• 제목/요약/키워드: Ventilation system air flow rate

검색결과 82건 처리시간 0.05초

강제 환기식 육계사 다중 입기 슬롯에서의 입기류 도달거리 분석 (Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House)

  • 권경석;하태환;이인복;홍세운;서일환
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.55-65
    • /
    • 2012
  • In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption, occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

단면형상 변화에 따른 전열교환기 열전달 특성변화에 대한 연구 (Heat Transfer Performance of the Duct with Various Cross Section in Heat Exchanger)

  • 김응복;한민섭;김내현;원태연
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.322-327
    • /
    • 2010
  • It is a critical task to keep the ventilation system working in a proper and efficient manner in large multi-storey buildings, and the enthalpy exchanger is becoming an increasingly important part of the ventilation system by playing the function of channeling heat and moisture. We present a computational study on the heat transfer performance of the cross-flow enthalpy exchanger, which is in large use for residential buildings. The ducts are considered whose cross-sectional shapes resemble triangle and longitudinal centerline a cosine wave. It is shown that, as the cross-sectional shape departs from triangle, the heat transfer performance of the duct tends to deteriorate. Also, applying the wave-like shape to the longitudinal centerline of the duct increases the rate of heat transfer and the applied pressure-gradient at the same time. The origin of the performance variations in the cases considered are quantitatively analyzed and discussed.

철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구 (A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel)

  • 유지오;김진수;서종원
    • 한국터널지하공간학회 논문집
    • /
    • 제19권6호
    • /
    • pp.845-856
    • /
    • 2017
  • 초장대 철도터널에서는 화재 시 안전성 확보를 위해서 구난역을 설치하도록 하고 있으나, 구난역에서 제연방식 및 제연풍량에 대한 기준이나 연구결과는 없는 실정으로 제연방식과 적정풍량에 대한 연구가 필요한 실정이다. 이에 본 연구에서는 서비스터널이나 상대터널과 연결하는 피난연결통로가 일정간격(40 m 간격)으로 설치된 구난역을 모델링하고 화재강도(15, 30 MW), 제연방식(급기만하는 경우, 강제급배기를 하는 경우, 강제배기만을 하는 경우), 제연풍량(7, 14, $40m^3/s$)을 변화시켜 화재해석을 수행하였다. 화재해석결과로 부터 구난역 승강장의 온도 및 CO농도를 분석하고 한계온도 기준 ASET을 비교 분석하였다. 그 결과, 화재강도가 15 MW일 때에는 제연풍량이 $7m^3/s$ 이상인 경우에 강제급배기하는 방식과 강제배연을 하는 방식을 적용하면 충분히 안전한 대피환경을 확보할 수가 있는 것으로 나타났다. 또한 화재강도가 30 MW인 경우에는 배연풍량이 $14m^3/s$ 이하에서는 900초 이상 대피환경을 유지하는 것이 불가능하며, 풍량이 $40m^3/s$일 때에는 상부덕트의 측면부에서 배기하는 경우(SA + EA2, SA + EA4)가 온도측면에서 안전성 확보에 가장 유리한 것으로 나타나고 있다.

육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구 (Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea)

  • 송준익;유용희;정종원;김태일;최희철;강희설;양창범;이영윤
    • 한국축산시설환경학회지
    • /
    • 제10권2호
    • /
    • pp.93-100
    • /
    • 2004
  • 본 연구는 우리나라에 건축되어져 있는 개방식 육성$\cdot$비육돈사나 무창식 육성$\cdot$비육돈사에 대한 효율 비교분석 연구가 없는 실정으로 개방식 육성$\cdot$비육돈사와 무창식 육성$\cdot$비육돈사의 환경효율을 검증하고자 하였다. 겨울철과 여름철로 나누어 실시한 실험결과는 다음과 같다. 1. 무창식 육성 비육돈사는 외부의 기온 변화가 심하더라도 돈사내부의 온도는 외부기온의 영향을 받지 않고 여름철 $31.8\~33.8^{\circ}C$, 겨울철 $17.9\~19.5^{\circ}C$를 유지하였으나 개방식 육성$\cdot$비육돈사는 여름철 32.1$\~$32.9, 겨울철 $15.8\~16.7^{\circ}C$를 유지하여 온도효율이 낮았다. 2. G2, G4 육성$\cdot$비육돈사는 돼지생활 공간(하부) 지점에서의 공기유속은 겨울철 최소환기($5\%$) 수준으로 하였을 때 0.2$\~$0.3 m/s 였으며, 여름철 최대환기($95\%$) 수준에서는 0.5$\~$0.6 m/s로 분포되어 여름철 및 겨울철의 육성$\cdot$비육돈사내 공기유속이 G1, G3 육성$\cdot$비육돈사보다 양호하였다. 3. 암모니아 농도를 측정한 바 G2, G4 육성$\cdot$비육돈사는 여름철 13.3$\~$16.6 ppm, 겨울철14.0$\~$~14.6 ppm으로 측정되었으며, G1, G3 육성$\cdot$비육돈사는 여름철 14.6$\~$20.3 ppm, 겨울철 20.3$\~$25 ppm을 유지하여 G1, G3 육성$\cdot$비육 돈사보다는 낮게 나타났다.

