• Title/Summary/Keyword: Ventilators, mechanical

Search Result 51, Processing Time 0.023 seconds

A Study on the Application of Ventilation Equipment in an Underground Fire (지하공간 화재시 배연장비의 활용에 관한 연구)

  • Lee, Sung-Ryong;Han, Dong-Hoon
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.92-96
    • /
    • 2010
  • In this study, experiments were conducted to evaluate the effectiveness of ventilation equipment in underground fires. Two type of Ventilators were used in experiments. Experiments were carried out using ethanol square pool fire. Maximum heat release rate was about 460kW. Visibility and temperature distribution were evaluated according to mechanical ventilation. In blower type ventilation, visibility was increased and temperature was lowered.

Uncertainty Analysis of Test Method for Heat Recovery Ventilators (폐열회수 환기유닛의 인증시험 방법에 대한 오차분석)

  • Han, H.;Choo, Youn-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.423-428
    • /
    • 2006
  • Twenty nine HRV models have been tested for last two years since the attestation system has been started by KARSE. It is the objective of the present study to analyze the performance test results. Uncertainty analysis has been conducted to find the effects of measured variables on the uncertainties of test results. The uncertainty of enthalpy is found to be affected by the uncertainty of wet bulb temperature significantly, but not by that of dry bulb temperature for the present range of parameters. The uncertainty of effective enthalpy efficiency is calculated to be 6%P for the cooling condition, and 3%P for the heating condition approximately. In order to reduce the uncertainty of the test results, the uncertainty of wet bulb temperature should be minimized and the indoor/outdoor test conditions should be modified so as to increase the enthalpy difference.

  • PDF

Pneumonia Incidence Varies by Tracheal Suction Procedures among Caregivers of Patients with Home Mechanical Ventilators (가정용 인공호흡기 적용 신경근육계 희귀난치성 질환자 가족 간호제공자의 기관내 흡인 수행과 폐렴 발생과의 관계)

  • Hwang, Moon Sook;Park, Jin Hee
    • Journal of Home Health Care Nursing
    • /
    • v.23 no.1
    • /
    • pp.25-33
    • /
    • 2016
  • Purpose: This study aimed to survey caregivers of patients with Neuromuscular Rare and Incurable Disease (NRID) using invasive home mechanical ventilator (HMV), in order to compare the incident rate of pneumonia by tracheal suction procedures used. Method: Participants were 99 family caregivers of NRID patients using HMV. Participants were given a questionnaire consisting of 12 demographic items, 10 items about disease and HMV related characteristics, 11 items about tracheal suction procedures, and 2 items about the incidence of pneumonia. Data were analyzed using chi-square tests and t-tests. Results: The items that predicted the incidence of pneumonia were "change of irrigation saline every suction" (p=.047), "use of aseptic catheter every suction" (p=.004), and "instillation of normal saline before suction" (p=.027). In addition, these items were 47.4%, 51.4%, and 38.8% respectively. Conclusion: Family members caring for NRID patients with invasive HMV should be educated about tracheal suction, especially the necessity of changing irrigation saline after every suction, using the aseptic catheter for every suction, and instillation of normal saline before suction. Medical personnel such as home care nurses should periodically check tracheal suction procedures, and re-educate family caregivers when necessary.

A Study on the Development of Heat-Recovery Ventilator for Preventing Freezing in a Cold Weather (혹한기 결빙 방지를 위한 열회수형 환기장치 개발에 관한 연구)

  • Park, Woo-Cheul;Kim, Il-Gyoum;Tae, Kyung-Eung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.593-598
    • /
    • 2018
  • Computational fluid dynamics was used to develop a heat-recovery ventilator for preventing freezing in cold weather. An optimal internal return damper was applied, and a prototype was made for frost and freezing experiments. A total of 16 models were used to design the optimal internal return damper with the maximum exhaust recirculation ratio. The exhaust recirculation ratio of the exhaust air to the outdoor air was 59.9-62.3%. The tests showed that frost and freezing did not occur at outdoor air temperatures of $-15^{\circ}C$ or higher in both exhaust recirculation operation and normal operation. However, at an outdoor air temperature of $-20^{\circ}C$, no freezing occurred in the outdoor air area when the internal return damper was opened by 45 degrees. Heat recovery ventilators for preventing cold weather frost and freezing should be operated in two operation modes: normal and exhaust recirculation mode. An operating algorithm was developed for the heat-recovery ventilator operating in normal mode when the outdoor temperature is higher than $-15^{\circ}C$ and recirculation mode when the temperature is lower.

