• Title/Summary/Keyword: Ventilation method

Search Result 748, Processing Time 0.031 seconds

A Study on Exposure Indices for Diesel Engine Exhaust in Forklift Operating Areas (지게차 사용 사업장에서 디젤엔진배출물질 노출지표에 관한 연구)

  • Kim, Sangil;Park, Ji Young;Lee, Kyeongmin;Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.38-47
    • /
    • 2016
  • Objectives: The objective of this study was to determine the exposure levels of forklift operators to diesel engine exhaust(DEE) using black carbon(BC), elemental carbon(EC), and nitrogen dioxide($NO_2$) as indicators. Methods: A total of eight forklift operators in six collection companies were assessed over a period of two months from July to September 2015. BC was measured using a real-time monitor and respirable EC samples were analyzed using the NIOSH method 5040. $NO_2$ samples were collected using a passive badge-type sampler. Results: The geometric mean of BC, EC and $NO_2$ were $3.1-19.1{\mu}g/m^3$, $2.1-23.8{\mu}g/m^3$, and 12.5-166.6 ppb at all companies. When forklifts were operating both outside and inside, BC concentrations increased 2.0-5.6 times. The highest increase was observed when forklifts were operating indoors. The increase in BC concentrations varied by company(company A: 2.0 times, B: 3.2 times, C: 5.6 times, D: 2.1 times, E: 5.1 times, F: 2.6 times). The geometric mean of BC, EC, and $NO_2$ for the forklift operators was $9.6{\mu}g/m^3$, $7.9{\mu}g/m^3$, and 48.9 ppb, respectively. The geometric mean of BC, EC, and $NO_2$ for manufacturing workers was $9.3{\mu}g/m^3$, $0.9{\mu}g/m^3$, and 85.2 ppb, respectively. The mean BC and EC exposure levels for the forklift operators were slightly higher than those for manufacturing workers, but $NO_2$ levels for manufacturing workers were higher than those for the forklift operators(p>0.05). Multiple regression analysis revealed that diesel exhaust emissions standard, forklift weight and forklift manufacturer were the most influential factors in determining worker exposure. Conclusions: In the DEE work environment, workers who perform tasks within the workplace as well as inside forklifts as operators are likely to be exposed to a lack of ventilation. Further study of forklift operators' exposure to DEE indicators should be conducted to include a wider range of occupational and environmental situations, such as collection procedures, seasonal situations, types of fuel used, and number of forklifts.

Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process (반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템)

  • Choi, Kwang-Min;Lee, Ji-Eun;Cho, Kwi-Young;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

The Early Results of CABG with Bilateral Internal Thoracic Artery (양측 내흉동맥을 이용한 관상동맥우회술의 조기 결과)

  • 조광현;최강주;김경현;전희재;윤영철;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.303-308
    • /
    • 2003
  • Background: It has been known that internal thoracic artery grafting has a better patency rate compare to other graft conduits in coronary revascularization. Better patency rates can be expected in more coronary arteries with the use of bilateral internal thoracic artery. However, there were some debates on the complications after the use of bilateral internal thoracic artery. The purpose of our study was to reveal the results of bilateral internal thoracic artery. Material and Method: The 26 coronary artery bypass operations with bilateral internal thoracic artery were performed from July 2001 to May 2002. We compared the results of 8 diabetic patients to those of 18 non-diabetic patients. We compared the results of BITA (bilateral internal thoracic artery) group to those of SITA (single internal thoracic artery) group that were 20 patients and performed during same period. Result: There was no mortality. There was one wound complication in the diabetic group and one in the non-diabetic group. There were no significant differences in operation time, duration of mechanical ventilation, amount of bleeding, infusing duration of cardiotonics, and complication between two groups. There were no significant differences in results between the BITA group and the SITA group. Conclusion: There were no significant differences in early results between the BITA group and the SITA group, and there were no significant differences in results between the diabetic group and the non-diabetic group. We think coronary artery bypass grafting with the use of bilateral internal thoracic artery is considered in diabetic patients.

Determination of Hot Air Drying Characteristics of Squash (Cucurbita spp.) Slices

  • Hong, Soon-jung;Lee, Dong Young;Park, Jeong Gil;Mo, Changyeun;Lee, Seung Hyun
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2017
  • Purpose: This study was conducted to investigate the hot air drying characteristics of squash slices depending on the drying conditions (input air velocity, input air temperature, and sample thickness). Methods: The developed drying system was equipped with a controllable air blower and electric finned heater, drying chamber, and ventilation fan. Squash (summer squash called Korean zucchini) samples were cut into slices of two different thicknesses (5 and 10 mm). These were then dried at two different input air temperatures (60 and $70^{\circ}C$) and air velocities (5 and 7 m/s). Six well-known drying models were tested to describe the experimental drying data. A non-linear regression analysis was applied to determine model constants and statistical indices such as the coefficient of determination ($R^2$), reduced chi-square (${\chi}^2$), and root mean square error (RMSE). In addition, the effective moisture diffusivity ($D_{eff}$) was estimated based on the curve of ln(MR) versus drying time. Results: The results clearly showed that drying time decreased with an increase in input air temperature. Slice thickness also affected the drying time. Air velocity had a greater influence on drying time at $70^{\circ}C$ than at $60^{\circ}C$ for both thicknesses. All drying models accurately described the drying curve of squash slices regardless of slice thickness and drying conditions; the Modified Henderson and Pabis model had the best performance with the highest R2 and the lowest RMSE values. The effective moisture diffusivity ($D_{eff}$) changes, obtained from Fick's diffusion method, were between $1.67{\times}10^{-10}$ and $7.01{\times}10^{-10}m^2/s$. The moisture diffusivity was increased with an increase in input air temperature, velocity, and thickness. Conclusions: The drying time of squash slices varied depending on input temperature, velocity, and thickness of slices. The further study is necessary to figure out optimal drying condition for squash slices with retaining its original quality.