  • PDF

열교환기 형상에 따른 분리형 히트파이프 성능 비교 (Separate type heat pipe performance comparison by the heat exchanger shapes)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.723-729
    • /
    • 2016
  • 본 연구에서는 핀-관형 히트파이프와 평행류형 히트파이프 제작하여 시험하였으며 분리형 히트파이프의 작동유체의 충진량은 40~60(% vol.), 풍량은 300~1,400 사이에서 변화시켜가며 온도교환 효율, 열회수량, 공기측 압력강하를 비교하였다. 온도교환 효율은 두 종류의 히트파이프 모든 경우에서 저 풍량에서는 작동유체 충진량이 40(%vol.)일 때가 가장 높았으며 풍량이 증가함에 따라 최대 효율을 가지는 작동유체 충진량이 다름을 알 수 있었고, 환기량이 작을수록 온도교환 효율이 높게 나타났다. 평행류형 히트파이프 60(%vol.)의 실험결과에서 보는 것과 같이 작동 유체를 너무 많이 충진하게 되면 오히려 낮은 온도교환 효율을 보이는데 이는 관벽의 액막이 두터워지면서 열전달 효과를 악화시킨 결과로 최적 충진량이 40~50(%vol.) 사이에 있음을 알 수 있다. 풍량 변화에 따른 공기측 압력강하 비교에서는 증발부 히트파이프가 응축부 히트파이프 보다 크게 계측 되었는데 증발부 표면에 생긴 결로수의 영향으로 생각된다. 평행류형 히트파이프는 핀-관형 히트파이프와 비교하여 냉매 충진량은 48%, 체적은 41%에서 동등이상의 성능을 보였으며, 공기측 압력강하도 37% 정도로 좋은 성능을 나타내었다.

전자산업 청정실의 작업환경 및 유해물질농도 평가 (Assessment of hazardous substances and workenvironment for cleanrooms of microelectronic industry)

  • 정은교;박현희;신정아;장재길
    • 한국산업보건학회지
    • /
    • 제19권3호
    • /
    • pp.280-287
    • /
    • 2009
  • High-tech microelectronics industry is known as one of the most chemical-intensive industries. In Korea, Microelectronics industry occupied 38% of export and 16% of working employees work in microelectronics industry. But, chemical information and health hazards of high-tech microelectronics manufacturing are poorly understood because of rapid development and its penchant for secrecy. We need to investigate on chemical use and exposure control. We Site-visits to 6 high-tech microelectronics manufacturing company which have cleanroom work using over 1,000kg organic solvents (5 semi-conductor chips and its related parts company, 1 liquid crystal display (LCD)). We reviewed their data on chemical use and ventilation system, and measured TVOCs (Total Volatile Organic Compounds) and carbon dioxide concentration. All cleanroom air passed through hepa filters to acheive low particle levels and only 1 cleanroom uses carbon filters to minimize the organic solvents exposures In TVOC screening test, Cleanroom for semi-conductor chips and its related parts company with laminar down flow system (e.g. class 1~100) showed nondetectable level of TVOCs concentration, but Cleanroom for liquid crystal display (LCD) with conventional flow system (e.g. class 1,000~10,000) showed 327 ppm as TVOCs. Acetone concentration in cleanroom for Jig cleaning, LC Injection, Sealing processes were 18.488ppm (n=14), 49.762 ppm (n=15), 8.656 ppm (n=14) as arithmetric mean. Acetone concentration in cleanroom for LCD inspection process was 40ppm (n=55) as geometric mean, where the range was 7.8~128.7ppm and weakly correlated with ventilation rate efficiency(r=0.44, p<0.05). To control organic solvents in cleanrooms, chemical and carbon filters should be installed with hepa filters. Even though their volatile organic compounds concentration was not exceed to occupational exposure limits, considering of entrance limited cleanroom environment, long-term period exposure effects and adverse health effects of cleanroom worker need further reseach.

고속전철용 압력완화장치 설계기술 개발 (Development of the Design Technology for the Pressurization Equipments of High Speed Train)

  • 염한길;박성제;고득용
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.21-37
    • /
    • 1998
  • 차내의 압력변동은 터널 주행시 압력파로 인한 터널 내부의 압력 변동이 열차 내부로 전달되는 것으로, 차내부로 유입되는 공기량과 차외부로 유출되는 공기량의 불균형으로 야기된다. 이러한 차내의 압력변동은 그 압력의 절대치와 압력변동 속도에 의해 승객에게 불쾌감을 주는 이명현상을 일으킨다. 이러한 불쾌감을 줄이기 위해 새로운 환기시스템을 설계..제작하여 성능시험을 실시하였다. 이 시스템은 차내.외의 압력차를 감지하여 급.배기 송풍기의 회전수와 제어밸브개도를 조절함으로써 차내의 압력변동을 일정한 범위이하로 제어한다. 성능실험 결과 본 시스템이 차내 압력변동을 제어하여 불쾌감을 주는 이명현상 제거하는데 효과가 있음을 확인하였다. 따라서 본 시스템을 350km/h로 달리는 경부고속전철(TGV-K)에 적용할 수 있을 것으로 기대된다.

