• Title/Summary/Keyword: Ventilation volume

Search Result 310, Processing Time 0.027 seconds

The Froude Scaling Study on the Ventilation of Non-isothermal Concentrated Fume from the Semi-closed Space (반밀폐형 공간에서 비등온 고농도 연무의 배연산출량 산정을 위한 Froude 상사연구)

  • Chang, Hyuk-Sang;Choi, Byung-Il;Park, Jae-Cheul;Kim, Myung-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.877-885
    • /
    • 2005
  • The Froude scaling between the prototype and the model was tried to estimate the necessary ventilation rate for non-isothermal concentrated fume from the semi-closed inner space. Based on the non-dimensional similitude equations derived from the Zukoski plume rise analysis, the scaling experiments were done to verify the relationship of the non-dimensional energy release rate and the non-dimensional mass flow rate by using two different scaled volume models, model A ($1\;m{\times}1\;m{\times}1\;m$) and model B ($0.5\;m{\times}0.5\;m{\times}0.5\;m$). The experimental results showed that the theoretical similitude between the models is acceptable for the prediction of ventilation rate of the concentrated fume. The maximum energy release rate used for the experiments was $20\;kW/m^3$. In the experimental range, the similitude between the energy release rate and the ventilation mass flow rate was well defined and the necessary ventilation rates were 20-30% higher than the stoichiometric ventilation mass flow rate. Based on results of current study, the design of the local air ventilation system can be improved by correcting the effects of buoyancy and diffusion of the non-isothermal concentrated fume.

Estimation of Ventilation Rates in Korean Homes Using Time-activity Patterns and Carbon Dioxide (CO2) Concentration (시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정)

  • Park, Jinhyeon;Ryu, Hyeonsu;Heo, Jung;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.

Simulation study for Bag-Valve-Mask application guideline on pathologic pulmonary condition (모형폐의 물리적 특성 변화에 따른 Bag-Valve-Mask의 사용방법 연구)

  • Choi, Hae-Kyung;Jung, Hyung-Keon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.17 no.3
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: The purpose of this study is to get basic user guidelines of safe and efficient bag-valve-mask application on patients having abnormal pathophysiological pulmonary conditions. Methods: This study was performed by pre-qualified 35 EMS junior and senior students. Participants were instructed to compress ambulatory bag randomly about half, one-third, one-fourth within different airway resistance and pulmonary compliance. Resultant tidal volume and pulmonary wedge pressures on RespiTranier monitor were analysed in relation to pulmonary physiologic index. Results: At least over half compression of bag guaranteed minimal tidal volume regardless of pulmonary conditions. There was no increase of pulmonary wedge pressure above the level of barotrauma on half compression at any pulmonary conditions. Conclusion: Assisted ventilation with ambulatory bag on patients with pathological pulmonary conditions should be over half compressed regardless of respiratory disease entity.

The Effect of Building Morphology on Sea Breeze Penetration over the Kanto Plain - Analysis of Mean Kinetic Energy Balance of Moving Control Volume along Sea Breeze -

  • Sato, Taiki;Ooka, Ryozo;Murakami, Shuzo
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.73-80
    • /
    • 2012
  • In order to use sea breezes to counter the heat island phenomena, i.e. to promote urban ventilation, it is necessary to clarify the effect of building morphology and height on large-scale wind fields. In this study, the sea breeze in the vicinity of the Kanto Plain in Japan is simulated using a mesoscale meteorological model incorporating an urban canopy model, and the inland penetration of sea breezes is accurately reproduced. Additionally, a mean kinetic energy balance within a domain (Control Volume; CV) moving along the sea breeze is analysed. From the results, it is clarified that the sea breeze is interrupted by the resistance and turbulence caused by buildings at the centre of Tokyo. The interruption effect is increased in accordance with the height of these buildings. On the other hand, adverse pressure gradients interrupt in the internal region.

THE NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE IN TUNNEL (터널 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구)

  • Ahn, Hyuk-Jin;Jung, Jae-Hyuk;Hur, Nahm-Keon;Lee, Moon-Kyu;Yong, Gee-Joong
    • Journal of computational fluids engineering
    • /
    • v.15 no.2
    • /
    • pp.47-54
    • /
    • 2010
  • In the present study, a numerical simulation for the diffusion of hydrogen leakage of FCV(Fuel Cell Vehicle) in a tunnel was performed to aid the assessment of risk in case of leakage accident. The temporal and spatial distributions of the hydrogen concentration around FCV are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of tunnel ventilation system for relieving the accumulation of the leaked hydrogen gas. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

NUMERICAL STUDY FOR COOLING CAPACITY IMPROVEMENT OF ENGINE ROOM ENCLOSURE SYSTEM (엔진실 차폐 시스템의 냉각성능 개선을 위한 수치적 연구)

  • Bae, Y.S.;Yoo, G.J.;Choi, H.K.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.39-45
    • /
    • 2009
  • In engine room, proper enclosure system is preferable for reducing noise level but the enclosure system in the engine room causes bad influence on cooling performance due to poor ventilation. Cooling efficiency of the enclosure system can be improved by varying fan speed and proper flow path for ventilation. In this study, numerical analysis is performed to assess cooling effect of the enclosure system using finite volume method. The RNG k-$\varepsilon$ model is adopted for turbulence model along with heat exchanger model and porous media model for heat exchanger analysis, and moving reference frame model for rotational fan. Verification result shows reasonable agreement with experimental data. Analysis results show direct effect of velocity and temperature distribution on cooling ability in the enclosure system. Enclosure system of case B shows high heat transfer coefficient and has the smallest area ratio of opened flow passages which is good for noise level reduction.