Monitoring of Formaldehyde Concentration in Exhibition Hall Using Passive Sampler (Passive Sampler를 이용한 유물 전시관내 폼알데하이드 농도 모니터링)

  • Lee, Sun Myung;Lim, Bo A;Kim, Seojin
    • Journal of Conservation Science
    • /
    • v.33 no.5
    • /
    • pp.319-329
    • /
    • 2017
  • In this study, formaldehyde concentrations in two exhibition halls were monitored using a passive sampler from May 2012 to April 2013. Formaldehyde concentrations in the exhibition halls were 5 to 36 times higher than concentrations outdoors. Concentrations inside the exhibition room and showcase varied according to pollutant source, HVAC(heating, ventilation, air conditioning)system and environment management. The formaldehyde concentration levels were corrected according to a standard method prescribed by Indoor Air Quality Management Law of the Ministry of Environment, Korea. As a result, Most concentration levels exceeded the exhibition standard of the Ministry of Environment($100{\mu}g/m^3$) and artifacts conservation standard of Tokyo National Museum($50{\mu}g/m^3$). Seasonal concentrations in the exhibition room and showcase were in the order summer>fall>spring>winter. Formaldehyde emissions increased in summer when air temperature and relative humidity are both high. Formaldehyde concentration distribution according to the temperature and relative humidity showed positive correlation. Air temperature showed good correlation because $R^2$ was in the range of 0.8~0.9. Analysis of formaldehyde emission characteristics in the exhibition hall would be helpful in efforts to improve indoor air quality.

A Study on the Calculation Method of Load standard for ZEB activation (ZEB 활성화를 위한 부하기준 산정 방법 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.92-99
    • /
    • 2017
  • In Korea, the zero energy building was designated as the 7 new industries in the Ministry of Land and the 8 new industries in the Ministry of Industry. In order to maximize the insulation performance of the building envelope, improve the efficiency of building equipment, We are aiming. It is necessary to analyze the energy requirements of the buildings (cooling, heating, hot water supply, lighting, ventilation) of buildings with energy efficiency level of 1++ which is equivalent to the zero energy building certification system in Korea, It is aimed to be used as basic data for the advancement of energy building certification system. Zero Energy Building certification is estimated to be 61 buildings by 2017, and the approximate reference value and the first energy requirement for each of the five loads are calculated considering passive and active aspects. It is difficult to say that it is a clear standard because there is a small sample of data for calculating the load standard. However, it is necessary to interpret various methods in order to upgrade the Zero Energy Building certification standard in the future.

Clinical Analysis of Iatrogenic Pneumothorax (의인성 기흉에 대한 임상 고찰)

  • Choi, Si-Young;Moon, Mi-Hyoung;Kwon, Jong-Bum;Kim, Yong-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.744-748
    • /
    • 2009
  • Background: This study was designed to determine etiologic factors for iatrogenic pneumothorax in an era of in-creased use of invasive procedures and to evaluate its impact on morbidity. Material and Method: Subjects were 112 patients (65 men and 47 women ranging in age from 20 to 90 years) who were diagnosed with an iatrogenic pneumothorax between January 2005 and December 2008. We reviewed medical records retrospectively. Result: The leading causes of iatrogenic pneumothorax were percutaneous needle aspiration (50), central venous catheterization (29), acupuncture (14), thoracentesis (8) and positive pressure ventilation (7). The majority of the patients (60 of 114) were treated with chest tubes. The mean duration of hospital treatment was 5.8 $({\pm}4.0)$ days. Hospitalization was prolonged in 24 patients (21.1%). No patient died from iatrogenic pneumothorax. Conclusion: In our study, the most common cause of Iatrogenic pneumothorax was percutaneous needle aspiration. The mortality and morbidity from iatrogenic pneumothorax is not significant. The recognition of pneumothorax, depends on careful examination after completion of an invasive procedure, and should be followed by prompt and definitive therapy.

