• Title/Summary/Keyword: Ventilation simulation

Search Result 383, Processing Time 0.025 seconds

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL (도로터널 환기/제연 시스템 시뮬레이션)

  • Park, Jong-Tack;Won, Chan-Shik;Hur, Nahm-Keon;Cha, Cheol-Hyun
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.20-25
    • /
    • 2006
  • In the present study, flow characteristics inside a road tunnel are simulated for the ventilation flows due to jet fan system and flows induces by the traffic. Traffic ventilation is numerically simulated by multiple reference frame. From the results of steady state simulation of tunnel ventilation, it is found that the proper ventilation is achieved by the designed jet fan system along with ventilating flow induced by the traffic. A transient simulation is also performed for the case of vehicle fire in the tunnel reversing the direction of rotation of some fans. The results suggest that the heat and smoke can be controlled by the proper changing of fan operation mode. The present results can be used to design proper ventilation system and effective smoke control system as well.

Study on Improvement of Thermal Environment by using Wind-driven Natural Ventilation on the Atrium (풍력환기에 의한 아트리움의 열환경 개선에 관한 연구)

  • Roh, Ji-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.40-47
    • /
    • 2012
  • According to the advancement of computer and simulation method, it becomes possible to predict indoor climate precisely by using CFD simulation coupled with heat conduction, convection, and radiation. However, predicting the indoor climate is generally conducted by using a simplified CFD coupled simulation method since it takes quite long time to use a general CFD simulation method. In this study, a simplified CFD coupled simulation was conducted in order to find out the effect of natural ventilation by wind-driven in atrium. As a result of calculation, it was clarified that the natural ventilation driven by temperature difference was not enough to remove the accumulated heat of upper zone and the natural ventilation by wind-driven was needed. Finally, it is required to decide the window direction and size based on correct indoor climate prediction method for the effective use of natural ventilation by wind-driven.

Unsteady Numerical Simulation on the Ventilation in a Long Rail Tunnel (장대터널내 열차운행시 환기에 대한 비정상 수치해석)

  • Hur, Nahm-Keon;Kim, Wook;Kim, Sa-Ryang;Cha, Chul-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.448-454
    • /
    • 2001
  • In the present study, the transient axi-symmetric numerical simulation of traffic ventilation induced by a train running through a 15.6km-long tunnel is performed by using over 100,000 computational cells. With train running, three cases of ventilation schemes are simulated, which are the case of ventilation fans turned on, the case of no fan but ventilation shafts open, and the case of no fan and no shaft. Results of the ventilation flow rate are pressure transients are compared for the cases considered.

  • PDF

Calibration in Hybrid Ventilation Simulation: yes or no? (하이브리드 환기 시뮬레이션 모델의 보정: yes or no?)

  • Kim, Young-Jin;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.130-135
    • /
    • 2009
  • This study investigates the need of calibrating a nodal network ventilation simulation model (CONTAMW 2.4). For this purpose, the series of ventilation experiments were conducted and then compared to simulation outputs from an uncalibrated simulation model, resulting in a significant difference between two. Hence, an optimization routine was employed to estimate unknown parameters in the simulation model. In the paper, the authors presents 1.3 unknown parameters with the validated simulation model. It was found that the model with estimated unknown parameters predicts the ventilation phenomena accurately.

  • PDF

The Study of Jet Fan Control Logic for Longitudinal Ventilation in Road Tunnel (젯트팬 종류식 터널의 퍼지응용 제어로직에 관한 연구)

  • 유지오;남창호;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.763-770
    • /
    • 2000
  • In tunnel ventilation, the Purpose of ventilation control is to keep the required pollution level with minimum consumption of energy But tunnel ventilation has large disturbances caused by discharge of pollutants, traffic forces especially strong for longitudinal ventilation. Hence in this paper, the tunnel ventilation control logic applying fuzzy control theories is proposed and the simulation program of tunnel ventilation control is developed. The characteristics of longitudinal ventilation with jet fans are estimated and the effect of the proposed tunnel ventilation control is verified by the simulation program.

  • PDF

A Study on Numerical Analysis and Performance Improvement of Ventilation Systems in Coating Room (코팅 룸 배기시스템 수치해석 및 성능개선에 대한 연구)

  • Lee, Ki Yeon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2086-2091
    • /
    • 2013
  • One of the most important objects for the industrial ventilation is to protect worker's health from the harmful substances. Mainly in industrial ventilation, the harmful substances broken out through manufacturing process are to be quickly emitted outside. Recently the importance of the industrial ventilation increases with the recognition change of industrial ventilation from manufacturing focusing to human focusing. In this paper, the air flow simulation inside the coating room is performed. All the coating room and the ventilation system are modeled by SolidWorks program and air flow distribution and ventilation performance are analyzed by Flow simulation program. And the air flow directions and the air flow velocities inside the coating room are enhanced with the use of local ventilation.

Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room (CFD해석에 의한 침실 호흡역의 환기효율 분석)

  • Yoo, Bok-Hee;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station (화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석)

  • Shin, Kyu-Ho;Hur, Nahm-Keon;Won, Chan-Shik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL (도로터널 환기/제연 시스템 시뮬레이션)

  • Park Jong-Tack;Won Chan-Shik;Hur Nahmkeon;Cha Cheol-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.207-212
    • /
    • 2005
  • In designing a ventilation system of a road tunnel, a possibility of using the system as a smoke control system in case of a tunnel fire has to be considered. In the present study, a numerical simulation on ventilation system is performed considering jet fan operations and moving traffic. A fire-mode operation by reversing some fan operations in case of a tunnel fire is also simulated. The results show that ventilation operation can control the pollutants effectively, and fire-mode operation can control smoke and temperature effectively to prevent a disaster.

  • PDF