• Title/Summary/Keyword: Vertebral

Search Result 945, Processing Time 0.033 seconds

Change of Cervical Angle According to Smartphone using Time (스마트폰 사용 시간이 목뼈 각도 변화에 미치는 영향)

  • Kim, Soo-Han;Kim, Ko-Un
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.141-149
    • /
    • 2014
  • PURPOSE: This study uses X-rays investigate how university students' smart phone use affects the cervical vertebral angle. METHODS: Ninety-two randomly selected students agreed to participate in this study. The participants' number of hours of smart phone use was gathered using a questionnaire. An X-ray of the participants' cervical vertebrae was taken, and the cervical vertebral angle was measured using the Cobb and the absolute rotation angle (ARA) method. Also, the relation between pain and hours of smart phone use was identified using a visual analog scale (VAS). Using SPSS ver18, the relationships among the cervical vertebral angle and the items in the questionnaire were identified and a frequency analysis, an independent t-test, and the analysis of variance (ANOVA) were calculated. RESULTS: The study showed that an increase in the number hours of smart phone per day led to cervical lordosis(p<0.05). The relationships between points of smart phone addiction and cervical vertebral angle have a negative correlation (p<0.05). Therefore, there are the higher smart phone addiction points, the decrease the cervical vertebral angle. CONCLUSION: The results of the study showed that increase in smart phone use lead to cervical lordosis, and smart phone addiction scores resulted in decreased in the cervical vertebral angle.

Vertebral Artery Injury during Anterior Cervical Spine Surgery : Report of Two Cases (전방경추수술중 추골동맥 손상 : 2예 보고)

  • Lee, Dong Girl;Rhim, Seung Chul;Roh, Sung Woo;Im, Su Bin;Kwon, Yang;Kwun, Byung Duk
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.231-238
    • /
    • 2001
  • Vertebral artery injury is a rare complication of anterior cervical approach. We report two patients who suffered injury to vertebral artery during anterior cervical spine surgery. The mechanism of injury, their operative management, and the subsequent outcome were assessed and relevant literatures reviewed. The awareness of the possibility of vertebral artery injury is most important to prevent and it's occurrence is best avoided by a thorough understanding of the anatomical relationships of the artery, the spinal canal, and the vertebral body and careful use of surgical instruments.

  • PDF

The Inaccuracy of Surface Landmarks for the Anterior Approach to the Cervical Spine in Southern Chinese Patients

  • Ko, Tin Sui;Tse, Michael Siu Hei;Wong, Kam Kwong;Wong, Wing Cheung
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1123-1126
    • /
    • 2018
  • Study Design: Observational study. Purpose: To assess the correlational accuracy between the traditional anatomic landmarks of the neck and their corresponding vertebral levels in Southern Chinese patients. Overview of Literature: Recent studies have demonstrated discrepancies between traditional anatomic landmarks of the neck and their corresponding cervical vertebra. Methods: The center of the body of the hyoid bone, the upper limit of the lamina of the thyroid cartilage, and the lower limit of the cricoid cartilage were selected as representative surface landmarks for this investigation. The corresponding vertebral levels in 78 patients were assessed using computed tomography. Results: In both male and female patients, almost none of the anatomical landmarks demonstrated greater than 50% correlation with any vertebral level. The most commonly corresponding vertebra of the hyoid bone, the lamina of the thyroid cartilage, and the cricoid cartilage were the C4 (47.5%), C5 (35.9%), and C7 (42.3%), respectively, which were all different from the classic descriptions in textbooks. The vertebral levels corresponding with the thyroid and cricoid cartilage were significantly different between genders. Conclusions: The surface landmarks of the neck were not accurate enough to be used as the sole determinant of vertebral levels or incision sites. Intra-operative fluoroscopy is necessary to accurately locate each of the cervical vertebral levels.

