• Title/Summary/Keyword: Vertebra

Search Result 406, Processing Time 0.027 seconds

The Effect of Corrective Exercise and TECAR therapy on neck alignments and pain in Forward Head Posture Patients (교정 운동과 TECAR 치료가 전방머리자세를 가진 환자의 목정렬과 통증에 미치는 영향)

  • Park, Si-Eun;Lee, Hyoung-Ryeol;Park, Shin-Jun
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.543-551
    • /
    • 2018
  • This study investigated the effects of corrective exercise and TECAR on cervical alignment, pain threshold, and pain in forward head posture patients. The subject includes 30 forward head posture patients. In the intervention methods, the experimental group combined corrective exercise and TECAR treatment. Only the corrective exercise was applied to the control group. Assessments were made on cervico vertebra angle (CV angle), pain pressure threshold (PPT) and neck disability index (NDI) visual analog scale (VAS). The intervention was conducted six times a week for two weeks. Both groups showed significant differences in CV angle, PPT, NDI, and VAS. Also, PPT, NDI, and VAS excluding CV angle were significantly improved in the study group compared to the control group. These results suggest that the intervention method that combines corrective exercise and TECAR treatment has a more positive effect on pain and ADL ability of forward head posture patient.

A Study of Innovation and Internationalization Strategies by a Hidden Champion Firm in Korea: The Case of CAP Corporation

  • SAMSON, Kouame Kouakou;LEE, Youngwoo
    • Fourth Industrial Review
    • /
    • v.1 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Purpose - This case study analyzes the internationalization strategy and innovation strategy as key factors contributing to the business success of CAP, a small and medium-sized manufacturing company in Korea producing auto parts such as wipers. This study describes the diversification strategies conducted by CAP Corporation and highlights the company's core competencies that have largely contributed to their global competitive success. Research design, data, and methodology - This paper provides in-depth case study on how CAP was able to grow into a hidden champion company, focusing on their strategies since its establishment. In particular, by analyzing the success factors centering on CAP's aggressive innovation strategy and internationalization strategy, it presents guidelines for small and medium-sized enterprises in Asian countries to become a Hidden Champion company. Result - CAP's product technology has successfully established innovative system on their product called 'vertebra spring' to distribute uniform pressure to the rubber to ensure performance as well as durability of their products. In order to continue benefiting from utilizing core competence and to continue pursuing technological advancement in the wiper industry, CAP has launched a wide range of products (flat blade, conventional blade, hybrid blade) applicable to 95% of the vehicle in the market. Conclusion - Taken together, CAP has many aspects of a hidden champion company by investing in R&D up to 8% of its annual sales to R&D investment even during the crises situation. This number is about 3.36 times higher than the average ratio of listed companies in Korea. Furthermore, the leadership of the management team as well as their vision toward the global market and strong commitment to innovation enabled CAP to become the world's fifth-largest wiper and Asia's No. 1 wiper manufacturer.

Development of body position sensor device for posture correction training (자세 교정훈련을 위한 체위 변환 감지 센서 디바이스의 개발)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2020
  • Recently the incidence of musculoskeletal disorders in students and office workers is increasing, and the necessity of maintaining correct posture and corrective training is required, but related research is insufficient. In the previous study, a membrane sensor or a pressure sensor was placed on the seat cushion to see the deviation of the body weight, or a sensor that restrained the user was attached to measure the position change. In this study, a sensor device for detecting a position change in consideration of wearing comfort was developed, and the measured angle was verified through an analysis app. A sensor device consisting of an IMU sensor is attached to the cervical spine and vertebra spine to measure the position transformation in the sitting position. The change value of the position measured by the two sensors was converted into an angle, and the angle value is displayed in real time through the analysis app. In this study, the possibility of measuring the real-time change value according to the change in position, the convenience of wearing, and the tendency of angle measurement were proved. Future research should proceed with more precise angle calculation and correction of motion noise.

