• Title/Summary/Keyword: Ventilation method

Search Result 748, Processing Time 0.029 seconds

A Study on Fire ventilation design of road tunnel (도로터널에서의 화재환기 설계에 관한 연구)

  • Kim, Myung-Bae;Choi, Byung-Il;Choi, Jun-Seok;Han, Yong-Shik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • The several assumptions and design parameters to determine the ventilation rate in tunnel ventilation system were examined. In longitudinal ventilating tunnel, the ventilation rate has been determined by the critical velocity above which the smoke propagation to the upstream of ventilating air is prevented. Based upon the examination of assumptions and experimental results, we suggested the improved method to determine the critical velocity. In transverse ventilating tunnel, we found that the ventilation rate has been determined in accordance with the custom rather than fire-smoke dynamics such as the critical velocity in the longitudinal ventilating tunnel. It is because the ventilation rate in the transverse ventilation system has been determined by considering only the ventilation of contaminant by vehicle. To improve the ventilation design parameters based upon the fire-smoke dynamics, we conducted model tunnel fire experiments. From the experimental results, smoke propagating distance and smoke filling were suggested as the design parameter to determine the ventilation rate in transverse ventilating tunnel. And tunnels in Europe designed by the custom is found to have the dangerous nature in view of fire safety.

  • PDF

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

A Study on the Ventilation Effect by Various Location of Air Intake and Exhaust Fan of Bathroom in Apartment Housing (공동주택 화장실의 급기구 및 배기팬 설치위치에 따른 환기효과에 관한 연구)

  • Ham Jin Sik;Lee Kwang Myung
    • Journal of the Korean housing association
    • /
    • v.15 no.5
    • /
    • pp.77-84
    • /
    • 2004
  • The mock-ups of ventilation system, which has been widely adopted for the bathroom with the area of 100 $m^2$ apartment housing, were established and tested to design mechanical ventilation for apartment housing bathroom where air supply exhaust are relatively important. These ventilation mock-ups were capable of controlling intake and exhaust, which has the size of supply openings as 40cm${\times}$1cm, 40cm${\times}$3cm, 40cm${\times}$5cm. They were established at five locations, spaced 40cm from each other at a height of 25cm from the floor. The exhaust fans were located at four corners and center of the ceiling. The results this ventilation effect measurement by different condition are showing that when the size of air supply is bigger and the location is lower, the effect of ventilation was relatively higher. In addition, as the distance between exhaust fan and air supply was farther, the ventilation effect were getting highly efficient.

Numerical Study on the Ventilation Performance in the Boiler Building with and without Roof Openings (루프 환기구에 따른 보일러빌딩 내부 환기성능에 관한 수치적 연구)

  • Choi, Hoon Ki;Yoo, Geun Jong;Lee, Sang Heon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.342-349
    • /
    • 2016
  • Objectives: The objective of this paper is to find flow and heat transfer characteristics numerically in boiler buildings for three different ventilation window configurations. Methods: Turbulent natural convection flow in boiler buildings with a constant heating wall temperature was analyzed numerically. Governing equations were solved with standard finite-volume method using the SIMPLE algorithm. Conclusions: Flow and heat transfer characteristics are found for three different ventilation types. In the lower area under furnace, velocity and temperature distributions show similar patterns among the three different ventilation types. In the upper area over furnace, however, air flow is well mixed with lower peak temperatures for types B and C, which have roof ventilation windows, compared to type A which has side wall louvers only. Also, type B, with a single large roof window, shows better ventilation effect than does type C with its distribution roof windows.

Comparison of tracheal intubation using the Macintosh laryngoscope versus the intubating laryngeal mask airway in novice users - A manikin study - (초보자에서 마네킨에게 직접 후두경과 삽관용 후두마스크기도기를 이용한 기관내삽관의 비교)

  • Hwang, Ji-Young;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.2
    • /
    • pp.75-89
    • /
    • 2012
  • Purpose : This research was designed to provide basic data for advanced pre-hospital airway management by comparing the time to ventilation and success rate for tracheal intubation performed with Macintosh laryngoscope and intubating Laryngeal Mask Airway(ILMA) in a manikin. Methods : All participants were novice users among EMT-Paramedic students and were divided into two groups: (1) the group for Macintosh laryngoscope guided tracheal intubation(MLG-TI) (2) the group for ILMA guided tracheal intubation(ILMA-TI). After an introductory lecture and demonstration, each group made an attempt ten tracheal intubation to compare the ventilation time and success rate for tracheal intubation. Results : 1) There was significant difference in the time to ventilation through MLG-TI, the time to first and second ventilation through ILMA-TI of the 10 attempts. 2) The time to first ventilation through ILMA-TI was significantly shorter than that of ventilation through MLG-TI. 3) There was no significant difference between the time to ventilation through MLG-TI and the time to second ventilation through ILMA-TI. 4) The success rates of ILMA-TI were significantly higher than those of MLG-TI. Conclusion : ILMA-TI can be an alternative method for MLG-TI in advanced pre-hospital airway management.

An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel (도로터널에서 종류식 환기 시설의 운전 방안)

  • Kim, T.H.;Hwang, I.J.;Hong, D.H.;Chung, J.S.;Chung, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

A study on the ventilation characteristics and design of transverse ventilation system for road tunnel (도로터널 횡류환기방식의 환기특성 및 시스템 설계 관한 연구)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.305-315
    • /
    • 2018
  • In this study, the ventilation characteristics and the relationships between the required ventilation flow rate and the ventilation system flow rate was investigated by numerical method for the optimum design of the transverse ventilation and semi-transverse ventilation system in road tunnels. The following results were obtained. In supply exhaust transverse ventilation system, the system supply-exhaust air flow rate is theoretically equal to the difference between the required ventilation flow rate and natural ventilation flow rate. However, it is shown that it increases by about 10% in the analysis results. And, in the case of the longitudinal air flow rate is increased by installed jet fans, ventilation system air flow rate is reduced. However, as the longitudinal air flow rate increases, the concentration of pollutants in the tunnel decreases, so the exhaust effect of pollutants decreases, and the effect of reducing the system air flow rate is decreased. In case of semi-transverse with only air supply, ventilation system air flow rate is equal to required ventilation air flow rate when tunnel inlet velocity is negative, but results is shown it is increased within about 13.3%. Also, it was found that ventilation effect can not be expected even if the jet fans are increased when the tunnel inlet velocity is negative.

Characteristics and Management of Particulate Matter(PM2.5) Emission on Cooking Condition (주방 조리시 미세먼지(PM2.5) 배출 특성과 관리방안)

  • Lee, Myeonggu;Jeong, Myeongjin;Kang, Minji
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.325-329
    • /
    • 2018
  • There are many pollutants in the residential space due to building materials, ventilation, cooking, etc. Among them, particulate matter is a primary carcinogen and very harmfull to the human body, it occurs mostly in cooking. Therefore, in order to manage the indoor air quality well, it is necessary to evaluate the relationship between the concentration of particulate matter generated during cooking and ventilation method. In this study, we propose a management method and particulate matte which occurs during the kitchen cooking by measuring and analyzing the concenteation change of particulate matter(PM2.5) according to the type of food and the ventilation method.