• 제목/요약/키워드: Ventilation effect

검색결과 646건 처리시간 0.025초

신축 공동주택에서 베이크 아웃 시 환기 조건에 따른 마감재에서의 방출량 저감 효과 (The Effect of Ventilation on VOCs Emission rate during the Bake-out Procedure in Newly Constructed Apartments)

  • 박동선;손장열
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.708-713
    • /
    • 2008
  • Various kinds of contaminant are generated from many kinds of interior construction materials, furniture and life articles. People of today living indoor most of the time are exposed to these kinds of contaminant. In this connection, people are exerting their efforts to reduce the occurrence of contaminant from the interior finish materials. And it is the actual condition that research is being actively made on the method of reducing contaminant by performing bake-out for newly constructed housings. Bake-out is the method of temporarily increasing the generation of the harmful contaminant quantity including VOCs and Formaldehyde emitting from construction materials or finish materials by increasing the interior temperature of the newly constructed buildings or improved or repaired buildings, and then removing it by mobilizing ventilation system. In this study, the researcher measured the effect of reduced concentration according to ventilation or non-ventilation of the newly constructed but not yet resident public housings during the bake-out in order to grasp the effect of reduced interior air contaminant according to the elapse of timeat the time of bake-out.

  • PDF

공동주택에서 각 실 문의 개폐에 따른 환기 특성 연구 (A Study on the Effect of Open and Closed Room Doors on Apartment Ventilation Characteristics)

  • 최임규;김영일;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.469-474
    • /
    • 2008
  • The objective of this study is to propose basic design guidelines for more effective air ventilation system in apartments. It is well known that ventilation depends on whether the room doors are open or closed as well as people's living patterns. This study considers 84 ㎡-sized apartment which has extended living room without balcony. Ventilation of bathroom and kitchen is not considered. The height of the building, external air pressure and air infiltration through the windows are also neglected. The regulation on indoor air quality made it mandatory that the air change per hour be more than 0.7. Four models are suggested to study the effect of open and closed doors. Models 1 and 3 are open door types and models 2 and 4 are closed door types. The open types have 50 mm hole near the top of the door to substitute exhaust outlet. The ventilation effectiveness was evaluated by 3-dimensional numerical simulation using finite volume method by a commercial software. This work compares air flow, temperature of air, age of air and the efficiency of ventilation of apartments with wooden doors of bedroom 1 and 2, which are open or closed.

  • PDF

케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구 (A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types)

  • 최태환;김태연;이승복
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

해인사 장경판전 환기창 형태에 따른 환기 성능에 대한 수치해석 연구 (A Numerical Study on the Effect of the Shape of Windows on the Ventilation Performance in the Storage Hall of Tripitaka Koreana at Haein Temple)

  • 허남건;이명성;양성진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.119-123
    • /
    • 2007
  • Ventilation performance in the storage hall of Janggyeongpan Jeon has maintained for more than 600 years. Janggyeongpan Jeon in Haein temple has window structure of bi-level ventilating opening which consists of upper and lower window. Also, different size and shape of windows are adopted for various locations of the hall. In the present study, to analyze effect of shape of windows on ventilation performance in the storage hall, various design alternatives were considered. Numerical analysis of ventilation in the storage hall was investigated under the same simulation condition except for the shape of windows. Through the comparison of numerical results for various window designs, it was evaluated that the current windows shape gives best ventilation performance.

  • PDF

큰 개구부를 가진 단일구획 빌딩에서의 자연환기 모델의 개발 (Development of a Natural Ventilation Model in a Single Zone Building with Large Openings)