Toll-like receptor 4/nuclear factor-kappa B pathway is involved in radicular pain by encouraging spinal microglia activation and inflammatory response in a rat model of lumbar disc herniation

  • Zhu, Lirong;Huang, Yangliang;Hu, Yuming;Tang, Qian;Zhong, Yi
    • The Korean Journal of Pain
    • /
    • v.34 no.1
    • /
    • pp.47-57
    • /
    • 2021
  • Background: Lumbar disc herniation (LDH) is a common cause of radicular pain, but the mechanism is not clear. In this study, we investigated the engagement of toll-like receptor 4 (TLR4) and the nuclear factor-kappa B (NF-κB) in radicular pain and its possible mechanisms. Methods: An LDH model was induced by autologous nucleus pulposus (NP) implantation, which was obtained from coccygeal vertebra, then relocated in the lumbar 4/5 spinal nerve roots of rats. Mechanical and thermal pain behaviors were assessed by using von Frey filaments and hotplate test respectively. The protein level of TLR4 and phosphorylated-p65 (p-p65) was evaluated by western blotting analysis and immunofluorescence staining. Spinal microglia activation was evaluated by immunofluorescence staining of specific relevant markers. The expression of proand anti-inflammatory cytokines in the spinal dorsal horn was measured by enzyme linked immunosorbent assay. Results: Spinal expression of TLR4 and p-NF-κB (p-p65) was significantly increased after NP implantation, lasting up to 14 days. TLR4 was mainly expressed in spinal microglia, but not astrocytes or neurons. TLR4 antagonist TAK242 decreased spinal expression of p-p65. TAK242 or NF-κB inhibitor pyrrolidinedithiocarbamic acid alleviated mechanical and thermal pain behaviors, inhibited spinal microglia activation, moderated spinal inflammatory response manifested by decreasing interleukin (IL)-1β, IL-6, tumor necrosis factor-α expression and increasing IL-10 expression in the spinal dorsal horn. Conclusions: The study revealed that TLR4/NF-κB pathway participated in radicular pain by encouraging spinal microglia activation and inflammatory response.

Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Background: Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. Objectives: We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. Methods: Twenty dogs were included in this retrospective cohort study. Results: Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). Conclusions: IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.

Safety and Efficacy of Bone Cement (Spinofill®) for Verte-broplasty in Patients with Osteoporotic Compression Fracture : A Preliminary Prospective Study

  • Park, Han Byeol;Son, Seong;Jung, Jong Myung;Lee, Sang Gu;Yoo, Byung Rhae
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.730-740
    • /
    • 2022
  • Objective : Although several commercialized bone cements are used during percutaneous vertebroplasty (PVP) for patients with osteoporotic vertebral compression fracture (OVCF), there are no reports using domestic products from South Korea. In this study, we investigated the safety and efficacy of Spinofill® (Injecta Inc., Gunpo, Korea), a new polymethyl methacrylate product. Methods : A prospective, single-center, and single-arm clinical trial of 30 participants who underwent PVP using Spinofill® for painful thoracolumbar OVCF was performed with 6-months follow-up. Clinical and surgical outcomes included the Visual analog scale (VAS), Korean-Oswestry disability index (K-ODI), and Odom's criteria, complication rate, and recurrence rate. Radiological outcomes were evaluated by measuring the findings of postoperative computed tomography and simple radiograph. Results : The pain of VAS (from 8.95±1.05 to 4.65±2.06, p<0.001) and the life quality based on K-ODI (from 33.95±5.84 to 25.65±4.79, p<0.001) improved significantly, and successful patient satisfaction were achieved in 20 patients (66.7%) 1 day after surgery. These immediate improvements were maintained or more improved during the follow-up. There was no surgery- or product-related complications, but OVCF recurred in two patients (6.7%). Favorable cement interdigitation was reported in 24 patients (80.0%), and extra-vertebral cement leakage was reported in 13 patients (43.0%). The mean vertebral height ratio (from 60.49%±21.97% to 80.07%±13.16%, p<0.001) and segmental kyphotic angle (from 11.46°±8.50° to 7.79°±6.08°, p=0.002) improved one day after surgery. However, these short-term radiological findings somewhat regressed at the end. Conclusion : The overall outcomes of PVP using Spinofill® were as favorable as those of other conventionally used products.

Deep Learning-based Spine Segmentation Technique Using the Center Point of the Spine and Modified U-Net (척추의 중심점과 Modified U-Net을 활용한 딥러닝 기반 척추 자동 분할)

  • Sungjoo Lim;Hwiyoung Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.139-146
    • /
    • 2023
  • Osteoporosis is a disease in which the risk of bone fractures increases due to a decrease in bone density caused by aging. Osteoporosis is diagnosed by measuring bone density in the total hip, femoral neck, and lumbar spine. To accurately measure bone density in the lumbar spine, the vertebral region must be segmented from the lumbar X-ray image. Deep learning-based automatic spinal segmentation methods can provide fast and precise information about the vertebral region. In this study, we used 695 lumbar spine images as training and test datasets for a deep learning segmentation model. We proposed a lumbar automatic segmentation model, CM-Net, which combines the center point of the spine and the modified U-Net network. As a result, the average Dice Similarity Coefficient(DSC) was 0.974, precision was 0.916, recall was 0.906, accuracy was 0.998, and Area under the Precision-Recall Curve (AUPRC) was 0.912. This study demonstrates a high-performance automatic segmentation model for lumbar X-ray images, which overcomes noise such as spinal fractures and implants. Furthermore, we can perform accurate measurement of bone density on lumbar X-ray images using an automatic segmentation methodology for the spine, which can prevent the risk of compression fractures at an early stage and improve the accuracy and efficiency of osteoporosis diagnosis.