Preference and Performance Fidelity of Modified Korean Physician Order for Life-Sustaining Treatment (MK-POLST) Items in Hospice Patients with Cancer (수정된 한글 연명의료계획서(Modified Korean Physician Order for Life-Sustaining Treatment, MK-POLST) 분석을 통한 호스피스 병동 환자의 의료 중재 항목별 선호도 및 충실도 조사)

  • Han, Ji Hee;Chun, Hye Sook;Kim, Tae Hee;Kim, Rock Bum;Kim, Jung Hoon;Kang, Jung Hun
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.4
    • /
    • pp.198-206
    • /
    • 2019
  • Purpose: The Act on Hospice and Palliative Care and Decisions on Life-sustaining Treatment for Patients at the End of Life was enacted in 2016 and has taken effect since 2018 February. The content of this act was based on Physician Orders for Life-Sustaining Treatment (POLST) in the United States and we modified it for terminal cancer patients registering hospice. The object of this study is to investigate preference and implementation rate for modified Korean POLST (MMK-POLST) items in hospice ward. Methods: From February 1, 2017 to April 30, 2019, medical records regarding MMK-POLST were retrospectively analyzed for all patients hospitalized in the hospice ward of Gyeongsang National University Hospital. Results: Of the eligible 387 total cohorts, 295 patients filled out MK-POLST. MK-POLST has been completed in 133 cases (44.1%) by the patient themselves, 84 cases (28.5%) by the spouse, and 75 cases (25.4%) by their children, respectively. While only 13 (4.4%) out of 295 MK-POLST completed patients refused the parenteral nutrition and 5 patients (1.7%) for palliative sedation, the absolute majority of 288 (97.6%) patients did not want cardiopulmonary resuscitation (CPR) and ventilators and 226 people (76.9%) for pressor medications. Kappa values for the matched strength of MK-POLST implementation were poor for all items except CPR, ventilators and palliative sedation. Conclusion: Hospice patients refused to conduct cardiopulmonary resuscitation, ventilators and pressor agents. In contrast, antibiotics, parenteral nutrition and palliative sedation were favored in the majority of patients.

Patient Discomfort Caused by an Endotracheal Tube during Ventilator Therapy after Cardiac Surgery (심장 수술 후 인공호흡기 치료를 받는 환자의 기관내관으로 인한 불편감에 관한 연구)

  • Hyun, A-Reum;Choe, Myoung-Ae
    • Journal of Korean Critical Care Nursing
    • /
    • v.3 no.1
    • /
    • pp.53-65
    • /
    • 2010
  • Purpose: The purpose of this study was to identify the intensity and types of discomfort caused by an endotracheal tube in patients during ventilator therapy after cardiac surgery, and to analyze the differences in the intensity and types of discomfort by sociodemographic and clinical characteristics and characteristics related to endotracheal tubes. Methods: The intensity of discomfort was measured using an 11-point numeric rating scale and the types of discomfort were measured using a 4-point numeric rating scale. Sociodemographic and clinical characteristics and characteristics related to endotracheal tube were collected by observation and the electronic medical chart using a structured questionnaire. Results: The mean intensity of discomfort in patients due to endotracheal tubes was 6,91 points, 84% of patients reported discomfort over 5 points, The most severe discomfort was pain during endotracheal suctioning, and dry mouth and breathing difficulties were also found to induce discomfort. Patients who had more severe surgical site pain, longer duration of intubation and higher cuff pressure demonstrated more severe discomfort due to the endotracheal tube. Conclusion: These results can be used as basic data for developing nursing intervention to relieve the discomfort caused by endotracheal tubes in patients during ventilator therapy.