  • 조석호
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.359-369
    • /
    • 2018
  • A model has been developed to predict natural ventilation in a single zone building with large openings. This study first presents pressure-based equations on natural ventilation, that include the combined effect of wind and thermal buoyancy. Moreover, the concept of neutral pressure level(NPL) is introduced to consider the two-way flow through a large opening. The total pressure differences across the opening and the NPL are calculated, and nonlinear equations are solved to find the zonal pressure to satisfy mass conservation. For this analysis, an iterative technique of successively approximating the zonal pressure is used. The results of applying this study model to several simple cases are as follows. When there is no wind and only the stack effect is caused, a one-way flow occurs in both the top and bottom openings in the case of two openings of equal-area, and a one-way flow occurs in the top opening; however, a two-way flow occurs in the bottom opening in the case of two openings of unequal-area. When there is a wind effect, regardless of whether the outside air temperature is lower or higher than the indoor air temperature, air flows into the room through the bottom opening and out of the room through the top opening. As the wind velocity increases, the wind effect appears to be more influential than the stack effect owing to the temperature difference.

제조담배의 연기희석에 미치는 재료품과 궐련 물성 연구 I. 제조담배의 연기희석율과 팁 흡인저항에 미치는 팁페이파 및 필터권지 기공도의 영향 (Study on cigarette ventilation with cigarette materials and the properties of cigarettes 1. Effect of tipping paper permeability and plugwrap porosity on the cigarette pressure drop and ventilation)

  • 김성한;오영일;이영택;박태무
    • 한국연초학회지
    • /
    • 제10권1호
    • /
    • pp.83-91
    • /
    • 1988
  • The effects of tipping paper permeability and plugwrap porosity on the ventilation and the pressure drop of cigarettes have been studied and the results obtained were as follows. 1. The single and the multiple regression equation to estimate tip ventilation were establised. In the equations, the observed values of the tip ventilation with the varieties the plugwrap porosity were content with them by the single regression equation. 2. As based on the statistical consideration of the above equation, the deviation of the observed tip ventilation versus the tipping paper permeability were higher than them to the plugwrap porosity. 3. The regression equations to calculate pressure drop ratio and the total ventilation rate in filter tip from the tea ventilation were obtained. According to the equation, the observed values of the pressure drop ratio were significantly similar to them calculated. 4. It was found that the equations could be applied to the calculation of the ventilation of cigarettes using the mechanical and micro laser perforation tipping paper as well as the electrically perforated tipping paper of this Study.

  • PDF

실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과 (The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots)

  • 박정호
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구 (A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites)

  • 이정주;이주상;김신도
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

G.C를 이용한 Ventilation 측정방법과 Ventilation에서의 블라우스형태변화의 영향 (Method of Ventilation by Gas Chromatography and the Effects of the Type of Blouse)

  • 박우미;최철호
    • 한국의류학회지
    • /
    • 제16권1호
    • /
    • pp.53-63
    • /
    • 1992
  • The purpose of this study is to investigate the method of trace gas technique by G.C and the effects of the type of blouse on ventilation. The experimental system employed a trace gas technique in which ventilation was monitored to determine oxigen exchange rate. The experimental variables were tested with three types of blouse depending on the sizes of neckline, armhole and waist line. Exercise conditions include standing and walking position. The results and discussion forcused on the construct validity of the apparatus/testing protocol. the effect of experimental variables on ventilation was also discussed.

  • PDF

Hydrodynamic analysis of the surface-piercing propeller in unsteady open water condition using boundary element method

  • Yari, Ehsan;Ghassemi, Hassan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권1호
    • /
    • pp.22-37
    • /
    • 2016
  • This article investigates numerical modeling of surface piercing propeller (SPP) in unsteady open water condition using boundary element method. The home code based on BEM has been developed for the prediction of propeller performance, unsteady ventilation pattern and cross flow effect on partially submerged propellers. To achieve accurate results and correct behavior extraction of the ventilation zone, finely mesh has generated around the propeller and especially in the situation intersection of propeller with the free surface. Hydrodynamic coefficients and ventilation pattern on key blade of SPP are calculated in the different advance coefficients. The values obtained from this numerical simulation are plotted and the results are compared with experiments data and ventilation observations. The predicted ventilated open water performances of the SPP as well as ventilation pattern are in good agreement with experimental data. Finally, the results of the BEM code/experiment comparisons are discussed.