  • PDF

원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구 (A Study on Construction and Application of Nuclear Grade ESF ACS Simulator)

  • 이숙경;김광신;손순환;송규민;이계우;박정서;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.319-327
    • /
    • 2010
  • 공학적 안전설비 공기정화계통과 관련된 실험 수행을 위해 원자력등급 ESF 공기정화계통 시뮬레이터를 설계, 제작, 검증하였다. 영광 5,6호기 주제어실 공기정화계통의 공급자 정보, 도면 등을 기준으로 실사를 통해 치수를 확인하여 3D CAD 모델을 작성하였다. 모델과 현장 계통의 실측 유량을 기준으로 CFD 분석을 수행하였다. 공기정화계통으로 유입되는 공기는 $30^{\circ}C$, 유동형태는 균일한 것으로 가정하고, 검사 기록지에 의한 주제어실 ESF 공기정화계통의 유량이 12,986 CFM이고, $610{\times}610mm^2$의 HEPA 필터가 9개 설치되어 있으므로 HEPA 필터 단면를 지나는 유속은 1.83 m/s이다. 주제어실 공기정화계통 모델링시 공기 유동이 흐르지 않는 필터 테두리 지지대를 고려하여 현장과 유사한 유동현상을 모사하였다. 약 8 m/s로 기록된 활성탄 흡착기 하단의 공기유동은 별도의 분석을 통해 7 m/s 이상의 유속이 모사되도록 CFD 분석하였다. 연료건물 비상배기계통 및 비상노심냉각계통 기기실 배기정화계통의 공기정화계통에 대해서도 CFD 분석한 결과, 시뮬레이터의 유속을 조절하면 세가지 ESF 공기정화계통을 모두 모사할 수 있음을 확인하였다. CFD 분석 후 시뮬레이터를 원자력등급으로 제작하였고, 본 실험에 착수하기 전에 공기유동 분포도실험을 통해 시뮬레이터의 신뢰도를 검증하였다. 검증결과 중급 필터를 장착한 상태에서 시뮬레이터의 필터 지지대 부분을 제외한 내부에서 공기유동이 고르게 분포함을 확인하였고, 제작된 시뮬레이터는 Reg. Guide 1.52(Rev.3) 개정 내용 확인을 위한 실험에 사용되었다.

환기장치와 필터를 활용한 미세먼지 제거특성 조사 (Characterization of Fine Dust Collection Using a Filter Ventilation)

  • 전태영;김재용
    • 공업화학
    • /
    • 제26권2호
    • /
    • pp.229-233
    • /
    • 2015
  • 본 연구에서는 폐암을 유발하는 발암물질이며 다양한 문제의 원인이 되고 있는 유해물질인 미세먼지 제거특성을 조사하였다. 변수로는 습도, 초기미세먼지 주입량, 유속을 고려하였다. 실험결과 습도가 높은 경우 제거에 소요되는 시간동안 평균 농도는 낮아지지만, 최종농도에는 큰 차이가 없었다. 세 가지 초기미세먼지주입량의 변화는 모두 비슷한 제거경향을 나타내었다. 또한 유속이 0.6 m/s에서 0.3 m/s로 변할 경우 제거소요시간이 약 1.4배 증가하는 결과가 관찰되었다. 본 연구에서는 습도, 미세먼지 주입량, 유속 중 미세먼지 제거에 가장 큰 변화를 보이는 것은 유속으로 관찰되었다.

미세물분무를 이용한 PPV의 화재진압효과 (Fire Suppression Effect of PPV with Water Mist System)

  • 김성원;신창섭
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.71-77
    • /
    • 2003
  • To inject fresh air into a fire room, Positive Pressure Ventilation (PPV) can be used and the blower of PPV increases inside pressure of the room. It makes high flow rate of products of combustion, smoke and heat from the structure, and it is very helpful to fireman on the fire extinguishing work. The flame moves to the direction of airflow and the temperature of flame can be decreased rapidly. In this experiment, a water mist system is applied to PPV to increase the effectiveness, and various effective factors are studied. n-Heptane and pine wood stick were used as fuel. Temperatures at the above and behind the combustion pan were strongly reduced by the water mist system and by the convective cooling with airflow. The smoke density was also decreased by PPV with water mist system and it can be explained by the absorption of smoke particles on the water mist droplet and by the strong exhausting effects of mobile fan.