The Role of Bone Cement Augmentation in the Treatment of Chronic Symptomatic Osteoporotic Compression Fracture

  • Kim, Hyeun-Sung;Kim, Sung-Hoon;Ju, Chang-Il;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.490-495
    • /
    • 2010
  • Objective : Bone cement augmentation procedures such as percutaneous vertebroplasty and balloon kyphoplasty have been shown to be effective treatment for acute or subacute osteoporotic vertebral compression fractures. The purpose of this study was to determine the efficacy of bone cement augmentation procedures for long standing osteoporotic vertebral compression fracture with late vertebral collapse and persistent back pain. Methods : Among 278 single level osteoporotic vertebral compression fractures that were treated by vertebral augmentation procedures at our institute, 18 consecutive patients were included in this study. Study inclusion was limited to initially, minimal compression fractures, but showing a poor prognosis due to late vertebral collapse, intravertebral vacuum clefts and continuous back pain despite conservative treatment for more than one year. The subjects included three men and 15 women. The mean age was 70.7 with a range from 64 to 85 years of age. After postural reduction for two days, bone cement augmentation procedures following intraoperative pressure reduction were performed. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period after bone cement augmentation procedures was 14.3 months (range 12-27 months). The mean injected cement volume was 4.1 mL (range 2.4-5.9 mL). The unipedicular approach was possible in 15 patients. The mean pain score (visual analogue scale) prior to surgery was 7.1, which decreased to 3.1 at 7 days after the procedure. The pain relief was maintained at the final follow up. The kyphotic angle improved significantly from $21.2{\pm}4.9^{\circ}$ before surgery to $10.4{\pm}3.8^{\circ}$ after surgery. The fraction of vertebral height increased from 30% to 60% after bone cement augmentation, and the restored vertebral height was maintained at the final follow up. There were no serious complications related to cement leakage. Conclusion : In the management of even long-standing osteoporotic vertebral compression fracture for over one year, bone cement augmentation procedures following postural reduction were considered safe and effective treatment in cases of non-healing evidence.

Vertebroplasty Utilizing Percutaneous Vertebral Body Access (PVBA) Technique for Osteoporotic Vertebral Compression Fractures in the Middle Thoracic Vertebrae

  • Cho, Yong-Jun;Choi, Jong-Hun;Cho, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.3
    • /
    • pp.161-165
    • /
    • 2007
  • Objective : Percutaneous approach to the middle thoracic vertebra through the transpedicular route for the patients with osteoporotic vertebral compression fractures is difficult due to the small size of the pedicle and parasagittally oriented vertebra body anatomy. The percutaneous vertebral body access [PVBA] technique utilizing the posterolateral extrapedicular approach avoids the pedicle and provides direct access to the vertebral body. The objective of this study is to evaluate the efficacy of the vertebroplasty utilizing PVBA technique for osteoporotic vertebral compression fractures in the middle thoracic vertebrae. Methods : A retrospective review was done on 20 patients who underwent vertebroplasty utilizing PVBA technique performed for painful osteoporotic compression fracture in the middle thoracic vertebrae at 22 levels from May 2003 to June 2006. The average amount of the injected cement was 1.5-2.5ml. The postprocedural outcome was assessed using a visual analogue scale [VAS]. Results : The treated vertebrae were T5 [1 level], T6 [5 levels], 17 [7 levels], and T8 [9 levels]. The compression rate and kyphotic angle were improved after procedure from $18%{\pm}13.4$ to $16%{\pm}13.8$ [p > 0.05] and from $6.9^{\circ}{\pm}6.7$ to $6.6^{\circ}{\pm}6.2$ [p>005], respectively. Preprocedural VAS was $8.2{\pm}0.70$ and was decreased to $2.1{\pm}1.02$ [p < 0.01] after treatment. Postprocedural cement leakage was noted in 3 levels [13.7%]. There were no cases of leakage to epidural space or neural foramen, segmental artery injury, and pneumothorax. Conclusion : These results suggest that the complication rates are low and good results can be achieved with vertebroplasty utilizing PVBA technique for the osteoporotic vertebral compression fractures especially in the middle thoracic vertebrae.