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

Effects of Matrix Metalloproteinase Inhibitor on Ventilator-Induced Lung Injury in Rats (기계환기로 인한 백서의 급성 폐손상에서 Matrix Metalloproteinase Inhibitor의 효과)

  • Kim, Je-Hyeong;Park, Soo-Yeon;Hur, Gyu-Young;Lee, Seung-Heon;Lee, Sang-Yeub;Park, Sang-Myeon;Suh, In-Bum;Shin, Chol;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.619-634
    • /
    • 2002
  • Background : Many inflammatory mediators and collagenases are involved in the pathogenesis of acute lung injury (ALI) and acute respiratory distress syndrome (ARDS). The increase of matrix metalloproteinase-9 (MMP-9, gelatinase-B) produced mainly by inflammatory cells was reported in many ALI models and connective tissue cells. In this study, the expression of MMP-9 in ventilator-induced lung injury (VILI) model and the effects of matrix metalloproteinase inhibitor (MMPI) on VILI were investigated. Methods : Eighteen Sprague-Dawley rats were divided into three groups: low tidal Volume (LVT, 7mL/Kg tidal volume, 3 $cmH_2O$ PEEP, 40/min), high tidal volume (HVT, 30mL/Kg tidal volume, no PEEP, 40/min) and high tidal volume with MMPI (HVT+MMPI) groups. Mechanical ventilation was performed in room air for 2 hours. The 20 mg/Kg of CMT-3 (chemically modified tetracycline-3, 6-demethyl 6-deoxy 4-dedimethylamino tetracycline) was gavaged as MMPI from three days before mechanical ventilation. The degree of lung injury was measured with wet-to-dry weight ratio and acute lung injury score. Expression of MMP-9 was studied by immunohistochemical stain with a mouse monoclonal anti-rat MMP-9 $IgG_1$. Results : In the LVT, HVT and HVT+MMPI groups, the wet-to-dry weight ratio was $4.70{\pm}0.14$, $6.82{\pm}1.28$ and $4.92{\pm}0.98$, respectively. In the HVT group, the ratio was significantly higher than other groups (p<0.05). Acute lung injury score measured by five-point scale was $3.25{\pm}1.17$, $12.83{\pm}1.17$ and $4.67{\pm}0.52$, respectively. The HVT group was significantly damaged by VILI and MMPI protects injuries by mechanical ventilation (p<0.05). Expression of MMP-9 measured by four-point scale was $3.33{\pm}2.07$, $12.17{\pm}2.79$ and $3.60{\pm}1.95$, respectively, which were significantly higher in the HVT group (p<0.05). Conclusion : VILI increases significantly the expression of MMP-9 and MMPI prevents lung injury induced by mechanical ventilation through the inhibition of MMP-9.

Analysis of the Factors influencing the performance of Cardiopulmonary Resuscitation (심폐소생술 수행에 영향을 미치는 요인 분석)

  • Choi, Keun-Myung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.55-78
    • /
    • 2005
  • The purpose of this study was to provide basic data for the improvement of the guidelines and training programs regarding the cardiopulmonary resuscitation performance of bystanders who can respond to the incidents in earlier times as the first responder of the cardiac arrest incident, by reviewing the performance of basic CPR and the influencing factors after providing 70 students of Department of Emergency Medical Technology with the CPR training. For the purpose of the study, the collected data were computerized and analyzed by SPSS-WIN program(ver. 10.1). The results for this study were as follows The duration of session between the groups in the BLS CPR were 3 minutes and 36 seconds, 2 minutes and 32 seconds respectively. The average compression number per minute were 24.3 times and 33,2 times respectively(p=.000), and the average compression rate per minute were 112 times and 122 times respectively(p=.000). The average ventilation number per minute were 3.54 times and 5.1 times respectively(p=.000). The errors in compression "Too shallow" were 20.73 times(34.6%) and 23,23 times(38,7%) out of 60 times in 4 cycles with the standard of 38 nun. In CPR performance results according to gender in the first episode, males showed better results in compression depth as 41.5 mm comparing to females average 38.2 mm(p=.015). When ventilation results were compared according to the use of FS, the average ventilation number per minute, total ventilation per minute and the average volume per episode were significantly higher when FS was not used(<.040), There was no significant difference in ventilation accuracy between two groups. According to the results, we need to improve and distribute portable barrier devices, and to be familiar with those devices. We need to enforce ventilations as well as to include compressions so that faster and more accurate CPR can be performed. Additionally, we need to exclude ventilation only cases, minimize the interference time of chest compression due to inaccurate ventilation, simplify or minimize the complicatedness of CPR performance and responding time related to breathing, provide first responders with various training programs such as initial assessment and ventilations only, or initial assessment and chest compression-only CPR and than provide advanced training with AHA BLS education including CPR for more than two people according to CPR skills and target characteristics.

  • PDF