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • v.25 no.1
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy

  • Sang Hyup Lee;Hye Jin Yoo;Seung-Man Yu;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.126-133
    • /
    • 2019
  • Objective: To compare the lumbar vertebral bone marrow fat-signal fractions obtained from six-echo modified Dixon sequence (6-echo m-Dixon) with those from single-voxel magnetic resonance spectroscopy (MRS) in patients with low back pain. Materials and Methods: Vertebral bone marrow fat-signal fractions were quantified by 6-echo m-Dixon (repetition time [TR] = 7.2 ms, echo time (TE) = 1.21 ms, echo spacing = 1.1 ms, total imaging time = 50 seconds) and single-voxel MRS measurements in 25 targets (23 normal bone marrows, two focal lesions) from 24 patients. The point-resolved spectroscopy sequence was used for localized single-voxel MRS (TR = 3000 ms, TE = 35 ms, total scan time = 1 minute 42 seconds). A 2 × 2 × 1.5 cm3 voxel was placed within the normal L2 or L3 vertebral body, or other lesions including a compression fracture or metastasis. The bone marrow fat spectrum was characterized on the basis of the magnitude of measurable fat peaks and a priori knowledge of the chemical structure of triglycerides. The imaging-based fat-signal fraction results were then compared to the MRS-based results. Results: There was a strong correlation between m-Dixon and MRS-based fat-signal fractions (slope = 0.86, R2 = 0.88, p < 0.001). In Bland-Altman analysis, 92.0% (23/25) of the data points were within the limits of agreement. Bland-Altman plots revealed a slight but systematic error in the m-Dixon based fat-signal fraction, which showed a prevailing overestimation of small fat-signal fractions (< 20%) and underestimation of high fat-signal fractions (> 20%). Conclusion: Given its excellent agreement with single-voxel-MRS, 6-echo m-Dixon can be used for visual and quantitative evaluation of vertebral bone marrow fat in daily practice.

The effects of mandibular setback osteotomy on the oropharyngeal airway space in mandibular prognathic patients (하악전돌 환자에서 하악골 후퇴수술이 기도공간에 미치는 영향)

  • Kim, Hyo-Young;Choi, Hyun-Gue;Kim, Eun-Kyung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.733-741
    • /
    • 1997
  • As a result of surgical orthodontic treatment of mandibular prognathism, changes take place in the skeletal and soft orofacial components. Although some investigators had stated that permanent reduction of airway space was observed after mandibular setback surgery, it was not clear that this permanent reduction was sustained during long-term follow-up. The purpose of this study was to assess the changes in oropharyngeal airway space and soft tissue orofacial component following the mandibular setback surgery and during the follow-up period. The correlation between the changes of the oropharyngeal airway space and the changes of other soft tissue orofacial component was also assessed. The findings of this study were as follows ; 1. The oropharyngeal airway space area decreased following mandibular setback surgery for mandibular prognathism and continued to decrease during the follow-up period(p<0.05). 2. The pharyngeal depth at Xi point level and the 2nd cervical vertebra point level decreased after the surgery and remained during the follow-up period(p<0.05). The decrease of these pharyngeal depth was correlated with the decrease of oropharyngeal airway space area(p<0.01). 3. The decrease of pharyngeal depth at the 3rd and 4th cervical vertebra point level was not significant after the surgery and during the follow up period. 4. The hyoid bone moved downward after the surgery(p<0.05), but returned to its original position during the follow-up period. 5. The length & height of tongue and the Position of epiglottis base did not change significantly(p>0.05). 6. The soft palate was displaced posteriorly after the surgery and remained to its changed position during the follow-up period(p<0.05) due to posterior displacement of tongue. The changes of soft palate were significantly correlated with the decrease of oropharyngeal airway space area(p<0.01). 7. The narrowing of oropharyngeal airway space was due to the posterior displacement of tongue above the level of epiglottis tip. The posterior displacement of tongue following mandibular setback osteotomy remained during the follow-up period.

  • PDF