Anatomical Morphometric Study of the Cervical Uncinate Process and Surrounding Structures

  • Kim, Sung-Ho;Lee, Jae Hack;Kim, Ji Hoon;Chun, Kwon Soo;Doh, Jae Won;Chang, Jae Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.300-305
    • /
    • 2012
  • Objective : The purpose of this study is to elucidate the anatomic relationships between the uncinate process and surrounding neurovascular structures to prevent possible complications in anterior cervical surgery. Methods : Twenty-eight formalin-fixed cervical spines were removed from adult cadavers and were studied. The authors investigated the morphometric relationships between the uncinate process, vertebral artery and adjacent nerve roots. Results : The height of the uncinate process was 5.6-7.5 mm and the width was 5.8-8.0 mm. The angle between the posterior tip of the uncinate process and vertebral artery was $32.2-42.4^{\circ}$. The distance from the upper tip of the uncinate process to the vertebral body immediately above was 2.1-3.3 mm, and this distance was narrowest at the fifth cervical vertebrae. The distance from the posterior tip of the uncinate process to the nerve root was 1.3-2.0 mm. The distance from the uncinate process to the vertebral artery was measured at three different points of the uncinate process : upper-posterior tip, lateral wall and the most antero-medial point of the uncinate process, and the distances were 3.6-6.1 mm, 1.7-2.8 mm, and 4.2-5.7 mm, respectively. The distance from the uncinate process tip to the vertebral artery and the angle between the uncinate process tip and vertebral artery were significantly different between the right and left side. Conclusion : These data provide guidelines for anterior cervical surgery, and will aid in reducing neurovascular injury during anterior cervical surgery, especially in anterior microforaminotomy.

Morphometric Measurement of the Anatomical Landmark in Anterior Cervical Microforaminotomy

  • Chang, Jae-Chil;Park, Hyung-Ki;Bae, Hack-Gun;Cho, Sung-Jin;Choi, Soon-Kwan;Byun, Park-Jang
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.340-346
    • /
    • 2006
  • Objective : The lack of anatomical knowledge for the anterior cervical microforaminotomy is liable to injure the neurovascular structures. The surgical anatomy is examined with special attention to the ventral aspect exposed in anterior cervical microforaminotomy. Methods : In 16adult formalin fixed cadaveric cervical spine, the author measured the distances from the medical margin of the longus colli to the medical wall of the ipsilateral vertebral artery and the angle for the ipsilateral vertebral artery. The distances from the lateral margin of the posterior longitudinal ligament to the medial margin of the ipsilateral medial wall of the vertebral artery, to the ipsilateral dorsal root ganglion was measured too. Results : The distance from the medial margin of the longus colli to the ipsilateral vertebral artery was $13.3{\sim}14.7mm$ and the angle for the ipsilateral vertebral artery was $41{\sim}42.5\;degrees$. The range of distance from the lateral margin of the posterior longitudinal ligament to the ipsilateral vertebral artery was $11.9{\sim}16.1mm$, to the ipsilateral dorsal root ganglion was $11.6{\sim}12.9mm$. Conclusion : These data will aid in reducing neurovascular injury during anterior cervical approaches.

Therapeutic Effects of Kyphoplasty on Osteoporotic Vertebral Fractures (골다공성 척추체 골절에서 척추 후만변형 복원술의 치료효과)

  • Park, Chun-Kun;Kim, Dong-Hyun;Ryu, Kyung-Sik;Son, Byung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.116-123
    • /
    • 2005
  • Objective: Percutaneous kyphoplasty using a balloon-catheter is an widely accepted method which achieves the restoration of vertebral height and the correction of kyphotic deformity with little complication in osteoporotic vertebral compression fractures. The authors assess the results of 59 patients who underwent kyphoplasty, and analyze the factors that could affect the prognosis. Methods: From December 2001 to May 2003, fifty-nine patients underwent kyphoplasty. The patients included 49 women and 10 men aged 52-85 years. Average t-score on bone marrow density was -3.58. About 7cc of polymethylmethacrylate(PMMA) was injected into the fractured vertebral body using $Kyphon^{(R)}$ under local anesthesia. The vertical height of all fractured vertebrae was measured both before and after surgery. Outcome data were obtained by comparing pre- and post-operative VAS score and by assessing postoperative satisfaction, drug dependency and activity. Various clinical factors were analyzed to assess the relationship with the outcome. Results: The VAS score improved significantly, and the mean percentage of restored vertebral height was 53%. The mean improvement in kyphosis was $3.6^{\circ}$. Eighty-nine percent of the patients gained excellent or good results. Any of the clinical factors including the interval between fracture and operation, the degree of height loss, the degree of the vertebral height restoration or the correction rate of kyphosis did not affect the clinical results. Conclusion: Kyphoplasty is associated with a statistically significant improvement in pain and function with little complication. The clinical results are not affected by any clinical parameters. Further follow-up study is needed to determine whether the restoration affects the long-term clinical results.

