• 제목/요약/키워드: Venturi Effect

검색결과 54건 처리시간 0.024초

충격기류식 여과집진장치에서 벤츄리가 압력손실에 미치는 영향 (Prediction of Venturi Effect on Pressure Drop in Pulse Air Jet Bag Filter)

  • 정문섭;김정권;정용현;서정민
    • 한국환경과학회지
    • /
    • 제32권9호
    • /
    • pp.659-669
    • /
    • 2023
  • The purpose of this study is to predict the pressure drop due to the installation of venturi under diverse operating conditions such as dust concentration, pulse interval and pressure, and filtration velocity using algebraic-linear regression model and use it as an economic data and efficient operating condition for a pulse air jet bag filter. A pilot scale bag filter with a filter a filter size(Ø140 × 850ℓ, 12) was used, and the filters used in the experiment were the polyester filters most commonly used in real industrial sites. The SAS 9.4 program (SAS Institute, USA) was used to predict and to determine the effects of inlet concentration (Ci), pulse interval (Pi) and pressure (Pp), filtration velocity (Vf), presence or absence of venturi, etc. The results are shown below. The variation in pressure drop with or without venturi installation was 38.8 mmAq when venturi is installed and 47.6 mmAq when venturi is not installed, indicating a difference in pressure drop of 8.8 mmAq depending on venturi installation. It is estimated that the efficiency can be improved by about 18.5% if the venturi is installed.

타공 패널의 다공률에 따른 에너지 하베스팅에 관한 연구 (A Study on the Energy Harvesting according to the porosity of Perforated Panel)

  • 박하준;이민협;유무영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.113-114
    • /
    • 2023
  • As the available resources are gradually depleted, interest in renewable energy is increasing. Various energy harvesting technologies are emerging, and energy harvesting using solar, solar, and wind power is used in the highest range. Depending on the abnormal climate, solar heat and solar power differ in energy harvest, but the wind is fixed compared to the sun. Therefore, it was intended to maximize the effect of energy harvesting by using the venturi effect, which has a change in wind speed according to the turbine used for wind power generation and wind pressure. Therefore, in this paper, we want to see the difference in the amount of power generated by the turbine after increasing the wind speed using the venturi effect.

  • PDF

버터플라이 밸브의 유량측정 불확도에 대한 영향 (Effect of a Butterfly Valve on the Uncertainty of Flow Rate Measurement)

  • 윤석호;이정호;유청환;박상진;정장환
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.18-24
    • /
    • 2010
  • For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.

차압식 유량계에서 점탄성유체의 유출 및 손실계수 (Discharge and loss coefficients for viscoelastic fluids in differential pressure flow meters)

  • 전우청;조병수;백병준;박복춘
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1501-1509
    • /
    • 1996
  • Differential pressure devices such as an orifice and Venturi are widely used in the measurement of flow rate of fluid mainly due to cost effectiveness and easy installation. In the current study, the viscoelastic effect on discharge and loss coefficients of those flow meters were investigated experimentally. Aqueous solutions of Polyacrylamide (200, 500, and 800 ppm) as viscoelastic fluids were used. Discharge coefficient of an orifice for viscoelastic fluids increased significantly up to approximately 15-20% when compared with that for water, while loss coefficient decreased up to 10-25% depending on the diameter ratio, .betha.. Also, pressure recovery for viscoelastic fluids was extended much longer than that for water. On the other hand, discharge and loss coefficients of Venturi for viscoelastic fluids were found to be strongly dependent on the Reynolds number. In both flow meters, the concentration effect for discharge and loss coefficients was not observed at more over than 200 ppm of aqueous solution. Conclusively, orifice and Venturi flow meters should be calibrated very carefully in the flow rate measurement for viscoelastic fluids.

벤투리 효과를 활용한 도심형 건물용 하이브리드 풍력 및 태양광 발전 시스템 기초타당성 예비연구 (Preliminary Feasibility Study on Wind and Solar Hybrid Power Systems based on Venturi Effects for Buildings)

  • 김수현;김윤수;박수민;안지현;이상훈
    • 신재생에너지
    • /
    • 제19권1호
    • /
    • pp.22-30
    • /
    • 2023
  • Recently, the use of renewable energy has been increasing to achieve carbon neutrality. The concept of a zero-energy building is also attracting attention. In this study, a preliminary study was conducted to analyze the feasibility of a hybrid wind and solar power generation system between buildings that utilize the building wind generated by the Venturi effect. For this purpose, the wind speed and sunshine hours were monitored in the area where the building wind blows by the Venturi effect, and the power generation depending on system types, areas, and season was estimated. Consequently, the wind power generation system showed a larger amount of power per area than solar power. The wind power systems can generate larger power if wind power blades are installed along the height of the building. As a preliminary study, this study verified the feasibility of the system utilizing building wind and suggested follow-up studies.

