철;김용철;심성은
    • The Korean Journal of Pain
    • /
    • 제19권2호
    • /
    • pp.261-265
    • /
    • 2006
  • A vertebral compression fracture can cause chronic back pain, and may also result in progressive kyphosis. The traditional treatments of a vertebral compression fracture include bed rest, analgesics and bracing. Balloon kyphoplasty can restore the vertebral height and allow safe bone cement injection into the cavity made by the balloon, which significantly reduces the risk of cement leakage compared to vertebroplasty. An 82-year-old female patient suffered from severe low back pain. Due to the intractable pain and immobility, which could not be relieved by conventional care, as well as the empty vertebral body associated with communicated fractures of the vertebral surfaces, balloon kyphoplasty, with a thicker bone cement injection than usual with balloon kyphoplasty, was chosen. The preoperative intractable pain and immobility were dramatically relieved soon after the procedure, without any complications.

Clinical Identification of the Vertebral Level at Which the Lumbar Sympathetic Ganglia Aggregate

  • An, Ji Won;Koh, Jae Chul;Sun, Jong Min;Park, Ju Yeon;Choi, Jong Bum;Shin, Myung Ju;Lee, Youn Woo
    • The Korean Journal of Pain
    • /
    • 제29권2호
    • /
    • pp.103-109
    • /
    • 2016
  • Background: The location and the number of lumbar sympathetic ganglia (LSG) vary between individuals. The aim of this study was to determine the appropriate level for a lumbar sympathetic ganglion block (LSGB), corresponding to the level at which the LSG principally aggregate. Methods: Seventy-four consecutive subjects, including 31 women and 31 men, underwent LSGB either on the left (n = 31) or the right side (n = 43). The primary site of needle entry was randomly selected at the L3 or L4 vertebra. A total of less than 1 ml of radio opaque dye with 4% lidocaine was injected, taking caution not to traverse beyond the level of one vertebral body. The procedure was considered responsive when the skin temperature increased by more than $1^{\circ}C$ within 5 minutes. Results: The median responsive level was significantly different between the left (lower third of the L4 body) and right (lower margin of the L3 body) sides (P = 0.021). However, there was no significant difference in the values between men and women. The overall median responsive level was the upper third of the L4 body. The mean responsive level did not correlate with height or BMI. There were no complications on short-term follow-up. Conclusions: Selection of the primary target in the left lower third of the L4 vertebral body and the right lower margin of the L3 vertebral body may reduce the number of needle insertions and the volume of agents used in conventional or neurolytic LSGB and radiofrequency thermocoagulation.

Cervical Stand-Alone Polyetheretherketone Cage versus Zero-Profile Anchored Spacer in Single-Level Anterior Cervical Discectomy and Fusion : Minimum 2-Year Assessment of Radiographic and Clinical Outcome

  • Cho, Hyun-Jun;Hur, Junseok W.;Lee, Jang-Bo;Han, Jin-Sol;Cho, Tai-Hyoung;Park, Jung-Yul
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권2호
    • /
    • pp.119-124
    • /
    • 2015
  • Objective : We compared the clinical and radiographic outcomes of stand-alone polyetheretherketone (PEEK) cage and Zero-Profile anchored spacer (Zero-P) for single level anterior cervical discectomy and fusion (ACDF). Methods : We retrospectively reviewed 121 patients who underwent single level ACDF within 2 years (Jan 2011-Jan 2013) in a single institute. Total 50 patients were included for the analysis who were evaluated more than 2-year follow-up. Twenty-nine patients were allocated to the cage group (m : f=19 : 10) and 21 for Zero-P group (m : f=12 : 9). Clinical (neck disability index, visual analogue scale arm and neck) and radiographic (Cobb angle-segmental and global cervical, disc height, vertebral height) assessments were followed at pre-operative, immediate post-operative, post-3, 6, 12, and 24 month periods. Results : Demographic features and the clinical outcome showed no difference between two groups. The change between final follow-up (24 months) and immediate post-op of Cobb-segmental angle (p=0.027), disc height (p=0.002), vertebral body height (p=0.033) showed statistically better outcome for the Zero-P group than the cage group, respectively. Conclusion : The Zero-Profile anchored spacer has some advantage after cage for maintaining segmental lordosis and lowering subsidence rate after single level anterior cervical discectomy and fusion.

Minimum 2-Year Follow-Up Result of Degenerative Spinal Stenosis Treated with Interspinous U ($Coflex^{TM}$)

  • Park, Seong-Cheol;Yoon, Sang-Hoon;Hong, Yong-Pyo;Kim, Ki-Jeong;Chung, Sang-Ki;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.292-299
    • /
    • 2009
  • Objective : Clinical and radiological results of posterior dynamic stabilization using interspinous U (ISU, $Coflex^{TM}$, Paradigm Spine $Inc.^{(R)}$, NY, USA) were analyzed in comparison with posterior lumbar interbody fusion (PLIF) in degenerative lumbar spinal stenosis (LSS). Methods : A retrospective study was conducted for a consecutive series of 61 patients with degenerative LSS between May 2003 and December 2005. We included only the patients completed minimum 24 months follow up evaluation. Among them, 30 patients were treated with implantation of ISU after decompressive laminectomy (Group ISU) and 31 patients were treated with wide decompressive laminectomy and posterior lumbar interbody fusion (PLIF; Group PLIF). We evaluated visual analogue scale (VAS) and Oswestry Disability Index (ODI) for clinical outcomes (VAS, ODI), disc height ratio disc height (DH), disc height/vertebral body length ${\times}100$), static vertebral slip (VS) and depth of maximal radiolucent gap between ISU and spinous process) in preoperative, immediate postoperative and last follow up. Results : The mean age of group ISU ($66.2{\pm}6.7$ years) was 6.2 years older than the mean age of group PLIF ($60.4{\pm}8.1$ years; p=0.003). In both groups, clinical measures improved significantly than preoperative values (p<0.001). Operation time and blood loss was significantly shorter and lower in group ISU than group PLIF (p<0.001). In group ISU, the DH increased transiently in immediate postoperative period ($15.7{\pm}4.5%{\rightarrow}18.6{\pm}5.9%$), however decreased significantly in last follow up ($13.8{\pm}6.6%$, p=0.027). Vertebral slip (VS) of spondylolisthesis in group ISU increased during postoperative follow-up ($2.3{\pm}3.3{\rightarrow}8.7{\pm}6.2$, p=0.040). Meanwhile, the postoperatively improved DH and VS was maintained in group PLIF in last follow up. Conclusion : According to our result, implantation of ISU after decompressive laminectomy in degenerative LSS is less invasive and provides similar clinical outcome in comparison with the instrumented fusion. However, the device has only transient effect on the postoperative restoration of disc height and reduction of slip in spondylolisthesis. Therefore, in the biomechanical standpoint, it is hard to expect that use of Interspinous U in decompressive laminectomy for degenerative LSS had long term beneficial effect.