Capnographic Monitoring of End-Tidal Partial Pressure of Carbon Dioxide in Anesthetized Cinereous vultures (Aegypius monachus) (독수리(Aegypius monachus)의 흡입마취에서 Capnography를 이용한 호기말 이산화탄소분압 모니터링)

  • Park, Won-Kyu;Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Kim, Young-Ki;Hwang, Jae-Min;Jeong, Dong-Hyuk;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.380-384
    • /
    • 2015
  • The relationships between end-tidal partial pressure of carbon dioxide ($P_{ET}CO_2$) and arterial partial pressure of carbon dioxide ($P_aCO_2$), and between $P_{ET}CO_2$ and blood pH in isoflurane-anesthetized cinereous vultures were evaluated. Nine cinereous vultures (weighing 7.3-9.5 kg) were anesthetized via mask with isoflurane, intubated, and connected to a mechanical ventilator. By mechanical ventilator, respiratory rate was altered to achieve a $P_{ET}CO_2$ randomly selected among 30 to 35 mmHg. $P_aCO_2$ and blood pH were determined in serial arterial samples and compared with concurrent $P_{ET}CO_2$ measured with a sidestream capnography. Thirty six samples, nine cinereous vultures were tested 4 times each, were used to determine correlations coefficients between $P_aCO_2$ and $P_{ET}CO_2$, and between $P_{ET}CO_2$ and blood pH. Strong correlations were observed between $P_aCO_2$ and $P_{ET}CO_2$ (r = 0.951, P = 0.000, y = 1.679x - 30.236, $R^2=0.905$) as well as between $P_{ET}CO_2$ and blood pH (r = -0.728, P = 0.000, y = -0.024x + 8.389, $R^2=0.530$) with Pearson's correlation coefficient and simple linear regression. These results suggest that the capnography used provided a sufficiently accurate estimation of $P_aCO_2$ and blood pH. Thus, the monitoring of $P_{ET}CO_2$ can be useful method to prevent hypoventilation for cinereous vultures receiving mechanical ventilation.

Health effects on workers and actual exposure of VOCs in the nail shops (네일샵 종사자의 휘발성유기화합물 노출실태와 건강에 미치는 영향)

  • Kim, Nan-Hee;Min, Kyoung-Woo;Cho, Gwang-Woon;Seo, Dong-Ju;Im, Kyeong-Hun;Jeung, Won-Sam;Cho, Young-Gwan;Yang, Jin-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.59-69
    • /
    • 2017
  • Objectives: The objective of this study is to evaluate the exposure of VOCs and effects of the chemicals on the nail technicians whose works in a nail shop. Methods: For four month from May to August in 2016, we measured twenty-two kinds of VOCs in ten nail shops and carried out health examinations on thirty-four workers in there. Results: The TVOC concentration in indoor air of nail shops is $0.487mg/m^3$ at a minimum and $33.236mg/m^3$ at a maximum where it consists of 70.5% of Ketones, 25.4% of Alcohols, 2.6% of Esters, 0.8% of Aldehydes and 0.7% of Aromatics. The VOCs concentration during nail art works shows an increase in average ratio 1.8 compared to the concentration of indoor air quality and also the concentration of Isopropanol rose with 3.2 of the highest ratio. The results of Spearman correlation between TVOC concentration in indoor air and environmental factor was like that has significance level of correlation(${\rho}$<0.05, r=0.682) in case of number of customers per day, but the other factors were not meaningful in correlation. Correlation between VOCs and medical check-up items was like that has positive significance level(${\rho}$<0.01, r=0.638) between isopropanol and GPT, but the others have not meaningful. The exposure level of VOCs was not exceed the criteria exposure level 1 of working environment measuring method which announced by labor ministry in all ten nail shop indoor air quality. Conclusions: In this study although it was not significant correlation between harmful substances and medical check-up items in the nail shop indoor air quality, it is necessary to do more ventilation and to install exhaust facilities because of existing high VOCs concentration in the nail shop indoor air.

Deep Sedation with Sevoflurane in Patients with Double Outlet of Right Ventricle (양대혈관 우심실 기시 환아의 Sevoflurane을 이용한 깊은 진정 하 치과치료)

  • Hyun, Hong-Keun;Shin, Teo Jeon;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Kim, Hyun-Jeong;Seo, Kwang-Suk;Lee, Jung-Man;Shin, Soonyoung
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.2
    • /
    • pp.115-119
    • /
    • 2012
  • Double outlet of right ventricle (DORV) refers to a congenital heart disease in which pulmonary and systemic circulation originates from the right ventricle. In the patient with DORV, it is important to maintain the balance between pulmonary and systemic circulation in anesthetic management. A 4-year-old boy with DORV, who underwent a Blalock-Taussig shunt operation, was transferred to the clinic with a chief complaint of multiple caries. Due to poor cooperability, it was impossible to treat the caries without sedation or general anesthesia. We planned to sedate him with consideration with detrimental effects associated with positive pressure ventilation for dental treatment. After a prophylactic administration of antibiotics, sevoflurane was administered through T-cannula site. Throughout the treatment, His blood remained stable around 80/40 mmHg, oxygen saturation remained around 91%. After 3 hour of sedation with sevoflurane (end-tidal sevoflurane con 1-1.8 vol%), he fully regained consciousness, and discharged from hospital without complications. In case of DORV patient, deep sedation with sevoflurane may be used as effective method of behavioral management during dental treatment.