Verification of Speed-up Mechanism of Pedestrian-level Winds Around Square Buildings by CFD

  • Hideyuki Tanaka;Qiang Lin;Yasuhiko Azegami;Yukio Tamura
    • 국제초고층학회논문집
    • /
    • 제11권4호
    • /
    • pp.301-314
    • /
    • 2022
  • Various studies have been conducted on pedestrian-level wind environments around buildings. With regard to the speed-up mechanism of pedestrian-level winds, there are references to downwash effect due to the vertical pressure gradient of boundary layer flow and venturi effect due to flow blocking by the building. Two factors contribute to increase or decrease of downwash effect: change in twodimensional / three-dimensional air flow pattern (Type 1) and change in downwash wind speed due to building size that does not accompany change in airflow pattern (Type 2). Previous studies have shown that downwash effect has a greater influence in increasing or decreasing the area of strong wind than venturi effect. However, these considerations are derived from the horizontal mean wind speed distribution at pedestrian level and are not the result of three-dimensional flow field around the building. Therefore, in this study, Computational Fluid Dynamics using Large Eddy Simulation were performed to verify the downwash phenomena that contributes to increase in wind speed at pedestrian level.

산소부화와 유인공기를 이용한 벤츄리형 후연소기의 오염물질 저감에 관한 연구 (A Study on the Pollutants Reduction of Venturi Type After-burner by oxygen enrichment and Induced Air)

  • 오세원;박준홍;이용후;이진석;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권7호
    • /
    • pp.845-851
    • /
    • 2003
  • The purpose of this experimental study is to investigate the quantitative pollutants reduction by oxygen enrichment and induced air effect in venturi type after-burner. For this purpose, CO, $CO_2$, $O_2$. and HC concentrations were measured before and after the after-burner by changing the Oxygen flow rate and area ratio which is defined as the ratio of air inducing area divided by total area. As results of this study, when the area ratio were increased, the emission reduction effect was increased even less oxygen flow rate. In that case when oxygen was injected too little, the pollutants were increased.

대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구 (Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites)

  • 이창우;웅웬반득
    • 터널과지하공간
    • /
    • 제24권6호
    • /
    • pp.464-472
    • /
    • 2014
  • 환기제어 시설을 설치하지 않고 모든 공간을 개방한 형태의 대단면 주방식 채굴 작업장에 설치하는 국부선풍기의 운전에 따른 기류유동형태는 재순환을 포함하고 있어 복잡하고 정량화가 어렵고 환기효율 또한 매우 낮은 편이다. 본 논문에서는 국부선풍기의 운전에 따라 하류편의 기류 운동에너지 증가 및 정압강하 현상인 벤츄리(venturi) 효과로 인접갱도로부터 기류가 유입되어 기류 유동방향으로 환기량이 증가하는 현상을 선풍기 종류 및 설치방법 별로 CFD분석하였다. 분석대상 선풍기는 축류선풍기 1종류 및 프로펠러 선풍기 2종류이며 축류선풍기 중심점 설치 위치를 1.0, 1.5, 2.0m로 변경함에 따른 벤츄리 효과의 차이를 분석하였다. 연구결과는 공기질 개선을 통한 작업환경 관리를 위한 국부 환기의 경제성 및 효율성을 제고하는데 기여할 것으로 기대된다.

선회유동 교란에 따른 벤투리 유량측정의 불확실성 해석 (Effect of Swirl Flow Disturbance on Uncertainty of Flow Rate Measurement by Venturi)

  • 이정호;윤석호;유청환;박상진;정장환
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.18-25
    • /
    • 2009
  • Venturi has long been an attractive method of measuring flow rate in a variety of engineering applications since pressure loss is relatively small compared with other measuring methods. The current study focuses on making detailed uncertainty estimations as the upstream flow disturbance affects uncertainty levels of the flow rate measurement. Upstream flow disturbance can be determined by 9 different swirl generators. Measurement uncertainty of flow rate has been estimated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard. The results of flow rate uncertainty analysis show that the case with systematic error has higher than that without systematic error. Especially the result with systematic error exhibits that the uncertainty of flow rate was gradually increased by swirl flow disturbance. The uncertainty of flow rate measurement can be mainly affected by differential pressure and discharge coefficient. Flow disturbance can be also reduced by increasing of the upstream straight length of Venturi.

캐비테이션 벤튜리의 유량제어 성능 (Performance of Flow Rate Control of a Cavitating Venturi)

  • 조원국;문윤완;김영목
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.146-151
    • /
    • 2002
  • Characteristics of flow rate control has been studied for a cavitating venturi adopted in a liquid rocket propellant feed system. Numerical simulation has been peformed to give about $10\%$ discrepancy of mass flow rate to the experimental data for cavitating flow regime. Mass flow rate is confirmed to be saturated for pressure difference higher than $3\times10^5$pa when the upstream pressure is fixed to $22.8\times10^5$pa and the downstream pressure is varied. The evaporation amount depends substantially to non-condensable gas concentration. However the mass flow rate characteristic is relatively insensitive to the mass fraction of non-condensable gas. So it is reduced by only $2\%$ when the non- condensable gas concentration is increased from 1.5PPM to 150PPM. From the previous comparison the expansions of the non-condensable gas and the evaporation of liquid are verified to have same effect to pressure recovery.

  • PDF