  • PDF

A Study on the Characteristics of Environment-friendly Skins of European Housing - Focused on the Structural Characteristics of the skins - (유럽 집합주택을 대상으로 한 환경친화적 외피의 특성 분석 - 외피의 구축적 특성에 따른 유형별 분석을 중심으로 -)

  • Won, Hyun Seong;Kim, Jin Woo;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.11-18
    • /
    • 2008
  • The purpose of this study is to analyze application methods and structural characteristics of each element of environment-friendly European housing through classification of skin types. The results of the study are following. 1) The skins are classified by three types; single skin with multi layers, double skin with single layer and double skin with multi layers. 2) Most single skins with multi-layer are composed with wooden louvers, sun blinds and insulating windows. There are introduction of atrium and balcony, and variation sectional space composition according to cases. 3) There are two types of double skins; to put cavity between inner skin and outer skin and more extensional spaces such as balconies, corridors and stair halls. Solar walls and mechanical ventilators are often introduced to double skins with multi-layer. 4) The functions of the latest environment-friendly skins are vary from controllers and buffers of indoor environmental elements such as temperature, light, air and sound to equipments to perform essential functions to efficiently operate HVAC systems.

Evaluation of Clinical Alarms and Alarm Management in Intensive Care Units (중환자실에서 사용되는 의료장비의 경보음 발생과 관리 현황)

  • Jeong, Yu Jin;Kim, Hyunjung
    • Journal of Korean Biological Nursing Science
    • /
    • v.20 no.4
    • /
    • pp.228-235
    • /
    • 2018
  • Purpose: This study aimed to investigate the clinical alarm occurrence and management of nurses toward clinical alarms in the intensive care unit (ICU). Methods: This observational study was conducted with 40 patients and nurses cases in two ICUs of a university hospital. This study divided 24 hours into the unit of an hour and conducted two times of direct observation per unit hour for 48 hours targeting the medical devices applied to 40 patients. Data were analyzed using IBM SPSS Statistics 23. Results: On average, 3.8 units of medical devices were applied for each patient and the ranges of alarm settings were wide. During 48 hours, 184 cases of clinical alarm were occurred by four types of medical devices including physiological monitors, mechanical ventilators, infusion pumps, and continuous renal replacement therapy. Among them, false alarm was 110 cases (59.8%). As for the alarm management by ICU nurses, two-minute alarm mute took up most at 38.0% (70 cases), and no response was second most at 32.6% (60 cases). When valid alarm sounded, nurses showed no response at 43.2%. Conclusion: The findings suggest that a standard protocol for alarm management should be developed for Korean ICU settings. Based on the protocol, continuous training and education should be provided to nurses for appropriate alarm management.

The Effects of Chest Physiotherapy on Applied to Patients Mechanicalventilated - In Patients with Acute Lung Injury (흉부물리요법이 인공호흡기 적용 환자에게 미치는 효과 - 급성 폐손상 환자를 대상으로)

  • Lee, Moon Kyung;Lee, Hyeon Joo;Park, Hyo jin
    • Journal of Korean Critical Care Nursing
    • /
    • v.12 no.3
    • /
    • pp.61-73
    • /
    • 2019
  • Purpose : The purpose of this study was to examine the effects of two single chest physiotherapies mechanically ventilated patients with acute lung injury. Method : Participants were 30 ICU patients depending entirely on ventilators without self-respiration. Each patients received two single chest physiotherapiesvibration palm cup percussion at hour intervals. Data were analyzed one-way ANOVA and Wilcoxon signed-rank test. Statistical significance was accepted at a p value less than .05. Results : ibration therapy, dynamic compliance and statics compliance demonstrated a significant increase immediately and remained increased until 30 minutes after chest physiotherapy. palm cum percussion therapy saturation showed a significant increase immediately chest physiotherapyut there were no significant differences in tidal volume, dynamic compliance and statics compliance. Conclusion : In this study, we analyzed the effects of oscillation method and palm cup percussion method separately for each type of chest physiotherapy. Nursing interventions that actively utilize vibration methods should be provided to patients with respiratory diseases.

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.