Evaluation of computed tomographic and radiographic myelography in normal miniature pigs

  • Choi, Mihyun;Lee, Hyeyeon;Kim, Mieun;Kim, Junyoung;Lee, Namsoon;Chang, Jinhwa;Jung, Joohyun;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • Evaluation of the myelography was studied in miniature pigs. Radiographs and computed tomographic (CT) images of the whole spine were obtained at clinically healthy twelve miniature pigs of 4 (8.7-10 kg) and 12 (26-31 kg) months. The assessments of the spinal cord were made in accordance with the Pavlov's method and compared area ratio [at spinal cord (SC), vertebral canal (VC) and vertebral body (VB)]. The Pavlov's ratio in the cervical spine was significant larger than that of thoracolumbar in radiographic myelography. On CT myelography, the area of the spinal cord had a significant difference between the cervical and thoracolumbar spine. Among the cervical spine, the ratios of spinal cord and vertebral body (SC : VB), vertebral canal and vertebral body (VC : VB) were minimum at the level of 4th cervical spine in both ages, while maximum at the level of 6th cervical spine in both months. In case of lumbar spine, the ratios of spinal cord and vertebral body (SC : VB) were the largest at the level of 4th lumbar spine in 4 months and at the level of 3rd lumbar spine in 12 months. In addition, the ratio of spinal cord and vertebral body (SC : VB) of the cervical spinal cord was significant lower at 4 months but the lumbar spinal cord showed lower pattern at 12 months old miniature pigs.

Morphologic Diversities of Sacral Canal in Children;Three-Dimensional Computed Tomographic Study

  • Kim, Dae Wook;Lee, Seung Jun;Choi, Eun Joo;Lee, Pyung Bok;Jo, Young Hyun;Nahm, Francis Sahngun
    • The Korean Journal of Pain
    • /
    • v.27 no.3
    • /
    • pp.253-259
    • /
    • 2014
  • Background: Caudal block is a common technique in children for reducing postoperative pain, and there have been several reports on the variations of the sacral canal in children. However, previous studies have mainly focused on the needle trajectory for caudal block, and there is limited information on the structural variations of the sacrum in children. The purpose of this study was to analyze the anatomic variations of sacral canals in children. Methods: Three-dimensional computed tomographic images were analyzed. The data from the images included (1) fusion of the sacral vertebral laminae and the sacral intervertebral space (2) existence of the sacral cornua and (3) the types of sacral hiatus. The types of sacral hiatus were classified into 3 groups: group I (fusion of S3 or S4 vertebral laminae), group II (unfused vertebral arch with the distance of the S3 and S4 vertebral laminae < 50% of the distance between the cornua), and group III (unfused vertebral arch with the distance of the S3 or S4 vertebral laminae ${\geq}50%$ of the distance between the cornua). Results: A total of 143 children were included in this study. All of the sacral vertebral arches were not fused in 22 children (15.4%). Cornua were not identified bilaterally in 5 (3.5%) and unilaterally in 6 (4.2%) children. In the sacral hiatus, group II and group III were identified in 22 (15.4%) and 31 (21.7%) children, respectively. Conclusions: The sacral canal has various anatomical variations in children. Careful attention must be paid to identify the correct anatomic landmark.